Loading...
HomeMy WebLinkAboutenergy Con3 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: CHARLENE CROWE BuilderName: Street: 4545 S. INDIAN RIVER DRIVE Permit Office: City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner: CHARLENE CROWE Jurisdiction: DesignLocation: FL, Fort Pierce County: St Lucie (Florida Climate Zone 2 ) 1. Newconstructionorexisting Addition 9. Wall Types (592.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame -Wood, Exterior R=13.0 416.00ft2 3. Number of units, if multiple family 1 b. Frame- Wood, Adjacent c. N/A R=13.0 176.00 ft2 R= ft2 4. Number of Bedrooms (Bedrms In Addition) 0(0) d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (398.0 sgft.) Insulation Area a. UnderAttic (Vented) R=19.0 398.00 ft2 6. Conditioned floor area above grade (ft2) 398 b. NIA R= ft2 Conditioned floorarea below grade (ft2) 0 c. R= ft2 � 7. Windows(29.0 sqft.) Description Area 11. Ducts R ft2 a. U-Factor: Sgl, U=0.79 29.00 ft2 SHGC: SHGC=0.00 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 22.0 SEER:20.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 22.0 HSPF:9.80 w SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.000 14. Hot water systems -Nonerequired 8. Floor Types (398.0 sgft.) Insulation Area a• Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 398.00 ft2 b. Conservation features EF: 0.028 b. N/A R= ft2 c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.073 Total Proposed Modified Loads: 7.50 PASS Total Baseline Loads: 11.66 1 hereby certify that the plans and specifications covered by Review of the plans and EKES ' r this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance, 01 ti, p with the Florida Energy Code. PREPAR BY: 4 - - -- -� Before construction is completed DATE: f-13-20 O this building will be inspected for compliance with Section 553.908 * ,� I hereby certify that this b ' ing, as d i ed, is in compliance Florida Statutes. with the Florida Energy dCpWE OWNER/AGENT: BUILDING OFFICIAL: DATE: ?-C�- DATE:------ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 11/13/2020 7:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SHMMARY r141=r1<I ICT RGpn0T PROJECT Title: Building Type: OwnerName: # of Units: BuilderName: Permit Office: Jurisdiction: FamilyType: New/Existing: Comment: CHARLENE CROWE User CHARLENE CROWE 1 Single-family Addition Bedrooms: a ConditionedArea: 398 Total Stories: 1 Worst Case: No RotateAngle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot# Block/Subdivision: PlatBook: Street: County: City, State.. Zip: Street Address 4545 S. INDIAN RIVER St. Lucie FT. PIERCE, FL, CLIMATE / V DesignLocation Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design DailyTemp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 398 3184 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ROOM 398 3184 No 0 1 No Yes Yes FLOORS # FloorType Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulation ROOM 104 ft 0 398 ft' ---- 0 1 0 ROOF / V # Roof Gable Roof Type Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Compositionshingles 419 ft2 0 ft, Medium N 0.6 No 0.7 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 398ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 UnderAttic (Vented) ROOM 19 Blown 398 ft' 0.1 Wood 11/13J2020 7:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CI4I=rKI IRT RFDnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 N 2 E 3 S _ 4 W Garage Frame -Wood Garage Frame -Wood Exterior Frame -Wood Exterior Frame- Wood ROOM 13 12 0 8 0 96.0 ft' 0 0.25 0.6 ROOM 13 10 0 8 0 80.0ft2 0 0.25 0.6 ROOM 13 26 0 8 0 208.0 ft' 0 0.25 0.6 ROOM 13 26 0 8 0 208.0 ft2 0 0.25 0.6 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Ft in Ft In Area 1 W Insulated ROOM None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. __ # Wall Omt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening_ 1 2 W 4 Metal Single(Clear) Yes 0.79 0 N 9.0 ft' 2 ft 0 in 1 ft 4 in None W 4 Metal Single(Clear) Yes 0.79 0 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 224 ft2 224 ft2 20 ft 8 ft 19 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 265.3 14.57 27.39 .0881 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 ElectricHeatPump/Existing/co Split Single HSPF:9.8 22kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/Existing/confirmed Split Single SEER: 20 22 kBtu/hr cfm 0.7 1 Ductless SOLAR HOT WATER SYSTEM FSEC Cert # CompanyName Collector Storage System Model# Collector Model# Area Volume FEF ft2 -- 11113/2020 7:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 IMPHT SUMMARY rWPrWI IST RFDnRT TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingJan HeatinEX)J Jan Feb Feb Mar Mar Apr E � APr Ma f May Jun Jun P X Jul Jul Au4 ri Aug e Sep Oct Oct HNOV Nov Dec Dec H Ventin [[ 11 Jan Feb [ Mar l [X] A r [ Ma Jun [ Jul Aug [ Se [X] Oct Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 66 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FurnitureFraction Space Default 8lbs/s .ft. 0 ftz Oft 0.3 ROOM 11/13/2020 7:21 AM EnergyGaugeO USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4