HomeMy WebLinkAboutenergy Con3
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: CHARLENE CROWE
BuilderName:
Street: 4545 S. INDIAN RIVER DRIVE
Permit Office:
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner: CHARLENE CROWE
Jurisdiction:
DesignLocation: FL, Fort Pierce
County: St Lucie (Florida Climate
Zone 2 )
1. Newconstructionorexisting Addition
9. Wall Types (592.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame -Wood, Exterior
R=13.0 416.00ft2
3. Number of units, if multiple family 1
b. Frame- Wood, Adjacent
c. N/A
R=13.0 176.00 ft2
R= ft2
4. Number of Bedrooms (Bedrms In Addition) 0(0)
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (398.0 sgft.)
Insulation Area
a. UnderAttic (Vented)
R=19.0 398.00 ft2
6. Conditioned floor area above grade (ft2) 398
b. NIA
R= ft2
Conditioned floorarea below grade (ft2) 0
c.
R= ft2 �
7. Windows(29.0 sqft.) Description Area
11. Ducts
R ft2
a. U-Factor: Sgl, U=0.79 29.00 ft2
SHGC: SHGC=0.00
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
22.0 SEER:20.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
22.0 HSPF:9.80 w
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.000
14. Hot water systems -Nonerequired
8. Floor Types (398.0 sgft.) Insulation Area
a•
Cap: N/A
a. Slab -On -Grade Edge Insulation R=0.0 398.00 ft2
b. Conservation features
EF: 0.028
b. N/A R= ft2
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.073 Total Proposed Modified Loads: 7.50
PASS
Total Baseline
Loads: 11.66
1 hereby certify that the plans and specifications covered by
Review of the plans and
EKES ' r
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance,
01
ti, p
with the Florida Energy Code.
PREPAR BY:
4 - - -- -�
Before construction is completed
DATE: f-13-20 O
this building will be inspected for
compliance with Section 553.908
* ,�
I hereby certify that this b ' ing, as d i ed, is in compliance
Florida Statutes.
with the Florida Energy dCpWE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: ?-C�-
DATE:------
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
11/13/2020 7:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SHMMARY r141=r1<I ICT RGpn0T
PROJECT
Title:
Building Type:
OwnerName:
# of Units:
BuilderName:
Permit Office:
Jurisdiction:
FamilyType:
New/Existing:
Comment:
CHARLENE CROWE
User
CHARLENE CROWE
1
Single-family
Addition
Bedrooms: a
ConditionedArea: 398
Total Stories: 1
Worst Case: No
RotateAngle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot#
Block/Subdivision:
PlatBook:
Street:
County:
City, State.. Zip:
Street Address
4545 S. INDIAN RIVER
St. Lucie
FT. PIERCE,
FL,
CLIMATE
/
V DesignLocation
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design DailyTemp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70 75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
398 3184
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
ROOM
398 3184 No 0
1 No
Yes Yes
FLOORS
#
FloorType
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
ROOM 104 ft 0
398 ft' ----
0 1 0
ROOF
/
V #
Roof Gable Roof
Type Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Compositionshingles 419 ft2 0 ft, Medium
N 0.6 No 0.7
No 0 18.4
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 398ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
_ 1
UnderAttic (Vented)
ROOM 19 Blown
398 ft' 0.1
Wood
11/13J2020 7:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CI4I=rKI IRT RFDnRT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
0
1 N
2 E
3 S
_ 4 W
Garage Frame -Wood
Garage Frame -Wood
Exterior Frame -Wood
Exterior Frame- Wood
ROOM 13 12 0 8 0 96.0 ft' 0 0.25 0.6
ROOM 13 10 0 8 0 80.0ft2 0 0.25 0.6
ROOM 13 26 0 8 0 208.0 ft' 0 0.25 0.6
ROOM 13 26 0 8 0 208.0 ft2 0 0.25 0.6
0
0
0
0
DOORS
#
Ornt Door Type
Space Storms U-Value Width Height
Ft in Ft In
Area
1
W Insulated
ROOM None .39 3 6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
__ #
Wall
Omt ID Frame Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation IntShade
Screening_
1
2
W 4 Metal Single(Clear) Yes 0.79 0 N 9.0 ft' 2 ft 0 in 1 ft 4 in None
W 4 Metal Single(Clear) Yes 0.79 0 N 20.0 ft2 2 ft 0 in 1 ft 4 in None
None
None
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
224 ft2
224 ft2 20 ft 8 ft 19
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000254 265.3 14.57 27.39 .0881 5
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity Block
Ducts
1
ElectricHeatPump/Existing/co
Split Single HSPF:9.8 22kBtu/hr 1
Ductless
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
CentralUnit/Existing/confirmed
Split Single SEER: 20 22 kBtu/hr cfm 0.7 1
Ductless
SOLAR HOT WATER SYSTEM
FSEC
Cert
# CompanyName
Collector Storage
System Model# Collector Model# Area Volume FEF
ft2
--
11113/2020 7:21 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 IMPHT SUMMARY rWPrWI IST RFDnRT
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan
HeatinEX)J Jan
Feb
Feb
Mar
Mar
Apr
E � APr
Ma
f May
Jun
Jun
P
X Jul
Jul
Au4
ri Aug
e
Sep
Oct
Oct
HNOV
Nov
Dec
Dec
H
Ventin [[ 11 Jan
Feb
[ Mar
l
[X] A r
[ Ma
Jun
[ Jul
Aug
[
Se
[X] Oct
Nov
Dec
ThermostatSchedule:
HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling(WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
66
68
68
68
68
68
68
68
68
68
66
66
Heating(WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
FurnitureFraction
Space
Default 8lbs/s
.ft.
0 ftz
Oft
0.3
ROOM
11/13/2020 7:21 AM EnergyGaugeO USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4