HomeMy WebLinkAboutCROWE-MANUAL J (1)Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Nov-13 07:23:03
Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1
...CK\Documents\Wrightsoft HVAC\CROW, CHARLENE.rup Calc = MJ8 Front Door faces: N
Job:Project Summary Date:Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM
Project Information
CHARLENE CROWEFor:4545 S. INDIA RIVER DRIVE, FT. PIERCE, FL 34982
Notes:
Design Information
Fort Pierce, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75
Design TD °F28 Design TD °F15Daily range M
Relative humidity %50Moisture difference gr/lb61
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh8065 Structure Btuh10700
Ducts Btuh1183 Ducts Btuh1742Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0
(none) (none)Humidification Btuh0 Blower Btuh0
Piping Btuh0Equipment load Btuh9247 Use manufacturer's data n
Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11820
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average0Fireplaces Structure Btuh1198
Ducts Btuh447Central vent (0 cfm) Btuh0
CoolingHeating (none)398398Area (ft²) Equipment latent load Btuh1645
35823582Volume (ft³)Air changes/hour 0.320.61 Equipment Total Load (Sen+Lat)Btuh13465
Equiv. AVF (cfm) 1936 Req. total capacity at 0.70 SHR ton1.4
Heating Equipment Summary Cooling Equipment Summary
Make MITSUBISHI Make MITSUBISHITrade Trade
Model MXZ-3C24NA2 Cond MXZ-3C24NA2AHRI ref Coil MSZ-GL09+MSZ-GL09F
AHRI refEfficiency 9.8 HSPF Efficiency 13.6 EER, 20 SEER
Heating input Sensible cooling Btuh15400Heating output Btuh @ 47°F15800 Latent cooling Btuh6600
Temperature rise °F28 Total cooling Btuh22000Actual air flow cfm520 Actual air flow cfm520
Air flow factor cfm/Btuh0.056 Air flow factor cfm/Btuh0.042Static pressure in H2O0 Static pressure in H2O0
Space thermostat Load sensible heat ratio 0.88Capacity balance point = 30 °F
Backup:Input = 3 kW, Output = 9023 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Nov-13 07:23:03Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1...CK\Documents\Wrightsoft HVAC\CROW, CHARLENE.rup Calc = MJ8 Front Door faces: N
Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM
1 Room name Entire House ROOM
2 Exposed wall 104.0 ft 104.0 ft
3 Room height 9.0 ft 9.0 heat/coolft
4 Room dimensions ft398.0x1.0
5 Room area 398.0 ft²398.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 108 108 275 211 108 108 275 211
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 90 90 229 176 90 90 229 176
.WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 234 234 596 458 234 234 596 458
.WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 234 184 469 360 234 184 469 360
11 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 84.3684.36 9 1 320 759 9 1 320 759
GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 87.0687.06 20 1 711 1741 20 1 711 1741
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 21 21 229 217 21 21 229 217
PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 270 270 688 285 270 270 688 285
CC 16B-19ad16B-19ad 0.0490.049 --1.371.37 2.452.45 398 398 546 975 398 398 546 975
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 398 104 2880 0 398 104 2880 0
6 c) AED excursion 1342 1342
Envelope loss/gain 6944 6525 6944 6525
12 a) Infiltration 1121 315 1121 315
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 2 460 2 460
Appliances/other 3400 3400
Subtotal (lines 6 to 13)8065 10700 8065 10700
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 8065 10700 8065 10700
15 Duct loads 15%16%1183 1742 15%16%1183 1742
Total room load 9247 12442 9247 12442
Air required (cfm)Air required (cfm)520 520 520 520