Loading...
HomeMy WebLinkAboutAPPROVED PA FL5259-R29 .. ... . ..'.. ...... V BCFS Home . Log In User Reglstratim . Hot Tapirs Submit Surcharge Stats&Facts Publications Cortact Us SCiS Site Map Links Search db'pr �� � USER:Public User Producl Aooroval Menu Pro uCt or Application Search>Anolicatlon Lisa>Application Detail i FL# FL5259-R29 . ..........:...._.:..:_.,........................ : Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer PCLYGiASS USA Address/Phone/Emall 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext242 rnalpert@polyg lass.corn Authorized Signature Maury Alpert rna[pert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (666)802-SO17 uspolyg lasstechnica I @polyglass.com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyg lasstechn ical@ po lyg lass.corn Category Roofing Subcateg ory U nderlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-h'arcicopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL5 R7;_(--Oj2019 01 Ci .1 NIEMINEN.D�jf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2008 ASTM D6509 2009 FM 4474 2011 FRSA/TRI April 2012 2012 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option is Date Submitted 10/15/2019 Date Validated 10/16/2019 Date Pending FBC Approval 10/20/2019 Date Approved 1 2/1 012 019 Surrlmar of Products FL 9 Model,Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R29 IT 2019_10 FINAL ER POL~YgLA$S UNDERLAYMENTS FI 52 - { Approved for use outside HVHZ: Yes $29—Pd-f Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular FL5259 R29 AE 2019_.1QFINAL ER POLYGLASS_ NDE T _FED underlayment system (over concrete deck) R29.odf for use under foam-on the systems(where Created by Independent Third Party: Yes the underlayment forms part of the load- path). Refer to ER Section 5.6.1 for other systems,other deck types and associated maximum design pressures. 2.) Refer to FR Section 5 for other limits of use. Sack next Contact Us::26C1 Blair Stone Road,Tallahassee FL 32392 Phone:V"R7-1824 The State of Florida is an AAJEEO employer.fgoyrloh 20 7-201 f Florida-::Privil Statement::Accessibility Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditiorai mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,llcensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one,The emaiis provided may be used for official communication with the licensee.Hawever email addresses are public record-If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you area IiCensee under Chapter 455,F.S.,please click here_ Product Approval Accepts! Credit Card Safe NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATIRT s • � Polyglass USA, Inc. Evaluation Report P12060.02.09-R25 1111 West Newport Center Drive FL5259-R29 Deerfield Beach, FL 33442 Date of Issuance:02/24/2009 (954)233-1230 Revision 25:10/14/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2017)Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO Ietc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Evaluation Report consists of pages 1 through 16. Prepared by' �,,., �t_ Robert J.M. Nieminen, P.E. Florida Registration No.59165, Florida DC4 ANE1983 _W" ` The facsimile seal appearing was authortzed by Robert Nieminen,P.E.on 10/1412019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: I. NEMOietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc_is not owned,operated or controlled by any company manufacturing or distributing products it evaluates_ 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building cocie evaluation. Neither MEMO i etc. nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ( 2019 N E M 0 ETC,LLC ((4)NEM0 j etc. ROOFING COmPONENTEVALUATION 1. SCOPE: Product Category: Roofing Su b-Category: U nderiayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the fallowing sections of the 61h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations Conditions of Use set forth herein. 2. STANDARDS: Section Fro a Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 1507.1.1 Physical Properties A5TM D226 2009 1507.2.4 1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM 06163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Referenre Date Enti�t i Examination Reference Date ERD MT 6049) Wind Uplift 11757-08.01-1 08/13/2001 ERD{TST 60491 Tensile adhesion P40390.04.15 04/03/2015 ERD(TST 6049) Wind Uplift 11776.06-02 D1/16/2003 ERD(TST 6049) TAS 103 P44360.10.14-111 05/18/2015 ERD(T57 6D49) Wind Uplift P1740.01.07 01/04/20D7 ERD(TST 6049) Wind Uplift PLYG-SC8905.05A6-1 05/17/2016 ERD(TST 6049) ASTM D1970 P5110-04.07-1 04/11/7007 ERD(TST 6049) ASTM D1970 PLYG-5C10130.116.16-1 D6127/2016 ERD{TST 6049) wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Tensile adhesion PLYG-SC1D130.06.16-2 06/27/2016 ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 ERD(TST 6049) TA5103 PLYG-SC10130.06.16-3 06/27/2016 ERD(TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD(TST 6049) ASTM D1970/04198 PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift P11030AL09-2 11/30/2009 ERD(TST 6049) Wlnd Uplift PLYG-SC12025.10-16 10/12/2016 ERD(TST 5049) ASTM D49T7 P11030.11.09-3 11/30/2009 ERD(TST 6049) TAS 103 PLYG-SC1304C.12.16 12/27/2016 ERO MT5049) ASTM D1970 P33360-06.10 06/25/2010 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017 ERD(TST 6049) TAS 103 P33370.03.11 03/02/2011 ERD(TST 6049) TA5103 PLYG-SC12115.08A7 09/09/2017 ERD(r5T 5D49) Tensile Adhesion P33370.04.11 04/26/2011 ERD(TST 60d9) TAS 103 PLYG-SC13035.08.17 10I31/2017 ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 FM(TST 1867) Wind Uplift 3004092 01/12/2000 ERU(TST 6049) TAS 103 P40390.08.12-1 08/06/2012 ICC-ES(EVIL 2396) 16C Compliance ESR-1697 04/01/2019 ERO(TST 6049) Tensile Adhesion P40390.08.12-2 08/07/2012 M-D(CER 1592) HVHZ Complf8nce NOA 17-0614.22 07/06/2017 ERD(TST 6049) Tensi[e Adhesian C41420.09.12-3 09/11/2012 MTI(TST2508) ASTM 04798 JX20P7A 04/01/2008 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMD(TST 6049) ASTM D197C 4-PLYG-18-004.03.18 03/29/2018 ERD(TST 6049) ASTM D1970 P45370.04.13 C4/26/2U13 NEMD(TST 6049) Wind Uplift 41--PLYG-18-003.01.19 01/11/2019 FRO(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 NEMD(TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A OV2412019 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEMD(TST 6049) ASTM D6222 4S-PLYG-18-002-05.19-C 05/20/2019 ERD(TST 6049) ASTM D6164 P37590.03.13-3A O5/06/2013 NEMD(TST 6049) TA5103 4S-PLYG-18-004.10.19-G 10/08/2019 ERD W 6049) ASTM D6509 P3759D.03.13-1-RI 06/26/2013 NEMD(TST 6049) TAS 103 4S-PLYG-18-004.10.19-1 10/080019 ERD{TST 6049) Wind Uplift P41630-08.13 08/06/2013 N ERA D(TST 6049) TAS 103 4S-PLYG-18-0D4.10.19-L 10/D9/2019 ERD(TST 6049) A5TM D4601 P45940.09.13 09/04/2013 NEMO(TST 6049) TA5103 4j-PLYG-19-551117E-01.A 10/10/21)19 ERD(75T 6049) Wind Uplift P11751.05.03-R1 11/26/2013 PRI(TST.5878) Tensile Adhesion PRIC1111 04/08/2002 ERD(TST 60491 Wind Uplift P11781.11.03-R1 11/26/2013 PRI(TST 5878) TAS 1.03 PUSA-018-02-01 07/1412003 ERD(TST 6049) 3M90 physicals P45270.05.14 05/12/2014 PRI(TST 5878) TAS 103 PUSA-035-02-01 09/29/2006 ERD(TST6C49) Tensile adhesion 6020.09AII-5 09/08/2014 PRf(7ST5878) TA5103 PUSA--055-02-02 12/10/2007 ERD(TST6049) Tensile adhesion 6020-09.14-6 09/08/2014 PRI(TST 5878) ASTM D6222 PUSA-061-02-02 01/29/2008 ERD(TST 6049) Tensile adhesion P46520.10.14 i0/D3/2014 PRI(TST 5878) ASTM❑6164 PUSA-088-02-01 (17/29/2009 ERD(TST 6049) ASTM D1970ID4798 P43290.10.14 10/17/2014 Polyglass USA P/L Affidavit Mule-Hide Crass Ltg 03/01/2008 NEMD ETC,LM Evaluation Report P12060.02.09-1325 Ceftifrcote of Authorization f132455 a EDITION(2017)FUC NON-HVPIS EVALUATION FL5259-1129 Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019 Dojo 7!.r I. U(4 NEMO I etc. En i Examination Reference Date End Examination Reference Bate ERD UST 6049} TAS 103 FLYG-50550.03.15 03J24/2015 Polyglass USA M ate JaIs Affidavit Polystick Compound 08/18/2011 LL(QUA9625) Quality Control Service Confirmation 09/13/2018 4; PRODUCT DESCRIPTION: Product Specification Plant(s) Description 4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet 4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet 4.3 Elastoflex G TU M-D 13-004 PA Polyester-reinforced,modified bitumen tile underlayment FRSA/TRI April 2012 composed of a sand-surfaced SBS modified bitumen back- side and granule-surfaced APP modified bitumen top-side 4.4 Elastoflex S6 G ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet FRSA/TRI April 2012 4.5 Elastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet FRSA/TRI April 2012 4.6 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.7 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane,fiberglass reinforced,with a polyester fabric surface 4.9 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt TAS 103 waterproofing membrane,fiberglass reinforced,with a FRSA/TRI April 2012 polyester fabric surface 4.9 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet (FR) FRSA/TRI April 2012 410 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the "Two Ply System"from FRSA/TRl April 2012(04-12) beneath mechanically fastened or adhered tile roof systems 4.11 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the "Two Ply System"from FRSA/TRl April 2012(04-12) beneath mechanically fastened tile roof systems 4.12 Polyflex SA P ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.13 Polyflex SA P FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.14 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet 4.15 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet 4.16 Polystick IR-Xe ASTM ❑1970 FL,PA Nominal 50-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface 4.17 Polystick MTS Plus TAS 103 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane,glass fiber reinforced,surfaced with polyolefinic film surface NEW ETC,LLC. Evaluation Report P12060.02.09-R25 Certificate of Authorization 432455 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FLS259-R29 Polyglass Roof underlayments;(954)233-1Z30 Revision 25:10/14/2019 -7-F I 6T0Z/VT/ol:sz ua!swu om-tzz lose}`nvowRelaapun pus ssepAlod 6ZH-Gszslj MOIIVfIIVA3 Z14AN-MON XH U 10Z)NOf1F03 ..9 SSPZfq-'Ju4-wfiv G d=Aftya7 5Zl1-6070'090Zid YWoday aOPENU3 '111'a)3 OlNJN saA saA ON ON ON Sax a 21!�lagsA{od SOA saA ON {;-S•S aa5} saA Salk SaA f W d VS-DA10d saA saA ON (T-S•s aas) $aA saA 50A d dS 13Aind saA saA ON ON Salk Salk w 9 xnPlod saA saA ON (T,s'Saas) SaA sft saA !DWlA!Od saA saA ON (T'S'S aas) saA saA saA 1 de7 ddV-VS eP!H-alnA saA Salk ON (UVSaas} saA saA saA 3a i dea ddV-vs ap!H-ajny4ON1 saA saA saA ZT-S'S aaS) saA saA saA j oad qU pienqet H saA saA saA ON ON saA wd lend pang saA saA ON ON saA saA ! - 13j J 9S xaUo;M3 saA saA ON (I-S-s aag) saA saA saA 9 95 xaUo0e0 saA saA ON (Z'S's aas) $aA saA saA nj 9 xagoxsel3 {walsAs d!d-Z�aas aseg} {maysls,6!e-z v!1aay4.ases] ON ON ON saA saA ON aaag ZJ sse12410d {waists A!tl-2�!1aay5 aseg) {11hrCAt h!d-Z�Saai35�es1 ON ON ON ERA saA ON aseg ssptgAlOd saA saA saA {warms Ada- Saays aseg) iuealsrts/!d SaSaa�s aseg] saA d asEgo;sE{3 SBA CIA sah calk twalsAs Ald-Z In 3aatL5 rise] (a.J L5 AEdZ q 1m)gS aseg) saA asegols�!g saA saA alels le7aw al!juO-weo3 alLup-HUN salBulyslIe4dsv 3uausAepapun sasleyS pooM SNOUJO MAOD 30011 =I MV L :sa5nu3155H algefAolIV S'S 'puuaApa lava pasedaad aq;jal e;ep Rutpoddns 41!m paulgwo3 uagenlena s!qz uo paseq jenoidde ao;uopips1in€llujneH AllaoglnV aqT a;apew aq Am lsentaa t a'Pais!];ou 11 -s;uaurrrsop leAo.ldde:)qj ulq;lAa panwala!A1juz!;pads sl;anpoid aq;a,laqm jaAra loon pajedaad Aue q)jm pasn ag Aew s;uaiuAepapu fl you sselSAIOd tr'S •pnpwd srq; 10 s2ul;ea aal;joj Ajopaa!❑sleuelew Rugoakj paAnjddd;uaaana o;ja;ai'liodad u014enjeA3 slq;to aaed IOU sl uol;ealjlsseID aalj E's -Z)jAH ail;u]asn ac4 iou 51:Wodad uojlenjeA3 Slgi Z-s -asadind;Etl;.aol Aljeayl3ads pautezai ssalun aauepinO Olsap io 2url;lwaad ao} pasn seen/s€ pajaq; suolsieA snolAa td ao ':podaa uogEnjeA3 slg4 ga)ynn uu ;aaloid rtue�v paoaa�j�°eau�lsaO aq;'Aenn AuE ul`aae 3 d'uaulwalN;sago}}eau 3;a IDl/V3N Jay;laN -uot;enleAa epoa Zulpl!nq a sl sjgi I'S -SNouv.Lllwlj aaepns ZTOZ IljdV Il1.1NSHj 3ugt2l as;saAlad a 4vm'paasolula.t�aql}sselO`auujgwaw £ol SVi 2u13floidaa4em;legdse pazlJaggnj�ojq;pw-OS leulwoN Vd 1:1 OL610 iNISV sold.hi.5PRA. Iny eoepns aelnUEJO e 41!A&1paaaojulaa as;soAjod faagU-ssej2'aueagwaw ZTOZ I!AdV 18i/VSHj supoadaa;Em llegdse pazljaggna piq;yw-OCT IeulwoN XL lEoT sVi d f1i j311sAIOd OZ'1? ZTOZ Ilid'v IN.Llm:j a3epns ajTge;ja;saAlod zw/,W Ohl a q;!m auelgwaw EOT SV-L ifugAoidaalem IIE!gdse pazuaggru jalq;liw-Q9 leulwoN X-L`Vd'l3 01610 W_Lsv xeW ill pllsAlod 61.11 anpns uujq oualAdoid/god e q;lM'paaaa}ulai ssEj2aagy'auelgwaw Ougoosdjairm (g'S uo!pas aas) llegdsu pazljaggnj jaAel-lenp j31q;I!uj-VS leuluaoN Vd'AN` J OL6T(3 AiSV X-f1W 1311SA1od ST'b uondlaasau (sAu>'Id uolleaylaads pnpOJd :N0tJ.alS3s3q ianaoHd •jp 7L at-]—,a 6TOZ/VT/OT:S Z uolslnad oEZT-EEZ(tis6)'.sjuawAe[aapvn ioou sse]SA[od 6Zd-6SU14 N011Vn1VA3 ZHAH-NON J8j(LTOZ)N011103 w9 SS7Z£N uarlonlat{anV fo a$oa r2fa7 WM-6070'09071d;rodad uogenleA3 'ill'313 0IW3N '2auncua0frada�un;sjsay;uaujokv6uiufMJanoJojrnAorddympald aArsagpyroVa-MPO UDMIalllo;aaAVr aseg 5sel5Alod ao ase8 Zg 3aays sselEAlod'aseg ITN aP[H-alnIN'd asego;se13'aseg0;se13 VAN aseg p gdde seog pod as wnsdA 7Ia0dnAS ao awiad 3aa0sua euo!;do) uol;elnsu[ -goaol ul xallAlod uo g xal)Alad a;aaouoo leanaanils Tb0 WlSV Aaa0 aseg Zg sselgAlod ao aseg V/N ;aag5 HEN ap!H-aln W'd osego;sel3'asego1se13';la}gZZO W1Sd aseg ;leydse 104 d j g 9S x3l}a1se13 jo g 9S paeog load jaglj-wnsdRg]1gOuflg35ao awl.ld Aoa05ua0 it,(]WiSV(leupl;do) uo!lelnsul xal}0;se13'n-L D xallflasel3 a;aaauoo lean;onjas Itr0 W15V laaa aseg REN aaagS aplH-aInVH ad d asegolsel3'asego;se13`llal gZZa W1.SV tf�N ase8 xa d lu xal lja of d VS deD paeog loon aaglj-wnsdAi)71�oullg3s ap owud xa-VS a '[g3};aag5 WS O00£-eM jp dd'd-VS ap1H-ain W`aaauS vapsuaa`aa!sadwoa-a;eanueAooslAlodAadA} 6gZL3 upl;elnsu[ u�aayPe TtrCI W-Lsv(leuo!;do) deb ddV-VS aP!H-91nN KiSV'aaeanueAooslA{od T sse13 II adA.L69ZQ W1SV -lias '(su0l;elJCA IIe)V14SAIOd alaaau03 leanlan.gs 1170 W1Sd Eulyleags 'oad ol!1 paengeapAH Slaued„waISAS dIZ,.SpooM PaaaaulEu3 Tb0 iN_LS'd(leucpdp) 13a❑ OJd lend piengeapAH Aaq n H ao awd m011aA uaaq;nOS'8S0'poomAld (s)lelaa;ew uawl.ld adAl uolmllddv auawAepapun (loafoad aol speol pulm;aaw o;psuElsap)sa;ea;sgn5 SiN3WAV17330N f1103d3HUV M03 SN01"o alvdisanS :Z 318tlJ. :sa;e.l4sgnsalgemolly 9'S snld n-LPlasAlad as d niND!asAlod'xeLN n-Lr!3sAlpd %A d VS xal}Alod'd VS xal]+lod'E)xalJ'lod'{ul)aaagS de-]ddV-VS aP!H 9LZ91j I-Vlu®lasAlOd sanlsagPV d:)[ -alnvq';aagS d eg dd V-VS aP!H-al n W'aud al!1 pa en!)eapAH'!)9S xa140;3eI3 snId fll�a!aSAlod ao d ni�a[;sAlod`xeW n-L dal;SAJOd`HA d VS xaIlAlOd d VS xaVlod'J xallAlod`{d j)aaagS deb ddV-VS ap!H-afn[j';aagS deZ) Z££913 09T-HV.�,) A)od SaAlsagpV d71 ddV-VS ap!H-alnVV'Oad ala paengeapAH'g 9S xal}oase0'fU g xalla;se3 snld Ill INTSAlod SZ5ZZl3 ,„.puogal!l Moo JO d n-L 13115A10d'xeW f)-L l01as*d'd VS xallAlod`pad alli piengeapAH Sn d fll�:)'TsA o ao xe n1 xu!1FA 0 anlsagpV al!i}oou I I d W d 905trI�j pu0gwols leas u,yunol we0j dV0 s;uawAelaapun IenoaddV anisagpd lonpoud epiJalj rSNOLLVNIUM031N3WKVTH30Nn/3AIS3HOd 3111316VM011d:VT 318V1 -sual;eulgwoa Tuaw4el ,3pun J S0Als0gpe all}panoaddV Sulmollo}ayl}O asn of pallwll sl,.al!i up-weOI„ T'S'S saA saA saA (T'S'S�s) -AsaA saA sold fll�!al35Alod ON ON ON {T'S's aag) sax saA ON d nislallsA[Od ON ON saA {T'S'S aas) saA saA ON xeW n.LNolasAlod saA 5aA saA ❑N oN saA x-nw japsAlod saA saA saA ON saA saA snld S1W PP Alod awls sal2ul4s Is le1.aw a I a uO-weoj alli u0-1leN sa[8u!gs:[e4dsV luawAelaapun sa>legs POOH sN0llapd3n0J300a :Talstll (NNEMOJetc. 5.6.1 Wind Resistance for Underlayment Systems in Foam-On Tile Applications_ The following wind uplift limitations apply to underlayrnent systems that are not prescriptively addressed in FRSA/TRI April 2012(04-12)and are used in foam-on or mortar-set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FSC 1504,9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #t1 Maximum Design Pressure=-52.5 psf: Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,CISB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Joints: Min.flinch wide strips of Elastoflex SA-V over all OSSjoints Base Ply: Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered_ #2 Maximum Design Pressure=-90 Psf: Deck: Min,15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Muie-Hide SA-APP Cap Sheet(FR),Polyflex 5A P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self adhered. #3 Maximum Design Pressure--97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet[FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered and hack-nailed within the selvedge-edge side laps using 12 ga,x 1J"ring shank nails through 32 ga_,1-5/8"diameter tin caps spaced 12-inch o.c. #4 _Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Laving Jurisdiction. Primer: WB-30co Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or PolystickTU Pius,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga,x 1%"ring shank nails through 32 ga_,1-5/8"diameter tin caps spaced 12-inch o.c. 415 Maximum design Pressure=-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Joints: Min.4-inch wide strips of Eiastoflex SA-V over all plywood joints. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or PolystickTU Plus,self-adhered. #6 Maximum Design Pressure=-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PC 100 or ASTM D41 Base Ply: [Optional)Polystick MTS Plus,self-adhered. Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #7 Maximum Design Pressure=-622.5 psf: Deck: Structural concrete to meet project require ments to satisfaction ofAuthor'rty Having Jurisdiction. Primer: PC 100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch- applied-MEMO ETC,LLC Evaluation Report P12060.02.09-R25 Certifitote Of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019 (NNEM0 I etc. 48 _Maximum Design Pressure=-30.0 vsf*: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Bail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch oz.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or PolystickTU Plus,self-adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch c-c.attwo(2)equally spaced staggered center rows_ Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or PolystickTU Plus,self-adhered. ##10 Maximum Design Pressure=-37.5 psf*: Deck- Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type Il felt Fasteners: 11 ga.x 1,25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c,atthe 3-inch wide side laps and 12-Inch o.c.attwo(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #11 Maximum Design Pressure=-45 sf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)IayerASTM D225,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch c.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or PolystickTU Plus,self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt. 412 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.atthe 2-Inch wide side laps and 9-inch o.c.attwo(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self adhering underlayment only)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or PolystickTU Plus,self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #13 Maximum Design Pressure=-45 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAxX Cap Fasteners Spacing: 9-inch o.c.atthe 2-inch wide side laps and 18-inch o.c.attwo(2)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-45.D psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diametertin caps Spacing: 6-inch c.c,atthe 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P cr PolystickTU Plus,self adhered. NE€ G ETC,LLC. Evaluation Report P22060.02.09-R25 Certipcote ofAuthorization#32455 6m Mill(2017]FBC NON-HVHZ EVALUATION F1.5259-1129 Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019 P�nn 7 of�- (NNEMOJetc. #15 Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diametertin caps Spacing: &-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows_ Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #16 Maximum Design Pressure--45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Fxposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underfayment: Polyflex G,torch-applied. #17 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet. Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-Inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex SG G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #18 Maximum Design Pressure=-52.5 psf: Deck: Min,15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (optional)Polystick RATS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,PolystickTU Max,Polystick TU P or PclystickTU Plus,self-adhered. #19 _Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch c.c.at the 3-inch wide side laps and 6-inch o.c,at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #20 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded tap surface for hot-asphalt ortorch-applied cap or poly-film surface fortorch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch O.C.at the 4-inch wide side laps and 8-Inch o.c,at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied_ #21 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt ortorch-applied cap or poly-film surface fortorch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex G Tl1 or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. NEMO ETC,LLC. Evaluation Report P12060.02.09-R25 Certlficote ofRuthonzatw#32455 91 EDITION(2017}FSC NON-HVH2 EVALUATION FL5259-1129 Polyglass Roof Underl ayme nts;(954)233-1230 Revision 25:10/14/2019 oano 2-f I a (NNEMOJetC. 422 Maximum Design Pressure=-60.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P, Polyflex SA P FR,Polystick TU Max,Polystick TU P or PolystickTU Plus,self-adhered. #23 Maximum Design Pressure=-60.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXI[Cap Fasteners Spacing: 8-inch o.c,at the 3-inch wide side laps and 8-Inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 924 _Maximum Design Pressure=-60.0 psf: Deck: APA rated,7116 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch c.c.at three(3)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #25 _Maximum Design Pressure=-67.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(regurres use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3J8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #26 _Maximum Design Pressure=-67.5 psf: Deck: APA rated,19/32 CAT,0.578 in,,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nall Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.atthe 4-inch wide side laps and 12-inch o,c.at two(2)equally spaced staggered center rows. Primer: (Optional)RG100 orASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex 5A P FR,Polystick TU Max,Polystick TU P or PalystickTU Plus,self-adhered. 427 Maximum Design Pressure=-67.5 psf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch❑.c,at the 4-inch wide side taps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt. NEW ETC,LLG Evaluation Report P12060.02.09-R25 Certrfkate of A uthormoftn#32455 6—EDITION(2011)FSC NON-HVH2 EVALUATION FL5259•R29 Polyglass Roof Underlayments,(954)233-1230 Revision 25:10/14/2019 (NNEMOletc. #23 Maximum Desilzn Pressure=-67.5 sf: Deck: APA rated,19/32 CAT,C-579 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the flinch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #29 Maximum Design Pressure=-75 psf: Deck: Min.15/32-inch plywood to meet project requlrementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underfoyment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG 414 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underiayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #30 Maximum Design Pressure=-90 sf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sandedtop surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c.at the 2-inch wide side laps and 6-inch o.c,at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applled- #31 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap) Fasteners- OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch c.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 432 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the flinch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hot asphalt. #33 Maximum Design Pressure=-90 sf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with CMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTraC),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.atfour(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt ortorch-applied or Polyflex G,torch-applied. #34 Maximum Design Pressure=-90.0 sf: Deck- APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathingto meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.atthe 2-inch wide side laps and 12-inch o.c.attwo(2)equally spaced staggered center rows. Primer: PG100 crASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,PolystickTU Max,Polystick TU P or PolystickTU Plus,self-adhered. MEMO ETC,LtC. Evaluation Report P12060.02.09-R25 Certlficcte ofAuthofization032455 6 EDITION(2017)FSC NOR-HVH7 EVALUATION FL5259-R29 Polyglass Roof Underlayments,(954)233-1230 Revision 25.10/14/2019 NEMO I etc. #35 Maximum Design Pressure=-90.0 psf: Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,0S0 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes ofthe plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.attwo(2)equallyspaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. #36 Maximum Design Pressure=-90.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&PIates with two(2)screws per plate installed 190`into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied_ 437 Maximum Design Pressure=-97.5 psf: Deck: Min.19/32-inch plywood tc meet project requirements to satisfaction of Authority Having Jurisdiction_ Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PoiystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered. #38 Maximum Design Pressure=-97.5 psf: Deck: APA rated,19/32 CAT,0,578 in_,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Bide Nail Base(poly-film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch c.c.at four(4)equally spaced staggered center rows_ Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,PolystickTU Max,Polystick TU P or PclystickTU Plus,self-adhered. #39 Maximum Design Pressure=-97.5 psf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,0513 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-1[nch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex SG G,applied in full mopping of hot asphalt. #4C Maximum Design Pressure=-97.5 psf: Deck: APA rated,19/32 CAT,4.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the flinch wide side laps and 5-inch o.c.at four(4)equally spaced staggered center rows. Urderlayment: Polyflex G,torch-applied. #41 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt ortcrch-applied cap or poly-film surface fortorch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-Inch o.c.atthree(3)equally spaced staggered center rows. Urderlayment:Elastoflex G TU or Elastoflex S6 G,applied in full moppingof hot asphalt or Polyflex G,torch-applied. NEW ETC,Ill Evaluation Report P12060.02.09-R2S Certr'frcote afAuthorizatton#32455 CH EDITION(2017)F9C NON-HUH2 EVALUATION F1,5259-Il Polyglass Ill Underlayments;(954)Z33-1230 Revision 25:10/14/2019 Pine 1 1 nF 9 G UN DEMO I etc. #42 Maximum Design Pressure=-105.0 psf: Deck: APA rated,7/16 CAT,0,419 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 4 inch wide side laps and 6-Inch o_c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTtJ Max,Polystick TU P or PolystickTLJ Plus,self-adhered. #43 Maximum Design Pressure=-105.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,aSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate, parallel to the width-direction of the sheet Spacing: 6-inch o.c,at the 4-'Inch wide side laps and 6-inch o,c.at three(3)equally spaced staggered center rows. Under€ayrnent:Elastoflex G TU or Elastoflex S5 G,applied in full mopping of hat asphalt. #44 Maximum Design Pressure=-105.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to the width-direction ofthe sheet Spacing: 6-inch o.c,at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. ##45 Maximum Design Pressure=-112.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide NaC Base(poly-film top surface) Fasteners: 11 ga,x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 6-Inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-Caps Base Ply: Polystick MTS Plus,self-adhered Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex 5A P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or PolystickTU Plus,self-adhered. f#46 Maximurn Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap) Fasteners: OMG 412 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.atthe 4-inch wide side laps and 6-inch o.c.atfiee(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastaflex S6 G,applied in full mopping of hot asphaltor Polyflex G,torch-applied. #47 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction_ Base Sheet. Elastobase(sanded top surface) Fasteners: Trufast 912 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the flinch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows, Underlayment: Elastoflex G TU or Elastoflex$6 G,applied in full mopping of hot asphalt, NEMO ETC,LLC, Evaluation Report P12060.02.09-R25 Certificate of.AuthorizationY32455 6-EDIFION(7017)FBCNON-HVH2EVALUATION fL5259-R29 Polyglass Roof Llnderlayments;(954)233-1230 Revision 25:10/14/2019 Daero'1 7,.F 9 G y�3"Gi a.cG 6TOZ/bL/OT'SZ ualsiAad ou-r-EEZ(m)`slueLuAEw)pun#auu sselBAlod 6Z21-6sZslJ NouvnivmZHAH-NON38d U104 NOISlil3,9 590FENuorlon�o{7nb�aalna�rlfa3 SZa-607O'090Zid lrodab u011enleA3 •JTI`.)13 OW3N •aoue;s!sau digs of se pags!jge;sa aq pinogs`ST-OL6Tp WlSV 10 Z a;oN 'E•,tr uolgaaS ut qwo;;as se '.:alias pue Aasego.md uaanAjaq ;uaw;a By •suOq!puoa A.:oleaogel piepue;s ;e pa;sa;'uol;!puoo AAp e u! 41,94 $u!Jo0A 9ZZp WlStl uegl u0!:P!u j 10 Wa[44003 aassal a aneq o;gu!;so;eA!leJedwaa gBnoaq; punol uaaq seq x-fIW)o!;sA(od 8'5 (SiaAw jow paiedaid Jooa paualse}Al!e3tueguauuao;) ❑311W IlNn NH d VS xaVAiod�o d VS xaIJAlod'W D xal}Alod'J xaIJAIOd'Tli3) (al!;las-anlsagpe 1aaU deO dd'd-VS aP!H-ainW'1aagS deD ddV-VS aP!H-alnW`lid!)9S xaI}oise13 J 9S xajjolsel3 09T 0E aseg sselUAlad.Io aseg Zq sseINAlod'd asega4se0'asegoisel3 06 X-M�o!;sAlad as aX-111 I3!1sA10d 081 snld n-L ADIISA106 JO d nl�:)IjSAlod'xeNl n-L r3!1sA!od'snid S1VV A-J!1sAlod'OJd 91!1 PJIME PAH'oad lenQ pJenDEJPAH'n-L 9 xagOlsel3 (sAep)aansodx3 wnw!xeW ;uawAelaapun sNouvim17 gimsodx3 :lt alaVl :sua!xellwl-1 aanso x3 L'S •s;uawaWequa£/Z auOZ uol(9TOZ Ajenuef)U-T;aa45 e;e❑ uol;uanaJd.ssol Wd fo T'oT'Z'Z ua!aaaS u!quo}1as suo!1e;lwil aq; Alaeo �ispaise ue q1!m paIjew sa!lgwassd 'ITT 5tl8 p ppue;g uol;ea!lddV gu!}ooa pue 6Z-1 1@a)% e;e❑ u01Juanaad ssol VYJ 'TCM llid5/ISNV a.Ie spoglaw pasn Aluowwo:) •epalpo wrnssaad pawala agj;s!saj o; !eu0!ssopid u2isap pa�ipenb e Aq pau�isap A}!suap ;uawgae;ie ue Aoldwa I1egs E pue Z sauoZ 'aseg s!41 ul '6091 393 g1!nn aouepioaoe ui pomwia;ap aunssaid u2isap T auoZ aq1 paaaxa.lo jaaw Ilegs Algwasse pav,?Ias aq1 aol aunssigid u9!sap wnus!xew aq; 'Alan!;eu,Ia;ly -VT aigel'yx!puaddv'(ZT-t0)ZTOZ 1!-ldb'1-8l/dSUi .aapun paa!nba. ;eql pa@oxa JO;aaw !)eqs Alqulasse paaaa!as aq;ao} aanssaid uS!sap uunw!xew aq; ';aags @sea pagae;;e Alleo!uegoaw ao3 Z-T'9'S -Isd Sb-Jo e-Inssald Ajsa❑ ulnw!xeVy a Aaaeo swa;sAs ap uo-weo; q;eauaq swa;sk ;uawAepapun ssel2AIOd paaaype 'Vap-:PaJ!p Jaq;o IN T-T'9'9 •pa!ldde-goao;`g xal jAlod:;uawAep'3pun •smaa aalua3 pwaHns paaeds Allenba(t,)inaj;e•a•o pu!-6 pue sdel apls ap1m qau!-b aq;ie•ao qou!-6 :8u{aeds •a!oq aaluao aq1 ul'aleld lad maws(1)aua q;!vn saleld 13 saaua;se3;sej-MaA 1SVJnd-L :sIauaise3 aseg sse!2Alod uo asego;5e13 :;aagS ase!3 •uo!la!psljn f duMH Alljoq;nd;o uol;aejsl;es of sw;)wannbaj;aafoad laaw ol2u!q;eags 9So`j wnsodx3"ul SLS'0`l'd0 Zs/6I'Paler VdG :Naa❑ :}s S-LZT-=aumSSWd u !saq wnw!xeVy ()S## 'l!egdse loq;o 8u!ddow Iln;u!pa!Idde'g gS xal4olsel,ao n19 xal jo;sell auawAelaapun •sneoj,ja;ua3 paaaggels paoeds Allenba(ti)inoi;e•3•o put-6 pue sdel ap!s appea qau!-t,agi4e-o'o qau!-6 :2umeds •aloq ualuao aq1 u!'a;eld jad nuns(1)auo Um saleld 28 saaua;sej;se3-maA lsb'inui :Sjaua;Se4 (a3e}pns dot pues)asegolsel3 :hags aseg •uoip!ps!a n f 8u!AEH Al!aoginy;a ua!4-)ejs!les o;slu;waa!nbal iaafo id laaw ul gucq;eags 9So'T a.Insodxd'•u!SLS-O'LVD ZE/6' `palea Vdtl :43aO :}s S"LZI-=ajnssaud ulflSeCI uanw!xeW 6b# -paaagpe-jlas'snld n-L VIISAlod JO d n i N311SA10d WN nIV!1sAlad'lld d VS xa!#Alod`d vs xaliAlod'(lid)laagS dea ddd-VS aP!H-a1nW'laagS de:)dd'd-VS aP!H-alnvq:luawAelaapun -paJagpe-;las'snId SJ-ry VIISAlod(leu011do) :Aid aseg •saleld ssails o;pa!ldde iawud Fbb w_L5$V jo 00iDd aaw!Id -smog aa;uaa paaa2fe}s pa3eds Allenba(q)uno};e•o•o qau!-6 pue sdel apls apinA gaul-p ag1;e'a'0 pu!-6 :2upedS •alog aa41ja3 aq;ul'aleld lad nnaJoS(1)auo g1IM saleld 79 saaua;sed lsej-esJDA 1Sb'dnal :szaualsed (aujins do;ual!}-Arad)aseg IIeN aplH-alnvi ja asego;sel3 :;gags ases -uo!;a!pslinr SWAeH ANOLWIV}o uo!13e4S4e9 01 s;uawaimbai pafoid laaw of Puigleags 8S{a'T ainsodx3`'uj 8L5'0 1'd0 Z£/6T'palea'ddv ;�3a❑ }s 5'LZT-=aunssald u !sap wnw!xel,N 8!7# • Ow3N ~ (ONEMOletC. 5.9 Tile Slippage Limitations(FRSAITRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-decktile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMIiATiON5FOR DIREcr-DECK TILE INSTALLATIONS underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Fiat 10-tile stack 7:12 Lugged 8-tile stack(6 over 2) 6:12 Elastoflex 56 G or 56 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Polyflex G or FR Flat or Lugged 6-tile Stack(4 over 2) 4:12 Polyflex 5A P or 5A P FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polystick NITS Plus Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack(4 over 2) 4.12 Flat 6-tile stack(4 over 2)or 10-die stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 P4lystickTll P Flat 6-t1le stack(4 over 2) 6:12 Lugged 6-tile stack(4 over 2) 4:12 PolystickTU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 6. INSTALLAT)ON: 6.1 Polyglass Roof Llnderlayments shall be installed in accordance with Polyglass published installation requirements subject tothe Limitations set forth in Section 5 herein and the specifics noted below_ 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or Mule-Hide Nail Base: 6.3.1 Non-Tile Applications: Shalt be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBCTable 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Elastobase,flastubase P or Mule-Hide Nail Basc may be covered with a layer of Polystick.Polyflex SAP, Polyflex SA P FR, Mule- Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1, 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply Systern"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.1 herein,coupled with FRSAJTRI April 2412(04-12)Installation Manual. NEMo ETC,LLC. Evaluation Report P12060.02.09-R25 Certifirate ofAutharization#32455 6-EDMON(2017)FBC NON-HVH2 EVALLIATION FL5259-R29 Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2419 0320 7 n..f 4� YL 3v 5y vu ca 6iO4'IbI/OT:SLLJOISI ad O£ZT-EU(tS6)`wawAe1-Japun;oc%ssellAlud 6ZII'65Zslj NoiivnldA3 ZHAH-MON DU UTOZ)NOTSIC13 L,9 55pe"F#uw10'."OvIviv ain7�ipra� SU-6o'ZO'090ZLd 3lodab uopenlen3 '711'313 0W3N -swalsAs;ooj alll paualse;Allealueloaw yleauaq(ZT-tr0)ZTOZ I!adV ICI VSHj woa3„walsAS Aid omL,all ul„;aagS de0„palldde delft 101­1 aylao swalsAs;ooa all;paualse;Allealueyaaw yleauaq(ZT-VO)ZTOZ I!adV lbl/bSad Dual;�,uaalsAS Aid aigusS„ ayl u! (IIII sse10 'DSE9q W1SV) .,2ugoo`d Ilan awpns leJaullN„ 01 aleuaa;le ue se asn a04 s1 di 9 95 xaljo;se13 'swalsAs;ooa al!l paaalpe 10 paua;se;Allealueyaaw lleauaq(ZT-VO)ZTOZ I!-JdV IaI /VSil3 tu0-i;,walsAS Aid oML,04l u! „laayS deb„ palldde llegdsb loH all as swa;SAS 100.1 al!l paualsej Allealuegoaw yleauaq(ZT-to)(TOZ I!adtl 12i1/dSb3 ua0 „uaalsAS Ald VUIS„a41 ul(W sse10'08E90 WISV)„Oul}aab IlaU aoepnS IeJauIlN„01 aleuJalle UE se asn ao;sI 9 9S xa1401Se13 -swalsAs 400a al!l pwagpe ao paualsel Alje3luey3aw lleauaq(ZT-170)ZTOZ I!jdb'Ibl/VSb j uJO-4„w;);sAS Ald otAL,alll ui „laalS deb„palldde lle4dsV loH ayl as swalsAs JooJ a111 paualseJ Allealueyaaw yleauaq (ZT-VO)ZTOZ I!-IdV 1�11/dSa3 woa3 „Lua1sAS Ald alJuls„a41 ul(IN ssel3'OSE9❑ W1SV)„Ouipoa[lob aae}anS le.iaul[N„01 aleu.Ialle up se asn ao;sl[ll E)xal}olsel3 � :suol;earldde aI!l uI asn god -sluawaambai uol;ellelsul palsllgnd sselOAlod luaiina yl!M aaue[ldwoa ul pallelsu)aq Ileys dj J 9S xaljol5e13 J0 q 9S xal;olsel3 f119 xeljolsej3 T'S'9 :ad!]9S x3l;01se13 an 9 9S xal}O}sel3`n.L D xal;olsel3 S'9 'pa.slsap sl walsAs 1uauTAepapun Ald-Z e;!algemolle sl;nq'luawaa[nbaa e;ou si s141 'lepalew daAel-dol a44 44IM palpposse aso4l we asn po sl!wp *swalsAs all)IaS-aAlSaype japun asn So;algeMolle sl snld n-L IallsAlod JO d ni 1allsAlOd 'xm [ll �DgsAlad 'd VS xal Alod '03d aµl p3en9eIpAH Aq P9M01101 Snld 51W ja!lsA{0d •pajlsap s1 walsAS 1uawAelaapun Ald-Z e;! e[geMolle sl;nq ';uawaimbaa a lou sI sill -lepalew iaAel-dot all 4l!M palelaosse asoyl aje asn;o slluarl •swaisAs;.00i paaedaad payaelle Alleo!ue4oaw aapun asn ao;algemolle sl snld fll 4311SA10d ao d Pll)IaIlsAlod `xeW n-L Ala!;sAlOd 'X-f11N MallsAlod `snld S1W j:gsAlod 'd VS xal)Alod 'oad al!i pien9eapAH Aq pannallo; snld S1VH V!lsAlOd :SW;DIs 51uaw eljapun ld-!1InVM V17'9 •ula.Iaq T•9•s uollaas 0l Aa;aa'suollea!#dde al!1 IDS-aAISaype ao j -T algel'(ZT-b0)ZEOZ I!adV llil/VSdj ue4l ssol lou aq lle4s Sulualse; laa4s aseg '(s);aays dol Oupa4pe-;Ids pue laa4S asee;o Sullslsuw 'uaa;sAs Ald-Z aano SU!400a al!l paualse;AllealueyoauU JOj 'sluawaiinbai palsllgnd ssejW%j0d pUe(ZT-to)ZIOZ I!jdV 1211/VS2I4 ul llao}las aueagwaA paaaypV-;IaS.Io;sluau,ailnbai all y1{M aauelldwoa ul pallelsu)aq I1e45 X-OyV 4.9!.ls !ad pun aX-81�JgS !od oJd lnnCI pavn9n.rp H sapnlaxa sualle3!} V al1 Ft,-9 •sluawaa[nbai pagsllgnd ssel2AlOd pue pallelsu!aq 0l Oulaanoa}ooa paiedwd;o aft all aa;T•T-COST algel :)8d ul luau3Aeliapun (d fli jallsAlod ldaaxa)OLfiT❑ WlSV ao;s;uawaalnbaa pal;[pod ay1 y11nA aauelldwoa uI pallelsu)aq IIeyS :suo!1e3!I Vi;l!1-uON Z-V-9 oad alai piengeipAH pue oad leno pjen9ejpAH}o weag delana;o MMA yy�.q/'li'�5d -.ATE •., rA• ti'•H'`'•.'!- .- c,i y'M r� -{doge}ayl delaaao Il!nA)days a41j uaal;ed anl2 egl;o pue all 0; laals do;aql}o a2pa all wile 'o.Id .''y .. 91L paen9eapAH pue oad lenCI paen9eipAH jaj ualsaype pue 13elu0a IIn}aansua of s;uauaaambai sselgAlod llsnn aauepioaae ul a qj!m pallai Alwaij ag lsnu(sdel @&Alas)sweas del-leas IItl :le.aua9 T-V-9 .snld fll PEON a0 d m jalls►ll0d'xeW n.L)IaI15AIOd'x-f1W)I3145Alod'snld S1W 1311sd10d'aXIII 1a14sAi0d"SA d VS xalJAlad 'd VS xaLAOd'(11i)laayS dp0 ddV-VS ap!H-alntM 'hays de0 ddV-VS ap!H-alnlN 'oad all..plen9eapAH 'oad lend paen9e1pAH V'9 • �� OVY3N (NNEMOjetc. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or ElastoflexS6 G FR shall be fully asphalt-applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,offset minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 5.6 Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04- 12)beneath mechanically fastened or adhered tile roof systems(Refer to Table 2 for base sheet options). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened tile roof systems(Refer to Table 2 for base sheet options). 6.6.2 PolyflexG or Polyflex G FR shall be fully torch-applied to the substrates noted In Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feetfrom course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/S-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter-battens,as required bythe tile manufacturer and FRSA/TRl April 2012(04-12)must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail-boards, to prevent the sliding and/or damage to the underlayment during the loading process. 7. BUILDING PERMIT REQUIREMENTS: As required bythe Building Official or Authority Having Jurisdiction in orderto properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. Refer to Section 4 herein for product&production locations having met codified physical properties specifications. 9. QUAUTYAssURANCE ENTITY: UL,LLC—QUA9625;(314)575-3406;k.chancellor@us.ul.com -END or EVALUATION REPORT- NEMO ETC,LLC. Evaluation Report P12060.02.09-R25 Certificate of Authorization#32455 6"EDITION(2017)FK NON-HVHZEVALUATION FL5259-RZ9 Polyglass Roof Underlayments;(954)233-1230 Revision 25.10/14/2019 Amine 7 G of 19