HomeMy WebLinkAboutCompaction TestUES Project No: Workorder No: Report Date: 3310.2000233.0000 218410-1 11/20/2020 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:ANGLERS CONTRACTING, INC.UES Technician:Mark Rogers 1351 Carlton Court Fort Pierce, FL 34949 Date Tested:11/17/2020 Project:Anglers Contracting, Inc. Various Locations, , County, FL 34949 Type of Test: Area Tested:122 Queen Catherina, Ft Pierce small addition Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Footing The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northside Footings 0-1 ft 108.0 10.0 104.5 9.8 97 Pass 2 Southside Footings 0-1 ft 108.0 10.0 105.6 10.3 98 Pass Reviewed By GFA International, Inc Certificate of Authorization No. 4930 John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1