HomeMy WebLinkAboutCompaction TestUES Project No:
Workorder No:
Report Date:
3310.2000233.0000
218410-1
11/20/2020
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:ANGLERS CONTRACTING, INC.UES Technician:Mark Rogers
1351 Carlton Court
Fort Pierce, FL 34949
Date Tested:11/17/2020
Project:Anglers Contracting, Inc.
Various Locations, , County, FL 34949
Type of Test:
Area Tested:122 Queen Catherina, Ft Pierce small
addition
Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Footing
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Northside Footings 0-1 ft 108.0 10.0 104.5 9.8 97 Pass
2 Southside Footings 0-1 ft 108.0 10.0 105.6 10.3 98 Pass
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1