Loading...
HomeMy WebLinkAboutPSU 30 Peel and StickFlorida Building Code Online 2/13/2020 r BCIS Home Log In ( User Registation Hot Topics Submit Surcharge Stats & Facts Publications i Contact Us i BCIS Ste Map Links Search bpr a Product Approval USER! Public User Prcci Approval Menu > Product or Appr2ation Search > Application List > Application Detail FL # FL11602-R10 Application Type Revision Code Version 2017 Application Status Approved Comments Archived - Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740)321-634S Greg. Keeler@owenscorning.com Authorized Signature Keeler Greg Greg. Keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) '" Validation Checklist - Hardcopy Received FL11602 R10 COI 2019 01 COI NIEMINEN.pdf Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4798 2011 FRSA/TRI April 2012 2012 TAB 117(B) 1995 UL1897 2012 Equivalence of Product Standards Certified By httos://floridabuildinq.orq/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeHY57UCe5KMr%2fsMfWgra38u9whFr5gP6KA%3d%3d 1/2 2/13/2020 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # 11602.1 Method 1 Option D 10/17/2019 10/17/2019 10/20/2019 12/10/2019 Model, Number or Name Titanium Roof Underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-45 Other: 1.) The design pressure noted herein pertains to use of a specific underlayment system beneath foam -on the sytsems. Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5 and 6 for other Limits of Use. Description Synthetic sheet -type roof underlayments Installation Instructions FL11602 R10 II 2019 10 FINAL ER FL11602-R10.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL11602 R10 AE 2019 10 FINAL ER F1_11602-R10.pdf Created by Independent Third Party: Yes iiac:k "i,'axf Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: rivacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487,1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card sate Emm httos//floridabuildino.ora/or/pr app dtl.aspx7param=wGEVXQwtDgsQPc5K%2ffrZeHYB7UCe5KMr%2fsMfWgra38ugwhFr5gP6KA%3d%3d 2/2 51251209 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved 6ummary of Products Method I Option D 08/16/2018 10/08/2018 08/23/2018 10/18/2018 # Piodei, Number or Name DescriptionTitanium [FL Roof Underlayments synthetic sheet -type roof Underlayments Use Installation Instructions mits of pproved for use in HVHZ: No FI tt 602 R7 II 2018 09 FINAL2pproved for use outside HVHZ: Yes CORNING FI t 1 107-R tpdf Verified By: Robert Merriman PE-59166 Impact Resistant: N/A Design Pressure: +N/A/-45 Created by Independent Third Party: Yes other: 1.) The design pressure noted herein pertains to use of Evacuation Reports a specific underleyment system beneath foam -on the sytsems. I F 1602 R7 AE 2018 09 FINAL2 ER OWEN5 ions 5 Refer to 2. Refer to ER Sections CORNING F_11602 97 rZdf yER _ i. and 6 for other Limit of Use. Created by Independent Third Party Yes Created o tact :; a§,Qs BI ' S Road, II h == FL 32399 phone• 850-48>-1924 The State of Florida Is an AA(EE0 employer. Copyright 200J-2013 State F on a.:: Privacy Statement:: Accessibtl'ty atemen :: R fund StatemenC Under Fiorida law, email addresses are public reverse. If you do hot want your a -mall address released In response to a publicrecords request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please capon 850.487.1395. 'Pursuant to Section 455.Y75(1), Florida Statutes, affective October 1, 2012, licensees licensed under Chapter 455, FS, must provide the Department with an email address If they have one. The unrolls provided may be used for offltlal communication with the licensee. However small addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available Co the public. To determine if you are a licensee under Chapter 455, FS„ please click .ere . Product Apprwai Accepts, https:llwuw,floridabuiiding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeHY87UCe5KMr5EmR4gtpLet7gKP15TBaea%3d%3d 212 Yi1 ENGINEER EVALUATE TEST Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740)321-6345 Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT06478 (203)262-9245 CONSULT CERTIFY Evaluation Report 111980,11.08-R8 FL11602-R7 Date of Issuance:1110312008 Revision 8: 09/14/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the Go' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titanium'e" Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report bythe named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOI etc, requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: ,oj "i?`ir f:, ' s cas ,a.n Robert l.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 Nieminen, P.E, on 09/14/2018. This does not serve as an elettronicaily signed document. CERTIFICATION OF INDEPENDENCE: 1. bil ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the product. 5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E.are, In anyway, the Designerof Record forany project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose, ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment compliance Statement: Titanium'"' Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 1507,1.1, R905.1.1 Exception Unrolling, Breaking Strength, PliaNiity ASI M UZZb Zuoo 15071.1, R905AA Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 203S 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull -through resistance TAS 117(B) 1995 ERD (TST6049) Physical Properties 115010.04,09 04/29/2609 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520.06.11 06/15/2011 ERD(TST6049) ASTM D226 138010,08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520108,11-1 08/12/2011 ITS(TST1509) ASTM 0226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-OD2A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101923107COQ-011 01/23/2015 Owens Corning Product equivalency Declaration 06/18/2018 FRI(TST5878) - ASTM D1970 QCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI UST5878) ASTM D1970; Tear strength OCF-332.02-02 10/03/2017 PRI (TST5878) ASTM 01970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-343-02-01 11/09/2017 PRI (TST5878) ASTM D4798 OCF-341-02-01 11/27/2017 PRI (TST5878) TAS 117(B); Pull -through OCF-422.02-02 04/03/2018 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-425-02-01 08/13/2018 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 4.1 Self -Adhering Underlayments: 4.1.1 Titanium'M PSU-30 Is an unreinforced polymer modified bitumen material adhered to the underside of a polymer - coated, synthetic woven sheet. The underside is backed with a release film. Unitweight 24lbs/square. Meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, LLC Evaluation Report 111980.11.08-R8 CertiJkote of Authorization #32435 e" EDITION (2017) FaC NON-NVHZ EVALUATION F1.11602-117 Titanium Roof Underlayments Revision 8: 09/14/2018 Page 2 of 7 ONEMOletc. 4.2 _Mechanicaliy Fastened Underlayments: 4.2.1 Titanium"" UDL-25 is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5 lbs./square; meets FBC 1507.1.1 & R905.1.1 (Exception). 4.2.2 Titanium'"' UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 lbs./square; meets FBC 1507,1.1 & R905.1.1(Exception), 4.2.3 Titanium"" UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7 lbs./square; meets FBC 1507.1.1 & R905.1.1(Exception). 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification Is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium'm Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made tothe Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: a® a ♦ e SHINCtLES..•NAILAYJ TILE: FQAM•;'ON TILE MEtf11 - "&3HIIJ�CES Si.ATf .... itanium PSU-30 Yes Yes Yes Yes (Dub Yes Yes (See 5.5.1) a -30 Yes Yes No Yes Yes Yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Titanium UDL-30 Yes taesesh.al--.ply (Base sheet In 2.pil Yes Yes Yes systeml sate') Titanium UDL-SO Yes No j No Yes _. Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. �p•.14 �p q- ,g �y�#�d}I. s t.�aY jak,�t�4e1'i f4i�fi'"`s+�*'+a`u�'4"Rg��f�'E2�v:S.y�f��"f�"x�'Fie��-��wt��}¢'f.¢'fti�.�T4.x??P'�i�'F7•I�r�Ge'Y f� Rh�n +:� Nk �# "i Il� n�� d °i ��Gfp }Y?�''4. },tt �5( +y qJ ib' J"�Y,i E 4. �i'����"�i'�.,'rem�.a�,'k i Dow i� Titanik nPS -30 ,I AE '' . t Refer to Tile Manufacturer's orAdheslve Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 111980.11.08-R8 Certificate ofAuthorimtion 832.455 0 EDITION (2017) Pee NON•HVHZ EVALUATION F1.11602-117 Titanium Roof Underlayments Revision 8: 09/14/2018 Page 3 of 7 ONEMOletc. 5.6 Allowable Substrates; Titanium PSU-30: 5.6.1 Direct -Bond d to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond. 5.6.2 Bond to Mechanically Attached Base Sheet; ➢ ASTM D226, Type I or II felt, ➢ Titanium UDL-30 (primed with D41 primer) of UDL-30 (inverted). 5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04.12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies, Titanium PSU-30 (Dubai, UAE), self -adhered and back -nailed max. 12" D.C. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #2 Maximum Design Pressure =-30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted). Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-Inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-Inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max. 12" D.C. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #3 Maximum Design Pressure =_-30 psf* Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga, annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch D.E. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max. 12" D.C. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. NOMO ETC, LLC Evaluation Report 111980.11,08.RB Certificate of Authorizotion#32455 6' EDITION(2017) FaC NON-HVHZ EVALUATION FL11602-117 Titanium Roof Underlayments Revision 8: 09/141ZOlB Page 4 of 7 ONEMOletc. #4 Maximum Design Pressure=-45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min, 32 ga., 1-5/8" diameter tin caps Spacing: 6-Inch o.c. at 4-Inch wide side laps and 8-Inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" o.c, in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #5 Maximum Design Pressure=-45 psf*: Deck: Min, 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-Inch with min. 32 ga., 1.5/8" diameter tin caps. Spacing: 6-inch o.c, at 4-inch wide side laps and 8-Inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" o,c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design .pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth In Section 2.2.10A of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5,7 Exposure Limitations: _ Titanium UDL-25, Titanium UDI. 30 or Titanium UDL-50 shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 180-days. 5.8 Tile Slippage Limitations [per FRSA/TRI April 2012104-1217: When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. NEMO ETC, LLC Evaluation Report I11980.11.08-R8 CertfP<ate of Authorization #32455 6Te EDITION t20171 FBC NON-HVHZ EVALUATION FL11602-R7 Titanium Roof Underiayments Revision 8: 09/14/2018 Page 5 of 7 6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris priorto application, and prime the substrate (If applicable). 6.3 Titamum UDL%25 Titanium UDL-30 orTnamum Ubl 5tl °' _ 6.3.1 Shall be installed In compliance with the requirements for ASTM D226, Type I or 11 underlayment In FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. Mechanical attachment of Titanium UDL-50 is ilmitgd to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6.3.2.1 Cade Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1,1 states: `...except metal cap nails shall be required where the ultimate design wind speed, Vamo equals or exceeds 150 mph." Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the Titanium"" UDL-25, Titanium UDL-30 or Titanium UOL- 50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.3 Slopes of 4.12 or greater: End (vertical) laps shall be minimum 6-Inches and side (horizontal) laps shall be minimum 4-inches. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 tolessthan 4:12: Double layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet overthe starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum 25-Inch side (horizontal) laps, resulting in a double -layer application. 6.4 LTitaniilm't` l' 111: - - 6.4A Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. Titanium" PSU-30 shall be back -nailed max. 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 6.4.2 Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium'"' PSU-30 shall be back -nailed max. 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. NEMO ETC, LLC Evaluation Report 111980.11.08-R8 Certificate ojAuthorization N32455 6'"EDITION (2017)FeC NON-HVHZ EVALUATION FL11602-RI Titanium Roof Underiayments Revision 8: 09/14/2018 Page 6 of 7 ONEMOjetc. 6.5 1 The Titanium 2-Ply System consists of a base layer of TitaniumUDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed byTitanium PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. 6.5.3 Tile Applications; For nail -on the installations, install Titanium UDL-30 (top surface primed or sheet Inverted) in accordance with FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. For adhesive -set tile roofing, refer to section 5.6.3 herein. Tile shall be loaded and staged Ina manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation this product. Contact the noted CIA agency for information on product locations covered for P.A.C. 616ZO.3 CIA requirements. The following pants have qualified products under their respective physical properties specifications. Plant -- Spe$€ficati Products`" -� Mission, BC, Canada FBC 1507.1.1(Exception) Titanium UOL30; Titanium UDL-50 Qingdao, China FBC 1507.11 (Exception) Titanium UDL-25; Titanium UDL-30; Titanium UDL-50 Dubai, UAE FRSA/TRI 04-12 (2-plysystem) Titanium PSU-30 (Dubai, UAE) Brentwood, NH ASTM D1970, FRSA/TRI 04-12 Titanium PSU-30 (Brentwood, NH) Testing Services NA Inc. — QUA1673; (604) - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980.11.08,98 Certificate of Aafhorization#32455 6'a EDITION (2017) FBC NON-HVHZ EVALUATION F1.11602-117 Titanium Roof Underlaymerns Revision 8: 09/14/2018 Page 7 of 7