HomeMy WebLinkAboutPSU 30 Peel and StickFlorida Building Code Online
2/13/2020
r
BCIS Home Log In ( User Registation Hot Topics Submit Surcharge Stats & Facts Publications i Contact Us i BCIS Ste Map Links Search
bpr
a
Product Approval
USER! Public User
Prcci Approval Menu > Product or Appr2ation Search > Application List > Application Detail
FL #
FL11602-R10
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
-
Product Manufacturer Owens Corning Roofing and Asphalt, LLC
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43645
(740)321-634S
Greg. Keeler@owenscorning.com
Authorized Signature Keeler Greg
Greg. Keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740) 321-6345
greg.keeler@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
.. Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John W. Knezevich, PE
Certificate of Independence
Referenced Standard and Year (of Standard)
'" Validation Checklist - Hardcopy Received
FL11602 R10 COI 2019 01 COI NIEMINEN.pdf
Standard
Year
ASTM D1970
2015
ASTM D226 (physicals)
2009
ASTM D4798
2011
FRSA/TRI April 2012
2012
TAB 117(B)
1995
UL1897
2012
Equivalence of Product Standards
Certified By
httos://floridabuildinq.orq/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeHY57UCe5KMr%2fsMfWgra38u9whFr5gP6KA%3d%3d 1/2
2/13/2020
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
11602.1
Method 1 Option D
10/17/2019
10/17/2019
10/20/2019
12/10/2019
Model, Number or Name
Titanium Roof Underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-45
Other: 1.) The design pressure noted herein pertains to use of
a specific underlayment system beneath foam -on the sytsems.
Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5
and 6 for other Limits of Use.
Description
Synthetic sheet -type roof underlayments
Installation Instructions
FL11602 R10 II 2019 10 FINAL ER FL11602-R10.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL11602 R10 AE 2019 10 FINAL ER F1_11602-R10.pdf
Created by Independent Third Party: Yes
iiac:k "i,'axf
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: rivacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487,1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
sate
Emm
httos//floridabuildino.ora/or/pr app dtl.aspx7param=wGEVXQwtDgsQPc5K%2ffrZeHYB7UCe5KMr%2fsMfWgra38ugwhFr5gP6KA%3d%3d 2/2
51251209
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
6ummary of Products
Method I Option D
08/16/2018
10/08/2018
08/23/2018
10/18/2018
#
Piodei, Number or Name
DescriptionTitanium
[FL
Roof Underlayments
synthetic sheet -type roof Underlayments
Use
Installation Instructions
mits of
pproved for use in HVHZ: No
FI tt 602 R7 II 2018 09 FINAL2pproved
for use outside HVHZ: Yes
CORNING FI t 1 107-R tpdf
Verified By: Robert Merriman PE-59166
Impact Resistant: N/A
Design Pressure: +N/A/-45
Created by Independent Third Party: Yes
other: 1.) The design pressure noted herein pertains to use of
Evacuation Reports
a specific underleyment system beneath foam -on the sytsems.
I F 1602 R7 AE 2018 09 FINAL2 ER OWEN5
ions 5
Refer to 2. Refer to ER Sections
CORNING F_11602 97 rZdf
yER _
i. and 6 for other Limit of Use.
Created by Independent Third Party Yes
Created
o tact :; a§,Qs BI ' S Road, II h == FL 32399 phone• 850-48>-1924
The State of Florida Is an AA(EE0 employer. Copyright 200J-2013 State F on a.:: Privacy Statement:: Accessibtl'ty atemen :: R fund StatemenC
Under Fiorida law, email addresses are public reverse. If you do hot want your a -mall address released In response to a publicrecords request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please capon 850.487.1395. 'Pursuant to Section 455.Y75(1),
Florida Statutes, affective October 1, 2012, licensees licensed under Chapter 455, FS, must provide the Department with an email address If they have one. The unrolls
provided may be used for offltlal communication with the licensee. However small addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available Co the public. To determine if you are a licensee under Chapter 455, FS„ please click .ere .
Product Apprwai Accepts,
https:llwuw,floridabuiiding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeHY87UCe5KMr5EmR4gtpLet7gKP15TBaea%3d%3d 212
Yi1
ENGINEER EVALUATE TEST
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
(740)321-6345
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT06478
(203)262-9245
CONSULT CERTIFY
Evaluation Report 111980,11.08-R8
FL11602-R7
Date of Issuance:1110312008
Revision 8: 09/14/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the Go' Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Titanium'e" Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report bythe named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOI etc, requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
,oj "i?`ir f:,
'
s cas
,a.n
Robert l.M.Nieminen,P.E.
The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983
Nieminen, P.E, on 09/14/2018. This does not serve as an
elettronicaily signed document.
CERTIFICATION OF INDEPENDENCE:
1. bil ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E.are, In anyway, the Designerof Record forany project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose,
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
compliance Statement: Titanium'"' Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC,
have demonstrated compliance with the intent of the following sections of the 61h Edition (2017) Florida Building
Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
1507,1.1, R905.1.1 Exception Unrolling, Breaking Strength, PliaNiity ASI M UZZb Zuoo
15071.1, R905AA Exception Tear Strength ASTM D1970 2015
1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 203S
1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012
TAS 110 Accelerated Weathering ASTM D4798 2011
TAS 110 Pull -through resistance TAS 117(B) 1995
ERD (TST6049)
Physical Properties
115010.04,09
04/29/2609
ERD (TST6049)
Physical Properties
115010.05.10
05/14/2010
ERD (TST6049)
Physical Properties
135520.06.11
06/15/2011
ERD(TST6049)
ASTM D226
138010,08.11
08/11/2011
ERD (TST6049)
Wind Uplift
135520108,11-1
08/12/2011
ITS(TST1509)
ASTM 0226
311801000Q-003
04/26/2007
ITS(TST1509)
ASTM D226
3130639COQ-OD2A
08/21/2007
ITS(TST1509)
Physical Properties
3126617COQ-005
10/31/2007
ITS(TST1509)
ASTM D226
101923107COQ-011
01/23/2015
Owens Corning
Product equivalency
Declaration
06/18/2018
FRI(TST5878)
- ASTM D1970
QCF-341-02-01
09/20/2017
PRI (TST5878)
ASTM D1970; Tear strength
OCF-331-02-02
10/03/2017
PRI UST5878)
ASTM D1970; Tear strength
OCF-332.02-02
10/03/2017
PRI (TST5878)
ASTM 01970; Tear strength
OCF-334-02-02
10/03/2017
PRI (TST5878)
FRSA/TRI April 2012 (04-12), partial
OCF-343-02-01
11/09/2017
PRI (TST5878)
ASTM D4798
OCF-341-02-01
11/27/2017
PRI (TST5878)
TAS 117(B); Pull -through
OCF-422.02-02
04/03/2018
PRI (TST5878)
FRSA/TRI April 2012 (04-12), partial
OCF-425-02-01
08/13/2018
ITS (QUA1673)
Quality Control
ITS Listings
Current
ITS (QUA1673)
Quality Control
Service Confirmation
09/30/2017
4.1 Self -Adhering Underlayments:
4.1.1 Titanium'M PSU-30 Is an unreinforced polymer modified bitumen material adhered to the underside of a polymer -
coated, synthetic woven sheet. The underside is backed with a release film. Unitweight 24lbs/square. Meets ASTM
D1970 and FRSA/TRI April 2012.
NEMO ETC, LLC Evaluation Report 111980.11.08-R8
CertiJkote of Authorization #32435 e" EDITION (2017) FaC NON-NVHZ EVALUATION F1.11602-117
Titanium Roof Underlayments Revision 8: 09/14/2018
Page 2 of 7
ONEMOletc.
4.2 _Mechanicaliy Fastened Underlayments:
4.2.1 Titanium"" UDL-25 is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a
polymer coating. Unit weight 2.5 lbs./square; meets FBC 1507.1.1 & R905.1.1 (Exception).
4.2.2 Titanium'"' UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a
polymer coating. Unit weight 4.0 lbs./square; meets FBC 1507,1.1 & R905.1.1(Exception),
4.2.3 Titanium"" UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a
polymer coating. Unit weight 4.7 lbs./square; meets FBC 1507.1.1 & R905.1.1(Exception).
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification Is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Titanium'm Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made tothe Authority Having Jurisdiction
for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
a® a ♦ e
SHINCtLES..•NAILAYJ TILE: FQAM•;'ON TILE MEtf11 - "&3HIIJ�CES Si.ATf
....
itanium PSU-30 Yes Yes Yes Yes
(Dub Yes Yes (See 5.5.1)
a -30 Yes Yes No Yes Yes Yes
Titanium UDL-25 Yes No No Yes Yes Yes
Yes Yes
Titanium UDL-30 Yes taesesh.al--.ply (Base sheet In 2.pil Yes Yes Yes
systeml sate')
Titanium UDL-SO Yes No j No Yes _. Yes Yes
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
�p•.14 �p q- ,g �y�#�d}I.
s t.�aY jak,�t�4e1'i f4i�fi'"`s+�*'+a`u�'4"Rg��f�'E2�v:S.y�f��"f�"x�'Fie��-��wt��}¢'f.¢'fti�.�T4.x??P'�i�'F7•I�r�Ge'Y
f� Rh�n +:� Nk �# "i
Il� n��
d °i
��Gfp }Y?�''4. },tt �5( +y qJ ib' J"�Y,i E 4.
�i'����"�i'�.,'rem�.a�,'k
i Dow i�
Titanik nPS -30 ,I AE
''
.
t Refer to Tile Manufacturer's orAdheslve Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 111980.11.08-R8
Certificate ofAuthorimtion 832.455 0 EDITION (2017) Pee NON•HVHZ EVALUATION F1.11602-117
Titanium Roof Underlayments Revision 8: 09/14/2018
Page 3 of 7
ONEMOletc.
5.6 Allowable Substrates; Titanium PSU-30:
5.6.1 Direct -Bond d to Deck:
➢ New untreated plywood;
➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond.
5.6.2 Bond to Mechanically Attached Base Sheet;
➢ ASTM D226, Type I or II felt,
➢ Titanium UDL-30 (primed with D41 primer) of UDL-30 (inverted).
5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April
2012 (04.12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: One or two plies, Titanium PSU-30 (Dubai, UAE), self -adhered and back -nailed max. 12" D.C. in
accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements.
#2 Maximum Design Pressure =-30 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted).
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-Inch
with min. 32 ga., 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at 4-Inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max. 12" D.C. in
accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements.
#3 Maximum Design Pressure =_-30 psf*
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up)
Fasteners: 12 ga, annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps.
Spacing: 6-inch D.E. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max. 12" D.C. in
accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements.
NOMO ETC, LLC Evaluation Report 111980.11,08.RB
Certificate of Authorizotion#32455 6' EDITION(2017) FaC NON-HVHZ EVALUATION FL11602-117
Titanium Roof Underlayments Revision 8: 09/141ZOlB
Page 4 of 7
ONEMOletc.
#4 Maximum Design Pressure=-45 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min, 32 ga., 1-5/8" diameter tin caps
Spacing: 6-Inch o.c. at 4-Inch wide side laps and 8-Inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" o.c, in
accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements.
#5 Maximum Design Pressure=-45 psf*:
Deck: Min, 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-Inch
with min. 32 ga., 1.5/8" diameter tin caps.
Spacing: 6-inch o.c, at 4-inch wide side laps and 8-Inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" o,c. in
accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements.
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design .pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
marked with an asterisk* carry the limitations set forth In Section 2.2.10A of FM Loss Prevention Data Sheet 1-29
(January 2016) for Zone 2/3 enhancements.
5,7 Exposure Limitations: _
Titanium UDL-25, Titanium UDI. 30 or Titanium UDL-50 shall not be left exposed for longer than 30-days.
Titanium PSU-30 shall not be left exposed for longer than 180-days.
5.8 Tile Slippage Limitations [per FRSA/TRI April 2012104-1217:
When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
NEMO ETC, LLC Evaluation Report I11980.11.08-R8
CertfP<ate of Authorization #32455 6Te EDITION t20171 FBC NON-HVHZ EVALUATION FL11602-R7
Titanium Roof Underiayments Revision 8: 09/14/2018
Page 5 of 7
6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris priorto application, and prime the substrate (If applicable).
6.3 Titamum UDL%25 Titanium UDL-30 orTnamum Ubl 5tl °' _
6.3.1 Shall be installed In compliance with the requirements for ASTM D226, Type I or 11 underlayment In FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width.
6.3.2 Fasteners:
Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with
minimum 1-inch diameter plastic caps.
Mechanical attachment of Titanium UDL-50 is ilmitgd to ring shank roofing nails with minimum 3/8-inch diameter
heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples.
6.3.2.1 Cade Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1,1 states: `...except metal cap nails shall
be required where the ultimate design wind speed, Vamo equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the Titanium"" UDL-25, Titanium UDL-30 or Titanium UOL-
50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1
or R905.1.1.
6.3.3 Slopes of 4.12 or greater:
End (vertical) laps shall be minimum 6-Inches and side (horizontal) laps shall be minimum 4-inches.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to
be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of
the battens.
6.3.4 Slopes of 2:12 tolessthan 4:12:
Double layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet overthe
starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum 25-Inch
side (horizontal) laps, resulting in a double -layer application.
6.4 LTitaniilm't` l' 111: - -
6.4A Non -Tile Installations:
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements.
Titanium" PSU-30 shall be back -nailed max. 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC
published installation requirements.
6.4.2 Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium'"' PSU-30 shall be back -nailed
max. 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements.
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Refer
to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging.
NEMO ETC, LLC Evaluation Report 111980.11.08-R8
Certificate ojAuthorization N32455 6'"EDITION (2017)FeC NON-HVHZ EVALUATION FL11602-RI
Titanium Roof Underiayments Revision 8: 09/14/2018
Page 6 of 7
ONEMOjetc.
6.5 1 The Titanium 2-Ply System consists of a base layer of TitaniumUDL-30 (top -surface primed or sheet inverted)
mechanically attached to the wood roof deck followed byTitanium PSU-30, self -adhered.
6.5.2 Non -Tile Applications:
Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium
PSU-30 in accordance with Section 6.4.
6.5.3 Tile Applications;
For nail -on the installations, install Titanium UDL-30 (top surface primed or sheet Inverted) in accordance with
FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM
D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4.
For adhesive -set tile roofing, refer to section 5.6.3 herein.
Tile shall be loaded and staged Ina manner that prevents tile slippage and/or damage to the underlayment. Refer
to Table 2 herein, and Owens Corning Roofing and Asphalt, LLC published requirements for tile staging.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
this product.
Contact the noted CIA agency for information on product locations covered for P.A.C. 616ZO.3 CIA requirements.
The following pants have qualified products under their respective physical properties specifications.
Plant --
Spe$€ficati
Products`" -�
Mission, BC, Canada
FBC 1507.1.1(Exception)
Titanium UOL30; Titanium UDL-50
Qingdao, China
FBC 1507.11 (Exception)
Titanium UDL-25; Titanium UDL-30; Titanium UDL-50
Dubai, UAE
FRSA/TRI 04-12 (2-plysystem)
Titanium PSU-30 (Dubai, UAE)
Brentwood, NH
ASTM D1970, FRSA/TRI 04-12
Titanium PSU-30 (Brentwood, NH)
Testing Services NA Inc. — QUA1673; (604)
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 111980.11.08,98
Certificate of Aafhorization#32455 6'a EDITION (2017) FBC NON-HVHZ EVALUATION F1.11602-117
Titanium Roof Underlaymerns Revision 8: 09/14/2018
Page 7 of 7