HomeMy WebLinkAboutDM CLASS 500 - 27499.174/10/2020
Florida Building Code Online
FL #
FL27499-RI
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
Dynamic Metals
Address/Phone/Email
3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
.,1J Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License
PE-62354
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
12/31/2026
Validated By
Lucas A. Turner, P.E., MBA
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Validation Checklist - Hardcopy Received
FL27499 R1 COI Dyn COI.pdf
Standard
Year
TAS 100
1995
TAS 110
2003
TAS 125
2003
https://www.floridabuilding.org/pr/pr_app_dtl,aspx?param=wGEVXQvADquHOE2Ywe%2bOsCepABg3"/o2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ°/ 3d%... 1/4
4/10/2020
Florida Building Code Online
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.16 1 DM Class 2000 2" Mechanical Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva[ report for Limits of Use.
27499.177"" 1 DM Class 500 5V Crimp
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.18 1 DM Class 500 5V Crimp
Installation Instructions
FL27499 Rl II 2MSA18HZ pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Eva115 pdf
Created by Independent Third Party: Yes
24 Ga. galvalume coated steel roof panel, 18" wide, with 2"
standing seams.
Installation Instructions
FL27499 Rl II 2MSS18HZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 Rl AE DM Eval16.pdf
Created by Independent Third Party: Yes
26 Ga. galvalume coated steel roof panel, 24" wide, with 5V
crimp.
Installation Instructions
FL27499 RI II SVS.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 Rl AE DM Eva117.pdf
Created by Independent Third Party: Yes
.032" Aluminum roof panel, 24" wide, with 5V Crimp
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 Rl II 5VAL.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use FL27499 RI AE OM Eval18 pdf
Created by Independent Third Party: Yes
uaeh ne>o
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-457-1824
The State of Florida Is an AA/EEO employer. Qladight 200J-2013 State of Florida.:: Privacy statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455,275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
Provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, ES., please click here .
Product Approval Accepts:
Wtark
https:llwww.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquHOE2Ywee/ 2bOsCepABg3%2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ%3d%... 4/4
ENGINEERING, DRAFTING, CONSULTING
15211 97th Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24" WIDE
ROOF PANEL (FLPA# 27499.17)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 500 Series 26 Ga, Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02.01.
Technical Documentation:
1. Drawing "5VS-HZ" dated 8/15/19, signed and sealed by Scott Wolters, PE,
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE,
3. Supplemental Calculations to support "5VS-HZ" drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 24" (nominal)
Fastener Spacing across panel: 12" (at Overlaps & Center Rib)
Min. Slope: HVHZ: 2'712"
Non-HVHZ: '/'712" (with Lap Sealant)
3'712" (no Lap Sealant)
5PFCIA-10NG IN MFACT O�515TANTCWTAINWALL5, 5T0p5V P.ONi"5, & WINPOIA15
Field
Installation
Perimeter & Corner
Installation
Max. Design Pressure:
-117.75 psf
-206 psf
Fastener Spacing:
4" From Ends, 16" Max. O.C.
4" From Ends, 8" Max. O.C.
Min Panel Fasteners:
#10x1 %2' HiLo HWH Screw
with Weather -seal Washer
#10x1 '/" HiLo HWH Screw
with Weather -seal Washer
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga, x 1 ''/d' galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: /2 (15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with Bd ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499,17, DM Class 500".
5FFCIAI-IZING iN MpFlCt &E5151"M r CUPfAINWAI,LS_ 5f0ffFFOW5, & WINPOWS
Panel fgrmLng_., These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 31d party CA provider, to the dimensions shown on Drawing 5VS-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSO-4560615 SSQ-8681 118
5VC-0490718 5VC-0360516 5VC-0521218
Re -Roofing: The DIVI Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the
Florida Building Code.
If you have any questions or need more information concerning this approval please contact me.
Thank you,
0' OtT - (j4
E.
Att WO*ters
No 62,354
FL PE# 62354
Z
AHIG16 2019
% STATE OF z
4u
IN IN,,PjCf B 1hWCA/5
zm-gzz 099, 1'- lwu 9.114115z,3 M}S) 1w
xuxsr li M30 wiry 1sv wl, -6-,q ftqs):Yvj WEE 141 Ovaq NIV4,Lsjm
OVE
swa
S�anYs I SIVANDIMNAG
I
UILj
0.1
LU
clq
LL.
CL
0
0
uj
>
un�
>
J