HomeMy WebLinkAboutwindows changed approvalSILVER LINE WINDOWS AND DOORS V1 SERIES/ 50 SERIES SINGLE -HUNG WINDOWS (2000) GFNIFRAI NIC)TFC- 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC) AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • AAMA/WDMA/CSA 101/I.S.2/A440-08/11 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS. S. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. GLASS SHALL MEET THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 1 FOR GLAZING DETAILS. DESIGN PRESSURE TABLE PRODUCT MODEL WINDOW SIZE CONFIGURATION PG RATING GLASS TYPE MISSILE IMPACT RATING 2001 36.0"X 62.0" O/X +35/-35 PSF SS/SS NON IMPACT 2001 48.0" X 80.0" O/X +15/-15 PSF SS/SS NON IMPACT 2001 36.0" X 62.0" O/X +50/-50 PSF DS/DS NON IMPACT 2001 45.0" X 62.0" O/X +40/-40 PSF DS/DS NON IMPACT 2001 48.0" X 73.0" O/X +30/-30 PSF DS/DS NON IMPACT 2002 72.0" X 62.0" O/X-O/X +35/-35 PSF SS/SS NON IMPACT 2002 96.0" X 62.0" O/X-O/X +20/-20 PSF SS/SS NON IMPACT 2002 72.0" X 80.0" O/X-O/X +20/-20 PSF SS/SS NON IMPACT 2002 96.0" X 80.0" O/X-O/X +15/-15 PSF SS/SS NON IMPACT 2003 108.0" X 80.0" O/X-O/X-O/X +25/-25 PSF SS/SS NON IMPACT 2003 108.0" X 62.0" O/X-O/X-O/X +35/-35 PSF SS/SS NON IMPACT TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 GENERAL NOTES & GLAZING DETAILS 2 ELEVATIONS & ANCHOR LAYOUTS 3 VERTICAL SECTIONS 4 HORIZONTAL SECTIONS 5 ANCHOR DETAIL & SCHEDULE 1/2" MIN. GLASS BITE 5/8" O.A. INSULATED GLASS EXTERIOR INTERIOR GLAZING DETAIL GLAZING NOTE: • GLASS THICKNESS AND TYPE SHALL COMPLY WITH ASTM E-1300 GLASS CHARTS REQUIREMENT Silver Line brAn&fi 4efi ONE SILVERLINE DRIVE NORTH BRUNSWICK, NJ 08902 PH (800) 234-4228 J zm E LiI w vi o in O Iv Q wwN�a (7 a m rn O1 3 �! ((D Z zZaLL 3 c 06 � w o m � C) w 3 o z o } ca " z CO LLa J C, Lu ii�w Lu Z cr Q <C J (n F- w (D w REMARKS BY I DATE 6TH FBC EDITION I FM 10/17 AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. SyNorero, P. Dat :420018 tG1 ••.31: Q ' � �� _.•••• I ;1 :••N .7 7 OF ; tYZ OT O 4UQ'� •• w�.�` HEIwwkW.E. FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FSPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 09.19.17 DWG. BY: CHK. BY: CL HFN SCALE: NTS DWG.#: SWD017 SHEET: OF 5 i UNIT MAX. HEIGHT 80.0" _ UNIT MAX. WIDTH 48.0" r% 1 (1 NAAV ELEVATION 6" FROM CORNER (TYP.) 6" FROM CORNER (TYP.) ---I I- q- -I �- 3.0" (TYP.) 3.0" (TYP.) 6.0" FROM CORNER (TYP.) ANCHOR LAYOUT THROUGH FRAME v1AX. HT UI M. HEI 8C UNIT MAX. WIDTH 108.0" D.L.O MAX. A WIDTH 31.69" 3 J IT NX. 3HT .0" A 4 B 4 X1f 11XII "XII ELEVATION —1 6" (TYP.) 6" FROM 6" (TYP.) CORNER (TYP.) 14.0" MAX. (TYP) 4� 0„ (TYP.) 4.0 (TYP.) 6.0" (TYP.) 11011 11011 I1011 "X X X ANCHOR LAYOUT THROUGH FRAME D.L.O. MAX. C HEIGHT 4 37.0" 6.0" FROM CORNER (TYP.) 6.0" (TYP.) 6.0" (TYP.) NOTE: 1) APPLIES TO TWIN UNITS OF EQUIVALENT OR LESSER PANEL DIMENSIONS. Silver Line byAnd g&, ONE SILVERLINE DRIVE NORTH BRUNSWICK, NJ 08902 PH: (800) 234-4228 Z m E O a N o Ln o mN ao���o O J LL� 0 m ' v z am==3 W Z Z Z Z a LL 3 Lu o h o m O co m w cr C '-'-' Q Lu w � a � � REMARKS BY I DATE 6TH FBC EDITION I FM 10/17 AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ```%I%IIIIIIIIIIff` �-I` E . O �.� E S 'i :�•N .7 7 OF ; tYz w�.Z. 10 HEdkkiJk!NOFIkW�1.� FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 09.19.17 DWG. BY: I CHK. BY: CL HFN SCALE: NTS DWG.#: SWD017 SHEET: I OF 5 SEE GLAZING q HORIZONTAL SECTION 4 OPERABLE JAMB g HORIZONTAL SECTION 4 MULLION C HORIZONTAL SECTION 4 FIXED JAMB Silver Line byAnd&r' &i ONE SILVERLINE DRIVE NORTH BRUNSWICK, NJ 08902 PH:(8001234-4228 z CJ z m m � Cn o 0 W o d o n o J .� N p N u W w C7 mm� 9 3 V) a Za _ ' a Z LL 3 Q t� o o m V) Z J 3 Q pz ° N } m m On LEI O 2 W cr <C uiLuQ JLn W � REMARKS BY DATE 6TH FBC EDITION FM 10/17 AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ```�I%IIIIIIIIIIff` O 1�e ,`� ••��� .... ICI L� E s • p 'i :�•N .7 7 OF OT O 1UQ'�'� HE114liElEb�•E. FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. B 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 09.19.17 DWG. BY: CHK. BY: CL HFN SCALE: NTS DWG.#: SWD017 SHEET: 11 OF 5 SUBSTRATE BY OTHE PERIMETER SEALANT BY OTHE EXTERIOR INTFRICIR q ANCHOR DETAIL �,5j THROUGH FRAME (HEAD) INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF ±1/2 INCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. 5. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 6. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 7. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. SUBSTRATE BY OTHERS --m-] �-- 3/8" MAX. SHIM SPACE INTFRI(1R TO BE INSTALLED ABOVE MEETING RAIL (FLAT HEAD SCREW) TO BE INSTALLED BELOW MEETING RAIL. MIN. UUo EDGE DISTANCE EXTERIOR MIN. EMB. -- .7 PERIMETER SEALANT BY OTHERS g ANCHOR DETAIL THROUGH FRAME (JAMB) 5) ANCHOR SCHEDULE METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN. EDGE DISTANCE WOOD: MIN. SG = 0.55 #10 WOOD SCREW 1.5" 0.75" METAL: 18 GAUGE 3 THREADS MIN Steel, MIN. Fy = 33KSI #10 TEK SCREW PENETRATION BEYOND 0.75" THROUGH FRAME METAL CONCRETE: fc=3000PS1 1/4" ITW TAPCON 1.75" 2.5" MASONRY: CMU per 1/4" ITW TAPCON 1.75" 2.5" ASTM C90 fc=2000PS1 NOTE: 1. LOCATION OF BUCK OR WINDOW ANCHORS MAY BE ADJUSTED TO MAINTAIN 1" MIN. CENTER TO CENTER SPACING BETWEEN ANCHORS SUCH THAT MAX. O.C. SPACING SPECIFIED IS NOT EXCEEDED. 2. BUCK MAY BE FLUSH WITH FACE OF THE BLOCK. 1/4" ITW TAPCON ANCHOR 4" FROM CORNERS 16" MAX. O.C. THEREAFTER 2X WOOD BUCK OF SUFFICIENT DEPTH TO FULLY SUPPORT WINDOW FRAME. BY OTHERS 1 1/4" MIN. EMBEDMENT ?° ° : °` 1 1/2" MIN. EDGE ° " DISTANCE 2" MIN. EDGE DISTANCE CONCRETE/ MASONRY BY OTHERS Silver Line byAnd&r' &ri ONE SILVERLINE DRIVE NORTH BRUNSWICK, NJ 08902 PH:(8001234-4228 z CJ z m m � LLI W J � d CS o C7o 0 a a` 00 vLn o�c"��= p a — w W Z z z Q LL 3 5 o o m V) Q w J 3 M o z } m = m LEI U Z a cr Q <C w� J d W � REMARKS BY I DATE 6TH FBC EDITION I FM 10/17 AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ```���Illlftllllff` ,`� ••�,, .... ICI �.� E S 'i :�•N .7 7 OF OT O 4UQ'�'� HE1144&6l �i FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. B 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 09.19.17 DWG. BY: CHK. BY: CL HFN SCALE: NTS DWG.#: SWD017 SHEET: BUCK INSTALLATION DETAIL OF 5