HomeMy WebLinkAboutnew energy calcsEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 711/19/2020 9:47 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
PHILIPPE RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
PALM DRIVE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
2357
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.34 186.83 ft²
SHGC=0.23
Sgl, U=0.42 96.00 ft²
SHGC=0.26
Sgl, U=0.18 48.00 ft²
SHGC=0.10
other (see details)20.00 ft²
other (see details)
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2357.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Ext Insul, Exterior R=4.1 2140.70 ft²
b. Frame - Wood, Adjacent R=11.0 280.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 2357.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.167 ft.
Area Weighted Average SHGC:0.213
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
4
(350.8 sqft.)
(2420.7 sqft.)
(2357.0 sqft.)
(2357.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
46.5 SEER:16.00
Efficiency
k B t u / h r Efficiency
34.0 COP:1.00
f t ² R
6 200
EF: 0.980
Glass/Floor Area: 0.149
Total Proposed Modified Loads:
Total Baseline Loads:
75.71
82.42 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
11-19-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
PHILIPPE RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2357
4
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
PALM DRIVE
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2357 24389
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 MASTER BEDROO 289 3179 No 0 1 Yes Yes1 Yes
2 M WIC 1 35 350 No 0 Yes Yes1 Yes
3 M WIC 2 24 240 No 0 Yes Yes1 No
4 M HALL 16 160 No 0 Yes Yes1 No
5 LINEN 8 80 No 0 Yes Yes1 No
6 M TOILET 30 300 No 0 Yes Yes1 Yes
7 M BATH 237 2370 No 0 Yes Yes1 Yes
8 LIVING ROOM 208 2288 No 0 Yes Yes1 Yes
9 OFFICE 130 1300 No 0 Yes Yes1 Yes
10 DINING ROOM 322 3542 No 0 Yes Yes1 Yes
11 KITCHEN/FAMILY 322 3220 Yes 0 Yes Yes1 Yes
12 LAUNDRY 49 490 No 0 Yes Yes1 No
13 BEDROOM 2 138 1380 No 0 1 Yes Yes1 Yes
14 CLST 2 18 180 No 0 Yes Yes1 Yes
15 BATH 2 45 450 No 0 Yes Yes1 Yes
16 CLST 3 18 180 No 0 Yes Yes1 Yes
17 BEDROOM 3 156 1560 No 0 1 Yes Yes1 Yes
18 HALL 28 280 No 0 Yes Yes1 No
19 CLST 4 20 200 No 0 Yes Yes1 Yes
20 BEDROOM 4 162 1620 No 0 1 Yes Yes1 Yes
21 BATH 3 60 600 No 0 Yes Yes1 Yes
22 HALLWAY 42 420 No 0 Yes Yes1 Yes
11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 289 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -034 ft MASTER BEDRO
2 35 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M WIC 1
3 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2
4 16 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL
5 8 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN
6 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M TOILET
7 237 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031.6 ft M BATH
8 208 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft LIVING ROOM
9 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft OFFICE
10 322 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft DINING ROOM
11 322 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft KITCHEN/FAMIL
12 49 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY
13 138 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft BEDROOM 2
14 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2
15 45 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2
16 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3
17 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -012 ft BEDROOM 3
18 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
19 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 4
20 162 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft BEDROOM 4
21 60 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft BATH 3
22 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft HALLWAY
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 2553 ft² Medium 0.6 0 22.6______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 2357 ft² N N150
11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)30 289 ft² 0.1 Wood______MASTER BEDRO Blown
2 Under Attic (Vented)30 35 ft² 0.1 Wood______M WIC 1 Blown
3 Under Attic (Vented)30 24 ft² 0.1 Wood______M WIC 2 Blown
4 Under Attic (Vented)30 16 ft² 0.1 Wood______M HALL Blown
5 Under Attic (Vented)30 8 ft² 0.1 Wood______LINEN Blown
6 Under Attic (Vented)30 30 ft² 0.1 Wood______M TOILET Blown
7 Under Attic (Vented)30 237 ft² 0.1 Wood______M BATH Blown
8 Under Attic (Vented)30 208 ft² 0.1 Wood______LIVING ROOM Blown
9 Under Attic (Vented)30 130 ft² 0.1 Wood______OFFICE Blown
10 Under Attic (Vented)30 322 ft² 0.1 Wood______DINING ROOM Blown
11 Under Attic (Vented)30 322 ft² 0.1 Wood______KITCHEN/FAMIL Blown
12 Under Attic (Vented)30 49 ft² 0.1 Wood______LAUNDRY Blown
13 Under Attic (Vented)30 138 ft² 0.1 Wood______BEDROOM 2 Blown
14 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 2 Blown
15 Under Attic (Vented)30 45 ft² 0.1 Wood______BATH 2 Blown
16 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 3 Blown
17 Under Attic (Vented)30 156 ft² 0.1 Wood______BEDROOM 3 Blown
18 Under Attic (Vented)30 28 ft² 0.1 Wood______HALL Blown
19 Under Attic (Vented)30 20 ft² 0.1 Wood______CLST 4 Blown
20 Under Attic (Vented)30 162 ft² 0.1 Wood______BEDROOM 4 Blown
21 Under Attic (Vented)30 60 ft² 0.1 Wood______BATH 3 Blown
22 Under Attic (Vented)30 42 ft² 0.1 Wood______HALLWAY Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0MASTER BE 00017 11N Concrete Block - Ext Insul 0.60Exterior187.0 ft² ____
2 4.1 0MASTER BE 00017 11E Concrete Block - Ext Insul 0.60Exterior187.0 ft² ____
3 4.1 0M WIC 1 0007 10N Concrete Block - Ext Insul 0.60Exterior70.0 ft² ____
4 4.1 0M TOILET 0006 10N Concrete Block - Ext Insul 0.60Exterior60.0 ft² ____
5 4.1 0M BATH 00012 10N Concrete Block - Ext Insul 0.60Exterior120.0 ft² ____
6 4.1 0M BATH 0006 10S Concrete Block - Ext Insul 0.60Exterior60.0 ft² ____
7 4.1 0M BATH 00102 10SW Concrete Block - Ext Insul 0.60Exterior28.3 ft² ____
8 4.1 0M BATH 0008 10W Concrete Block - Ext Insul 0.60Exterior80.0 ft² ____
9 4.1 0M BATH 00102 10NW Concrete Block - Ext Insul 0.60Exterior28.3 ft² ____
10 4.1 0LIVING ROO 00016 11W Concrete Block - Ext Insul 0.60Exterior176.0 ft² ____
11 4.1 0OFFICE00010 10W Concrete Block - Ext Insul 0.60Exterior100.0 ft² ____
12 11 0OFFICE0006 10S Frame - Wood 0.60.1Garage60.0 ft² ____
13 4.1 0DINING ROO 00014 11E Concrete Block - Ext Insul 0.60Exterior154.0 ft² ____
14 4.1 0KITCHEN/FA 0008 10E Concrete Block - Ext Insul 0.60Exterior80.0 ft² ____
15 11 0LAUNDRY0007 10W Frame - Wood 0.60.1Garage70.0 ft² ____
16 11 0LAUNDRY0002 10S Frame - Wood 0.60.1Garage20.0 ft² ____
17 4.1 0BEDROOM 2 00010 10S Concrete Block - Ext Insul 0.60Exterior100.0 ft² ____
18 11 0BEDROOM 2 00013 10W Frame - Wood 0.60.1Garage130.0 ft² ____
11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
19 4.1 0CLST 2 0002 10S Concrete Block - Ext Insul 0.60Exterior20.0 ft² ____
20 4.1 0BATH 2 0005 10S Concrete Block - Ext Insul 0.60Exterior50.0 ft² ____
21 4.1 0CLST 3 0002 10S Concrete Block - Ext Insul 0.60Exterior20.0 ft² ____
22 4.1 0BEDROOM 3 00012 10S Concrete Block - Ext Insul 0.60Exterior120.0 ft² ____
23 4.1 0CLST 4 0002 10S Concrete Block - Ext Insul 0.60Exterior20.0 ft² ____
24 4.1 0BEDROOM 4 00013 10E Concrete Block - Ext Insul 0.60Exterior130.0 ft² ____
25 4.1 0BEDROOM 4 00012 10S Concrete Block - Ext Insul 0.60Exterior120.0 ft² ____
26 4.1 0BATH 3 00010 10N Concrete Block - Ext Insul 0.60Exterior100.0 ft² ____
27 4.1 0BATH 3 0006 10E Concrete Block - Ext Insul 0.60Exterior60.0 ft² ____
28 4.1 0HALLWAY0007 10N Concrete Block - Ext Insul 0.60Exterior70.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 N Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes1 N
2 E Low-E Single 0.42 0.26 48.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes2 N
3 SW Low-E Single 0.34 0.23 8.0 ft² 1 ft 2 in 1 ft 0 in NoneVinyl None______Yes7 N
4 W Low-E Single 0.34 0.23 12.0 ft² 1 ft 2 in 1 ft 0 in NoneVinyl None______Yes8 N
5 NW Low-E Single 0.34 0.23 8.0 ft² 1 ft 2 in 1 ft 0 in NoneVinyl None______Yes9 N
6 W Low-E Single 0.34 0.23 20.4 ft² 1 ft 2 in 0 ft 6 in NoneVinyl None______Yes10 N
7 W Low-E Single 0.18 0.1 48.0 ft² 1 ft 2 in 0 ft 4 in NoneVinyl None______Yes10 N
8 W Low-E Single 0.34 0.23 20.4 ft² 1 ft 2 in 0 ft 4 in NoneVinyl None______Yes11 N
9 E Low-E Single 0.42 0.26 48.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes13 N
10 E Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes14 N
11 S Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes17 N
12 S Low-E Single 0.34 0.23 9.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes20 N
13 S Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes22 N
14 S Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes25 N
15 N Low-E Single 0.34 0.23 9.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes26 N
16 N Low-E Single 0.16 0.1 20.0 ft² 1 ft 2 in 3 ft 0 in NoneVinyl None______Yes28 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 440 ft² 440 ft² 28 ft 10 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2845.4 7156.21.00046Wholehouse .1768293.77Proposed ACH(50)1
11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 34 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 46.5 kBtu/hr 1395 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 200 ft² Attic 20 ft² Default Leakage Garage (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 DINING
11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3
Default(8 lbs/sq.ft.f t ² f t 0.3 HALLWAY
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING
11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������