Loading...
HomeMy WebLinkAboutnew energy calcsEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 711/19/2020 9:47 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY PHILIPPE RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , PALM DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 2357 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.34 186.83 ft² SHGC=0.23 Sgl, U=0.42 96.00 ft² SHGC=0.26 Sgl, U=0.18 48.00 ft² SHGC=0.10 other (see details)20.00 ft² other (see details) 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2357.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Ext Insul, Exterior R=4.1 2140.70 ft² b. Frame - Wood, Adjacent R=11.0 280.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 2357.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.167 ft. Area Weighted Average SHGC:0.213 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 4 (350.8 sqft.) (2420.7 sqft.) (2357.0 sqft.) (2357.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 46.5 SEER:16.00 Efficiency k B t u / h r Efficiency 34.0 COP:1.00 f t ² R 6 200 EF: 0.980 Glass/Floor Area: 0.149 Total Proposed Modified Loads: Total Baseline Loads: 75.71 82.42 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 11-19-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY 1 PHILIPPE RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 2357 4 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie PALM DRIVE Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2357 24389 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 MASTER BEDROO 289 3179 No 0 1 Yes Yes1 Yes 2 M WIC 1 35 350 No 0 Yes Yes1 Yes 3 M WIC 2 24 240 No 0 Yes Yes1 No 4 M HALL 16 160 No 0 Yes Yes1 No 5 LINEN 8 80 No 0 Yes Yes1 No 6 M TOILET 30 300 No 0 Yes Yes1 Yes 7 M BATH 237 2370 No 0 Yes Yes1 Yes 8 LIVING ROOM 208 2288 No 0 Yes Yes1 Yes 9 OFFICE 130 1300 No 0 Yes Yes1 Yes 10 DINING ROOM 322 3542 No 0 Yes Yes1 Yes 11 KITCHEN/FAMILY 322 3220 Yes 0 Yes Yes1 Yes 12 LAUNDRY 49 490 No 0 Yes Yes1 No 13 BEDROOM 2 138 1380 No 0 1 Yes Yes1 Yes 14 CLST 2 18 180 No 0 Yes Yes1 Yes 15 BATH 2 45 450 No 0 Yes Yes1 Yes 16 CLST 3 18 180 No 0 Yes Yes1 Yes 17 BEDROOM 3 156 1560 No 0 1 Yes Yes1 Yes 18 HALL 28 280 No 0 Yes Yes1 No 19 CLST 4 20 200 No 0 Yes Yes1 Yes 20 BEDROOM 4 162 1620 No 0 1 Yes Yes1 Yes 21 BATH 3 60 600 No 0 Yes Yes1 Yes 22 HALLWAY 42 420 No 0 Yes Yes1 Yes 11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 289 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -034 ft MASTER BEDRO 2 35 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M WIC 1 3 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2 4 16 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL 5 8 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN 6 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M TOILET 7 237 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031.6 ft M BATH 8 208 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft LIVING ROOM 9 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft OFFICE 10 322 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft DINING ROOM 11 322 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft KITCHEN/FAMIL 12 49 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY 13 138 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft BEDROOM 2 14 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2 15 45 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 16 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3 17 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -012 ft BEDROOM 3 18 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 19 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 4 20 162 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft BEDROOM 4 21 60 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft BATH 3 22 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft HALLWAY # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 2553 ft² Medium 0.6 0 22.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 2357 ft² N N150 11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 289 ft² 0.1 Wood______MASTER BEDRO Blown 2 Under Attic (Vented)30 35 ft² 0.1 Wood______M WIC 1 Blown 3 Under Attic (Vented)30 24 ft² 0.1 Wood______M WIC 2 Blown 4 Under Attic (Vented)30 16 ft² 0.1 Wood______M HALL Blown 5 Under Attic (Vented)30 8 ft² 0.1 Wood______LINEN Blown 6 Under Attic (Vented)30 30 ft² 0.1 Wood______M TOILET Blown 7 Under Attic (Vented)30 237 ft² 0.1 Wood______M BATH Blown 8 Under Attic (Vented)30 208 ft² 0.1 Wood______LIVING ROOM Blown 9 Under Attic (Vented)30 130 ft² 0.1 Wood______OFFICE Blown 10 Under Attic (Vented)30 322 ft² 0.1 Wood______DINING ROOM Blown 11 Under Attic (Vented)30 322 ft² 0.1 Wood______KITCHEN/FAMIL Blown 12 Under Attic (Vented)30 49 ft² 0.1 Wood______LAUNDRY Blown 13 Under Attic (Vented)30 138 ft² 0.1 Wood______BEDROOM 2 Blown 14 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 2 Blown 15 Under Attic (Vented)30 45 ft² 0.1 Wood______BATH 2 Blown 16 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 3 Blown 17 Under Attic (Vented)30 156 ft² 0.1 Wood______BEDROOM 3 Blown 18 Under Attic (Vented)30 28 ft² 0.1 Wood______HALL Blown 19 Under Attic (Vented)30 20 ft² 0.1 Wood______CLST 4 Blown 20 Under Attic (Vented)30 162 ft² 0.1 Wood______BEDROOM 4 Blown 21 Under Attic (Vented)30 60 ft² 0.1 Wood______BATH 3 Blown 22 Under Attic (Vented)30 42 ft² 0.1 Wood______HALLWAY Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0MASTER BE 00017 11N Concrete Block - Ext Insul 0.60Exterior187.0 ft² ____ 2 4.1 0MASTER BE 00017 11E Concrete Block - Ext Insul 0.60Exterior187.0 ft² ____ 3 4.1 0M WIC 1 0007 10N Concrete Block - Ext Insul 0.60Exterior70.0 ft² ____ 4 4.1 0M TOILET 0006 10N Concrete Block - Ext Insul 0.60Exterior60.0 ft² ____ 5 4.1 0M BATH 00012 10N Concrete Block - Ext Insul 0.60Exterior120.0 ft² ____ 6 4.1 0M BATH 0006 10S Concrete Block - Ext Insul 0.60Exterior60.0 ft² ____ 7 4.1 0M BATH 00102 10SW Concrete Block - Ext Insul 0.60Exterior28.3 ft² ____ 8 4.1 0M BATH 0008 10W Concrete Block - Ext Insul 0.60Exterior80.0 ft² ____ 9 4.1 0M BATH 00102 10NW Concrete Block - Ext Insul 0.60Exterior28.3 ft² ____ 10 4.1 0LIVING ROO 00016 11W Concrete Block - Ext Insul 0.60Exterior176.0 ft² ____ 11 4.1 0OFFICE00010 10W Concrete Block - Ext Insul 0.60Exterior100.0 ft² ____ 12 11 0OFFICE0006 10S Frame - Wood 0.60.1Garage60.0 ft² ____ 13 4.1 0DINING ROO 00014 11E Concrete Block - Ext Insul 0.60Exterior154.0 ft² ____ 14 4.1 0KITCHEN/FA 0008 10E Concrete Block - Ext Insul 0.60Exterior80.0 ft² ____ 15 11 0LAUNDRY0007 10W Frame - Wood 0.60.1Garage70.0 ft² ____ 16 11 0LAUNDRY0002 10S Frame - Wood 0.60.1Garage20.0 ft² ____ 17 4.1 0BEDROOM 2 00010 10S Concrete Block - Ext Insul 0.60Exterior100.0 ft² ____ 18 11 0BEDROOM 2 00013 10W Frame - Wood 0.60.1Garage130.0 ft² ____ 11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 19 4.1 0CLST 2 0002 10S Concrete Block - Ext Insul 0.60Exterior20.0 ft² ____ 20 4.1 0BATH 2 0005 10S Concrete Block - Ext Insul 0.60Exterior50.0 ft² ____ 21 4.1 0CLST 3 0002 10S Concrete Block - Ext Insul 0.60Exterior20.0 ft² ____ 22 4.1 0BEDROOM 3 00012 10S Concrete Block - Ext Insul 0.60Exterior120.0 ft² ____ 23 4.1 0CLST 4 0002 10S Concrete Block - Ext Insul 0.60Exterior20.0 ft² ____ 24 4.1 0BEDROOM 4 00013 10E Concrete Block - Ext Insul 0.60Exterior130.0 ft² ____ 25 4.1 0BEDROOM 4 00012 10S Concrete Block - Ext Insul 0.60Exterior120.0 ft² ____ 26 4.1 0BATH 3 00010 10N Concrete Block - Ext Insul 0.60Exterior100.0 ft² ____ 27 4.1 0BATH 3 0006 10E Concrete Block - Ext Insul 0.60Exterior60.0 ft² ____ 28 4.1 0HALLWAY0007 10N Concrete Block - Ext Insul 0.60Exterior70.0 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes1 N 2 E Low-E Single 0.42 0.26 48.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes2 N 3 SW Low-E Single 0.34 0.23 8.0 ft² 1 ft 2 in 1 ft 0 in NoneVinyl None______Yes7 N 4 W Low-E Single 0.34 0.23 12.0 ft² 1 ft 2 in 1 ft 0 in NoneVinyl None______Yes8 N 5 NW Low-E Single 0.34 0.23 8.0 ft² 1 ft 2 in 1 ft 0 in NoneVinyl None______Yes9 N 6 W Low-E Single 0.34 0.23 20.4 ft² 1 ft 2 in 0 ft 6 in NoneVinyl None______Yes10 N 7 W Low-E Single 0.18 0.1 48.0 ft² 1 ft 2 in 0 ft 4 in NoneVinyl None______Yes10 N 8 W Low-E Single 0.34 0.23 20.4 ft² 1 ft 2 in 0 ft 4 in NoneVinyl None______Yes11 N 9 E Low-E Single 0.42 0.26 48.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes13 N 10 E Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes14 N 11 S Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes17 N 12 S Low-E Single 0.34 0.23 9.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes20 N 13 S Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes22 N 14 S Low-E Single 0.34 0.23 20.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes25 N 15 N Low-E Single 0.34 0.23 9.0 ft² 1 ft 2 in 2 ft 0 in NoneVinyl None______Yes26 N 16 N Low-E Single 0.16 0.1 20.0 ft² 1 ft 2 in 3 ft 0 in NoneVinyl None______Yes28 N # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 440 ft² 440 ft² 28 ft 10 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2845.4 7156.21.00046Wholehouse .1768293.77Proposed ACH(50)1 11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 34 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 46.5 kBtu/hr 1395 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 200 ft² Attic 20 ft² Default Leakage Garage (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 DINING 11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3 Default(8 lbs/sq.ft.f t ² f t 0.3 HALLWAY Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING 11/19/2020 9:47 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������