HomeMy WebLinkAboutPA FL9777-R11usiness
aProfessionalRegulation=
DOS Horne i Cng In ; User Regl stration Hat Topics Submit Surcharge StaCs & Facts PublicdUORs Contact Use OCIS Site Map } Links ] 'Search
b
� r
"i Product Approval
USER: P.blic User
;11aria, TA
!{H'�1pAiIPr�.
v I Menu > PrMtu!--LQr Aoolication,Searrh a A ii List? Application detail
R # FL9777-R11
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg. keeler@owensccrning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning,com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Gurnpliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL2777 R11 MI OCRI4002,aa-2—Q17 FBC Fyalu tion part W lack
N�HVHZ.ndfHZ.ndf
Referenced Standard and Year (of Standard) Sta randard Year
ASTM D 1970 2015
ASTM D 226 2009
ASTM G 155 2005
https://www.floridabuilding.org/pr/pr_app-dtl.aspx?param=wGEVXQWIDqtgkcMGbfCW7i%2fZr7gdugvKFlMFg53ndV60188SS636Kw%3d943d Page 1 of 3
TAS 103
UL 1897
Equivalence of Product Standards
Certified By
Sections from the Code
Product. Approval Method Method 1 Option D
Date Submitted
10/11/2017
Date Validated
101111201.7
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
1995
2012
FL #
Model, Number or Name
Description
9777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL9777._R11 IT OCRI4002.8a 2,Q7 FBC
Ev Ion Refer
Weatherlock„Nan-HVFZ,P�f
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL977 Ri 1 A_4_pCR1.4002.a 2017 F5Qjv4luation
Rt Wort
Weatherlock Non-HVHZ.pddf
Created by Independent Third Party: Yes
9777.2 Wee therLockG (High Tear)
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for ilmits of use,
FL9777 —R1LjJ—QCR14QQZ.3a 2DI7 FaQ
F..valu n par
WPathQrlock Non_ HVHZ,pdf
Verified By, Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
F =7 111 At—QCR140Q2&a 2017 F
aluati n Re ort
Votherlock,N2n-HVHZ.,:. d
Created by Independent Third Party: Yes
9777.3
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
FL9777 911. II QCR14002 8b F8C
Eva,lpation Report
„2„Q17
Weatherlock HVHZ pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
F 41, 777 R11 A.E OCR14QQ.2,8b 2017 FBC
Evaluation Report
Weatherlock HVHZ.pdf
Created by Independent Third Party: Yes
9777.4 Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
~
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for lim[ts of use.
FL2777 R11 II_QCR14fl,(]2, 3a 2017 FQr'
Eva1uation-2.06rt
Weatherlock Non-UVHZ.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 Rli AE 140 2017 FB
val a ' n Re or
W herlo k -HVH .Qdf
Created by Independent Third Party: Yes
https:1,'www.floridahullding.org/pr/pr app_dtl.aspx?pa ram=wGEVXQwtDgtgkcMGbIcW7I%2fZr7gdugvKEl MFg53ndV601883563GKw%3d%3d Page 2 of 3
9777.-5
WeatherLock Metal
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: Na
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evacuation report for limits of use.
Installation Instructions
F 7 _R11 II Cit14QQ2._8a 2017 FBC EvaUrdtion Re=
W+ erlock„I�,�n-HVHZ oft
Verified By: Zachary R. Priest PE-74021
Created by Independent Third. Party: Yes
Evaluation Reports
FL977Z R11 AE CR14QQ2.8a 2017„FBC EyalirsItion Report
Weathgrlock N,Q,n-HVHZ �f
Created by Independent Third Parry: Yes
k
9777.6 WeatherLock Metal
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Installation Instructions
FIg777 R11 II OCRI40 2. b 2 17 FB Ev ! i R
Weatherlock HVHZ.vdf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use,
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R1�9E O�Rj4002.8b 2(j„t7_Fi3C Ev��,>�a#ion Reprrt
VYeatherlock, HVHZ.pdf
Created by Independent Third Party: Yes
9777.7 Weather -Lock Specialty Tile & Metal
Weatherproofing Underfayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-142,5
Other: See evaluation report for limits of use.
F_L9777 R II OCR4002 8a,Q17_FBC Ey„„Blltation R�got
Bath rl k n HV
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R11_ E OCR14 .8a 1 EEC Ev I ion R pQ2r
ffuther k Non-HVHZ.pljf
Created by Independent Third Party: Yes
back N21(t
CQUldct Us :: 201 $lalr Stone Road, Tallahassee FL 32394 PhOng,- J350-487-1824
The State Of Florida is an nn/EEO employer. f a%ijiight 2UOi-2q;t3_Statp of Florida.:: Pri m :: Accesslbllity Statement :: RI-Nno S
taterren
Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a publio-records request, do not sercd electronic
mall to this entity. Instead, cvntad the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.5- must provide the Department with an email address if they have
one. The emails provided may be used for Official communication wlth the licensee. However email addresses are public record. If you do not wlsh W supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
M FOR 6CtxA
Credit Cara
,safe
https:J/www:floridahuiIding.orgipr/pr_app_dtl.aspx?param=wGEVXDWtDglgkcMGblcW71%2fZr7gdugvKEIMFg53ndVGol883s636Kw%3d%3d Page 3 of 3
Certificate of Authorization No. 29824
CREEK17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL, SERVICES, LLC (813)480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 6"` EDITION (2017)
Manufacturer:
OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438-7465
wwuv.owenscamnq r,Qm
Manufacturing Location:
Brentwood, NH
Houston, TX
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1, 1507.1-1
Properties:
Physical properties
REFERENCES
EntltV
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
NEI-039-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-042-02-01 REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NEI-045-02-01
TAS 103
1995
PRE Construction Materials Technologies (TST5878)
NEI-045-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
NEI-093-02-D2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-237-02-o1
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM ❑ 4798
2001
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-253-02-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-272-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
ICC-ES AC 188'
2012
ICC-ES AC A8
2012
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-318-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-355-02-01
UL 1897
2012
'Determined to be equivalent to ASTM D 226-09, Type I
and II
OCR14002.8a FL9777-R11 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
CREEK
T£CHN1CAt_ SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockO Self -Sealing Ice & Water Barriers
WeatherLock® G
WeatherLock® G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood, NH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66-7-tt.
Weatherl-ockO G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanical[y attached roofing coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Mat
Weatherl-ock2) Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH or
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, T)O
sq. rolls with nominai dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLockg Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock® Metal
WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. roils with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock®
WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, TX)
WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock(9 Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BOND F"" Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock® G (High
WeatherLock® G (High Tear) is a self -adhered, underlayment used as an alternative to
Tear)
ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
(Houston, T)O
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
WeatherLock& G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-Rl l Page 2 of 4
This evaluation report is provided for State or Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services; LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
OWAENS CORNING ROOFING AND ASPHALT LLC
CREEK WeatherLockO Self -Sealing Ice & Water Barriers
A
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All underlayments shall be installed in accordance with the FBC.
Deck substrates shaft be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the unde,dayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 5° end laps staggered min. 6-ft.from preceding course. Additionally. if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM ❑
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap
Itis permissible to back nall the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when Installed on roof slopes greater than 3.12,
Mir. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9
UnderlaVment System No.1 — WeatherLock Specialty Tile & Metal Only
Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's Installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofng nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 7blb steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-R11 Page 3 of
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty. installation, recommended use. or other product attributes that are not
-.moo.. VI—II"'A./race d 1.orni..
CREEK
TECHNICAL SERVICES, LLC
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockg Self -Sealing Ice & Water Barriers
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FRC requirements to resist the design wind
load pressures for components and Gadding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined forthe roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6t" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
No 74021
: X
STATE OF ='�!
ri���{�'•,. ( ORIN A
t p ,. C?ti tom■■
CERTIFICATION OF INDEPENDENCE
2017.10.
09:06:29
.y.~.~-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluatlon_
Zachary R. Priest, P.E. does not have. nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.8a FL9777-R11 Page d of 4
This evaluation report is provided for State of Florida product approval under Rule fit G20-3_ The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
�..ordFl..�ll.�.�,{`{roccori horq,h