Loading...
HomeMy WebLinkAboutPA FL9777-R11usiness aProfessionalRegulation= DOS Horne i Cng In ; User Regl stration Hat Topics Submit Surcharge StaCs & Facts PublicdUORs Contact Use OCIS Site Map } Links ] 'Search b � r "i Product Approval USER: P.blic User ;11aria, TA !{H'�1pAiIPr�. v I Menu > PrMtu!--LQr Aoolication,Searrh a A ii List? Application detail R # FL9777-R11 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg. keeler@owensccrning.com Authorized Signature Greg Keeler greg.keeler@owenscorning,com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Gurnpliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL2777 R11 MI OCRI4002,aa-2—Q17 FBC Fyalu tion part W lack N�HVHZ.ndfHZ.ndf Referenced Standard and Year (of Standard) Sta randard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2005 https://www.floridabuilding.org/pr/pr_app-dtl.aspx?param=wGEVXQWIDqtgkcMGbfCW7i%2fZr7gdugvKFlMFg53ndV60188SS636Kw%3d943d Page 1 of 3 TAS 103 UL 1897 Equivalence of Product Standards Certified By Sections from the Code Product. Approval Method Method 1 Option D Date Submitted 10/11/2017 Date Validated 101111201.7 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products 1995 2012 FL # Model, Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL9777._R11 IT OCRI4002.8a 2,Q7 FBC Ev Ion Refer Weatherlock„Nan-HVFZ,P�f Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL977 Ri 1 A_4_pCR1.4002.a 2017 F5Qjv4luation Rt Wort Weatherlock Non-HVHZ.pddf Created by Independent Third Party: Yes 9777.2 Wee therLockG (High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for ilmits of use, FL9777 —R1LjJ—QCR14QQZ.3a 2DI7 FaQ F..valu n par WPathQrlock Non_ HVHZ,pdf Verified By, Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports F =7 111 At—QCR140Q2&a 2017 F aluati n Re ort Votherlock,N2n-HVHZ.,:. d Created by Independent Third Party: Yes 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. FL9777 911. II QCR14002 8b F8C Eva,lpation Report „2„Q17 Weatherlock HVHZ pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports F 41, 777 R11 A.E OCR14QQ.2,8b 2017 FBC Evaluation Report Weatherlock HVHZ.pdf Created by Independent Third Party: Yes 9777.4 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions ~ Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for lim[ts of use. FL2777 R11 II_QCR14fl,(]2, 3a 2017 FQr' Eva1uation-2.06rt Weatherlock Non-UVHZ.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 Rli AE 140 2017 FB val a ' n Re or W herlo k -HVH .Qdf Created by Independent Third Party: Yes https:1,'www.floridahullding.org/pr/pr app_dtl.aspx?pa ram=wGEVXQwtDgtgkcMGbIcW7I%2fZr7gdugvKEl MFg53ndV601883563GKw%3d%3d Page 2 of 3 9777.-5 WeatherLock Metal Weatherproofing Underlayment Limits of Use Approved for use in HVHZ: Na Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evacuation report for limits of use. Installation Instructions F 7 _R11 II Cit14QQ2._8a 2017 FBC EvaUrdtion Re= W+ erlock„I�,�n-HVHZ oft Verified By: Zachary R. Priest PE-74021 Created by Independent Third. Party: Yes Evaluation Reports FL977Z R11 AE CR14QQ2.8a 2017„FBC EyalirsItion Report Weathgrlock N,Q,n-HVHZ �f Created by Independent Third Parry: Yes k 9777.6 WeatherLock Metal Weatherproofing Underlayment Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Installation Instructions FIg777 R11 II OCRI40 2. b 2 17 FB Ev ! i R Weatherlock HVHZ.vdf Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use, Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R1�9E O�Rj4002.8b 2(j„t7_Fi3C Ev��,>�a#ion Reprrt VYeatherlock, HVHZ.pdf Created by Independent Third Party: Yes 9777.7 Weather -Lock Specialty Tile & Metal Weatherproofing Underfayment Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-142,5 Other: See evaluation report for limits of use. F_L9777 R II OCR4002 8a,Q17_FBC Ey„„Blltation R�got Bath rl k n HV Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11_ E OCR14 .8a 1 EEC Ev I ion R pQ2r ffuther k Non-HVHZ.pljf Created by Independent Third Party: Yes back N21(t CQUldct Us :: 201 $lalr Stone Road, Tallahassee FL 32394 PhOng,- J350-487-1824 The State Of Florida is an nn/EEO employer. f a%ijiight 2UOi-2q;t3_Statp of Florida.:: Pri m :: Accesslbllity Statement :: RI-Nno S taterren Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a publio-records request, do not sercd electronic mall to this entity. Instead, cvntad the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.5- must provide the Department with an email address if they have one. The emails provided may be used for Official communication wlth the licensee. However email addresses are public record. If you do not wlsh W supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M FOR 6CtxA Credit Cara ,safe https:J/www:floridahuiIding.orgipr/pr_app_dtl.aspx?param=wGEVXDWtDglgkcMGblcW71%2fZr7gdugvKEIMFg53ndVGol883s636Kw%3d%3d Page 3 of 3 Certificate of Authorization No. 29824 CREEK17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL, SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6"` EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7465 wwuv.owenscamnq r,Qm Manufacturing Location: Brentwood, NH Houston, TX Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1-1 Properties: Physical properties REFERENCES EntltV Report No. Standard Year PRI Construction Materials Technologies (TST5878) NEI-039-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-045-02-01 TAS 103 1995 PRE Construction Materials Technologies (TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-093-02-D2 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-237-02-o1 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM ❑ 4798 2001 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC A8 2012 PRI Construction Materials Technologies (TST5878) OCF-297-02-01.1 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-318-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-321-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-322-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF-355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09, Type I and II OCR14002.8a FL9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not CREEK T£CHN1CAt_ SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING ROOFING AND ASPHALT LLC WeatherLockO Self -Sealing Ice & Water Barriers WeatherLock® G WeatherLock® G is an ASTM D 1970 self-adhesive underlayment constructed from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66-7-tt. Weatherl-ockO G is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanical[y attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Mat Weatherl-ock2) Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, T)O sq. rolls with nominai dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLockg Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Metal WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. roils with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock® WeatherLock® Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. (Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, TX) WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock(9 Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.) or TILE BOND F"" Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock® G (High WeatherLock® G (High Tear) is a self -adhered, underlayment used as an alternative to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer (Houston, T)O modified bitumen underlayment. The underlayment is composed of SBS modified asphalt with a fberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLock& G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FL9777-Rl l Page 2 of 4 This evaluation report is provided for State or Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services; LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not OWAENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLockO Self -Sealing Ice & Water Barriers A TECHNICAL SERVICES, LLC PRODUCT APPLICATION Min. Roof Slope: 2:12 in accordance with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shaft be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the unde,dayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 5° end laps staggered min. 6-ft.from preceding course. Additionally. if applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM ❑ 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap Itis permissible to back nall the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when Installed on roof slopes greater than 3.12, Mir. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9 UnderlaVment System No.1 — WeatherLock Specialty Tile & Metal Only Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's Installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofng nails through optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 7blb steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-R11 Page 3 of This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty. installation, recommended use. or other product attributes that are not -.moo.. VI—II"'A./race d 1.orni.. CREEK TECHNICAL SERVICES, LLC OWENS CORNING ROOFING AND ASPHALT LLC WeatherLockg Self -Sealing Ice & Water Barriers GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FRC requirements to resist the design wind load pressures for components and Gadding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined forthe roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6t" Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. No 74021 : X STATE OF ='�! ri���{�'•,. ( ORIN A t p ,. C?ti tom■■ CERTIFICATION OF INDEPENDENCE 2017.10. 09:06:29 .y.~.~-04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluatlon_ Zachary R. Priest, P.E. does not have. nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.8a FL9777-R11 Page d of 4 This evaluation report is provided for State of Florida product approval under Rule fit G20-3_ The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not �..ordFl..�ll.�.�,{`{roccori horq,h