Loading...
HomeMy WebLinkAboutPA FL16918-R2i Professionalf fig BCIS Home i Log In I User RegistratEon j Hot TapreS Submit Surcharge y Stats & Facts Fubli.ati0nns I contact Us BCIs site Map links r Search d. * Product Approval r 4 USER: Public User P[Qduct Approval Menu > Ercduct or A li " n Search, U,plisation List a Application Detail FL # FL16918-R2 Application Type Revision Code Version 2017 Application Status Approved Comments QA entity has been called into question. I L113118 Archived Product Manufacturer L.V. Thompson, Inc. dba Thompson Architectural Metals Company {TAMCO) Address/Phone/Email 5015 East Hillsborough Ave. Tampa, FL 33610 (813)248-3456 tany@gometal roofi ng. cam Authorized Signature Technical Representative Address/Phone/Emall Quality Assurance Representative Add ress/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Tony Christman tony@gometalroofing.com Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Zachary R. Priest PE-74021 Keystone Certifications, Inc. 09/09/2026 Locke Bowden P.E. Validation Checklist - Hardcopy Received FI 15918 R2-QQJ_LVT140Qt,2a 2017Lag Eyal__ cation Report QfL-Ridgg V n fin 1, df Standarg Yvar ASTM E 330 2002 TAS 100(A) 1995 Sections From the Code Product Approval Method Method 1 Option ❑ Date Submitted 10/10/2D17 Date Validated 10/10/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/1212017 Summary of Products FL 0 _ w v Model, Number or Name Description 16918.1 TAMCO Flat Top Off -Ridge Vent with 26 ga. static roof ventilator with baffle Baffle for Tile Limits of Use Installation Instructions Approved for use in 14VHZ: Yes Approved for use outside HVHZ: Yes XmIact Resistant: W/A FL16218 P12 II c 20 I-;— RepQ Flat Too Off Ridge Vent final pAf Verified By: Zachary R. Priest PE-74021 Design Pressure: MIA Otter: See evaluation report for limits of use. Created by Independent Third Party: Yes evaluation Reports a 3 R2_A7= 4 VE14001.2c 2011EBC Evaluation RQR= Flat 7Q Created by Independent Third Party: Yes I 1&918.2 TAMCO Gooseneck Vent 26 ga. units of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes F 1� fi91[L-R2 01.2 7 F Eval i C is Vent OMHVHZ final.qdf Impact Resistant: N/A Design Pressures +0/-5ZS Other: See evaluation report for limits of use. Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL1691.$� Goosen t n pdf S Created by Independent Third Party: Yes I - 163.1 TAPS .CO Off Ridge. Roof.Vent..with S:afEle 26 ga. static roof ventilator with integrated baffle Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16918 g-u_ Approved for use outside H► HZ: Yes Of - i nt final Impact Resistant: NfA Design Pressu m: N/A Other: See evaluation report for limits of use. Verified By: Zachary R. Priest 74021 Created by Independent Third Party, Yes Evaluation Reports F 1L 5918 R2 �{� LVT14001.2.d,_{�17 PBC Ev2�[!�,, an Report Ff R' Vertt Fnal Created by Independent Third Party: Yes 1,6918.4 TAMCO Round Top Off -Ridge Vent 26 ga. static root ventilator with baffle with Baffle for Tile Limits of Use Installation Instructions Approved for use in HVHZ: Yes .,Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. fLI-6918 !3 _j _LVT14001. ,�, �017 FBC Ey,, yl.Ii. ion RPpQr Round_Tap-Off-Ridr:�_Vent final,pdf Verified By; Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports ELIEM LYLi_4SL+a1.zb zo17 FP Fva!rsaQ.tk Ro -Rid V .fllal•odf Created by Independent Third Party: Yes Cant&, Crs :: M122 Milk Stong Road, TWlahassee-R-itl4fle: 850-487-1824 -the State or Rwida is an A VEEo employer. �Y�4t1f e��7-2�7Z3 State of Florida_ ;: pavacy Stuament _: &Cce�, ment :: Refund SCaYement tinder Florida Wet email, addresses are putjl c records. if you do not want your a -mail address released in response to a public -records request, do not send a€actrvnic mail to 5his entity instead, contact the office by phone or by traditional mail, if you have any questions, please contact 550.487.095. -Pursuant to section 455.275(I), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emall address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you d❑ not wish to supply a personal address, please pmvide the Department with an emall address which can be made availsple to the public. To determine it you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts; Credit Caret ,safe Certificate of Authorization No. 29824 CREEK17520 Edinburgh drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6r" EDITION (2017) Manufacturer: L.V. Thompson, Inc. Issued October9, 2017 dba Thompson Architectural Metals Company (TAMCO) 5015 E. Hillsborough Ave Tampa, FL 33610 (813) 248-3456 http:[/vww.tamcometalroof.com Manufacturing Plant: Tampa, FL Quality Assurance: Keystone Certifications (QUA1824) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an fntegral Part of the Roofing System Code Sections: 1503.5, 1523.6.5.2.13 Properties: Roof Ventilation REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) LVfI-012-02-01 TAS 100(A) 1995 PRODUCT DESCRIPTION External Baffle` Mounting flange TAMCO Off -Ridge Roof Minimum 26 ga. ASTM A792 AZ50 (non-HVHZ only) or ASTM A653 G90 steel off -ridge Vent with Baffle static roof ventilator with integrated baffle offset from the intake. Vent dimensions are 24" wide x 4-114" high and is available in nominal lengths of 4-fir 6-ft, 8-ft and 10-ft. Material shall conform with FBC Section 1507.4.3 (non-HVHZ) and 1517.6 (HVHZ). LVT14001.2a FL15918-R2 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. REEK L.V. Thompson, Inc. (TAMCO) TAMCO Off -Ridge Roof Vent with Baffle TECHNICAL SERVICES, LLC APPLICATION Deck Type: Minimum 15132-inch APA span rated plywood sheathing for new and existing roof deck; Min. 19132-inch APA span rated plywood sheathing in the 1 fVHZ for new construction. (Deck shall be designed by others in accordance with FBC requirements) Roof slope.: Minimum 4:12 Installation Height: Maximum 33-ft Attachment Method: Cut-out a 3-inch opening sized according to manufacturer's instructions into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM D 4586 or ASTM D 3409, Type i roofing cement/mastic to the underside of the vent flange at both the inside and outside perimeter and to continuously surround and seal the flange. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with galvanized or stainless steel roofing nails having minimum 12 ga_ shank, minimum 3/a-Inch diameter head and sufficient length to penetrate through the sheathing (ring shank nails shall be used in the HVHZ). Nails shall be located 1-inch from the edge of the flange and 8-inch o.c- along all four sides of the vent. All exposed fasteners shall be sealed with roofing cementfmastic. All loosened shingles shall be adhered down with roof cement/mastic. Typieal S" O.C. MAX V f O �Q Star rtl Off Rbd�-- Vent 4vM Permanent Baffle Q ❑ O 0 a o ❑ 0 0 0 0 I LNails: 11 Ga. mart. 1-1W Corrosion Resistant. Smooth Roofing Nails Spacing: 8" D.C. MAX and I"From Outer Edge Flange Allowable Roof Coverings: Asphalt shingles LVT14001.2a FL16918-R2 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, instaflatfon, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICEs, Ll LIMITATIONS L.V. Thompson, Inc. (TAMCQ) TAMCQ Off -Ridge Roof Vent with Baffle 1) Fire Classification is outside the scope of this evaluation. 2) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 3) TAMCQ vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 5) Installation of the roof assembly is outside the scope of this evaluation. 6) TAMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 6 Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. {►{liftII11jr1 Sr��� R, P "Fee* % C3 �� ��0 €vo 74021 STATE OF • �= : A- �#, fail 0 CERTIFICATION OF INDEPENDENCE 2017.10.09 18:14:52 -D4W Zachary R. Priest, P.E. Florida Registration No. 74621 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT LV7140012a FL16918-R2 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREFK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.