HomeMy WebLinkAboutFL11136_R8_II_D015024 Contours Energy Saver SE IS OPQ SS 2019-04-25 (DOOR)JELDr'WEN® Steel STEEL, STEEL EDGE DOOR 6'-8" & 8'-0" SINGLE INSWING OPAQUE IMPACT DOOR GENERALNOTES 1. THIS PRODUCT IS DESIGNED TO COMPLY WITH THE FLORIDA CURRENT BUILDING CODE INCLUDING "HIGH VELOCITY HURRICANE ZONE" (HVHZ) REQUIREMENTS. 2. WOOD BUCKS, BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. 3. PRODUCT ANCHORS SHALL BE AS LISTED AND SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 4. IMPACT RESISTANT SHUTTERS NOT REQUIRED. 5. DESIGN PRESSURE RATING SHALL BE AS FOLLOWS: —FOR 6'8" WOOD FRAMES — SEE TABLE SHEET 1 —FOR 8'0" WOOD FRAMES — SEE TABLE SHEET 1 6. THIS SYSTEM WAS TESTED FOR 2.86 LBS. WATER PRESSURE AS PER ASTM—E331. 7. THIS PRODUCT DOES NOT MEET THE WATER REQUIREMENTS FOR "HVHZ". INSWING IMPACT STEEL EDGE DOOR (Common to all frame conditions) DOOR LEAF CONSTRUCTION: Face sheets: 24 ga. (0.020") minimum thickness, Galvanized Steel A-525 commercial quality — AKDQ per ASTM 620 with minimum average yield strength Fy=26,240 psi. Core design: by JELD—WEN. Panel Construction: Steel face sheets glued to door core, with steel top and bottom rails and steel stiles with a wood lock block reinforcement. The hinge stile contains a MDF board for added hinge support. Frame Construction (Both Frame Types): The head jambs and side jambs are mortised, butted and joined using (3) 7/8" x 2" wire staples. An aluminum adjustable inswing threshold was unitilized at the sill. An optional aluminum ADA threshold is available. TABLE OF CONTENTS 5 UNIT COMPONENTS 11 LL SHT # DESCRIPTION 1 TYPICAL ELEVATIONS &GENERAL NOTES 2 VERTICAL CROSS SECTIONS & BOM 3 HORIZONTAL CROSS SECTIONS & MODELS 4 ANCHORING LOCATIONS & DETAILS 00 00 to 3'-1 3/4" O.A. MAX. FRAME WIDTH 3' O.A. MAX. PANEL WIDTH D ® ® Q i- c� F =w = ox o ww = xg J W w X 28 a .� X � Q 0 B q o` 3 0 � -�� s PO O � � � v I O rn� io I 6'8" SINGLE INSWING UNIT (X) SCALE: 1/2" =>'-0" 3'-1 3/4" O.A. MAX. FRAME WIDTH 3' O.A. MAX. PANEL WIDTH I> �I!I IN-1 27 8'0" SINGLE INSWING UNIT (X) � OVERHANG SCALE: 1/2" _ % '— O" LENGTH ALL DOOR MODELS ARE VIEWED FROM THE INTERIOR SIDE DESIGN PRESSURE RATING FRAME PANEL *WHERE WATER INFILTRATION WHERE WATER INFILTRATION DIMENSIONS HEIGHT REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED 82 37'5'X 6'8" (X) +65.Opsf—70.Opsf +65.Opsf—70.Opsf 37.75" X 8'0" (X) +61.Opsf—65.Opsf +61.Opsf—65.Opsf 93.375" 1.0) 1 1 1 1 1 1 x c� OG 2 *NOTE: PRODUCT HAS NOT BEEN RATED FOR y WATER INFILTRATION. IF AUTHORITY HAVING oy JURISDICTION REQUIRES THAT PRODUCT MEETS 0 x > THIS REQUIREMENT, PRODUCT SHALL BE USED o � WHEN INSTALLED AT LOCATION PROTECTED BY o OVERHANG SUCH THAT OVERHANG (OH) RAT,I(Xlll,.. f1I/i = OH LENGTH - OH HEIGHT IS ? Digitally signed by Hermes F Norero Reason: I am approving this document N Date: 2019.04.25 13:51:59-04'00' -0 S q O O nF��JJA; B FBPE Certific6t� to/ j CO 0 J � m 0 z O ¢ chi z W `L � W Y = CC) W N ¢ _ � MYCL W N 48 �IN 'IW � Ylm CM 99 0 N_ I , I - N O cD M a)\ W N — — — 0 1-- \0\0 N r- \Q oo—oDATE: 12107107 00 V7 0 � SCALE: AS NOTED * � DWG. BY: EAG = OF Q� � CHK. eY:S. SAFFELI IDP.� • �� �� DRAWING NO.: No D015024 B LV[i� 29578 I SHEET 1 OF 5 11 LL SHT # DESCRIPTION 1 TYPICAL ELEVATIONS &GENERAL NOTES 2 VERTICAL CROSS SECTIONS & BOM 3 HORIZONTAL CROSS SECTIONS & MODELS 4 ANCHORING LOCATIONS & DETAILS 00 00 to 3'-1 3/4" O.A. MAX. FRAME WIDTH 3' O.A. MAX. PANEL WIDTH D ® ® Q i- c� F =w = ox o ww = xg J W w X 28 a .� X � Q 0 B q o` 3 0 � -�� s PO O � � � v I O rn� io I 6'8" SINGLE INSWING UNIT (X) SCALE: 1/2" =>'-0" 3'-1 3/4" O.A. MAX. FRAME WIDTH 3' O.A. MAX. PANEL WIDTH I> �I!I IN-1 27 8'0" SINGLE INSWING UNIT (X) � OVERHANG SCALE: 1/2" _ % '— O" LENGTH ALL DOOR MODELS ARE VIEWED FROM THE INTERIOR SIDE DESIGN PRESSURE RATING FRAME PANEL *WHERE WATER INFILTRATION WHERE WATER INFILTRATION DIMENSIONS HEIGHT REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED 82 37'5'X 6'8" (X) +65.Opsf—70.Opsf +65.Opsf—70.Opsf 37.75" X 8'0" (X) +61.Opsf—65.Opsf +61.Opsf—65.Opsf 93.375" 1.0) 1 1 1 1 1 1 x c� OG 2 *NOTE: PRODUCT HAS NOT BEEN RATED FOR y WATER INFILTRATION. IF AUTHORITY HAVING oy JURISDICTION REQUIRES THAT PRODUCT MEETS 0 x > THIS REQUIREMENT, PRODUCT SHALL BE USED o � WHEN INSTALLED AT LOCATION PROTECTED BY o OVERHANG SUCH THAT OVERHANG (OH) RAT,I(Xlll,.. f1I/i = OH LENGTH - OH HEIGHT IS ? Digitally signed by Hermes F Norero Reason: I am approving this document N Date: 2019.04.25 13:51:59-04'00' -0 S q O O nF��JJA; B FBPE Certific6t� to/ j CO 0 J � m 0 z O ¢ chi z W `L � W Y = CC) W N ¢ _ � MYCL W N 48 �IN 'IW � Ylm CM 99 0 N_ I , I - N O cD M a)\ W N — — — 0 1-- \0\0 N r- \Q oo—oDATE: 12107107 00 V7 0 � SCALE: AS NOTED * � DWG. BY: EAG = OF Q� � CHK. eY:S. SAFFELI IDP.� • �� �� DRAWING NO.: No D015024 B LV[i� 29578 I SHEET 1 OF 5 3'-1 3/4" O.A. MAX. FRAME WIDTH 3' O.A. MAX. PANEL WIDTH D ® ® Q i- c� F =w = ox o ww = xg J W w X 28 a .� X � Q 0 B q o` 3 0 � -�� s PO O � � � v I O rn� io I 6'8" SINGLE INSWING UNIT (X) SCALE: 1/2" =>'-0" 3'-1 3/4" O.A. MAX. FRAME WIDTH 3' O.A. MAX. PANEL WIDTH I> �I!I IN-1 27 8'0" SINGLE INSWING UNIT (X) � OVERHANG SCALE: 1/2" _ % '— O" LENGTH ALL DOOR MODELS ARE VIEWED FROM THE INTERIOR SIDE DESIGN PRESSURE RATING FRAME PANEL *WHERE WATER INFILTRATION WHERE WATER INFILTRATION DIMENSIONS HEIGHT REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED 82 37'5'X 6'8" (X) +65.Opsf—70.Opsf +65.Opsf—70.Opsf 37.75" X 8'0" (X) +61.Opsf—65.Opsf +61.Opsf—65.Opsf 93.375" 1.0) 1 1 1 1 1 1 x c� OG 2 *NOTE: PRODUCT HAS NOT BEEN RATED FOR y WATER INFILTRATION. IF AUTHORITY HAVING oy JURISDICTION REQUIRES THAT PRODUCT MEETS 0 x > THIS REQUIREMENT, PRODUCT SHALL BE USED o � WHEN INSTALLED AT LOCATION PROTECTED BY o OVERHANG SUCH THAT OVERHANG (OH) RAT,I(Xlll,.. f1I/i = OH LENGTH - OH HEIGHT IS ? Digitally signed by Hermes F Norero Reason: I am approving this document N Date: 2019.04.25 13:51:59-04'00' -0 S q O O nF��JJA; B FBPE Certific6t� to/ j CO 0 J � m 0 z O ¢ chi z W `L � W Y = CC) W N ¢ _ � MYCL W N 48 �IN 'IW � Ylm CM 99 0 N_ I , I - N O cD M a)\ W N — — — 0 1-- \0\0 N r- \Q oo—oDATE: 12107107 00 V7 0 � SCALE: AS NOTED * � DWG. BY: EAG = OF Q� � CHK. eY:S. SAFFELI IDP.� • �� �� DRAWING NO.: No D015024 B LV[i� 29578 I SHEET 1 OF 5 1 1 1 1 1 1 x c� OG 2 *NOTE: PRODUCT HAS NOT BEEN RATED FOR y WATER INFILTRATION. IF AUTHORITY HAVING oy JURISDICTION REQUIRES THAT PRODUCT MEETS 0 x > THIS REQUIREMENT, PRODUCT SHALL BE USED o � WHEN INSTALLED AT LOCATION PROTECTED BY o OVERHANG SUCH THAT OVERHANG (OH) RAT,I(Xlll,.. f1I/i = OH LENGTH - OH HEIGHT IS ? Digitally signed by Hermes F Norero Reason: I am approving this document N Date: 2019.04.25 13:51:59-04'00' -0 S q O O nF��JJA; B FBPE Certific6t� to/ j CO 0 J � m 0 z O ¢ chi z W `L � W Y = CC) W N ¢ _ � MYCL W N 48 �IN 'IW � Ylm CM 99 0 N_ I , I - N O cD M a)\ W N — — — 0 1-- \0\0 N r- \Q oo—oDATE: 12107107 00 V7 0 � SCALE: AS NOTED * � DWG. BY: EAG = OF Q� � CHK. eY:S. SAFFELI IDP.� • �� �� DRAWING NO.: No D015024 B LV[i� 29578 I SHEET 1 OF 5 0 w iv m 3/4' MIN. EDGE DIST. \ 2 1 SEE DETAIL A ON SHEET 5 Q < 00Q0Q I � I 0 0 I � I r 2 00 w = w = = W = O w m w = w � W w w Q w Q Of (i_ LL- w Q . Q Q X Q 00 00 V)0000 N000U-) 00 rn r- 00 rn 0 w N m \ m w 3/4" MIN. EDGE DIST. trol 26 iY O w 1-- x LLJ 7 31 32 3 18 16 aO 0 I I �o 00 0' O_ CD CD 0_' W W F Z J J w w a a_ 16 19 0 co 00 0) m \ w z Q Y SEE DETAIL A ON SHEET 5 2 1/2" MIN. EDGE DIST. D' O Of L� W H X W 0 w CO 24 �w �z as e } 4 2 1/2" MIN. EDGE DIST. Q Q OOaOQ 100 I f I 00 (I _ 00 _ 2 0 F-- Ld = w = mw=O w = w = Of � Of W w Q w Q 0_ 0_ w w Q Q Q X a 00 00 �00ro NLn00� 00 rn 00 26 E ao o I I �o 00 0_ O_ 0 C5 D_ W W F Z J J w w a- a 16 19 O co 00 0) WOOD FRAME INSTALLATION SCALE.- 3" =>'—O" CONCRETE INSTALLATION SCALE- 3" =>'—O" ITEM DESCRIPTION MATERIAL 1 LATCH JAMB 1 1 4" x 4 9 16" PONDEROSA FINGER JOINTED PINE PINE 2 HINGE JAMB 1 1 4" x 4 9 16" PONEROSA FINGER JOINTED PINE PINE 3 HEAD JAMB 1 1 4" x 4 6 16" PONDERSOA FINGER JOINTED PINE PINE 4 4" x 4" BUTT HINGE 12 a..097" HAGER STEEL 5 #9 X 1" PFH WOOD SCREW HINGE TO DOOR) qTFFI 6 1#9 x 3/4" PFH WOOD SCREW HINGE TO DOOR STEEL 7 #8 PFH WOOD SCREW WITH 1.50 MIN. EMB. INTO SUB -BUCK STEEL 8 10 x 2" PFH WOOD SCREW STEEL 9 3 16" ITW TAPCON MIN. EMBEDMENT 1 1 4" INTO MASONRY STEEL 10 ADA EXT. ALUMINUM THRESHOLD MODEL 6063-T5 ALUM. 11 INSWING ADJUSTABLE THRESHOLD 1.25" x 4.56" ALUM. 12 INOT USED - 13 COMPRESSION WEATHERSTRIP SCHLEGEL Q-LON QDS 650 FOAM 14 #12 x 3" PFH WOOD SCREW STEEL 15 #9 x 1" PFH WOOD SCREW STEEL 16 FACE SHEET 24GA. .020" THK. MIN. GALVANIZED STEEL STEEL 17 #8 x 2" PFH WOOD SCREW STEEL 18 TOP RAIL 1.73" x 1.21 " x 0.021 " THK STEEL 19 BOTTOM RAIL 1.73" x 1.21 " x 0.021 " THK STEEL 20 SIDE STILES 1.73" x 1.21" x 0.021" THK STEEL 21 WOOD LOCK BLOCK 1.67" x 3.0" x 18.75" WOOD 22 STRIKE PLATE - 23 MDF BOARD MDF 24 0.50" x 1.69" DOOR BOTTOM SWEEP VINYL 25 IWOOD LOCK BLOCK WOOD 26 IDOOR CORE BY JELD-WEN FOAM 27 KWIKSET TITAN SERIES LATCH & DEADBOLT 200 & 660 - 28 KWIKSET TITAN SERIES LATCH & DEADBOLT 700 - 29 LATCH SCREWS #8 x 1 1/2" PFH WOOD SCREW STEEL 30 NOT USED - 31 2X WOOD BUCK WOOD 32 1 4" MAX. COMPRESSION SHIM WOOD 33 16 GA. 7 16" CROWN x 2" LONG STAPLES I STEEL 16 26 O O W � 19 x '�' w ~ Z 10 24 O O rn m0 Lo M z w `� co W Y co C)NZLo WNW= � co Y YO ZO O U Q wcr- nw ALL _I O Lu U O W00 C) : JJ �ci �3� N Um J O Q ~ 00 OfW 0 1 O O (o Of 0 af o N I Q 3- Y m a E ¢ c m Ell 22 �o ME O U Z Z C O W o O � CCD _!t W N W V ! W z i °. o w rLnNrr- �����o �,, w �m 9 �w 2 1/2" MIN. EDGE DIST. ro0(on0) 00 N 00 N — 00 — N — r- �TICAL CROSS SECTION TYP. — OPT I 11lIIl/ '' i 0 0 0 0 CONCRETE INSTALLATIOAVALE.• 3'`� ��� ^ M icl o .. •� -- : DATE: 12/07/07 * : N _ . 7 � O SCALE: AS NOTED DWG. BY: EAG -p * S A �oO OF � Z CHK. BY:S. SAFFELL DRAWING NO.: i - O IDP.•• !�� �� I A E. NO. 7 S� .�� q B L S ` DO 15024 SHEET 2 OF 5 .0�JJA I FL 33pQq� FBPE Certific6tk/c�iVVjr j plren' No. 29578 37 3/4" MAX. FRAME WIDTH 36" MAX PANEL WIDTH 22 4 20� 21 25 261NTERIOR �\�\ 13 EXTERIOR OEN SHEET 51 3/4" MIN. EDGE 1 27 1 /4" MAX. SHIM SPACE 3/4" MIN. EDGE DISTANCE DISTANCE 1 1 /2" MIN. EMB. 1 1 /2" MIN. EMB. A HORIZONTAL CROSS SECTION TYP. 3 WOOD INSTALLATION SCALE.- 3" =>'—O" 37 3/4" MAX. FRAME WIDTH 36" MAX PANEL WIDTH 22 20� 21 25 26 INTERIOR 27 20 v 16 / . 2 1 /2" MIN. ��SEE DETAIL A 16 26 13 EDGE DIST. a ON SHEET 5 EXTERIOR r7 1 1 2 1 /4" MAX. SHIM SPACE MIN. EMB. CONCRETE INSTALLATION SCALE- 3" =>'—O" 2 1 /2" MIN EDGE DIST. 1 1 1 /4" MIN. EMB. T J � m Z p —' M z LU `� 00 W Y co C)NLO WNJ= , c) > O Q z cn � � z o z U Ld Owl Z -� Z_U �OL 36" MAX. PANEL WIDTH Lu m I j W 00 Q cm cm ®® ®® zc~n�3QN o 00 00 1311 00 00 ®®qj Oc) 0 I (10 o 0 C6 w w Q 00 00 00 ®® O1 a a CL CL ®® �N:��ma Y E 00 13 U 0 E an ® ® ® ® ®BOB ®®® Q w W o C1] Q o =o�� O 1252 = W OW Q M M an 00 Z U C.D00 (I W O ~¢ W a Leo 00 � 0 00P 0o � i0 n CO Ln 't rM N 161 •� �,� S` -- : DATE: 12/07/07 * N 7 I : SCALE: AS NOTED DWG. BY: EAG -0 * S A 1 �O OF ;: Q� Z � CHK. EMS. SAFFELL DRAWING NO.: i - O IDP.•• !�� I� I A E. NO. 7 S� . DO 15024 SHEET 3 OF 5 B��NJJJA ! FL 33pQq� FBPE Certific6tk/clty tjYpiicn'No. 29578 i 4" 18.5" O.C. 00 00 00 I CV � I SEE D DETAIL A SCALE: 318" =I'—O" SEE DETAIL D i 00 0 Ln I r� 00 I 0 ANCHORING LOCATIONS 6'8" INSWING SINGLE UNIT (X) SCALE: I/2" =I'—O" DETAIL B SCALE: 318" =I'—O" SEE DETAIL A L 6'$ 1'-0 37116" . 1'-0 3716" 4'5 1'-0 '3716" 1'-0 371 ' 1'-0 3716' B 1'-0 1'-0 3716" ALL DOOR MODELS ARE VIEWED FROM THE EXTERIOR SIDE 6'�-I I— � 6" I SEE DETAIL B 6'�{ Tp- SEE DETAIL D 8 2' 2' V7 9 TYP. D c 6" SEE DETAIL C ANCHORING LOCATIONS 8'0" INSWING SINGLE UNIT (X) SCALE.- I/2" =I'-0" DETAIL C DETAIL D SCALE: 3" =I'—O" SCALE: 3" =I'—O" ■11ar_lIM T T�T vJ J � m � Z p —' M z w `� 00 W Y o0 C) LO W co , c) � z J z � LU � J Q p n LU z o �� I W W00pm O cn vNi U J O a z U c Q D I O O Of w Q 0 CL gU m a EQ�� a o W o = C� a o �o Or m O U Z Z O W C o O C-D C.D '_!t C.7Fs a w ':I�,I�,-IInI'IN 00 � o 00P 1Oo � io n CO L(� 't rM N 161 •� �,� S` -- : DATE: 12/07/07 * N 7 7 _ SCALE: AS NOTED DWG. BY: EAG -0 * S A 1 �O OF ;: Q CHK. EMS. SAFFELL DRAWING NO.: i - O IDP.•• !�� �� I A E. NO. 7 S� .�� q B L `S DO 15024 SHEET 4 OF 5 M�eJJA ! FL 339N� FBPE Certific6tk/c� t�tj iion'No. 29578 T 0.585" 1.083" 2 3/ 16" f 9/16" 13 COMPRESSION WEATHERSTRIP SCALE- 6" =>'—O" 4 24 VINYL BOTTOM DOOR SWEEP SCALE.- 6" =>'—O" (Min) 4 BUTT HINGE 4x4x>2 C.A. SCALE.- 6" =>'-O" 1 3/4" 1 1 /4" i DOOR TOP RAIL & SIDE STILE 021" MIN. GALV. STEEL SCALE- 6" =>'-O" 4" �2 1/4"� 1 /2" 9 ,O ADA ALUMINUM THRESHOLD SCALE- 6" =9'—O" 18 3/4" for 8'-0" DOOR 11 3/4" FOR 6'-8" DOOR 1 /4" 3L JL c /0 HARDWARE USED �@SCALE- LOCK BLOCK 3" =>'—O" r1 3/4" —{ :n-jj 1 3/16" 19 BOTTOM RAIL SCALE. 6" =>'—O" 1 23/32" 3/ 16 9/16" „ INSWING THRESHOLD SCALE: 6" =P—O" 23 MDF BOARD SCALE.• 6" =>'—O" T T�T vJ J � m � co Z p;'M z LU `� ab W C) LO Lu uj W co 00 I i m W N a Of 0 a a- Z, n I lY a 0 �s8-oa� � Or m Z U \ WU' CW9 \ O �W Fs O W G d DETAIL A SCALE- 114" =>'-O" Ln1'�! lfill1 00 0 � 0 00 0-0 N � i--i ```xill n (O LO - rM N •� �,� S` -- : DATE: 12/07/07 � * : N . 7 I � _SCALE: AS NOTED DWG. BY: EAG -p * S A �O OF �: � Z CHK. EMS. SAFFE DRAWING NO.: i - O IDP.•• !�� �� I� I A E. NO. 7 S� . DO 15024 SHEET 5 OF 5 B��NJJJA ! FL 33pQq� FBPE Certific6tk/clty tj pii No. 29578