Loading...
HomeMy WebLinkAboutEVANS- ENERGY CALC (1)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 511/13/2020 12:58 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY KEITH EVANS Street: City, State, Zip: FORT PIERCE , FL , 3003 AVENUE T Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 988 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=1.05 92.00 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 988.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1072.00 ft² b. N/A R=f t ² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 988.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU/WH CLST 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.333 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (92.0 sqft.) (1072.0 sqft.) (988.0 sqft.) (988.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 23.6 SEER:16.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 130 EF: 0.980 Glass/Floor Area: 0.093 Total Proposed Modified Loads: Total Baseline Loads: 37.61 41.15 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 11-16-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY 1 KEITH EVANS Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 988 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie 3003 AVENUE T Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 988 7904 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 BEDROOM 2 116 928 No 0 1 Yes Yes1 Yes 2 CLST 2 14 112 No 0 Yes Yes1 Yes 3 MASTER BEDROO 156 1248 No 0 1 Yes Yes1 Yes 4 BEDROOM 3 130 1040 No 0 1 Yes Yes1 Yes 5 M CLST 14 112 No 0 Yes Yes1 No 6 M BATH 42 336 No 0 Yes Yes1 Yes 7 LAUNDRY 64 512 No 0 Yes Yes1 Yes 8 BATH 2 32 256 No 0 Yes Yes1 No 9 AHU/WH CLST 12 96 No 0 Yes Yes1 No 10 HALL 39 312 No 0 Yes Yes1 No 11 LIVING RM 185 1480 No 0 Yes Yes1 Yes 12 KITCHEN 184 1472 Yes 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 116 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -021 ft BEDROOM 2 2 14 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2 3 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft MASTER BEDRO 4 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft BEDROOM 3 5 14 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M CLST 11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 6 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M BATH 7 64 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft LAUNDRY 8 32 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft BATH 2 9 12 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft AHU/WH CLST 10 39 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 11 185 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -028 ft LIVING RM 12 184 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031 ft KITCHEN # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 1041 ft² Medium 0.3 0 18.4______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 988 ft² N N150 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 116 ft² 0.1 Wood______BEDROOM 2 Blown 2 Under Attic (Vented)30 14 ft² 0.1 Wood______CLST 2 Blown 3 Under Attic (Vented)30 156 ft² 0.1 Wood______MASTER BEDRO Blown 4 Under Attic (Vented)30 130 ft² 0.1 Wood______BEDROOM 3 Blown 5 Under Attic (Vented)30 14 ft² 0.1 Wood______M CLST Blown 6 Under Attic (Vented)30 42 ft² 0.1 Wood______M BATH Blown 7 Under Attic (Vented)30 64 ft² 0.1 Wood______LAUNDRY Blown 8 Under Attic (Vented)30 32 ft² 0.1 Wood______BATH 2 Blown 9 Under Attic (Vented)30 12 ft² 0.1 Wood______AHU/WH CLST Blown 10 Under Attic (Vented)30 39 ft² 0.1 Wood______HALL Blown 11 Under Attic (Vented)30 185 ft² 0.1 Wood______LIVING RM Blown 12 Under Attic (Vented)30 184 ft² 0.1 Wood______KITCHEN Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0BEDROOM 2 00010 8E Concrete Block - Int Insul 0.30Exterior80.0 ft² ____ 2 4.1 0BEDROOM 2 00011 8S Concrete Block - Int Insul 0.30Exterior88.0 ft² ____ 3 4.1 0CLST 2 0002 8S Concrete Block - Int Insul 0.30Exterior16.0 ft² ____ 4 4.1 0MASTER BE 00012 8S Concrete Block - Int Insul 0.30Exterior96.0 ft² ____ 11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 5 4.1 0MASTER BE 00013 8W Concrete Block - Int Insul 0.30Exterior104.0 ft² ____ 6 4.1 0BEDROOM 3 00013 8E Concrete Block - Int Insul 0.30Exterior104.0 ft² ____ 7 4.1 0M BATH 0006 8W Concrete Block - Int Insul 0.30Exterior48.0 ft² ____ 8 4.1 0LAUNDRY0008 8W Concrete Block - Int Insul 0.30Exterior64.0 ft² ____ 9 4.1 0LIVING RM 00013 8N Concrete Block - Int Insul 0.30Exterior104.0 ft² ____ 10 4.1 0LIVING RM 00015 8E Concrete Block - Int Insul 0.30Exterior120.0 ft² ____ 11 4.1 0KITCHEN00012 8N Concrete Block - Int Insul 0.30Exterior96.0 ft² ____ 12 4.1 0KITCHEN0004 8E Concrete Block - Int Insul 0.30Exterior32.0 ft² ____ 13 4.1 0KITCHEN00015 8W Concrete Block - Int Insul 0.30Exterior120.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .23 20 ft² None______N LIVING RM 863 2 Insulated .23 20 ft² None______W KITCHEN 863 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 E Low-E Single 1.05 0.25 12.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes1 Y 2 W Low-E Single 1.05 0.25 16.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes5 Y 3 E Low-E Single 1.05 0.25 12.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes6 Y 4 W Low-E Single 1.05 0.25 9.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes8 Y 5 N Low-E Single 1.05 0.25 16.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes9 Y 6 E Low-E Single 1.05 0.25 18.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes10 Y 7 W Low-E Single 1.05 0.25 9.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes13 Y Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 922.1 750.62.000356Wholehouse .123395.21Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 17 kBtu/hr ______sys#1None1 11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 23.6 kBtu/hr 708 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None AHU/W H CLST FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 130 ft² Attic 13 ft² Default Leakage AHU/W H C (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 M CLST Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 AHU/WH CLST Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING RM Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN 11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������