HomeMy WebLinkAboutEVANS- ENERGY CALC (1)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 511/13/2020 12:58 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
KEITH EVANS
Street:
City, State, Zip: FORT PIERCE , FL ,
3003 AVENUE T
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
988
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=1.05 92.00 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 988.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1072.00 ft²
b. N/A R=f t ²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 988.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU/WH CLST
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.333 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(92.0 sqft.)
(1072.0 sqft.)
(988.0 sqft.)
(988.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
23.6 SEER:16.00
Efficiency
k B t u / h r Efficiency
17.0 COP:1.00
f t ² R
6 130
EF: 0.980
Glass/Floor Area: 0.093
Total Proposed Modified Loads:
Total Baseline Loads:
37.61
41.15 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
11-16-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
KEITH EVANS
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
988
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
3003 AVENUE T
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 988 7904
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 BEDROOM 2 116 928 No 0 1 Yes Yes1 Yes
2 CLST 2 14 112 No 0 Yes Yes1 Yes
3 MASTER BEDROO 156 1248 No 0 1 Yes Yes1 Yes
4 BEDROOM 3 130 1040 No 0 1 Yes Yes1 Yes
5 M CLST 14 112 No 0 Yes Yes1 No
6 M BATH 42 336 No 0 Yes Yes1 Yes
7 LAUNDRY 64 512 No 0 Yes Yes1 Yes
8 BATH 2 32 256 No 0 Yes Yes1 No
9 AHU/WH CLST 12 96 No 0 Yes Yes1 No
10 HALL 39 312 No 0 Yes Yes1 No
11 LIVING RM 185 1480 No 0 Yes Yes1 Yes
12 KITCHEN 184 1472 Yes 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 116 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -021 ft BEDROOM 2
2 14 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2
3 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft MASTER BEDRO
4 130 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft BEDROOM 3
5 14 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M CLST
11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
6 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M BATH
7 64 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft LAUNDRY
8 32 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft BATH 2
9 12 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft AHU/WH CLST
10 39 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
11 185 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -028 ft LIVING RM
12 184 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -031 ft KITCHEN
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 1041 ft² Medium 0.3 0 18.4______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 988 ft² N N150
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)30 116 ft² 0.1 Wood______BEDROOM 2 Blown
2 Under Attic (Vented)30 14 ft² 0.1 Wood______CLST 2 Blown
3 Under Attic (Vented)30 156 ft² 0.1 Wood______MASTER BEDRO Blown
4 Under Attic (Vented)30 130 ft² 0.1 Wood______BEDROOM 3 Blown
5 Under Attic (Vented)30 14 ft² 0.1 Wood______M CLST Blown
6 Under Attic (Vented)30 42 ft² 0.1 Wood______M BATH Blown
7 Under Attic (Vented)30 64 ft² 0.1 Wood______LAUNDRY Blown
8 Under Attic (Vented)30 32 ft² 0.1 Wood______BATH 2 Blown
9 Under Attic (Vented)30 12 ft² 0.1 Wood______AHU/WH CLST Blown
10 Under Attic (Vented)30 39 ft² 0.1 Wood______HALL Blown
11 Under Attic (Vented)30 185 ft² 0.1 Wood______LIVING RM Blown
12 Under Attic (Vented)30 184 ft² 0.1 Wood______KITCHEN Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0BEDROOM 2 00010 8E Concrete Block - Int Insul 0.30Exterior80.0 ft² ____
2 4.1 0BEDROOM 2 00011 8S Concrete Block - Int Insul 0.30Exterior88.0 ft² ____
3 4.1 0CLST 2 0002 8S Concrete Block - Int Insul 0.30Exterior16.0 ft² ____
4 4.1 0MASTER BE 00012 8S Concrete Block - Int Insul 0.30Exterior96.0 ft² ____
11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
5 4.1 0MASTER BE 00013 8W Concrete Block - Int Insul 0.30Exterior104.0 ft² ____
6 4.1 0BEDROOM 3 00013 8E Concrete Block - Int Insul 0.30Exterior104.0 ft² ____
7 4.1 0M BATH 0006 8W Concrete Block - Int Insul 0.30Exterior48.0 ft² ____
8 4.1 0LAUNDRY0008 8W Concrete Block - Int Insul 0.30Exterior64.0 ft² ____
9 4.1 0LIVING RM 00013 8N Concrete Block - Int Insul 0.30Exterior104.0 ft² ____
10 4.1 0LIVING RM 00015 8E Concrete Block - Int Insul 0.30Exterior120.0 ft² ____
11 4.1 0KITCHEN00012 8N Concrete Block - Int Insul 0.30Exterior96.0 ft² ____
12 4.1 0KITCHEN0004 8E Concrete Block - Int Insul 0.30Exterior32.0 ft² ____
13 4.1 0KITCHEN00015 8W Concrete Block - Int Insul 0.30Exterior120.0 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .23 20 ft² None______N LIVING RM 863
2 Insulated .23 20 ft² None______W KITCHEN 863
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 E Low-E Single 1.05 0.25 12.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes1 Y
2 W Low-E Single 1.05 0.25 16.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes5 Y
3 E Low-E Single 1.05 0.25 12.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes6 Y
4 W Low-E Single 1.05 0.25 9.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes8 Y
5 N Low-E Single 1.05 0.25 16.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes9 Y
6 E Low-E Single 1.05 0.25 18.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes10 Y
7 W Low-E Single 1.05 0.25 9.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes13 Y
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
922.1 750.62.000356Wholehouse .123395.21Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 17 kBtu/hr ______sys#1None1
11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 23.6 kBtu/hr 708 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None AHU/W H CLST
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 130 ft² Attic 13 ft² Default Leakage AHU/W H C (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 M CLST
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 AHU/WH CLST
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING RM
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
11/13/2020 12:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������