HomeMy WebLinkAboutrevised product approval Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 1 of 22 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 4 1B-1 Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1B-2 Wood New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 7 1E-1 Wood New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 8 1E-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 9 1F Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 9 2A Steel or Conc. New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10 2B Steel or Conc. New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 11 3A Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 12-14 3B Concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 4B LWIC New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-18 5A CWF New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 19 5B CWF New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 19 5C CWF New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 19 6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 20 6B Gypsum Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 21 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 21-22 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:  Wood: Minimum 0.75-inch penetration.  Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.  Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer’s published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically atta ched base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 2 of 22 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions.  Hot asphalt: Full coverage at 25-30 lbs/square.  Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.  Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.  OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.  OlyBond Classic (OB Classic): Full coverage at 1 gal/square.  ICP Adhesives CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.  Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered.  Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:  Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)  OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi-Max FA-3)  OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL)  OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)  OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II, Poly ISO 2)  ICP Adhesives CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 3 of 22 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1: MULE-HIDE ROOF COVERS Reference Layer Material Application SBS-SA (SBS, Self-Adhering) Base Ply One or more plies SA Base Sheet, SA Base Sheet (FR) Self-Adhering Cap SA-SBS Cap Sheet, SA-SBS Cap Sheet (FR) Note: Self-adhering membranes shall not be installed over APP-TA membranes. APP-TA (APP, Torch-Applied) Base Ply or Ply One or more plies APP Torch Base, APP Torch S Torch-Applied Cap APP Torch S, APP Torch G, APP Torch G FR, APP Torch KoolCap G, APP Torch KoolCap G FR APP-SA (APP, Self-Adhering) Cap SA-APP Cap Sheet, SA-APP Cap Sheet (FR), SA-APP KoolCap G, SA-APP KoolCap G (FR) Self-Adhering Note: Self-adhering membranes shall not be installed over APP-TA membranes. 16. Any FBC Approved coating listed for use with SBS or APP modified bitumen roofing may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. 17. Dens Deck shall be field-primed with PG100 prior to self-adhering membrane application. Refer to tables herein for other priming requirements. 18. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A Option # Primer Vapor Barrier Insulation Adhesive MDP (psf) Type Attach VB-1. Mule-Hide 121 SA Base Sheet Self-Adhering Inta-Stik or CR-20, 12-inch o.c. -60.0 VB-2. Mule-Hide 121 APP Torch Base Torch-applied Inta-Stik or CR-20, 12-inch o.c. -75.0 VB-3. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering Insta-Stik, 12-inch o.c. -75.0 VB-4. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5 VB-5. Mule-Hide 121 SA-SBS Cap Sheet Self-Adhering CR-20, 12-inch o.c. -270.0 VB-6. Mule-Hide 121 SA Base Sheet, SA Base Sheet (FR) Self-Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0 19. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 4 of 22 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap W-1 Min. 15/32- inch plywood Min. 1.5-inch ACFoam II, ACFoam III, ENRGY-3, H- Shield, H-Shield CG, Multi-Max FA3 D-IS, M-OSFA, OB500 or CR-20 (Optional) additional layers(s) of base insulation D-IS, M-OSFA, OB500 or CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -52.5 TABLE 1B-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap TORCH-APPLIED BASE PLY: W-2 Min. 19/32- inch plywood Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28, Tamko Glass Base, GAFGLAS #75 32 ga., 1-5/8- inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, Poly ISO 2, ENRGY- 3, H-Shield, Poly ISO 2, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -60.0 W-3 Min. 15/32- inch plywood Polyglass G2 Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, Poly ISO 2, ENRGY- 3, H-Shield, Poly ISO 2, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -82.5 W-4 Min. 15/32- inch plywood Polyglass G2 Base 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in five (5) equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, Poly ISO 2, ENRGY- 3, H-Shield, Poly ISO 2, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -90.0 SELF-ADHERING BASE PLY: W-5 Min. 19/32- inch plywood Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28, Tamko Glass Base, GAFGLAS #75 32 ga., 1-5/8- inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, Poly ISO 2, ENRGY- 3, H-Shield, Poly ISO 2, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -60.0 W-6 Min. 19/32- inch plywood Nail Base 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Min. 2-inch ACFoam II, Poly ISO 2, ACFoam III, H- Shield, Poly ISO 1, H-Shield CG, Multi- Max FA3, ENRGY-3 D-IS, OB500, CR-20, M- OSFA, atop fastener rows, 7-inch o.c. (Optional) Additional layers of base insulation D-IS, OB500, CR-20, M-OSFA SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -60.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 5 of 22 TABLE 1B-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap TORCH-APPLIED BASE PLY: W-7 Min. 19/32- inch plywood Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY-3, H-Shield, Poly ISO 2, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -60.0 W-8 Min. 15/32- inch plywood Polyglass G2 Base Dekfast Hex Plates with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY-3, H-Shield, Poly ISO 1, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -82.5 SELF-ADHERING BASE PLY: W-9 Min. 19/32- inch plywood Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY-3, H-Shield, Poly ISO 2, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 6 of 22 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Ply Cap TORCH-APPLIED BASE PLY: W-10 Min. 15/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast Hex Plates with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast HD. 1 per 2 ft2 APP-TA (Optional) APP-TA APP-TA -30.0 SELF-ADHERING BASE PLY: W-11 Min. 15/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast Hex Plates with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast HD. 1 per 2 ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -30.0 W-12 Min. 19/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ENRGY 3, H- Shield, Poly ISO 1, Polytherm Dekfast Galvalume Steel Hex with Dekfast #12 DP or Mule-Hide 3” Insulation Plate with Mule-Hide Drill Point Fastener 1 per 1.33 ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -82.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 7 of 22 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Base Fasten Attach Base Ply Cap TORCH-APPLIED BASE PLY: W-13 Min. 19/32- inch plywood One or more layers, any combination Prelim. Attached Nail Base, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28, Tamko Glass Base or GAFGLAS #75 OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast HD 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5 W-14 Min. 19/32- inch plywood One or more layers, any combination Prelim. Attached Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0 W-15 Min. 15/32- inch plywood One or more layers, any combination Prelim. Attached Polyglass G2 Base, Nail Base Dekfast Hex Plates with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast HD. 10-inch o.c. in 4-inch lap and 10- inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -75.0 W-16 Min. 15/32- inch plywood One or more layers, any combination Prelim. Attached Polyglass G2 Base, Nail Base Dekfast Hex Plates with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast HD. 9-inch o.c. in 4-inch lap and 9- inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0 SELF-ADHERING BASE PLY: W-17 Min. 19/32- inch plywood One or more layers, any combination Prelim. Attached Nail Base Dekfast Hex with Dekfast #14 or Mule-Hide 3” Insulation Plate with Mule-Hide HDP Fastener 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, APP-TA -52.5* W-18 Min. 19/32- inch plywood One or more layers, any combination Prelim. Attached Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, APP-TA -60.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 8 of 22 TABLE 1E-1: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap TORCH-APPLIED BASE PLY: W-19 Min. 15/32- inch plywood Nail Base Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0* W-20 Min. 15/32- inch plywood Nail Base Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5 W-21 Min. 15/32- inch plywood APP Torch Base, Nail Base Original Simplex Cap Nails (1-inch metal head diameter, 11 gauge x min. 1.25-inch long annular grooved shank) 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5 W-22 Min. 19/32- inch plywood Nail Base, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28, Tamko Glass Base or GAFGLAS #75 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0 W-23 Min. 15/32- inch plywood Polyglass G2 Base, Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP-TA APP-TA -67.5 W-24 Min. 15/32- inch plywood Polyglass G2 Base, Nail Base Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -75.0 W-25 Min. 15/32- inch plywood Polyglass G2 Base, Nail Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0 W-26 Min. 15/32- inch plywood Nail Base Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0 W-27 Min. 15/32- inch plywood Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -105.0 W-28 Min. 19/32- inch plywood Elastobase or Elastobase Poly 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP-TA APP-TA -112.5 SELF-ADHERING BASE PLY: W-29 Min. 15/32- inch plywood Nail Base Original Simplex Cap Nails (1-inch metal head diameter, 11 gauge x min. 1.25-inch long annular grooved shank) 6-inch o.c. at 3-inch lap and 6-inch o.c. in four, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP- SA, APP-TA -52.5 W-30 Min. 19/32- inch plywood Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP- SA, APP-TA -60.0 W-31 Min. 19/32- inch plywood Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP- SA, APP-TA -97.5 W-32 Min. 19/32- inch plywood Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. Note: Tin caps are to be primed with Mule-Hide 121 or ASTM D41 primer. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, APP- SA, APP-TA -112.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 9 of 22 TABLE 1E-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap TORCH-APPLIED BASE PLY: W-33 Min. 19/32- inch plywood Nail Base, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28, Tamko Glass Base or GAFGLAS #75 OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast HD 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5 W-34 Min. 19/32- inch plywood Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0 W-35 Min. 15/32- inch plywood Polyglass G2 Base, Nail Base Dekfast Hex Plates with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast HD. 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -75.0 W-36 Min. 15/32- inch plywood Polyglass G2 Base, Nail Base Dekfast Hex Plates with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0 W-37 Min. 15/32- inch plywood APP Torch Base or Nail Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty (min. 1-5/8-inch long) with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0 W-38 Min. 15/32- inch plywood APP Torch Base or Nail Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty (min. 1-5/8-inch long) with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows (Optional) APP-TA APP-TA -120.0 SELF-ADHERING BASE PLY: W-39 Min. 19/32- inch plywood Nail Base Dekfast Hex with Dekfast #14 or Mule-Hide 3” Insulation Plate with Mule-Hide HDP Fastener 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, APP-TA -52.5* W-40 Min. 19/32- inch plywood Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, APP-TA -60.0* TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment Base Ply Ply Cap W-41 Min. 15/32- inch plywood (Optional) Mule-Hide 121 None SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP- TA -90.0 W-42 Min. 15/32- inch plywood (Optional) Mule-Hide 121 Plywood joints are covered with minimum 4-inch wide strips of SA Base Sheet, rolled into place to create continuous bond. SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP- TA -135.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 10 of 22 TABLE 2A: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten Attach Base Ply Ply Cap SC-1. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1 Dekfast Galvalume Steel Hex with Dekfast #12 DP (steel only) or Dekfast #14, OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 2.67 ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -30.0 SC-2. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch H-Shield, Poly ISO 1, Polytherm OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 2 ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -45.0* SC-3. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch H-Shield, Poly ISO 1, Polytherm Dekfast Galvalume Steel Hex with Dekfast #12 DP (steel only) or Dekfast #14 1 per 2 ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -60.0 SC-4. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ENRGY 3, H-Shield, Poly ISO 1, Polytherm Dekfast Galvalume Steel Hex with Dekfast #12 (steel only) or #14 or Mule-Hide 3” Insulation Plate with Mule-Hide Drill Point Fastener (steel only) or Mule-Hide HDP Fastener 1 per 1.33 ft2 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -82.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 11 of 22 TABLE 2B: STEEL OR CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS System No. Deck (Note 1) Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Base Fasten Attach Base Ply Cap SC-5. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached Nail Base or JM Perma-Ply 28 OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast HD 12-inch o.c. in 4-inch lap and 18- inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0* SC-6. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached Nail Base, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28, Tamko Glass Base or GAFGLAS #75 OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast HD 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -52.5 SC-7. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached Nail Base OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex with Dekfast #14 or Mule-Hide 3” Insulation Plate with Mule-Hide HDP Fastener 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA -52.5* SC-8. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 (steel only) or #14 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0 SC-9. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached Nail Base OMG Flat Bottom Plates (square) with Roofgrip #12 (steel only) or #14 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA -60.0* SC-10. Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached APP Torch S Dekfast isofast IF-2.375-AT Plates with Dekfast #15 HS 12-inch o.c. withiin the 5-inch wide, heat-welded side lap (Optional) APP-TA APP-TA -82.5 SC-11. Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached APP Torch S Trufast 2.4 in. Barbed Seam Plates with Trufast EHD Fasteners 12-inch o.c. within the 6-inch wide, heat-welded side lap (Optional) APP-TA APP-TA -82.5 SC-12. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Prelim. Attached APP Torch S Dekfast Hex with Dekfast #14 or OMG Flat Bottom Plates with OMG Roofgrip #14 12-inch o.c. within the 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -112.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 12 of 22 TABLE 3A: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap SELF-ADHERING BASE PLY WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: C-1 Concrete (Optional) Mule-Hide 121 Min. 1.5-inch H-Shield, Poly ISO 1, Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -67.5 C-2 Concrete (Optional) Mule-Hide 121 Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -135.0 C-3 Concrete None Min. 1.5-inch, min. 1.5 pcf EPS insulation board D-IS (Optional) additional layers of base insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -157.5 C-4 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS insulation board OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0 C-5 Concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -127.5 C-6 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -150.0 C-7 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-Shield, Poly ISO 1, Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -232.5 C-8 Concrete None Min. 1.5-inch, min. 2.0 pcf EPS insulation board CR-20 (Optional) additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0 C-9 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG , Multi-Max FA3, ISO 95+ GL CR-20 (Optional) additional layers(s) of base insulation CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -270.0 C-10 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1 OB Classic (Optional) additional layers(s) of base insulation OB Classic SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -270.0 C-11 Concrete Mule-Hide 121 Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 Hot asphalt (Optional) additional layers(s) of base insulation Hot asphalt SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -480.0 SELF-ADHERING BASE PLY WITH BASE INSULATION AND COVERBOARD: C-12 Concrete None Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -67.5 C-13 Concrete None Min. 1.5-inch, min. 2.0 pcf ASTM C578 Expanded Polystyrene, ACFoam II, Poly ISO 2, ENRGY 3 , H-Shield, Poly ISO 1 D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-14 Concrete None Min. 1.5-inch, min. 2.0 pcf ASTM C578 Expanded Polystyrene D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime D-IS SBS-SA (Optional) APP-TA APP-TA -120.0 C-15 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H- Shield, Poly ISO 1 D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -247.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 13 of 22 TABLE 3A: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap C-16 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-Shield, Poly ISO 1 or ISO 95+GL OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-17 Concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA (Optional) APP-TA APP-TA -127.5 C-18 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1, ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA (Optional) APP-TA APP-TA -150.0 C-19 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H- Shield, Poly ISO 1 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -247.5 C-20 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-Shield, Poly ISO 1, Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -72.5 C-21 Concrete None Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-Shield, Poly ISO 1, Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -232.5 C-22 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H- Shield, Poly ISO 1 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -247.5 C-23 Concrete None Min. 1.5-inch, min. 2.0 pcf ASTM C578 Expanded Polystyrene CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-24 Concrete None Min. 1.5-inch, min. 2.0 pcf ASTM C578 Expanded Polystyrene CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime CR-20 SBS-SA (Optional) APP-TA APP-TA -240.0 C-25 Concrete None Min. 1.5-inch Ultra-Max, Multi-Max FA-3, min. 1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL, H-Shield, Poly ISO 1, H-Shield CG, ENRGY 3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -240.0 C-26 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3, H- Shield, Poly ISO 1 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -247.5 C-27 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1 OB Classic Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB Classic SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -350.0 C-28 Concrete Mule-Hide 121 Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -350.0 TORCH APPLIED BASE PLY: C-29 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1 D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -232.5 C-30 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 APP-TA (Optional) APP-TA APP-TA -232.5 C-31 Concrete None Min. 2-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA APP-TA (Optional) APP-TA APP-TA -232.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 14 of 22 TABLE 3A: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap C-32 Concrete None Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL, H-Shield, Poly ISO 1, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5 C-33 Concrete None (Optional) Min. 2-inch ACFoam II, Poly ISO 2, H- Shield, Poly ISO 1 OB Classic Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB Classic APP-TA (Optional) APP-TA APP-TA -232.5 C-34 Concrete Mule-Hide 121 Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -232.5 TABLE 3B: CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap C-35 Concrete Mule-Hide 121 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -315.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 15 of 22 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Struct. Deck LWC Type Attach Type Attach Base Ply Ply Cap SELF-ADHERING BASE PLY WITH BASE INSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE: LWC-1 Concrete Min. 200 psi, min 2-inch Elastizell Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene OB500 (Optional) Additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0 LWC-2 Concrete Min. 200 psi, min 2-inch Elastizell Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1 OB500 (Optional) Additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -225.0 LWC-3 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -180.0 LWC-4 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -180.0 LWC-5 Concrete Min. 200 psi, min. 2-inch Celcore or Mearlcrete Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -222.5 LWC-6 Concrete Min. 200 psi, min. 2-inch Celcore or Mearlcrete Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -222.5 SELF-ADHERING BASE PLY WITH BASE INSULATION AND COVERBOARD: LWC-7 Concrete Min. 200 psi, min 2-inch Elastizell Min. 1.5-inch, min. 2.0 pcf ASTM C578 expanded polystyrene OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -120.0 LWC-8 Concrete Min. 200 psi, min 2-inch Elastizell Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -225.0 LWC-9 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 or min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -180.0 LWC-10 Concrete Min. 200 psi, min. 2-inch Celcore or Mearlcrete Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 or min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP- TA SBS-SA, APP-SA, APP-TA -222.5 TORCH APPLIED BASE PLY: LWC-11 Concrete Min. 200 psi, min 2-inch Elastizell Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -225.0 LWC-12 Concrete Min. 200 psi, min. 2-inch Elastizell Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 or min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA, SBS- AA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -180.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 16 of 22 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Struct. Deck LWC Type Attach Type Attach Base Ply Ply Cap LWC-13 Concrete Min. 200 psi, min. 2-inch Celcore or Mearlcrete Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, ISO 95+ GL, H-Shield, Poly ISO 1, H-Shield CG, Multi-Max FA3 or min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA, SBS- AA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -222.5 TABLE 4B: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Struct LWC Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap LWC-14 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi Approved cellular LWC GAFGLAS #75 OMG CR BSF 7-inch o.c. at 4-inch lap and 7-inch o.c. in two, equally spaced center rows Min. 1.5-inch ACFoam II, Poly ISO 2, H-Shield, Poly ISO 1, Multi-Max FA3, Polytherm Hot asphalt None N/A SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 17 of 22 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Structural Deck Lightweight Concrete Type Fasten Attach Base Ply Cap CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: LWC-15 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF Polyglass G2 Base, Nail Base Trufast Twin Loc-Nail 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, equally spaced, staggered rows in the field of the sheet (Optional) APP-TA APP-TA -45.0 LWC-16 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF Nail Base Trufast Twin Loc-Nail 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP-SA, APP-TA -45.0 LWC-17 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Nail Base Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows (Optional) APP-TA APP-TA -60.0 LWC-18 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Nail Base Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, APP-TA -60.0 LWC-19 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore Polyglass G2 Base, Nail Base, GAFGLAS #75, GAFGLAS Stratavent Nailable Venting Base Sheet, GAFGLAS Ply 4, GAFGLAS FlexPly 6, JM Perma Ply No. 28, JM Vensulation, JM GlasPly IV. GlasPly Premier. Tamko Glass-Base, Tamko Vapor-Chan Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet APP-TA APP-TA -75.0 LWC-20 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Nail Base Trufast FM-290 10-inch o.c. in a 4-inch lap and 10-inch o.c. in three equally spaced, staggered center rows (Optional) APP-TA APP-TA -90.0 ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE: LWC-21 Min. 0.0179-inch Tensilform S-75 or min. 0.0205-inch Tensilform 75 at max. 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II Polyglass G2 Base, Nail Base, GAFGLAS #75, GAFGLAS Stratavent Nailable Venting Base Sheet, GAFGLAS Ply 4, GAFGLAS FlexPly 6, JM Perma Ply No. 28, JM Vensulation, JM GlasPly IV. GlasPly Premier. Tamko Glass-Base, Tamko Vapor-Chan Trufast FM-90 or OMG CR BPF 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. in two, equally spaced, staggered rows in the field of the sheet APP-TA APP-TA -30.0 LWC-22 Min. 0.0179-inch Tensilform S-75 or min. 0.0205-inch Tensilform 75 at max. 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II Nail Base Trufast FM-90 or OMG CR BPF 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP-SA, APP-TA -30.0 LWC-23 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II Polyglass G2 Base, Nail Base, GAFGLAS #75, GAFGLAS Stratavent Nailable Venting Base Sheet, GAFGLAS Ply 4, GAFGLAS FlexPly 6, JM Perma Ply No. 28, JM Vensulation, JM GlasPly IV. GlasPly Premier. Tamko Glass-Base, Tamko Vapor-Chan Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet APP-TA APP-TA -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 18 of 22 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Structural Deck Lightweight Concrete Type Fasten Attach Base Ply Cap LWC-24 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II Nail Base Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP-SA, APP-TA -45.0 LWC-25 Min. 22 ga., type B vented steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 Nail Base Trufast FM-290 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three, equally spaced, staggered rows in the field of the sheet (Optional) APP-TA APP-TA -52.5 LWC-26 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 Nail Base Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet APP-TA APP-TA -60.0 LWC-27 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 Nail Base Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP-SA, APP-TA -60.0 MEARLCRETE CELLULAR LIGHTWEIGHT INSULATING CONCRETE: LWC-28 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete Polyglass G2 Base, Nail Base, Tamko Vapor Chan Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet APP-TA APP-TA -45.0 LWC-29 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete Nail Base Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP-SA, APP-TA -45.0 LWC-30 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete Polyglass G2 Base, Nail Base, GAFGLAS #75, JM Perma Ply No. 28, Tamko Glass-Base Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA, or APP-TA SBS-AA, SBS-TA, or APP-TA -52.5 LWC-31 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete Nail Base Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP-SA, APP-TA -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 19 of 22 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap CWF-1 Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch ACFoam II, Poly ISO 2, ISO 95+GL, H-Shield, Poly ISO 1, Polytherm, ENRGY-3 D-IS or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 SBS-SA, APP-TA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -45.0 CWF-2 Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch ACFoam II, Poly ISO 2, ISO 95+GL, H-Shield, Poly ISO 1, Polytherm, ENRGY-3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA, APP-TA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -52.5 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap CWF-3 Min. 2.5-inch Tectum Plank or Tectum LS Plank Nail Base, Polyglass G2 Base Trufast Inuldek Loc-Nail 9-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ISO95+GL, H-Shield, Poly ISO 1, ENRGY 3, Polytherm or Multi- Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA, APP-TA (Optional) SBS- SA, APP-TA SBS-SA, APP-SA, APP-TA -30.0* CWF-4 Min. 2.5-inch Tectum Plank or Tectum LS Plank Nail Base, Polyglass G2 Base Trufast Twin Loc- Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ISO95+GL, H-Shield, Poly ISO 1, ENRGY 3, Polytherm or Multi- Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA, APP-TA (Optional) SBS- SA, APP-TA SBS-SA, APP-SA, APP-TA -45.0* TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap CWF-5 Min. 2.5-inch Tectum Plank or Tectum LS Plank Nail Base, Polyglass G2 Base Trufast Inuldek Loc-Nail 9-inch o.c. in 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -30.0* CWF-6 Min. 2.5-inch Tectum Plank or Tectum LS Plank Nail Base, Polyglass G2 Base Trufast Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 20 of 22 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap G-1 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-Shield, Poly ISO 1 or min. 2.0 pcf, ASTM C578 expanded polystyrene OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -72.5 G-2 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch min. 2.0 pcf, ASTM C578 expanded polystyrene OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -112.5 G-3 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or H-Shield, Poly ISO 1 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -112.5 G-4 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or H-Shield, Poly ISO 1 or min. 2.0 pcf, ASTM C578 expanded polystyrene OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -112.5 G-5 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -72.5 G-6 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H-Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -202.5 G-7 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf EPS insulation board, ACFoam II, ACFoam III, ENRGY 3, H-Shield, Poly ISO 1, H-Shield CG or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -72.5 G-8 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf EPS insulation board CR-20 (Optional) additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0 G-9 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf EPS insulation board CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -240.0 G-10 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch ACFoam II, Poly ISO 2, ACFoam III, ENRGY 3, H- Shield, Poly ISO 1, H-Shield CG or Multi-Max FA3 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA, APP-TA -257.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 21 of 22 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasten Attach Base Ply Cap G-11 Existing sound poured gypsum or gypsum plank deck Nail Base, Polyglass G2 Base Trufast FM-75 or FM-90 or Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0* TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap SELF-ADHERING BASE PLY: R-1 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -67.5 R-2 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or Multi-Max FA3 or min. 2.0 pcf EPS insulation board D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -72.5 R-3 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf EPS insulation board D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -90.0 R-4 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf EPS insulation board D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP-SA -90.0 R-5 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2 or ENRGY 3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -90.0 R-6 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H- Shield, Poly ISO 1 or min. 2.0 pcf EPS insulation board OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -72.5 R-7 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf EPS insulation board OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0 R-8 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf EPS insulation board OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -120.0 R-9 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or H-Shield, Poly ISO 1 OB500 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -127.5 R-10 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H- Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -72.5 R-11 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H- Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -157.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Evaluation Report M10000.03.08-R6 for FL10497-R6 Certificate of Authorization #9503 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 6: 09/08/2017 Prepared by: Robert Nieminen, PE-59166 Mule-Hide Modified Bitumen Roof Systems; (608) 365-3111 Appendix 1, Page 22 of 22 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 11) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap R-12 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf ASTM C578 expanded polystyrene, Min. 2-inch ACFoam II, Poly ISO 2, min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL, H-Shield, Poly ISO 1, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -72.5 R-13 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 (Optional) additional layers(s) of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0 R-14 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -240.0 R-15 Existing asphaltic roof Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL, H-Shield, Poly ISO 1, H-Shield CG or ENRGY 3 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -240.0 R-16 Existing asphaltic roof Min. 2-inch ACFoam II, Poly ISO 2, ENRGY-3 or H- Shield, Poly ISO 1 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, APP-TA SBS-SA, APP- SA, APP-TA -247.5 TORCH-APPLIED BASE PLY: R-17 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -67.5 R-18 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3 or min. 2.0 pcf EPS insulation board D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board D-IS APP-TA (Optional) APP-TA APP-TA -90.0 R-19 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H- Shield, Poly ISO 1 or ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 APP-TA (Optional) APP-TA APP-TA -127.5 R-20 Existing asphaltic roof Min. 1.5-inch ACFoam II, Poly ISO 2, ENRGY 3, H- Shield, Poly ISO 1 or Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA APP-TA (Optional) APP-TA APP-TA -157.5 R-21 Existing asphaltic roof Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch ACFoam III or min. 1.0-inch ISO 95+GL, H-Shield, Poly ISO 1, H-Shield CG or ENRGY 3 or min. 2.0 pcf ASTM C578 expanded polystyrene CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5