Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TROP STL ROOF WIND PRESSURE AND ATTACHMENT DESIGN
FL. Cart. of Auth. #32207 Florida Leading Roof Consulting Source Specification & Design Visual Condition Surveys Roof Asset Management Programs • Quality Assurance Inspections ROOF WIND PRESSURE & ATTACHMENT DESIGN CLIENT: SUTTER ROOFING CO. Page 1 of 3 PROJECT NAME: TROPICANA FEED MILL -WAREHOUSE PROJECT ADDRESS: 6500 GLADES CUT-OFF ROAD FORT PIERCE, FLORIDA 34981 PROJECT DATA: MEAN HEIGHT: z := 43 FT SHAPE: GABLE WIDTH: W := 204 FT. SLOPE: "r" ( RISE in 12) r := 6 ENCLOSURE CLASS.: ENCLOSED BLDG. RISK. CATEGORY: If REGION: GULF SHORELINE WIND VELOCITY: V := 160 MPH EXPOSURE: C TOPO. FACTOR: H / Lh < 0.05 USE Kzt := 1.0. DIRECTIONAL FACTOR: Kd := 0.85 DESIGN CRITERIA: FLORIDA BUILDING CODE EDITION 2017 WIND DESIGN perASCE 7-10 Method 2: Analytical Procedure Attachments as per Factory Mutual FM 1-29 DESIGN SCOPE: ROOF CLADDING ATTACHMENT Basic Combinations Sec 2.4.1 Load Combination #7: 0.613 + 0.6W Neglect Deadload. (Sec.2.4.1), is Wind Uplift, 0.6W EDGE ZONE MULTIPLIER: z-0.40 = I T2 W410 = 20.4 Use Multiplier a := 20.4 METAL ROOF: _ 22-GAUGE STEEL CORRUGATED PANELS CALCULATE VELOCITY PRESSURE qz := 0.00256-Kz-Kzt•Kd-V2 qz = 59.025 PSF SLOPE 0 atan(r 12) = 26.565-deg D := 0.60 DATE: 11-16-2020 RE -CS W 19-273-corrugated2 EXPOSURE C z min = 15 ft. PRESSURE COEFFICIENT 2 9.5 Kz := 2.01. 900� Kz = 1.06 GABLE 7 < ,0 < 27 deg COMPONENTS & CLADDING: EXTERNAL COEFFICIENT GCp From Figure 30.4-513 INTERNAL COEFFICIENT: GCpi From Figure 26.11 -1 CALCULATE UPLIFT PRESSURES: ( perASCE 7-10 ) P:= Dqz-[(-GCp) + (CCpi)] FIELD PI := D•qz•[(-0.9) + (-0.18)] PERIMETER P2 := D•qz•[(-1.7) + (-0.18)] CORNER P3 := D-qz-[(-2-6) + (-0.18)] UPLIFT PRESSURES: PI =-38.248 psf P2 - -66.58 psf P3 =-98.454 psf FL Cert. of Auth. #32207 Florida's Leading Roof Consulting Source Svecification & Design! Vi,%W Condition Sw-veys • Roof Asset Management Programs • Quality Assurance Inspections ROOF WIND PRESSURE & ATTACHMENT DESIGN TYPE OF ROOF SYSTEM: 22-GAUGE STEEL 7/8" CORRUGATED PANELS Page 2 of 3 DATE: 11-16-2020 RE -CS I #:19-273-corruga ted2 ROOF SYSTEM ENGINEERING DATA: Mfg/Type: PETERSEN ALUMINUM CORP Florida Product Approval: #23953.1 22 GAUGE CORRUGATED STEEL 39.75" WIDE PANEL DESIGN PRESSURES: DPI := —78.6 PSF 5-FOOT JOIST SPACING DP2 := —159.8 PSF 2-FOOT PURLIN SPACING PANEL WIDTH: w := 39.75 IN FASTENER SPACING: FSl := 6 IN PS2 := 30IN FS3:= 15 IN TYPE OF FASTENER: #12-24 x 1-1/4" BLAZER TEK-5 SCREW TO STEEL JOIST 1/4 x 14 x 7/8" DPI/LAP w/VRT LAP SCREWS SUPPORT MATERIAL: 118"-1/4" STEEL JOIST CONSTRUCTION TYPE: REROOF METAL ROOF: 22-GAUGE STEEL CORRUGATED PANELS DESIGN FASTENER VALU ES ( fy ); w-6 ft] := DPI 144) =—130,181 w•6 fv2 = DP2 144 =—264.669 NOTE: PANELS ARE, 22 GA -STEEL, NOT 24 GAUGE AS PER THE APPROVAL.. A SUBSTITUTION HAS BEEN MADE USING THE 22 GA. PANEL UNDER THER PREMISE THAT THE RESULTING ATTACHMENT IS STRONGER THAN A 24 GA_ PANEL, WHEREAS EITHER MEETS OR EXCEEDS THE REQUIRED CRITERIA. RATIONAL ANALYSIS AS PER FBC 2017: Sec 1512.2.3 DESIGN FASTENER SPACING: TRIAL CALCULATIONS: DFS :_ 1}PFS PI -FIELD DPI = —78.6 > P1 = —38248 60" JOIST SPACING P P2- EDGE DPI = —78.6 > P2 = —66.58 60" JOIST SPACING P3- CORNER DP2 = —159.8 > P3 —98.45 24" PURLIN SPACING ATTACH TO 22 GAUGE CORRUGATED STEEL PANELS AS FOLLOWS: FIELD ( Zone 1 ): ATTACH' FASTENERS AT6" Q.C. PARALLEL TO ROOF SLOPE. ALONG PANEL RIB INTO STEEL JOISTS SPACING OF 5.0' O.C. MAXIMUM. SPACE SIDELAP FASTENERS AT30" Q.C. PERIMETER ( Zone 2 ): ATTACH FASTENERS AT6" O.C. PARALLEL TO ROOF SLOPE. ALONG PANEL RIB INTO STEEL JOISTS SPACING OF 5.0' O.C. MAXIMUM.. SPACE SIDELAP FASTENERS AT 15" O.C. CORNER (ZONE 3 )-. ATTACH FASTENERS AT6" O.C. PARALLELTO ROOF SLOPE. ALONG PANEL RIB INTO STEEL PURLINS SPACED ATOF 2.0' Q.C. MAXIMUM. SPACE SIDELAP FASTENERS AT 15" Q.C. DIMENSION OF EDGE ZONES: PERIMETER WIDTH: u = 20.4 ft. CORNER LENGTH: a = 20.4 ft. The Roof Code Provisions in Chapter 15 of the Florida Building Code 2017 & Factory Mutual 1-49 Apply To This Work. PANEL & FASTENER DETAILS METAL ROOF: _ 22-GAUGE STEEL CORRUGATED PANELS Page 3 of 3 DATE: 11-16-2020 RE-CSW 19.273-corrugated2 3 lam'" i W*�t `f - = - t tG MR" PCOMai mw DECK FASTENER TO STEEL JOIST St. VERIV sums cap mew TfthSFA._ Cola 1,Q(>3 r6 alit ,spay SIDE LAP FASTENER The Roof Code Provisions in Chapter 15 of the Florida Building Code 2017 & Factory Mutual 149 Apply To This Work. Digitally signed by �F Donald J Flood Date: gB�ONAI�� 2020.11.13 22:46:19 -05'00'