Loading...
HomeMy WebLinkAboutTROP STL PAC CLAD PRODUCT RPTProduct Report Manufacturer: Petersen Aluminum Corporation 102 Northpoint Building 106 Acworth, GA 30141 Florida Product Approval # 239S3 Sub -Category: Metal Roofing Compliant. ,, Building Code 2017 Compliant with Florida Product Approval Rule # 61G20-3 Compliant Quality Assurance Program: LIL LLC Snap-On StandingJ E .032" Aluminum w/ V Right Angle Vertical Legs Non-HVU Snap -An standing sears panels with concealed clips @ i2" o.c. with snap -on batten caps over clips and 1" high legs fastened to 19/32" plywood deck w/ corrosion resistant (2) #10-12 fasteners per clip. clips are concealed between the adjacent vertical legs of the panels & a batten cap is installed over the outside of the vertical legs to retainer lugs on the clips. Panel Width: Ir Design Pressure Material: I Support Spacing: j l 41.6 PSF x4 GA l 1'-0" o.c. 41,3 PSF .032" Alum. 1'-0" o.c. • .♦ .• es a 16oz Copper Snap -Clad panel with clips thru fastened to 19/32" thick APA plywood, grade B-C fastened with corrosion resistant (2) #10-16 x 1" long, SS, pancake head fasteners, two per clip. Manufacturer requires stainless steel fasteners. Panel Clip: one piece 3-%" wide x 1-7/8" high with a 1-3/8" wide, horizontal leg fabricated from No. 18 MSG stainless steel. Panel width.16" wide by 1-3/4" high rib at the female panel, sealant allowed at panel side joints. An underlayment of 60 MIL "high temperature" membrane is required by manufacturer. Fasteners thru clips to substrate are concealed behind the adjacent nesting/lapping vertical ribs of the panels. The panels were attached to the perimeter of the wood deck at 6" o.c. Panel Clip: Tite-Loc 2-Piece clips w/ #10-12 x 1" fasteners. • - i Panel (36" M-36 Panel installed over 166A Steel purlins @ le o.c. w/ the shorter side of the system fastened using corrosion resistant (1) #12 x 1-1/4"" HWH SDS w/ neoprene washer (per manufacturer) @ ea. valley located 6" o.c. The first panel & ea. panel joint was fastened at the longer side of the system using a single row of #12 x 1-1/4'" HWH SDS w/ neoprene washer (per manufacturer) @ 12" o.c. 2_46A Steel � O.032" Aluminum n Pressure: ; _ - Spacing: **Design Pressure: I -- Spacing: -**Design -80 PSF °i -120 PSF 1 @a 5' o.c. -70 PSF @ S' O.C. @ 1' o.c. -107 PSF SEE LOAD TABLES FOR MORE AVAILABLE fJ� **DESIGN MARGIN OF2.1 STATE OF �•,,,/ONA` ®;, . e panes were Installed over 166A supports fastened w/ corrosion resistant #12-14 x 1" self -drill fasteners w/ 0.55" ia, se,-1 washer head spaced as shown on the install detail. Panel side joints were overlapping using corrosion resistant #12-14 x 19" self - drill lap fasteners w/ O.55" dia. seal washer head located at 12" o.c. 22GA I 24GA **resign Pressure. Spacing ; "Design Pressure: Spacing: -52.8 PSF @ S' o.c. -49.5 PSF @ 5' O.C. -154.3 PSF 2' D.C. -159.1 PSF @ 2' O.C. 0.032" Aluminum 0.040" Aluminum 1 Spacing **Design Pressure: Spacing. - "Design Pressure: } -28.0 PSF S' O.C. -49.7 PSF @ S' O.C. -143.2 PSF 2' o.c. -143.2 PSF The panels were installed over 16GA supports fastene w corrosion resistant 1 4" --14 x 1-1 d" long hex head self dril astener with 5/8" seal washer located at every low cell of the panel. The panel side -Joints were overlapping corrosion resists^:.':A2-14 x 1" long hex head self -drill fasteners w/ 5/9" seal washer @ 18" o.c. _ MA Steel 0.032" Alum. Gauge "Design Pressure: Spacing: "Design Pressur-e—:-- spacing: -78.8 PSF @ S' O.C. -61.1 PSF I @ S' O.C. The 24GA Steel panels were fastened over 16GA supports using corrosion resistant W-14 x 1-1/4" long hex Dread self -drill fasteners w/ 5/8" seal washer located at every other low cell of the panel as shown on install details. The fixed end was `astcned at every low cell of the panel. The panel side -joints were single overlapping fastened w/ corrosion resistant #12-14 x 1" long hex head self -drill fasteners w/ SIB" seal washer @ 12" o.c. 24GA Steel *Design Pressure: I Spacing -79.6 PSF ( @ S' mc. -159.8 PSF I @ ,2' O.C. t ne o.U$Z" Aluminum panels were fastened over 16GA supports using corrosion resistant W-14 x 1-1/4" long hex head self -drill fasteners w/ 5/8" seal washer located at every other low cell of the panel as shown on install details. The fixed end was fastened at every low cell of the panel. The panel side -joints were overlapping fastened w/ corrosion resistant #12-14 x 1" long hex head self -drill fasteners w/ 5/8" seal washer @ 12" o.c. 0.032" Aluminum **Design Pressure: Spacing: -47.1 PSF _ @ S' O.C. -IS6.4 PSF @ 2' O.C. Standing seam panel was fastened over min. 22GA, Grade 33 B-deck *max. S' o.c. with clip using corrosion resistant `2j #14.10 Dekfast screws per clip'through 4" x S" x 166A bearing plate and rigid insulation into deck; fastener should be of sufficient length to penetrate min. " through the deck. Tite-Loc Plus AR sliding clip: 2 fasteners per clip, Clip Tab: 4.313" wide, SOW, 226A 690 Coated Steel; Clip Base: 2.5" wide, SOW,18GA G90 coated steel. MSA "Quick Stick HT" 40 mil peel & stick or approved equal. Installed over insulation board as per manufacturer's install guidelines. Insulation board: 2" min. - 4" max. thickness to comply w/ FBC 2017. Slope Y:12 or greater in accordance w/ FBC 2017. Rib Height: 2„ **Design Pressure: Clip Spacing: -52.5 PSF @ 48" o.c. -160.95 PSF @ 12" o.c. 1 **DESltilt,� RiCt#9�ES A SAFETY MARGIN pF. Certificate of Independence:*Q*` Locke Bowden, P.E. does not have, not will acquire a financial interest +7Ai ci�r�ariuf ul�ng or distributing 'products under this evaluation. * / Locke Bowden, P.E. is not owned, operated, or controlled by any conXppriy, manufacturer, or di R:ri ding products t.�04 M.-er this report. A. `AT'i~, 9T. 00 ,,.