HomeMy WebLinkAboutPlan, interiorT SURFACE MOUNTED LIGHT FIXTURE O EXHAUST FAN OUTLET DUPLEX OUTLET .g} SWITCH NOTE RECEPTACLES IN KITCHEN & BATH AREAS TO BE 48" AF.F. ALL 120V SINGLE PHASE 16 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 16 & 20 AMP BRANCH CIRCUITS Existing Lay. Location. No changes to the existing plumbing New New 3" drain — Exist. Assumed Existing WC drain lines — under slab f"I�i���l•�i���11 E"I71 RM1115121 1� .. Assumed Vent thru Roof INTERIOR WALL FRAMING NOTE Interior non bearing walls to be 2 x 4 studs 24"o.c. Spruce, Pone, Fir (SPF) #2 Grade lumber or better or metal studs (25 Ga.) Crimper may be used in lieu of screws. GENERAL CONCRETE NOTE Slab and foundation already exists, where concrete must be cut, ensure the following. Concrete shall have a minimum compressive strength of not less than 3000 p.s.i. over compacted, and termite treated soli. PLUMBING NOTES: duct Plumber to consult with contractor and equipment ordered for rough in dimensions. Soffit Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. All sanitary lines 2" or less shall have a slope of 1/4" per foot minimum. All sanitary lines above 2" shall have a slope of 1/8" per foot minimum. Ren scale, 1/4°9 ® 19_099 TERMITE TREATMENT REQUIRED THESE PLANS AND ALL PROPOSED WOFi<. " ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT ". MAYBENECESS;RY,INPQ DER -TO 1` COMPLYWIITH ALL'APPLICABLE CODES. 0J3�e ST. LUCIR COUNTV RIJIT,PTvg; TIMSION RFVTFR I' D FOR COi CE REVILWE_Iy li S1 JL yvs-oar`( Q DATE �JJ PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE BLADE. Existing Interior (Non) Bearing walls to be removed Remove and Relocate the Existing WC isting Window Remain Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index ill !I�. I��I ' �.I 1 � �!'�' Ei it � i• �• '� GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project„ unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included In the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. STRUCTURAL NOTES: All wood in contact with masonry shall be pressure treated or approved separating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. Structural Concrete shall attain a minimum ultimate compressive strength (Fc`) in 28 days as follows: Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof: see column schedule. All other concrete: 3000 p.s.i. All wood members shall have— minimum fiber stress In bending of 1200 p.s.i. with 1/360 max. deflection. Project Name: XXXX Street Address: 7671 Charleston Way City: Port St. Lucie County: St. Lucie State: Florida 110 1111111 RBI SIII =1 No changes to the existing HVAC system within this project. 5th Edition Florida Building Code: Residential 5th Edition Florida Building Code: Existing 'Buildings Alteration Level II 2011 National Electric Code NFPA 70 Wall Key New Frame Walls Mon 4oad BMW Existing Walls to be Removed Existing Walls to Remain ---------- rI---------- EXISTING f M9 (0) I" '4 1 scar e, 1/499 O 1'-09 wall to w the ceiling LJ d c co CL Cn O W LL Z CD W Lo 00 0 Q Jrz a .� LL Z c 06 W 0 U U Q 0 4- 0 LLJ 4-0 V♦ ca ® 4� ®y > co LO W L x ® z 470 W U ®� r- 75 Q f2 O LL Z Q > > d � Z CL 0O z Qall W V LU CC O — n 0 J Z 4) D Q U TVV I, - W f!� W cc drawn al chocked al. date 1/23/17 scale ` as noted job number 17001 sheet A-1