Loading...
HomeMy WebLinkAboutBlower Door Test C M Planning&Development Services IRS Building&Code Regulation Division 2300 Virginia Ave, Rm 201 • • Fort Pierce, FL 34982 RECEIVED Phone:772-462-2165 Fax: 772-462-6443 O C T 2 0 2020 BLOWER DOOR TEST FORM ST. Lucie County, Permitting House Infiltration Test Certification Prescriptive and Performance Method Date: 0 ;Lo Permit#: S-LG /Cl/o — a 't© Contractor: O 1901Q LAS ZN4, Job Address: 70 Al Y:rt 6 9C, Construction: New Construction—Complete ( ) Existing—After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50)= g 16,8' Test Date: 14 Ra 20 a Volume= 0 /(2 0f ACH (50)=CFM (50)x 60/Volume= S.-D% Mechanical Ventilation required less than 3 ACH Passing results must be&ACH (50)or less iifpass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be-conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or(i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3. Testing Company90 ddla E Company Name: EAST �D s7- &"uJM IDDtlf�ddress: U �'1 3 '7 1 hereby certify thatWe_�jlove House Infiltration results demonstrate compliance with FBC Energy Conservation requirements i ccor nce with Sect' 402.4.1.2 Climate Zone 2. Signature: a Printed Name: V��� ►l kN D U56NI License/Certification#: 3-3 tare Certificate of Excellence { i is awarded to Scott VanDusen who has successfully completed a comprehensive evaluation and is certified as a Infiltration & Duct Leakage as of July 10, 1018 This temporary Certificate expires on 0711012021 i i BUILDING PERFORMANCE INSTITliTE, INC. 107 Hermes Rd Suite 110,Malta,New York 12020 `= wlvw.bpixrg