HomeMy WebLinkAboutCompaction test, 257 Bimini Dr with permit #rye P
'eRNATI�H
Part St. Lucie
FBPE CA N 4930
607 NW Commodity Cove
Port St. Lucie, FL 34986
Phone:772-924-35751 Fax,772-924-3580
Soil Nuclear Gauge
Report Date: 11/2/2020
Test Method: ASTM D 6938
Client:
Family Pools Inc
873 SW South Macedo Blvd.
Port St Lucie, FL 34983
Project:
20-2365.00
Family Pools Inc. 2020-2021 Master Agree
North Palm Beach, Martin, Saint Lucie, Indian...
FL
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
M
Maximum
Dry Density
(pef)
In Place
Moisture
(%)
In Place
Dry
Density
(pc
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
7
10/29/20
1775 - D1557
NIA
11.8
107.7
11.3
103.5
115.2
12
96
95 / 105
Pass
8
10/29/20
1775 - D1557
NIA
11.8
107.7
11.4
103.4
115.2
12
96
95 / 105
Pass
9
10/29/20
1775 - D1557
NIA
1 11.8
1 107.7
11.3
103.1 1
114.8 1
12
1 96
1 951 105
1 Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make I Model I SN 1 Calibrated
Field Technician
7
Above Bottom of Structure: Northeast comer of Swimming Pool, 257 Bimini Dr, Ft
Pierce
0-1
Troxler 1 T3430136442 1
Rogers, Mark
8
Above Bottom of Structure: Southeast corner of Swimming Pool, 257 Bimini Dr, Ft
Pierce
0-1
Troxler I T3430136442 1
Rogers, Mark
9 1
Above Bottom of Structure: Southside of Swimming
Pool, 257 Bimini Dr, Ft Pierce
0-1
Troxier / T3430 / 36442 /
Rogers, Mark
Remarks
I Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter'. Gauge calibration data on rile with the testing agency.
`\`�ttllfrrrll�
SOHN • K���VT'''�
'V�cENsF'
No 63
02dO20
1 Kent, .E. CC—
r1r isionfill-Mc ?leer 94
Sf F1o&WIO..
!!lffltit
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1