Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISION, A-4 R (3) 11.23.20
FATHI ARCHITECTS, INC. '/FT. SLOPE (TYP) WALL SECTION 1 /16" V 2"_ T (TYP) 1/4"/FT. SLOPE (TYP) /I/-FT.5LOFE (TYP) NOTE. ALL WELDING TO BE IN ACCORDANCE W/ AMERICAN WELDING STANDARD, II AND STATE CERTIFIED WELDER 15 REQUIRED FOR ALL FIELD WELDIN05. II ODIFIED ROOFING OVER 5/8" ON 2X4�11,".G. SLOPE I (TYPJ II 3/Ib" 3/16" u it 8" I'• '•I 5"x5"x5/&" STEEL BEAM (TYP.) 4"X4"XI/4" STEEL COL. WELDED TO CHANNELS AND 4"XI2"XI/2" TOP PLATE (TYP.) NOTE: REMOVE CONTAINER'S WALL AFTER ALL REINFORCING HAS BEEN PLACED AND WELDED (TYP.) 5"X5"XI/2" STEEL PLATE W/ (2) 5/8" VIA. X4" STUD ANCHOR @ EACH CORNER WELDED TO THE STEEL CHANNELS OF THE CONTAINER W/ 5/16" WELD (TYP.) ;(TYP.) 8"XI2" GONG. COL. W/ 4#5 VERT. AND #5 TIES 8" (TYP.) WALL SECTION TYP. INTERIOR ELEVATION 3/4'9 1/4"/FT. SLOPE (TYP 12 GA. STEEL RO F PANEL OF CONTAINER (TYP.) 2"X2"X 66A. TOP IL OF CONTAINER ( P) 12 GA. GORRUGA 51DE PANEL (TYP SGA. "G" STEEL J 15T OF COW. @ 12" O.c. WELDED TO BOTTOM RAIL (TYP) G SNAPPED GOL STEEL FORMED (56A.) G NT. BOTTOM RAIL (TY .) OAF ROBEROID MODIFIED BITUMEN ROOF SYSTEM FOR WOOD DECK. NOA 18-Og1a.12 5/8" GDX PLYWD. 5HEATHIN5 OVER 2X4 P.T. SLOPE TO THE EDGE @ 16" O.G. (TYP.) IX6 P.T. NAILER CONT. (TYP.) MODIFIED ROOFING OVER 5/8" PLYWD., ON 2X4 AT 16" O.G. _ CONT. 6ALV. DRIP EDGE (TYP.) SHAVE 2X4 TO MAKE THE SLOPE W/ #12 SELF TAPPING 5.5. 5GREWS i ® 8" O.G. (TYP.) - \ CONT. IX6 P.T. W/ #12 5 LF APPING 5.5. SCREWS 5" O.G. TYP.)T 1 @ CONT. MTL. DRIP (TYP.) EXIST. STEEL DECKING (TYP.) OL If TOP OF ROOF ROOF DETAIL 3/4�' 5/8" DRYWALL ON 5 5/&" (256A.) MTL STUDS AT 16" O.G. W/ R=50 IGYNENE INSULATION (TYP.) 5MO07H 57UCGO ON VINYL MESH OVER 1 1/2" FOAM OVER THE CONTAINER'S SKIN (TYP.) 1/2" DRYWALL ON 2 1/2" 20 GA. STUDS @ 16" O.G. BRACED TO THE SKIN W/ R=11 IGYNENE INSULATION (TYP) LAM. FLOORING OVER EXIST. CONTAINER'S FLOOR (TYP) 4" GONG. SLAB W/ 6X6 HIAXHIA W.W.F. ON WELL COMP. TREATED FILL (TYP.) (TYP) +10'-0" OL TOP OF SECOND FLOOR 8"X5"XI/2" STEEL PLATE W/ (2) 5/5" PIA. X4" STUD ANCHOR IS EACH CORNER WELDED TO THE STEEL CHANNEL OF THE CONTAINER W/ 5/16" WELD (TYP) #5 N05E BAR (TYR) 5" G.M.U. W/ #5 @ 52" O.G. W/ 8"X,5" GAP Al 2#5 CONT. GONG. FILL ALL CELLS (TYR) CONCRETE FOOTING 16"XI2" FT6. W/ 2#5 SEE STRUCTURAL (TYP.) GONT. (TYP) c WALL SECTION 2" A-4 5/5" DRYWALL ON 5 5/8" FURRING @ 24" O.G. HORIZONTALLY W/ R=50 IGYNENE INSULATION (TYP.) SMOOTH 5YUGG0 FIN. ON VINYL REINF. MESH OVER 1 1/2" FOAM OVER STEEL SKIN (TYP.) 1/2" DRYWALL ON 20 ga. 2 1/2" MTL. STUDS @ 16" O.G. BRACED TO THE SKIN W/ R= II IGYNENE INSULATION (TYP.) IX6 CONT. AD. BASE (TYP.) LAMINATE FLOORING OVER 5/8" PLYWOOD SHEATHING ON 50# FELT OVER THE CONTAINER'S FLOOR (TYP.) CONTAINER'S FLOOR SYSTEM (TYP.) CONTAINER'S SKIN (TYP.) 5"X5"X5/8" STEEL BM. (TYP.) 4"X4"XI/4" 5TEEL COL. (TYP.) /16" „ 211-2411 3/16" COL./BM. CONN. 3/4" CONTAINER'S COL. (TYP.) 4"X4"XI/4" 5T1 COL. (TYP.) INTERIOR COL® DETAIL 11yj A to8:M11►Y[mim IN TYP.) 5/5" DRYWALL ON 5 5/5" FURRING @ 24" O.G. HORIZONTALLY W/ R=50 IGYNENE INSULATION (TYP.) 2"X4"XI/8" STEEL TUBE TO FRAME ALL WINDOWS/DOORS OPENING, EXTEND VERTICAL FULL LENOHT FOR ALL DOORS AND OPENING OVER 8'-O" (TYP.) SMOOTH 5YUGCO FIN. ON VINYL REINF. MESH OVER 1 1/2" FOAM OVER STEEL SKIN (TYP.) 1/2" DRYWALL ON 20 GA. 2 1/2" MTL. STUDS @ 16" O.G. BRACED TO THE SKIN W/ R= 11 IGYNENE INSULATION (TYP.) IX6 CONT. AL.). BASE (TYP.) LAMINATE FLOORING OVER 5/8" PLYWOOD SHEATHING ON 50# FELT OVER THE CONTAINER'S FLOOR (TYP.) CONTAINER'S FLOOR SYSTEM (TYP.) 3 / A 97 TYP. WINDOW/DOOR OPENING DETAIL 3/4" 2 "X2"X I /4"XO'-8" STEEL ANGLE @ 24" O.G. (TYP.) STEEL BEAM AND COLUMN (TYP.) CONTAINER'S SKIN (TYP.) 8„ (TYP.) /TYP.) COL®/]FAIT® CON /499 CONTAINER'S SKIN (TYP.) 4"X4"XI/4" STEEL COL. (TYP.) 2 "X2 "XI/4"XO'-8" STEEL ANGLE, 4 PER COL. EACH SIDE (TYP.) 3/499 SIDE COL® DETAIL 0 I + 4"X4"XI/4" STEEL COL. (TYP.) 2 "X2 "XI/4"XO'-8" STEEL ANGLE, 4 PER COL. EACH SIDE (TYP.) COL./CONTAINER CONN® 3/499 3/ " CORRUGATED 12 CcA. GONTA I NER GE I L I NG (TYP.) DRYWALL ON 5 5/8" STUDS (g 16'' O.G. (TYP.) 1/2" DRYV,IALL FIN. ON 3 5/8" (25 GA.) METAL STUDS © 24" O.G. NOTE: PRO\/IDE DE3L. STUDS ® DOOR OPEN I NC-� (TYP.) CONT. TRACK Val/ H I LTI "ENKK" POWER AGT. 24" O.G. (TYP.) IXF GONT. WD. BASE (TYP.) LAMINATE FLOORING 5/8" PLYWOOD SHEATHING ON SO# FELT OVER THE CONTAINER'S FLOOR (TYP.) GONTA I NER'S FLOOR LINE (TYP.) INTERIOR PARTITION DETAIL 1 "=1' PART 1 T I ON SUPPORT 1 NG PLUMBING FIXTURES AND CABINETS SHALL BEE LDBL. 25 GA. AT IG" O.G. (TYP.) 0. • . �.. uigitaiiysigneci ghar J. by Asghar J. Fa I, Fathi, AA0016049 AA 016049 Date: 2020.11.23 07:50:56-05'00' TANT: o w OWNER: ADDRESS: 4710 MIDWAY RD. FORT PIERCE, FLORIDA PHONE: REVISIONS DATE BY BUILDING DEPART 04/17/20 R.R. BUILDING DEPART 04/27/20 R.R. COPYRIGHT 1997, FATHI ARCHITECTS, INC. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR PRESENTED BY THIS DRAWINGS ARE OWNED BY, AND ARE THE PROPERTY OF FATHI ARCHITECTS, INC. AND WERE CREATED AND DEVELPOED FOR USE ON, AND IN CONNECTION WITH THIS SPECIFIED PROJECT. THESES IDEAS, DESIGNS, ARRANGEMENTS AND PLANS ARE NOT TO BE USED, DISCLOSED, REPRODUCED, ALTERED, COPIED OR TRANSFERRED IN ANY FORM OR MANNER WHATSOEVER, WITHOUT THE SPECIFIC WRITTEN PERMISSION OF 'FATHI ARCHITECTS, INC.* WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR DIMENSIONS AND CONDITIONS ON THE JOB. FATHI ARCHITECTS, INC. MUST BE NOTIFIED IMMEDIATELY IN WRITING OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. FIELD VERIFY ALL CONDITIONS PRIOR TO LAYING OUT OR FABRICATING ASSOCIATED WORK. DATE: 07/15/Iq SCALE: A5 SHOWN DRAWN: R.R. CHECKED: A.F. COMMISSION NO.: 071511 SHEET SHEET NO. OF