Loading...
HomeMy WebLinkAboutGrowth Management Division PermitS T. L U C I E C 0 U N T Y 2300 Virginia Avenue Ft. Pierce, Florida 34982 Growth Management Division PERMIT Page 1 Permit #: 21010464 Type: BUILDING COMMERCIAL Insp Area 1 Issued: 05/01/01 Master Nbr. 21010464 Job Location: 4590 OLEANDER AVE / FT PIERCE Jurisdiction: ST LUCIE COUNTY Lot: P8 Blk: Subdiv: WHITE CITY S/D Parcel: 3403-502-0023-000/4 Owner's Name: FT PIERCE LODGE #87, Flood: X Elev: Project: Job Description: NEW COMMERCIAL BUILDING - FT PIERCE MASONIC L Applicant Name: G MACK SR WORLEY Type: CONTRACTOR Contact Phone: (863) 467-2541 Double Fee: N Contractor Name: WORLEY, G MACK SR Cert Nbr: 16456 Business Name: G M WORLEY INC Setbacks Left: 100.00 Right: 172.75 Front: 96.00 Rear: 313.20 Fire Marsh Nbr: Stub Out: T-Pole: Utility COs: FPUA Addl Information: FIRE DEPT FAILED THEIR FINAL INSP ON 11/01/01 - NO WATER OR BACK FLO PREVENTOR HOOKED UP - CALLED HOOT/CONTR LEFT MESSAGE ON ANSWERING MACHINE 11/02/01 MS LANDSCAPE BUFFER AGREEMENT MADE BETWEEN RAY WAZNY & CONTRACTOR (SEE EMAIL IN PERMIT APPLICATION).,.PERMIT ISSUED PER RAY WAZNY 5/1/01. KC SUB -PERMITS PERMIT # STATUS PT CERT # DBA JOB DESCRIPTION 2,1010464 INSP BC 16456 G M WORLEY INC NEW COMMERCIAL BUILD 21010465 ISSD EP 18821 SEMINOLE OF OKEECHOBEE/JU ELECTRICAL SUB FOR C 21010466 ISSD PP 622 LINDQUIST PLUMBING & SUPP PLUMBING SUB FOR COM 21010467 ISSD ME 9441 NEWMAN AIR COND INC MECHANICAL SUB FOR C 21010468 ISSD RP 16456 G M WORLEY INC ROOFING SUB FOR COMM INSPECTIONS - For Requests, Call: (561) 462-1261 REINSPECTION FEES REQUIRED: 4 REINSPECTION FEES PAID: 4 Req Description Pr Date Res Description Insp Date 261 (EL) 30 DAY EXPIRE 9 11/16/01 *** LATE *** COMMENTS: REQ ADDED DUE TO FAILED INSP 07:16:24 16 OCT 2001 801 (ZC) PAVING AND DR 9 11/16/01 *** LATE *** 999 (*) FINAL INSPECTI 9 COMMENTS: REQ ADDED DUE TO FAILED INSP 07:15:29 420 (PL) PLUMBING ROUG 1 05/18/01 90 APPROVED COMMENTS: AUTOMATED RESULT 10:44:09 18 MAY 2001 16 OCT 2001 BLD05 05/18/01 l S T. L U C I E C 0 U N T Y 2300 Virginia Avenue Ft. Pierce, Florida 34982 Growth Management Division PERMIT Page 2 Permit #: 21010464 Type: BUILDING COMMERCIAL Insp Area 1 Issued: 05/01/01 Master Nbr. 21010464 Job Location: 4590 OLEANDER AVE / FT PIERCE Jurisdiction: ST LUCIE COUNTY Lot: P8 Blk: Subdiv: WHITE CITY S/D Parcel: 3403-502-0023-000/4 Owner's Name: FT PIERCE LODGE #87, Flood: X Elev: Project: Job Description: NEW COMMERCIAL BUILDING - FT PIERCE MASONIC L INSPECTIONS - For Requests, Call: (561) 462-1261 REINSPECTION FEES REQUIRED: 4 REINSPECTION FEES PAID: 4 Req Description Pr Date Res Description Insp Date 104 (ST) COMPACTION TE 1 05/22/01 90 APPROVED GTM24 05/22/01 103 (EL) EUFFER GROUND 2 05/24/01 82 DISAPVD/REINSP FEE R BLD05 05/24/01 COMMENTS: NOT THERE 105 (ST) FORM BOARD SU 2 05/24/01 90 APPROVED COMMENTS: KATHY 115 (ST) SLAB 2 05/24/01 81 DISAPPROVED COMMENTS: CAN'T SIGN OFF WITH OUT EUFFER & TERMIT PASSING INSP 121 (ST) TERMITE SPRAY 2 05/24/01 81 DISAPPROVED COMMENTS: NO PROOF OF TERMITE OK TO SIGN OFF AFTER OUR OFFICE RECEIVES PROOF OF TERMITE 103 (EL) EUFFER GROUND 2 05/25/01 90 APPROVED 115 (ST) SLAB 2 05/25/01 90 APPROVED 121 (ST) TERMITE SPRAY 2 05/25/01 90 APPROVED COMMENTS: RCVD PROOF OF TERMITE SPRAY REQ ADDED DUE TO FAILED INSP 07:20:24 118 (ST) COLUMN 3 06/04/01 90 APPROVED 125 (ST) TIE -BEAM 3 06/04/01 90 APPROVED COMMENTS: victoria 863-467-2541 BLD26 05/24/01 BLD05 05/24/01 BLD18 05/24/01 BLD18 05/25/01 BLD18 05/25/01 BLD18 05/25/01 25 MAY 2001 BLD18 06/04/01 BLD18 06/04/01 S T. L U C I E C 0 U N T Y 2300 Virginia Avenue Ft. Pierce, Florida 34982 Growth Management Division PERMIT Page 3 Permit #: 21010464 Type: BUILDING COMMERCIAL Insp Area 1 Issued: 05/01/01 Master Nbr. 21010464 Job Location: 4590 OLEANDER AVE / FT PIERCE Jurisdiction: ST LUCIE COUNTY Lot: P8 Blk: Subdiv: WHITE CITY S/D Parcel: 3403-502-0023-000/4 Owner's Name: FT PIERCE LODGE #87, Flood: X Elev: Project: Job Description: NEW COMMERCIAL BUILDING - FT PIERCE MASONIC L INSPECTIONS - For Requests, Call: (561) 462-1261 REINSPECTION FEES REQUIRED: 4 REINSPECTION FEES PAID: 4 Req Description Pr Date Res Description Insp Date 140 (ST) CONR/FRAMING 5 07/24/01 82 DISAPVD/REINSP FEE R BLD05 07/24/01 COMMENTS: TRUSSES DO NOT MATCH CUT SHEET THAT ARE INSTALLED C-3, H-4, E2, D3 SEVERAL TRUSSES MISSING BRACE WOOD CIRCLED IN RED ON CUT SHEETS AUTOMATED RESULT 10:57:04 24 JUL 2001 238 (EL) ELECTRIC ROUG 5 07/24/01 90 APPROVED COMMENTS: MISSING 1 MUD RING ON INTERIOR WALL BLD28 07/24/01 351 (ME) MECHANICAL RO 5 07/24/01 82 DISAPVD/REINSP FEE R BLD28 07/24/01 COMMENTS: 1.NEEDS EXHAUST FANS DUCTED TO OUTSIDE 2.CHEK DUCT WORK WHERE FIRE SPRINKLER IS BEING INSTALLED TO MAKE SURE DUCT IS NOT CRIMPED TOO MUCH 423 (PL) PLUMBING TOP 5 07/24/01 90 APPROVED BLD05 07/24/01 COMMENTS: AUTOMATED RESULT 10:57:50 24'JUL 2001 140 (ST) CONR/FRAMING 5 07/26/01 90 APPROVED BLD23 07/26/01 COMMENTS: NEW REPAIRED TRUSS CUT SHEETS & CHANGED TRUSSES IN OFFICE FILE AUTOMATED RESULT 14:04:41 26 JUL 2001 S T. L U C I E C O U N T Y 2300 Virginia Avenue Ft. Pierce, Florida 34982 Growth Management Division PERMIT Page 4 Permit #: 21010464 Type: BUILDING COMMERCIAL Insp Area 1 Issued: 05/01/01 Master Nbr. 21010464 Job Location: 4590 OLEANDER AVE / FT PIERCE Jurisdiction: ST LUCIE COUNTY Lot: P8 Blk: Subdiv: WHITE CITY S/D Parcel: 3403-502-0023-000/4 Owner's Name: FT PIERCE LODGE #87, Flood: X Elev: Project: Job Description: NEW COMMERCIAL BUILDING - FT PIERCE MASONIC L INSPECTIONS - For Requests, Call: (561) 462-1261 REINSPECTION FEES REQUIRED: 4 REINSPECTION FEES PAID: 4 Req Description Pr Date Res Description Insp Date 351 (ME) MECHANICAL RO 5 07/26/01 81 DISAPPROVED BLD19 07/26/01 COMMENTS: FLEX DUCT MUST BE SUPPORTED, SO IT WILL NOT KINK, AT FRONT OF HALLWAY OVER THE SPRINKLER PIPE FLEX DUCT RUNNING EAST DOWN HALLWAY MUST BE STRAP SUPPORTED CANNOT USE TRUSSES FOR SUPPORT THE 113" FLEX DROPS IN MAIN ROOM ( SOUTH OF MAIN TRUNK) HAVE A BENDING RADIUS TOO SMALL CAUSING KINKS IN DUCT BEND MUST BE 1 1/2 TIMES THE DUCT SIZE AUTOMATED RESULT 08:56:57 26 JUL 2001 351 (ME) MECHANICAL RO 5 08/01/01 90 APPROVED BLD05 08/01/01 COMMENTS: VICTORIA GM WORLEY 863-467-2541 REQ DUE TO FAILED INSP 08:56:57 26 JUL 2001 141 (ST) INSULATION 6 08/02/01 90 APPROVED BLD33 08/02/01 COMMENTS: AUTOMATED RESULT 11:35:41 02 AUG 2001 167 (ST) ROOF FINAL 6 08/02/01 81 DISAPPROVED BLD33 08/02/01 COMMENTS: UNABLE TO INSPECT DUE TO HEAVY RAIN AUTOMATED REQUEST 15:49:47 01 AUG 2001 145 (*) TRUSS DRWG 6 08/03/01 90 APPROVED BLD05 08/03/01 167 (ST) ROOF FINAL 6 08/03/01 90 APPROVED BLD05 08/03/01 COMMENTS: REQ ADDED DUE TO FAILED INSP 15:14:20 02 AUG 2001 259 (EL) POWER RELEASE 7 09/13/01 90 APPROVED GTM24 09/13/01 260 (EL) 30 DAY FOR TE 8 09/24/01 90 APPROVED BLD28 09/24/01 COMMENTS: FPL EILEEN 9:25 - MS & FAXED POWER 11:00 - MS jimmy seminole elec. 863-763-0060 S T. L U C I E C 0 U N T Y 2300 Virginia Avenue Ft. Pierce, Florida 34982 Growth Management Division PERMIT Page 5 Permit #: 21010464 Type: BUILDING COMMERCIAL Insp Area 1 Issued: 05/01/01 Master Nbr. 21010464 Job Location: 4590 OLEANDER AVE / FT PIERCE Jurisdiction: ST LUCIE COUNTY Lot: P8 Blk: Subdiv: WHITE CITY S/D Parcel: 3403-502-0023-000/4 Owner's Name: FT PIERCE LODGE #87, Flood: X Elev: Project: Job Description: NEW COMMERCIAL BUILDING - FT PIERCE MASONIC L INSPECTIONS - For Requests, Call: (561) 462-1261 REINSPECTION FEES REQUIRED: 4 REINSPECTION FEES PAID: 4 Req Description Pr Date Res Description Insp Date 115 (ST) SLAB 0 10/08/01 90 APPROVED BLD18 10/08/01 COMMENTS: FOR SIDEWALKS AND OUTSIDE SLABS FOR HANDICAP AND PATIOS VICTORIA 863-467-2541 121 (ST) TERMITE SPRAY 0 10/08/01 81 DISAPPROVED BLD18 10/08/01 COMMENTS: NEED PROOF OF TERMITE SPRAY ON AREAS 121 (ST) TERMITE SPRAY 0 10/15/01 90 APPROVED BLD18 10/15/01 COMMENTS: REQ ADDED DUE TO FAILED INSP 13:57:22 08 OCT 2001 280 (EL) ELECTRIC FINA 9 10/15/01 82 DISAPVD/REINSP FEE R BLD19 10/15/01 COMMENTS: NO ENTRY LIGHT OUTSIDE FRONT EGRESS DOORS NO LIGHT AT NORTH EGRESS DOORS STRAP LATERAL RISERS AT METER MUST HAVE BONDING JUMPERS IN MAIN PANELS BOTH AUTOMATED RESULT 12:45:35 15 OCT 2001 380 (ME) MECHANICAL FI 9 10/15/01 81 DISAPPROVED BLD19 10/15/01 COMMENTS: A/C COMPRESSORS NOT STRAPPED IN PLACE HEAT KITS NOT MARKED ON AHU LABELS DRAIN PIPE FITTING AT EAST UNIT IS DAMAGED AND WILL LEAK PLEASE SEAL WITH ONLY (1) DRAIN PER AHU THESE UNITS SHOULD HAVE OVERFLOW SHUT OFF RESEAL LOOSE DUCT TAPE AT N AHU A/C FILTER IN LOBBY NOT PROPERLY INSTALLED AUTOMATED RESULT 12:45:56 15 OCT 2001 480 (PL) PLUMBING FINA 9 10/15/01 81 DISAPPROVED BLD19 10/15/01 COMMENTS: CLEAN OUT NOT TOO GRADE AND NO PLUG INSTALLED AUTOMATED RESULT 12:46:14 15 OCT 2001 S T. L U C I E C O U N T Y 2300 Virginia Avenue Ft. Pierce, Florida 34982 Growth Management Division PERMIT Permit #: 21010464 Type: BUILDING COMMERCIAL Insp Area 1 Issued: 05/01/01 Master Nbr. Job Location: 4590 OLEANDER AVE / FT PIERCE Jurisdiction: ST LUCIE COUNTY Lot: P8 Blk: Subdiv: WHITE CITY S/D Parcel: 3403-502-0023-000/4 Owner's Name: FT PIERCE LODGE #87, Flood: X Project: Job Description: NEW COMMERCIAL BUILDING - FT PIERCE MASONIC L Page 6 21010464 Elev: INSPECTIONS - For Requests, Call: (561) 462-1261 REINSPECTION FEES REQUIRED: 4 REINSPECTION FEES PAID: 4 Req Description Pr Date Res Description Insp Date 999 (*) FINAL INSPECTI 9 10/15/01 81 DISAPPROVED BLD19 10/15/01 COMMENTS: AUTOMATED REQUEST 12:32:14 12 OCT 2001 261 (EL) 30 DAY EXPIRE 9 10/24/01 81 DISAPPROVED BLD18 10/16/01 COMMENTS: NEED TO GO UNDERGROUND - ACROSS THE ROAD WITH THE FIRE SPRINKLER SYS 425 (PL) SEWER CONNECT 0 10/25/01 90 APPROVED BLD19 10/25/01 COMMENTS: MARYLAND 863-467-2541 165 (ST) HANDICAP REST 9 10/25/01 90 APPROVED BLD18 10/25/01 180 (ST) BUILDING FINA 9 10/25/01 90 APPROVED BLD18 10/25/01 280 (EL) ELECTRIC FINA 9 10/25/01 90 APPROVED BLD19 10/25/01 COMMENTS: REQ DUE TO FAILED INSP 12:45:35 15 OCT 2001 380 (ME) MECHANICAL FI 9 10/25/01 90 APPROVED BLD19 10/25/01 COMMENTS: REQ DUE TO FAILED INSP 12:45:56 15 OCT 2001 480 (PL) PLUMBING FINA 9 10/25/01 81 DISAPPROVED BLD19 10/25/01 COMMENTS: NEED WATER HOOKED & BACK FLO PREVENTER HOOKED UP REQ DUE TO FAILED INSP 12:46:14 15 OCT 2001 800 (ZC) ADDRESS FINAL 9 10/25/01 90 APPROVED BLD18 10/25/01 803 (ZC) PARKING/HANDI 9 10/25/01 90 APPROVED BLD18 10/25/01 700 (FM) FIRE DEPARTME 9 10/29/01 81 DISAPPROVED FRM09 10/30/01 COMMENTS: NOT READY LINDA S T. L U C I E C 0 U N T Y 2300 Virginia Avenue Ft. Pierce, Florida 34982 Growth Management Division PERMIT Permit #: 21010464 Type: BUILDING COMMERCIAL Issued: 05/01/01 Job Location: 4590 OLEANDER AVE / FT PIERCE Jurisdiction: ST LUCIE COUNTY Lot: P8 Blk: Subdiv: WHITE CITY S/D Parcel: 3403-502-0023-000/4 Owner's Name: FT PIERCE LODGE #87, Project: Page 7 Insp Area 1 Master Nbr. 21010464 Flood: X Elev: Job Description: NEW COMMERCIAL BUILDING - FT PIERCE MASONIC L INSPECTIONS - For Requests, Call: (561) 462-1261 REINSPECTION FEES REQUIRED: 4 REINSPECTION FEES PAID: 4 Req Description Pr Date Res Description Insp Date 808 (ZC) LANDSCAPING/T 9 10/25/01 92 ACCEPTED AS NOTED PLN10 10/31/01 COMMENTS: 6FT WAX MYRLE NEEDS TO BE REPLACED FOR THE BUFFER BETWEEN THE LODGE AND THE RESIDENCE 700 (FM) FIRE DEPARTME 9 11/01/01 81 DISAPPROVED GTM24 11/05/01 COMMENTS: DIDN'T GO OUT THERE, NO WATER HOOKED UP.. 11/5/01 MLE LINDA CALLED ME - SAID DEREK WAS GOING OUT THERE TODAY REQ ADDED DUE TO FAILED INSP 10:38:12 30 OCT 2001 804 (ZC) DRIVEWAY FINA 9 11/05/01 90 APPROVED ENG09 11/05/01 700 (FM) FIRE DEPARTME 9 11/16/01 90 APPROVED FRM09 11/16/01 COMMENTS: REQ ADDED DUE TO FAILED INSP 08:45:26 05 NOV 2001 480 (PL) PLUMBING FINA 9 11/16/01 90 APPROVED BLD05 11/19/01 COMMENTS: maryland 863-467-2541 REQ ADDED DUE TO FAILED INSP 09:13:31 02 NOV 2001