MARCH 19, 2001
DENNIS GRIM, BUILDING OFFICIAL
ST. LUCIE COUNTY PUBLIC WORKS
Z300 VIRGINIA AVENUE
FT. PIERCE, FLORIDA 34982
REFERENCE BUILDING PERMIT N( �21WO464
G. Mack Worley, Sr.
President
Mack ( Hoot) Worley
Vice Tresident
DEAR MR. GRIM,
t PLEASE, FIND THE COMMENTS AND CLARIFICATION:; WEGIUESTED BY MR.
JEFFERY VANORE (FAX 3/12/01) AS FOLLOWS:
�. UNDER5TOOD. s
2. UNDERSTOOD,
3. CORRECTED DESIGN CcR*7LFICATTEON ATTACHED. PLEASE EXCUSE THE
TYPO.
4. AS TO SIGN LOCATION, PLEASE, SEE NOTE FLOOR—::-.. AN, SHT. 2 OF 10.
AS TO OCCUPANT CONTENT, THE LAST SENTENCE OF SBC 403.1.2.2
STATES THAT NUMBER IS TO BE, DETERMINED BY THE BUILDING
DEPARTMENT.
# pjoza3l lwt-. .
S� &wpa�.
CG 0034074
�' �44�0'*
5. SEE FRAMING PLAN, SHT. 10 OF 10.
-- 6. SEE INTERIOR FRAMING DETAIL, SHT.7 OF 10.
7. SEE GENERAL NOTES, SHT, 1 OF 10.
8, INTERIOR FINISH IS TO Be AS STATED TYPICAL WALL SECTION, 5HT. 7
- OF 10. THIS COMPLIES WITH SBC 803.3.
1 9. COMMON PATH OF TRAVEL FOR THE SOCIAL ROOM 115 24'-6".
COMMON PATH OF TRAVEL FOR THE ASSEMBLY ROOM IS.70'-4". BOTH
ARE WITHIN THE 75'-0" NOT TO EXCEED AS STATED:_IN SBC 1004.1.3.
THREE EXIT DOORS ARE PLANNED. MEASURED IN At STRAIGHT LINE
j FROM THE FRONT EXIT DOOR TO THE SOCIAL ROOM.EXIT.DOOR IT IS
53'-0". ONE HALF OF THE LENGTH OF THE MAXIMUk", OVERALL
DIAGONAL DIMENSION OF THE BUILDING IS
WITH 58C 1004.104.
10, PLEASE,...NOTE THAT A 12' x 24' CONCRETE. SLAB HA . BEEN_ ADDED. AT
- THE KITCHEN EXIT..DOOR AND THE"SOCIAL RO"OM'EXIT'D'OOR:-` THI5
SLAB WILL Be lf" BELOW THE FINISH FLOOR ELEVATION. THIS
COMPLIES WITH SBC 1004.3 AND ADA REQUIREMENTS,
11. PLEASE, SEE SHT. 1 OF 10, SECTION 5-5.
12. PLEASE, SEE ELECTRICAL PLAN, SHT. 6 OF 10.
13. ALTHOUGH THE TOTAL SQUARE FOOTAGE OF THE PROPOSED
BUILDING WOULD ACCOMMODATE A TOTAL OCCUPANCY IN EXCESS .OF
500, THE MASONS, DUE TO THE SPACE NEEDED FOR THEIR
CEREMONIES, WOULD ANTICIPATE NO MORE THAN 50 TO 60
PARTICIPANTS. OUR DESIGN CRITERIA IS NO MGC.E THAN 100 TOTAL
- OCCUPANCY. PLEASE, FEEL FREE TO LIMIT THE TOTAL OCCUPANCY
BASED ON WHAT THE EXIT DOORS WILL ALLOW AS THE PLAN IS
SUBMITTED, RATHER THAN REQUIRING LARGER O % :kODITIONAL
EXIT DOORS.
14, SEE MAKEUP AIR DUCTS, SHT. 8 OF 10.
15. SEE NOTE, 5HT: -2 OF 10,
00 0034074
16,_ SEE ELECTRICAL PLAN, SHT. 6 OF 10, v-t
17. ROOFING PRODUCT DATA, ATTACHED.
18. WINDOW AND EXTERIOR DOOR PRODUCT DATA, A'71 TACHED.
19. SEE FOUNDATION PLAN, SHT. 9 OF 10.
-20. TRUSS LAYOUT AND ENGINEERING WITH ENGINEERS SIGNATURE,
ATTACHED.
21. SEE GENERAL NOTES, SHT. 1 OF 10.
22. • SEE TRUSS ENGINEERING, ATTACHED.
23. SEE ATTIC ACCESS IN KITCHEN, 5HT. 2 OF 10.
24. SEE GENERAL NOTES, 5HT. 1 OF 10.
25. SEE DETAIL AT WINDOWS AND DETAIL AT EXTERIOR DOORS, 5HT. 7
OF 10.
26. SEE NOTE AND FLOOR PLAN, SHT 2 OF 10.
27. RESPECTFULLY REQUEST A MEETIN&1' tTrg/A. GRIM CONCERNING
THIS ITEM. Fi,,:,e.8 6472
SINCERELY,
tic
MACK WORLEY, CONTR CTOR
CONTRAC TOR
MAR 19 2001
107 STi 17it: St2e4
. . - m_ia., 34974
MOSELEY :O" INS, P.E.
ENGINEER