Loading...
HomeMy WebLinkAboutSeptic SystemBENCHMARK CENTER OF OLEANDER A ASSUMED ELEVATION 37. IRRIUM I IUN YYLLL L- - - - - - - - - - FIELD BK. FILBK./PG. REF. / 00-1:18SEP.DWG CULPI PPER & TERPE NING.INC. CONSULTING ENGINEERS LAND SURVEYORS 2980,SOUTH 25th STREET FORT PIERCE, FLORIDA 34981 (561) 464-3537 MAY 2 4 29M St. Lucie County Public Works — R E V I S 1 0 N S— BLDG. 15' SOUTH, REVISED LOCATION O I NOTES 1. All construction, materials, installation and testing shall conform to the standards and requirements of the St. Lucie County Health Department and On -Site Sewage Disposal System Permit No. _--_----- 2. Sewer force main shall be Schedule 40 PVC and have a minimum of 30" cover unless otherwise directed by the Engineer. Backfill shall be compacted to 95% density in accordance with AASHTO T-180. 3. Drainfield shall have a 2" PVC supply line from the dosing tank. 4. The septic tank shall have an effective capacity of 900 gallons and shall be constructed in accordance with Florida Statutes Chapter 1OD-6.55, "Construction Materials for Treatment Receptacles". Installation of the tank shall be in accordance with Chapter 1OD-6.46, "Location end Installation". 5. Effluent pumping chamber (dosing -tank) shall be either precast concrete or fiberglass with a 24"x24" 'aluminum access hatch (with locking hasp). Any deviation from the dosing tank shown shall be approved by the Engineer and will affect the float level settings as specified herein. 6. The pump for the dosing tank shall be submersible,single phase, with a solids handing capability of 1/2" and capable of pumping 25 gallons per minute at 10 feet of Total Dynamic Head. Pumps selected by the Contractor shall be submitted to the Engineer for approval prior to installation. EXISTING GROUND EL. 37.4t z INFLUENT LINE 900 GALLON SEPTIC TANK 7. Control system for the dosing tank shall be a NEMA approved control panel and shall be equipped with the following items at a minimum: Pump -off, pump -on, high level audio alarm, run light for pump and surge protector. B. Drainfield shall be constructed and installed in accordance with Florida Statutes Chapter 1OD-6.56, "Construction Standards for Drainfield Systems". 9. The area under the-drainfield(s) and one foot outside of the drainfield(s) area is required to be excavated until reaching slightly limited soil, with a minimum depth of excavation being 72" and bockfilled with clean granular sand.The excavation shall be inspected by the Health Department prior to backfilling. The septic tank contractor shall be responsible for the full depth of excavation required and should ascertain such depth prior to proceeding or otherwise contractually address with the owner any excess excavation beyond the minimum depth of 72". 5' MIN. EL. 40.15 MIN. i � N CLEAN, COARSE -� SAND FILL z ( 4" PERFORATED CORRUGATED POLYETHELENE TUBING (TYP) —_----- N INVERT 38,9 DRAINFIELD ROCK WATER TABLE EL 36.` I / PER 10D-6.056(4)(C) �- - -- WHERE MODERATELY LIMITED OR SEVERLY 0 - — LIMITED'SOILS ARE ENCOUNTERED z - I REPLACE WITH SLIGHTLY LIMITED SOIL. a I � ^x I I w I -------------------------------- NOTES: 1) TOP AND SIDES OF DRAINFIELD TO BE PROVIDED WITH MIRAFi FILTER FABRIC OR HEALTH DEPARTMENT APPROVED EQUAL. 2) SOD ENTIRE TOP AND SIDESLOPES OF DRAINFIELD AREA. 3) NOTIFY ENGINEER MIN. 24 HOURS PRIOR TO EXCAVATION AND CONSTRUCTION FOR INSPECTION & CERTIFICATION OF INSTALLATION. D A I N Ir I I. I_D DETAIL ST. LUCIE COUNTY HEALTH DEPT. ENVIRONMENTAL HEALTH SFCTION N.T.S. SITE PLAN APPROVED FOR CONSTRU¢TION SUPERCEDES ALL PREVIOUS SITE PLANS OSDS # REVIEWER TO CONTROL PANEL DOSING TANK AAWMW 2" PVC PIPE TO DRAINFIELD STORAGE CAPACITY FLOAT 2ZZZCONTROLS SCUM SKIMMER ALARM L CLARIFIED I PUMP ON EFFLUENT-r _rSLUDGE ._ _ PUMP OFF PUMP SEPTIC TANK AND DOSING TANK DETAIL r Ft. Pierce MASONIC L®LCGE SEPTIC SYSTEM 1-1 DATE: 12- 21- 2000 HORIZ. VERT. SCALE: 1"= 40' SCALE: JOB No. 00-118 SHEET 1 OF 1 Awa-N--,