Loading...
HomeMy WebLinkAboutAPPROVED Extreme.1NailStrip 8/20/2020 Florida Building Code Online Business & Professional t SCIS Kane L"In User R"dtrathon Mot rogics Submit Surcharge Stars S Facts publhcathans Contact us SOS Site Map Links Search ft"j1 UM:Ne c us" val dbpr LASER:Pu6rk I1ser �•-a�,,r'...:�: j _ a P'oDut7 or a12011ca'Al afar,- agp r 3':r._,•>APPAcettan Detalt FL Jt FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v.date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC 1I 1 Address/Phone/Email 2160 SW Poma Dnve tt nQS 1 S1 Palm City, FL 34990 (772)872-8034 Rvalidation@yahoo.corn Authorized Signature Richard McKuhen Mvalidapon@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 nchard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory !Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 0412212024 Validated By Zachary R. Priest, P.E. Validation Checklist- Hardcopy Received Certificate of Independence y 7022 R 7 C a rs :7021.- CRIW ssr= Referenced Standard and Year(of Standard) Standard Ywar TAS 125 2003 UL1897 2022 UL580 2006 Equivalence of Product Standards Certified By Sections from the Code https:l/www.floridabuilcllng.orglprlpr_app_dU.aspx?param=wGEVXGwtDgv2aBopHpOQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 113 8/20/2020 Florida Building Code Online Product Approval Method Method I Option b Date Submitted 08/18/2017 Date Validated 0812 5/201 7 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL rX Model,Number or Name Description 17022.1 1 -"SV Crimp" (R6) 26 Gauge steel, 3/8"rib height,24"wide lapped roof panel mechanically attached to 15/32"plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use In HVHZ: No 7i 2 Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Repots Other: Refer to evaluation report for conditions Install the . . 222 1_5 y-�R _ ,pcf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions 17022.2 2 - "5V Crimp" (R6) 0,032"Aluminum, 3/8" Rtb height,21"wide lapped roof panel, mechanically attached to 15/32"plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No _ ., _ayMr "±032 ALJW -,, Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other Refer to evaluation report for conditions.Instali the _ 11;_ 032 AL W ss,aj' assembly in compliance with the installation method listed in Created by independent Third Party:Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions - 17022.3 3-"1,5" Mechanical Seam" (R5) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with Clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: Na '7^ R: Il F. 3 M , _._--.- Approved for use outside HVHZ:Yes Ig _2 9a SiAS2` Impact Resistant: No Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Other:Refer to evaluation report for conditions and limitations Evaluation Reports of use.Install the assembly in compliance with the installation method listed in this report and applicable code sections of cerr 3 55_ FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.4 4-"1.5"Mechanical Seam"(RS) 1.5"rib height, 16"wide, 0,032"aluminum,standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits Of Use Installation Instructions Approved for use In HVHZ: Na .1_ MECHANC(a1 AM Approved for use outside HVHZ:Yes qV ti•N. "_i3 Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Othar:Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly in compliance with the installation rL:7022 R7 AE fi I70.22 4 MELHtkNLIAL SEAM method listed in this report and applicable code sections of ss•�-Cf FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party. Yes 17022.5 5-"1 in. Nail Strip"(RS) 1"rib height, 16'wide, 26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use In HVHZ: No :'�2:; :Z7_ii r.. :- Approved for use outside HVHZ:Yes Verrfied By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations i. - of use. Install the assembly in compliance with the installation Created by Independent Third Party Yes https:l/www.flondabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpOOe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 2/3 8120/2020 Florida Building Code Online method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions, 17022.6 6-"1 in. Nail SEnp" (RS) 1"nb height, 16'wide,0.032"aluminum,standing seam roof panel mechanically attached to attached to 15/32"plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No :._?'. !I r a =! Approved for use outside HVHZ:Yes �� s Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and limitations Evaluation Reports of use.Install the assembly in compliance with the installation 7 y method listed in this report and applicable code sections of " ssr i` FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.7 7- "1.5 in. Nail Stnp" (115) 1.5"rtb height, 19"wide,26 gauge steel, standing seam roof panel mechanically attached to 15132"plywood or wood deck with fasteners. Limits of Use Instillation Instructions Approved for use In HVHZ: No - : . z Nall St-r Z6GA 55r pq! Approved for use outside HVHZ:Yes Verified By: Locke Bowdenr P.E.49704 Impact Resistant: No Created by Independent Third Party- Yes Design Pressure:+NIA/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and limitations -. . of use. Install the assembly in compliance with the installation treated by Independent Third Party: Yes method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation Instructions. 17022.8 8-"EMAX Rib"(R5) 29 gauge steel, lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No :> —--_=s6 ."^?`!'t spy Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E.49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A1-Table A Evaluation Reports other: Refer to evaluation report for conditions and limitations of use.Install the assembly in compliance with the Installation Created by Independent Third Party, Yes method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 9 "PBR MAX" (R5) 26 gauge steel, lapped roof panel mechanically attached to 15/32'plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No -L"74« �iI '-- ` LB .IE. Approved for use outside HVHZ:Yes Venfted By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Patty: Yes Design Pressure:+N/A/table A Evaluation Reports Other. Refer to evaluation report for conditions and limitations 1_ ; ,111?2 9 i'BR RIB ssi 0.4' of use. Install the assembly in compliance with the installation Created by Independent Third Party:Yes method listed In this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Contact us 2601 Blair Stone Road,Tahahassee FL 32399 Phone:950-467-1924 The State of Florida is an WEED employer COW=2007-2013 State of Florida Pnvagt 5tjjCMrn_t :ACce551bihty SCDtemenl Retund statement Linder Ronda low,email addresses are public records.if you do not want your a-maii address released in response to a public-recortts request,do not send electronic mail to this enpty.instead,contact the office by phone or by traditional mail.If you have any Questions,please contact a50 481.1355.'Pursuant to Section 455.275(1). Ronda Statutes,effective October L.2012,acensees licensed under Chapter 455,F.S-mu5t provide the Department with an email address if they have one.The emall5 provided may be used for ohioal communicaGnn with the licensee riowever email addresses are pueiic record it you do not wish m supply a personal address.olease provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here Product Approwl Acmpts: ®® ® ED Safe https:llwww.fioridatwilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQeSrMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3de/aid 313 1 Product . . 2160 SW Poma Drive Palm City, FL 34990 772 872-8034 Florida Product Approval # 20378.2 1" Nailstrip 26GA Steel NON HVHZ Compliant with Florida Building Code 2017 (6" ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec. 1507.4.2 Yield strength: 40ksi: Attached to Wood Deck with screws. 16" Coverage Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood screw to penetrate 3/16" thru 15/32" min. plywood deck Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive along male flange the full length of panel. Underlayment: To be compliant with FBC Sec. 1507 Slope: Shall be in compliance with FBC Sec. 1507. 1.1 Install Details: Table A Allowable Loads METHOD 2 main field METHOD 2 perimeter DESIGN PRESSURE* -69.25 PSF -121.75 PSF FASTENER SPACING-ALONG ROWS 6" O.C. 6" O.C. FASTENER SIZE: #10 #10 ADHEISIVE: NOT REQUIRED 3/8" BEAD (refer to install details) Reference Data: HURRICANE TEST LABORATORY, L.L.C. #TST ID: 1527 Report#:0223-0313-02 TAS125-03(UL 580-061UL 1897-041 J Report#: 0223-1015-06 TAS125-03(UL 580-061UL 18-97041� EQUIVALENCY:UL 1897-04 tS EQUIVALENT TO UL 1897.12 TEST STANDARD *DESIGN PRESSURE MARGIN OF SAFETY 2:1 Certificate of Independence: Locke Bowden, P.E.does not have,not will acquire a financial interest`�antldb4Mosny,manufacturing or distributing products under this evaluation. �,• C ✓`fit: �� Locke Bowden,P.E.is not owned,operated,or controlled by any�Orr�any,inarlufecture�;6Gdistributing products under this report. v v r Wz� s CJ E` zi . FL 20378.2 1 A Nail Strip (26GA Steel), 16" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code(FBC)2017 6th ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-13 4. Engineering analysis for"project specific approval by local authorities wfjurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 601 ed., Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report. Fastener #tU Panrae+lead Saerr tJa�'Root Parma — --- --, r. I eo or I � cm6w f 15I3�"111bod Deck ffi akmg male rib {ReferiDTabW A) 16"o-c. - � ilNood Deck -- **gral Snap Lock Searn Adhesive Apply 3ar head Boshk Sealant enlire length of panel ,a"male#1 mW J.. _._#lox ancalPc4Head Screw