HomeMy WebLinkAboutElevations & Plans 11.23.20KEY MAP 3 A3.1 BUILDING "A" - FLOOR PLAN III N SCALE : NTS SCALE: 1/8" = V-0" LU a Q U z J WALL LEGEND NEW 8" CMU WALLS WITH CORE FILLED FOAM ON EXTERIOR WALLS ONLY. INTERIOR FINISH SHALL UNFINISHED BLOCK. EXTERIOR FINISH SHALL BE SMOOTH FINISH STUCCO WHERE APPLICABLE (RE: ELEVATIONS). SEE WALL TYPES. PARTITION WALLS OF METAL STUDS @ 16" O.C. W/ CORRUGATED METAL WALL PANELS BOTH SIDES. SEE WALL TYPES & SECTIONS. :, M NEW MIN. 3-5/8" 22 GA. METAL STUDS @ 16" O.C. W/ 5/8" THK GYPSUM WALLBOARD FINISH EACH SIDE (PAINTED). PROVIDE MIN. R-11 BATT INSULATION IN ALL WALLS SURROUNDING BATHROOMS & MECHANICAL ROOMS. SEE WALL TYPES 72'-0" 12'-0" 6'-4" 11'-8" 12'-0" 12'-0" 12'-0" 11'-8" 6'-4" — — — — O — — — — O — — — — O — — — — O — — — — O — — — — O STORAGE B-8 STORAGE B-9 STORAGE B-10 STORAGE B-11 STORAGE B-12 o STORAGE B-13ICU-2 O CL12'-0" L------- F -1 I LJ STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE B-7 B-6 B-5 B-4 B-3 B-2 B-1 O — — — — O — — — — O — — — — O — — — — O — — — — O — — — — O — — — - - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 6'-4" 11'-8" 12'-0" 12'-0" 12'-0" 12'-0" 11'-8" 6'-4" 84'-0" N BUILDING "B" - FLOOR PLAN SCALE: 1/8" = V-0" 144'-0" (BUILDING OVERALL) 6'-4" 4,11'-8" (L12'-0" (L12'-0" (L12'-0" (L12'-0" 5'-811 811 5'-811 (L12'-0" (L 12'-0" 12'-0" 12'-0" 11'-8" 6'-4" STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE No STORAGE STORAGE STORAGE STORAGE C-13 C-14 C-15 C-16 C-17 C-18 C-19 C-20 C-21 C-22 C-23 C-24 (L12'-0" (TYP.) CL12'-0" (TYP. ) F,-I r-1 I I LJ I LJ STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE STORAGE C-12 C-11 C-10 C-9 C-8 C-7 C-6 C-5 C-4 C-3 C-2 C-1 O O O O O O O O O O O O -------------------------------------- --- -------------------------------------- --- 6'-4" 11'-8" 12'-0" 12'-0" 12'-0" 12'-0" 5'-8" 8" 5'-8" 12'-0" 12'-0" 12'-0" 12'-0" 11'-8" 6'-4" 144'-0" BUILDING "C" - FLOOR PLAN LU U Ln z Q J 211 N 0 6 N 0 0 I• SCALE: 1/8" = 1'-0" `) N Application: SPMN-8201925592 C a1 + T y Ln +; I a-.-i C M N— C a) w = U a) i o i C L >L C1 O O 'In> Y Ul Y O —C In M 'n a) V 'i C a O VI C a) O C C N O L `°��� 3u L L C Q O IZ— C + N J-+ L T n3 M 3 a rn 3- ns .3 V• V • N Ln L •L 'L L C O +.� � 7 � L a) 0 6 o f o T C c 5 'n o ^ C: M 3 } U U U @ fo� U CU C L L Q ou<m E02) U co C ON -a — _O (n J LL N N a)t N '0 Co r— L + co Cz N O 0 C5 LLJ w E 0 O O N U � U U i c6 W O •' Ln 4J rr^^ L 0 � M VJ C: (a U J U- C: lD O� p O U M CO O � O 00 0� r- Ln ru O Rev. # Date �L - Project Number 19-0502 Status Site Plan Approval Issue date 16-Aug-2019 Sheet A2ml Floor Plans Buildings A, B, C 24'-0" O.C. (TYP.) 3 - BUILDING "F" KEY MAP 1 - BUILDING "D" — — — — — — r1� �0- L — —I 12'-0" SCALE: 1/8" = V-0" N N O O O O I SCALE : NTS 12'-0" N 12'-0" 12'-0" 12'-0" 12'-0" 156'-0" 12'-0" WALL LEGEND NEW 8" CMU WALLS WITH CORE FILLED FOAM ON EXTERIOR WALLS ONLY. INTERIOR FINISH SHALL UNFINISHED BLOCK. EXTERIOR FINISH SHALL BE SMOOTH FINISH STUCCO WHERE APPLICABLE (RE: ELEVATIONS). SEE WALL TYPES. PARTITION WALLS OF METAL STUDS @ 16" O.C. W/ CORRUGATED METAL WALL PANELS BOTH SIDES. SEE WALL TYPES & SECTIONS. 12'-0" 12'-0" 12'-0" NEW MIN. 3-5/8" 22 GA. METAL STUDS @ 16" O.C. W/ 5/8" THK GYPSUM WALLBOARD FINISH EACH SIDE (PAINTED). PROVIDE MIN. R-11 BATT INSULATION IN ALL WALLS SURROUNDING BATHROOMS & MECHANICAL ROOMS. SEE WALL TYPES 12'-0" SCALE: 1/8" = V-0" 1 2 - BUILDING "E" SCALE: 1/8" = V-0" / N Application: SPMN-8201925592 C a1 + T y w a; I aL.-i C M N— C a) w = U L o M L C L fu L a� O O n Y ++ � In a N U 'i 7 a U1 C a) N C y O L L L L C Q O O C +� 7 n3 M 3 a rn 3 ns .3 V• V • 'L •L L C O as 7 L a) 0 6 o L o T u L C L n rn a-' o ^ M 3 }' U U V U p ��� a°'� U �Y/Lpfo@L C L L Q ou<m Eow N M, - U O -a — U) J N _O LL N a) N of Co r— L + co Cz N O OU C5 LLJ w E 0 O O N U � U U c6 ro L O a) N 4J rr^^ L 0 M VJ C U- C: lD U O� p O ifa U (a CO O O m r_ Ln fu O n Ln Rev. # Date �L— - Project Number 19-0502 Status Site Plan Approval Issue date 16-Aug-2019 Sheet A2n2 Floor Plans Buildings D,E,F 1 - SOUTH ELEVATION (CUSTOMER BUILDING) PLATE HEIC 8'-0" _ PLATE HEIC 0'_0" T.O. SLAB 3 -NORTH ELEVATION (CUSTOMER BUILDING) 6 - NORTHEAST ELEVATION (PRIMARY FACADE) 0 COLOR SCHEDULE SHERWIN WILLIAMS' NEUTRALS COLOR PALETTE COLOR MARK DESCRIPTION ROOF SW6247 COLOR: SILVER ROOFING COLOR COLOR: SW6247 - "KRYPTON" COLOR: SW7573 - "EAGLET BEIGE" COLOR: SW7005 - "PURE WHITE" Q Q SW7573 Q SW7005 Q GENERAL NOTES: 1. Refer to official exterior color palette samples from the manufacturer. They are shown herein for purely representation purposes only. 2. Prep surfaces before application according to pain supplier recommendations. 3. Paint all surfaces of all materials including electrical conduits, j-boxes and f.e. cabinets. 4. Provide field samples of each color for approval prior to full buy-out and installation. cqdmn I I IL --- SCALE: 1/8" = 1'-0" 12'-0" PLATE HEIGHT PLATE HEIGHT SOFT TURTLE-FRIEDLY BACKLIT CHANNEL LETTERS 40 S.F. WALL SIGN (54 S.F. MAX) „A, SIGN AREA CALCULATION §9.02.01 SIGNS OTHER THAN BILLBOARDS TOTAL WALL SIGN MAY EQUAL UP TO 10% OF TOTAL WALL FACE AREA FRONTING MAIN STREET WALL FACE: 541 S.F. * .10 = 54.1 S.F. 8 - WALL SIGN SCALE: 1/4" = 1'-0" 2 - EAST ELEVATION (CUSTOMER ENTRANCE) SCALE: 1/8" = 1'-0" METAL ROOF ROOF SW6247 24'-0" (TYP.) SW7005 ri I I I I I I SW7573 WIDTH PER FLOOR PLANS 4 -TYPICAL STORAGE FACADE (BACKSIDE) COMMUNITY ARCHITECTURAL STANDARDS I Unincorporated St. Lucie Countv 7.10.24 - Community Architectural Standards: §7.10.24C I Interim Design Standards: 2.A. Building Orientation: The main entrances(s) of a building shall be oriented toward the primary street front. 7.10.24D.1 I Facade Design: A. Prohibited Facade Features: Large, blank, unarticulated walls Corrugated metal siding Plastic siding, laminates Irregular modernistic window shapes Imitation rockwork Corrugated fiberglass B. Articulation: • Facade design shall appear as indicated on the approved drawing. Provide varying wall offsets and other architectural features to create horizontal and vertical building articulation. A minimum wall offset of 5 five feet is required to achieve horizontal facade articulation. A minimum vertical distance of two feet between facade elements is required to achieve vertical articulation. • Out Parcels --All facades of buildings located on out parcels shall be considered primary facades and shall therefore require facade and roof articulation on all sides. Architectural, site, and landscaping design elements shall be consistent with the design elements of the primary building with • Color --Soft, muted tones shall be used. A building shall have no more than three colors on all facades. C. Roof Design: 1. Sloped Roofs --Roof height shall not exceed the average height of the supporting walls. The average slope shall be greater or equal than one foot of vertical rise for every three feet of horizontal run. Proposed building shall incorporate at least two roof elements or features: a. Three or more roof slope planes per primary facade. b. An additional vertical change in roof height (minimum two -foot change in elevation). C. Dormers or additional roof elements facing primary street frontage. d. A porch, portion, arcade, or other similar element located at the main building entrance(s). F. Architectural Style: Florida Vernacular Requires 5 elements and shall illustrate the elements on the required elevation drawings: Predominantly vertical, rectangular, windows, Clear Glass Windows Bahama Shutters Cupola Dormer Square Columns o KEYED NOTES 1. Peaked Roof Forms 5. Stucco Trim Relief Work 2. Windows 6. Raised Roof Feature Over Customer Entrance 3. Decorative Light Fixtures (Amber) 7. Cupola 4. Painted, Smooth Stucco Finish 8. Bahama Shutters 1 71 12'-0" PLATE 6" HEIGHT O.H. 4 0'-0" T.O. SLAB 1 51 12 1 1I 5 METAL ROOF ROOF SMOOTH y STUCCO 30'-0" SW6247 FENCE; RE: CIVIL 24'-0" CUPOLA BEARING 15'-0" 6 PLATE HEIGHT O.H. SW7005 SW7573 0'-0" T.O. SLAB 5 -NORTH ELEVATION (PRIMARY FACADE) SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" Application: SPMN-8201925592 C: (1) >, y v N CU MULCU w = f c i O M C O fo >L O O 'an, > a20 Y 10W-_� M�� O. O VI C N U = O Z, �3u L L C N Q 3 c M v g 'L •� L �v��o=o � (0 0-0 S�v 3 } U U U O Y fl_ fo@ U CU L f L fo � mt :4-U ON _2) U) J LL N N >Co N r. L + CZN 0 '� Co o (D LLJ ( ° E 0 + O N U � U i W O •' Ln 4J rr^^ L 0 M VJ C: (a U J U_ � l0 O� p O U fa (a CO O -J O N � O cn (0 Ln L M 0 a E Q� .-. coM �� 1­0 Rev. # Date 1 17-Oct-2019 Development Review Project Number 19-0502 Status Site Plan Approval Issue date 16-Aug-2019 Sheet A3ml Exterior Elevations