Loading...
HomeMy WebLinkAboutBlack and White0020brtmf"- -Az 191/,031� PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 November 20, 2020 Re: Williams Garage REMED 2306 N. 49th St Ft. Pierce, Florida Nov 2 3 2020 Permitting Department St. Lucie County To Whom It May Concern: Our office has personally inspected the CBS wall damaged by the front end loader and recommend the contractor to insure the CBS is level and fill all cells a minimum of 3 feet each way from the corner W/ 3000 psi concrete W/ vertical reinforcement to remain as is per plan at the referenced address and find that all work meets the FBC and FRC 2017, 6th Edition and our engineering requirements. Thank you for your attention to this matter. Sincerely: PAUL E CH INC. Paul We ch, P.E. Fla. Reg. No. 29945 PW:ns