HomeMy WebLinkAboutBlowerdoor_11242020095739Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, F134982
Phone:772-462-2165 Fax:772-462.6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
Date:
Contractor: Permit #;
Job Address: �2
Constructioiil:
New Construction — Complete
d ) Existing — Af#er Addition
n
House Infiltration Test Results
CFM (50) - 'Z SLC Climate ,Zone 2
Volume = Test Date: - Zi/ 7a 2 c
ACH (50) = CFM (50) x 60 / Volume
Passing results must be & ACH (S0) or Tess Mechanical Ventilation required less than 3 ACH
{Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not ex
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall
blower door at a pressure of 0.2 inches w. ceeding 7 air changes per
g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an
approved third party. A written report of the results of the provided to the code official, test shall be signed by the party conducting'the test and
at any time after
thermal envelope, f all Testing shall be performed creation o penetrations of he building
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with
pressure of 0.2 inch w. C. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, E erower doorgy Conservation
at a
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Sect
Testin Com an ion M1507,3,
Company Name: (�
n !O Address: d 7 C
G OCJ UV�
1 hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accorda with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name:
I
-------------
License/Certification #: S� %�