HomeMy WebLinkAboutEnergy Code, M Component Performance Method for Commercial Buildings Form 400B-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 PROJECT NAME -APOSTLE CHURCH OF DELIVERAN PERMITTING OFFICE: ADDRESS: 1505 N. 43RD ST. _Fort Pierce ------------ ----------------- _FORT PIERCE, FL__ _ CLIMATE ZONE: _6____N_ OWNER: _ -CONGREGATION PERMIT NO: ------------- AGENT: ____________ JURISDICTION NO: 661100 BUILDING TYPE: -_Service Establishments_____ CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building__________ CONDITIONED FLOOR AREA: _8000_________ NUMBER OF ZONES: 4 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5___________�_____ COMPLIANCE CALCULATION: METHOD B DESIGN CRITERIA RESULT ------ ----------------- ENVELOPE PERFORMANCE ------ 34.29 -------- 64.99 PASSES . OTHER ENVELOPE REQUIREMENTS PASSES LIGHTING INTERIOR LIGHTING 4810.00 12588.30 PASSES " EXTERIOR LIGHTING 206.00 392.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER 10.00 10.00 PASSES 2. SEER 10.00 10.00 PASSES 3. SEER 10.00 10.00 PASSES 4. SEER 10.00 10.00 PASSES HEATING EQUIPMENT 1. Et 0.88 N/A 2. Et 0.88 N/A 3. Et 0.88 N/A 4. Et 0.88 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Conditioned Space 6.00 0.00 N/A 2. Conditioned Space 6.00 0.00 N/A 3. Conditioned Space 6.00 0.00 N/A 4. Conditioned Space 6.00 0.00 N/A REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT 1. EF 0.88 0.54 PASSES PIPING INSULATION REQUIREMENTS 1. Non -Circulating 1.00 0.62 PASSES ---------------------------------------------------------------------------- COMPLIANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifica- specifications covered by this calcu- tions covered by this calculation lation are in compliance with the indicates compliance with the F1.0rida Energy Efficiency Code. PREPARED BY : __J-4(--X_Q'__ DATE - __y - ------ ---------------- ---- r I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER/AGENT: DATE -__ ------ Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. BUILDING OFFICIAL: DATE: I hereby certify(*) that the system design is in compliance with the Florida Energy Ffficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHITECT ._ _ _ _ _ _________ MECHANICAL__`____='----------------------- PLUMBING----------------------------------------------------------------- ELECTRICAL: ----------------------------------------------------------------- LIGHTING (*) Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLIANCE CHECK *01.------GLAZING--ZONE 1----------------------------------------------�-v- Elevation "--------- Type --------------- U SC VLT Shading ---- ---- ---- -------------- Krea(Sgft) ----------I West Commercial 1.31 .6 .7 None 601 South Commercial 1.31 .6 .7 None 241 North Commercial 1.31 .6 .7 None 1261 East Commercial 1.31 .6 .7 None 601 Total Glass Area in Zone 1 = 2701 401; ------ GLAZING --ZONE 2------------------------------------------------ v- Elevation Type --------------- U SC VLT Shading ---- ---- ---- -------------- Area(Sgft)l ---------- --------- East Commercial 1.31 .59 .6 Continuous Ove 5401 'North Commercial 1.31 .59 .6 Continuous Ove 201 South Commercial 1.31 .59 .6 Continuous Ove 201 Total Glass Area in Zone 2 = 5801 401.------GLAZING--ZONE 3------------------------------------- ---v- Elevation Type U SC VLT Shading ---- ---- ---- -------------- Area(Sgft)l ---------- --------- South --------------- Commercial 1.31 .59 .6 Continuous Ove 11 North Commercial 1.31 .59 .6 Continuous Ove 201 Total Glass Area in Zone 3 = 211 401.------GLAZING--ZONE 4------------------------------------------------ v- Eievation Type U SC VLT Shading ---- ---- ---- -------------- Area(Sgft)l ----------I --------- South --------------- Commercial 1:31 .59 .6 Continuous Ove 401 West Commercial 1.31 .59 .6 Continuous Ove 401 North Commercial 1.31 .59 .6 Continuous Ove 321 Total Glass Area in Zone 4 = 1121 Total Glass Area = 9831 402.------WALLS--ZONE 1------------------------------------------------ I --- Elevation Type U Insul R ----- ------- Gross(Sgft)l -----------I --------- North -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 6721 East 81-CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 8401 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 7841 West 811CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 6 8401 Total Wall Area in Zone 1 = 31361 402.------WALLS--ZONE 2----------------------- -------------------------I--- Elevation Type U Insul R ----- ------- Gross(Sgft)l -----------I =-------- West -------------------------------- 811CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 3601 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 1501 East 81-CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 6 3601 North 811CMU/3/411ISO Btwn 24"oc/5/8"Gyp 0.151 6 1501 Total Wall Area in Zone 2 = 10201 402.------WALLS--ZONE 3 ------------------------------------------------ I --- Elevation Type U Insul R ----- ------- Gross(Sgft)l -----------I --------- West -------------------------------- 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 4321 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 5521 East 81-CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 4801 North 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 4321 Total Wall Area in Zone 3 = 18961 40'2.------WALLS--ZONE 4------------------------------------------------ I --- Elevation Type U Insul R Gross(Sgft)l M - --- -- - -- - - ---- - - - - - - -- - - - - - - - - - - -- - - - - -- --- - - -- --- - - - - -- -- -- - - - I West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 4321 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 5521 East 81'CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 480I North 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 6 w 4321 Total Wall Area in Zone 4 = 18961 Total Gross Wall Area = 79481 403.------DOORS--ZONE 1 ------------------------------------------------ Elevation Type U Area(Sgft)I --------------------------------------------------- ----- --------- South- 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 60I North r 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 20I Total Door Area in Zone 1 = 80I 403.------DOORS--ZONE 2---------------------------- -------------------- I--- Ele'vation Type U Area(Sgft)I --------------------------------------------------- ----- ---------- South 1-3/4 Steel Door -Polystyrene core (18 g 0.35 20I Total Door Area in Zone 2 = 20I 403.------DOORS--ZONE 3 ------------------------------------------------ I --- Elevation Type U Area(Sgft)I.: --------------------------------------------------- ----- ----------I South 1-3/4 Steel Door -Solid core flush 0.40 20I Total Door Area in Zone 3 = 20I 403.------DOORS--ZONE 4 ------------------------------------------------ I --- Elevation Type U Area(Sgft)I --------------------------------------------------- ----- ----------I South 1-3/4 Steel Door -Solid core flush 0.40 20I Total Door Area in Zone 4 = 20I Total Door Area = 140I 404------- ROOFS --ZONE 1 ------------------------------------------------ I --- Type Color U Insul R Area(Sgft)I ------------------------------------ ------ ----- ------- ----------I Conc Tile/l/2"WD Deck/WD Truss/ Medium 0.028 30 3120I Total Roof Area in Zone 1 = 3120I 404------- ROOFS --ZONE •2------------------------------------------------ I --- Type Color U Insul R Area(Sgft)I ------------------------------------ ------ ----- ------- ----------I Conc Tile/1/2"WD Deck/WD Truss/ Medium 0.028 30 540I Total Roof Area in Zone 2 = 540I 404.------ROOFS--ZONE 3 ------------------------------------------------ I --- Type Color U Insul R Area(Sgft)I ------------------------------------- ------ ----- ------- ----------I Shngl/1/2"WD Deck/WD Truss/6"Ba Light 0.040 19 15751 Total Roof Area in Zone 3 = 15751 404.------ROOFS--ZONE 4 ------------------------------------------------ I --- Type Color U Insul R Area(Sgft)I ------------------------------------ ------ ----- ------- ----------I Conc Tile/1/2"WD Deck/WD Truss/ Medium 0.028 30 15751 Total Roof Area in Zone 4 = 15751 Total Roof Area = 6810I 405------- FLOORS -ZONE 1------------------------------------------------ I --- Type Insul R Area(Sgft)I -----------------------------------------------------------------I Stab on Grade/Uninsulated 0 28801 Total Floor Area in Zone 1 = 2880I .405.------FLOORS-ZONE 2------------------------------------------------ I --- Type Insul R Area(Sgft)I -----------------------------------------------------------------I Slab on Grade/Uninsulated 1 5401 Total Floor Area in Zone 2 = 5401 405.------FLOORS-ZONE 3 ------------------------------------------------ .Type r Insul R Area(Sgft)l ----------I ------------------------------------------------------- Slab on Grade/Uninsulated 1 15751 Total Floor Area in Zone 3 = 15751 .405.------FLOORS-ZONE 4------------------------------------------------ I --- Type Insul R Area(Sgft)l -------------------------------------------------------- Slab on Grade/Uninsulated 1 ----------I 15751 Total Floor Area in Zone 4 = 15751 • Total Floor Area = 65701 406..------INFILTRATION -------------------------------------------------- I--- (CHECKI Infiltration Criteria in 406.1.ABCD have been met. 1 I MECHANICAL SYSTEMS CHECK ------------------------------------------------------------------1-----1--- HVAC load sizing has been performed. (407.1.ABCD) I 1 407.------COOLING SYSTEMS ----------------------------------------------- Type No Efficiency IPLV ------------- ----- --------------I Tons) ---------------------------- 1. Split System 3 10 10 5.001 2. Split System 1 10 10 1.501 3. Split System 1 10 10 5.001 A. Split System 1 10 10 5.001 408.------HEATING SYSTEMS ----------------------------------------------- I --- Type No Efficiency -------------------------------- --- ---------- --------------I BTU/hrl 1. Electric Resistance 3 .88 340001 2. Electric Resistance 1 .88 170001 3. Electric Resistance 1 .88 340001 4. Electric Resistance 1 .88 340001 409.------VENTILATION ------------------------------------- --------------- I--- ICHECKI Ventilation Criteria iri 409.1.ABCD have been met. 1 1 410.-----AIR DISTRIBUTION SYSTEM ---------------------------------------- I--- ------------------------------------------------------------------1-----1--- CHECKI Duct sizing and design have been performed. (410.1.ABCD) I I AHU Type Duct Location R-value) --------------------------------------------------------- 1. Constant Volume Conditioned Space -------I 61 '2. Constant Volume Conditioned Space 61 3. Constant Volume Conditioned Space 61 4. Constant Volume Conditioned Space 61 CHECKI ------------------------------------------------------------------I-----I--- Testing and balancing will be performed. (410.1.ABCD) I 1 411------ PUMPS AND PIPING -ZONE -------------------------------- Basic prescriptive requirements in 411.1.ABCD have been met. 1 1 PLUMBING SYSTEMS 411------ PUMPS AND PIPING -ZONE 1---------------------------------------I--- Type R-value/in Diameter Thicknessl - .------------------------ 1. Non -Circulating --------------------------- I 411.-----PUMPS AND PIPING -ZONE 2--------------------------------------- I--- ' Type t R-value/in Diameter ,Thicknessl ------------------------ 1. Non -Circulating --------------------------- 6 1 11 • 411.-----PUMPS AND PIPING -ZONE 3--------------------------------------- I --- Type ------------------------ R-value/in Diameter Thicknessl ---------------------------1 411.-----PUMPS AND PIPING -ZONE 4 --------------------------------------- Type ---r-------------------- R-value/in Diameter Thicknessl ---------------------------I 41.2.-----WATER HEATING SYSTEMS -ZONE 1 ---------------------------------- Type ------------------------ Efficiency StandbyLoss InputRate Gallonsl ----------------------------------------I 412.-----WATER HEATING SYSTEMS -ZONE 2 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallonsl ----------------------------------------I •------------------------ 1. <=75,000 Btuh .88 1 .87 401 412.-----WATER HEATING SYSTEMS -ZONE 3---------------------------------- I --- Type Efficiency StandbyLoss InputRate Gallonsl ----------------------------------------i ------------------------ 412.-----WATER HEATING SYSTEMS -ZONE 4 ---------------------------------- Type ------------------------ Efficiency StandbyLoss InputRate Gallonsl ----------------------------------------I ELECTRICAL SYSTEMS CHECRI 413.-----ELECTRICAL POWER DISTRIBUTION ---------------------------- Metering criteria in 413.1.ABCD have been met. 1 1 414.-----MOTORS ---------------------------------------------------1-----I--- Motor efficiencies in 414.1.ABCD have been met. I 1 415.-----LIGHTING SYSTEMS -ZONE I --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)I ---------- ----------------- ----------------- --- ------ ----------I Auditorium 1 On/Off 5 On/Off 2 2620 30551 Total Watts for Zone 1 = 26201 Total Area for Zone 1 = 30551 415.-----LIGHTING SYSTEMS -ZONE 2--------------------------------------- I --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)l ---------- ----------------- ----------------- --- ------ ----------I •Bedroom 1 On/Off 2 On/Off 2 470 5251 Total Watts for Zone 2 = 4701 Total Area for Zone 2 = 5251 415------- LIGHTING SYSTEMS -ZONE 3 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)l ---------- ----------------- ----------------- --- ------ ----------I Reading, T 1 On/Off 2 On/Off 2 860 16101 Total Watts for Zone 3 = 8601 Total Area for Zone 3 = 16101 415.-----LIGHTING SYSTEMS -ZONE 4--------------------------------------- I --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)I ---------- ----------------- ----------------- --- ------ ----------I Reading, T 1 On/Off 2 On/Off 2 860 16101 Total Watts for Zone 4 = 8601 Total Area for Zone 4 = 16101 Total Watts = 48101 Total Area = 68001 h � • ICHECKI Lighting criteria in 415.1.ABCD have been met. I 1 ------------------------------------------------------------------I--�- I--- 16% Operatiop/maintenance manual will be provided to owner.(102.1)1 I 70- SJN 1812 i For: By: Job #: 99197 RIGHT-N ZONE SUMMARY APOSTLE FAITH CHURCH OF DELIVERANCE Jack Jewell P.E. C O O L I N G L O A D 4-20-2000 4 ZONE: ZONE 1 APOSTLE 1. DESIGN CONDITIONS at 3PM Peak load at 3PM r Inside: 75 F Outside: 90 F TD: 15 deg F RH: 50 % Grains: 62 Mult: 1.0 Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 5926 - 3. TRANSMISSION GAINS Sensible 20711 - Walls: 3611 - - Glass: 1710 - - Doors: 1512 - - Partitions: 100 - - Floors: 1500 - - Roofs/Ceilings: 11318 - - Return Air Ceiling: 960 - - 4. INTERNAL HEAT GAIN' Sensible Latent 89057 45000 Occupants: 45000 45000 - - Lights: 17013 0 - - Motors: 23744 0 - - Appliances & Other: 3300 0 - - 5. INFILTRATION: Outside air CFM: 200 3300 8432 6. SUBTOTAL: Space load 118994 53432 7. SUPPLY DUCT 35698 - 8. SUBTOTAL: Bldg comp's and supply duct 154692 - Actual CFM: 7033 at Supply TD: 20 - - 9. VENTILATION: Make-up air CFM: 600 9900 25296 10. RETURN AIR LOAD: Lighting & roof (net) 9972 - 11. RETURN DUCT 11899 - 12. TOTAL LOADS ON EQUIPMENT 186463. 78728 1 H E A T I N G L 0 A D 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 F Outside: 42 F TD: 28 deg F J 141. TRANSMISSION LOSSES 19315 ,��. 0 Walls: 5475 / v�10 Glass: 3192 ^`TY.BUILD�iG _ - Doors: CO nL - Partitions:o�C!/ - Floors: B�pT-pT� Roofs/Ceilings: 0�� 38 ��iIT E E- Return Air Roof : �LeNS VNI) 1Q1aI�r1LLB _ 15. INFILTRATION: Outside alaN 403 12419 16. SUBTOTAL: Building components 31734 17. SUPPLY DUCT 3173 18. VENTILATION: Make-up air CFM: 0 0 19. HUMIDIFICATION 2189 -• 20. RETURN DUCT 952 21. TOTAL HEATING LOAD ON EQUIPMENT 38048 MANUAL N: 4th Ed. RIGHT-N: V1.15 rVDTTWTVn QV nrrn Mn M17FT AT.T. R17n11TRRMRNTS ni? MANHAT. FORM N ®0 SIN 1812 70RIGHT-N ZONE SUMMARY 4-20-2000 For: APOSTLE FAITH CHURCH OF DELIVERANCE By: a Jack Jewell P.E. Job #: 99197 ZONE: ZONE 2 APARTMENT C 0 0 L.I N G L 0 A D 1. DESIGN CONDITIONS at 3PM Peak load at 3PM Inside: 75 F Outside: 90 F TD: 15 deg F RH: 50 % Grains: 62 Mult: 1.0 Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 940 - 3. TRANSMISSION GAINS Sensible 4668 - Walls: 666 - - Glass: 549 - - Doors: 252 - - Partitions: 320 - - Floors: 900 - - Roofs/Ceilings: 1981 - - Return Air Ceiling: 0 - - 4. INTERNAL HEAT GAIN Sensible Latent 5871 900 Occupants: 900 900 - - Lights: 1311 0 - - Motors: 2360 0 - - Appliances & Other: 1300 0 - - 5. INFILTRATION: Outside air CFM: 27 444 1133 6. SUBTOTAL: Space load 11923 2033 7. SUPPLY DUCT 1192 - 8. SUBTOTAL: Bldg comp's and supply duct 13115 - Actual CFM: 596 at Supply TD: 20 - - 9. VENTILATION: Make-up air CFM: 240 3960 10118 10. RETURN AIR LOAD: Lighting & roof (net) 738 - 11. RETURN DUCT 1192 - 12. TOTAL LOADS ON EQUIPMENT 19005 12152 H E A T I N G L O A DZ� 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 F Outside: 42 F TD: 28 deg F 14. TRANSMISSION LOSSES 5654 Walls: 1034 - Glass: 1025, - Doors: 470 - Partitions: 597 - Floors: 1680 - Roofs/Ceilings: 847 - Return Air Roof: 0 - t� 1n 15. INFILTRATION: Outside air CFM: 40 1242 16. SUBTOTAL: Building components 6895 17. SUPPLY DUCT 0 18. VENTILATION: Make-up air CFM: 0 0 19. HUMIDIFICATION 219 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 7114 MANUAL N: 4th Ed. RIGHT-N: V1.15