Loading...
HomeMy WebLinkAboutNOA; Sta-Tru half Lite Single Outswing Residential Insulated Steel Door�_.j • MIAMI-DADS MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 PRODUCT CONTROL NOTICE OF ACCEPTANCE (305) 375-2901 FAX (305) 375-29,08 Stanley Door Systems NC CONTRACTOR LICENSING SECTION 7300 Reames Rd. (305) 375-2527 FAX (305) 375-2558 Charlotte NC 28216 CONTRACTOR ENFORCEMENT SECTION (305) 375-2966 FAX (305)375-2908 PRODUCT CONTROL DIVISION Your application for Product Approval of: (305) 375-2902 FAX (305) 372-6339 Sta-Tru 112 Life Single 011fSWing Residential Insulated Steel Door under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for duality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code, The expense of such testing will be incurred by the manufacturer. Acceptance No.:99-1104.01 Expires:02/18/2001 Raul Rodriguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the BLlildin�; Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. O �Iy^^'ISIOti ®®I" G D B , p� O1�I 10S NI( S rliAp�• . Approved: 03/24/2000 ®N' "NWN �E ,rancisco . Quintana, R.A. Director Miami -Dade County Building Code Compliance Offick .. Intnrnat moil orlrlrocc• nnetmocterrn)huildinornriPnnlina_rnm om Homenave- httn--//www_huildinorndeonline.com MAKE SOMETHING GREAT' HURRICANE DOOR SYSTEM DESIGN PRESSURE RATING POSITIVE 50.0 PSF NEGATIVE 50.0 PSF SISTEMA PARA PUERTAS HURRICANE NOTICE OF ACCEPTANCE AND APPROVAL / INSTALLATION DRAWINGS SAVE FOR BUILDER AND INSPECTOR Part # 39098 • Stanlev Door Systems ACCEPTANCE No.: 99-1104.01 APPROVED •MAR 2 4 2000 EXPIRES : February18, 2001 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This approves a residential insulated steel door, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series Sta-Tru %: lite Glazed Single Outswing Residential Insulated Steel Door and its components shall be constructed in strict compliance with the following documents: Drawing No: S-99-63 titled "Sta-Tru door outswing / Glazed" Sheets 1 through 4 of 4, dated 10-14-99, revised on 02-16-00, prepared by RW Consulting, bearing the Miami -Dade County Product Control approval stamp with the Notice of Acceptance .number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications of single door only, as shown in approved drawing. 4. INSTALLATION 4.1 The residential insulated steel door w/sidelite and its components shall be installed in strict compliance with the approved drawings. 4.2 Hurricane protection system (shutters): the installation of this unit will require a hurricane protection system. 5. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. 1S lta I . L(&a, _. Ishaq I. thanda, P.E. Product Control Examiner Product Control Division 2 of Stanley Door Systems ACCEPTANCE No.: 99-1104.01 APPROVED MAR 2 4 2000 EXPIRES :February 18, 2001 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: ' a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process. b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer -or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. I e, t . e-, La "a-_ Ishaq Chanda, P. E., Product Control Examiner Product Control Division END OF THIS ACCEPTANCE 3 of 3 4.563' .. •Y •: °• 1.15' MIN. EMB, 250 CLEARANCE MAXIMUM r 0.75' T 1.2I5' .15' MIN. COUNTERSINK r I O • • 15 '• 1 o •• • o .023' DOOR MATERIAL THICKNESS 1.25' ►- EXTER10a = W U 2 W W 2 J W Z Q J a J Q � O W X O a 2 � o m m I 1,25' MIN, EMB, ••. '. .: , 1 3/4' OVERALL DOOR THK, VERTICAL CRO 2 PLACEMENT 4.65' 1,15' MIN, EMBEDMENT — ,25' MAX, SHIM .15' MIN, COUNTERSINK DSS SECTION -i 35,75' MAX P,W, Y a v x o� r` A 4' 4 N LJ (U co } A N N Nl p `t AMU I� p (4 N p x: W W O o -i J N o F-m= 2 N r- U Q. N J w 4.5625' JAMB WIDTH o w y oA A Q UO • i = pcy- QQ m ~ IN W Z 08 p ~ ~ V' p N < Z o, Q N � p0 b OQ p U p W 4 4 a a N MTl 141 Ru( CONSULTING (813) 684-3831 APPROVED AS COMPLYING WITH THE DATE` 10-14-99 SOUTH FLORIDA BUILDING CODE DATE U 4, Z oo o SCAM N.T.S. Dwc. BY: RWBC PRODUCT CONTROL DIViS.Ohi OWING NO.: BUILDING CODE COMPLIANCE 0£FICE ACCEPTANCE N0,�_,�-_ �I04,01 S99-63 sHEET 3 OF 4 v� 6' MAX TYP- SEE NOTE #1 NOTEi 1, USE 3/16' TAPCON WITH 1.25' MIN, EMBEDMENT INT❑ MASONRY (ITW OR ELCO), 2, THRESHOLD ATTACHED TO SIDE JAMB WITH, (2) #8 X 2,25' PFHWS, 6' MAX TYP F 6' MAX, TYP No= SEE NOTE #2 6' MAX TYP 37.5' O.A. MAX. F.W. u 'ENTS :RIPTION TYPICAL ELEVATIONS. ECTIONS & BILL OF MATERIALS SECTIONS & DOOR MODELS & GLAZING DETAILS H w � N BAN n H O MIXU� OyZN P w 0`1 LLJ -i -i Z C3 (y QoQ _ F-M3: = o I% U D_ p O N Li 00 A J ❑ F~- J Z¢ > U W QJ ZLi Fi F- N f� ~ O UQ ❑ 0 a. a DESIGN PRESSURE RATING WHERE WATER INFILTRATION REQUIREMENT IS NEEDED POSITIVE + 50.0 PSF NEGATIVE - 50.0 PSF APPROVED AS COMPLYING WITH THE SOUTH RORIDA/BUILDING CODE DATE eaw Z 4,Z.000 BY 15ln-l! \ . (lnciow-I •- PRODUCT CONTROL DIV'S-UN BUILDING CODE COMFL.ANCE Di�CE ACCEPTANCE NO.=0 0 Rw CONSULTING (813) 684-3831 DATE: 10-14-99 SCAM N.T.S. DING. BY: RWBC CHK. BY: - DRAPANC NO.: S99-63 1 OF STANLEY DOOR SYSTEMS1 STA—TRU OUTSWING GLAZED STEEL DOOR WITH WOOD FRAME GENERAL NOTES 1. THIS PRODUCT IS DESIGNED TO MEET THE SOUTH FLORIDA BUILDING CODE 1994 EDITION FOR MIAMI—DADE COUNTY. 2. WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. 3. PRODUCT ANCHORS SHALL BE AS LISTED AND SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL FINISH OR STUCCO. 4. MIAMI—DADE APPROVED IMPACT RESISTANT SHUTTERS REQUIRED. 5. LATEX OR SILICONE CAULKING AS NEEDED TO SEAL UNIT INTO BUILDING ENVELOPE. 6. ALL DIMENSIONS ARE GIVEN IN INCHES UNLESS OTHERWISE SHOWN. OUTSWING INSULATED STEEL DOOR (Common to 'all frame conditions) Door Leaf Construction: Face sheets: 24 ga. (0.023") minimum thickness, Galvanized steel A-525 commercial quality — AKDQ per ASTM 620 with min. yield strength of 36.34 ksi. Core design: Polyurethane foam (BASF) core laminated to inside faces. Construction: The steel face sheets are crimped to fit hinge and lock stiles, terminating with a 90 degree bend. The latch stile is reinforced LVL. The panels are routed and reinforced with a continuous steel channel 0.035" thick to receive the lip lite inserts. Glazing: See Glazing Details "A" & "B" on Sheet 4. TABLE OF C SHEET # [ 1 GENERAL NOTE`. 2 VERTICAL CROS 3 HORIZONTAL CF 4 ANCHOR LOCAT r ITEM DESCRIPTION MATERIAL 1 DOORSKIN .023" STEEL • 2' 1.68"X1.18" LATCH STILE LVL 3 1.61 "X.75" LATCH STILE REIF, CHANNEL STEEL CHANNEL 4 1.68"X1.22" HINGE STILE PINE 5 1.68"X1.22" TOP RAIL PINE 6 1.68"X1.00" BOTTOM RAIL (NEWELL) PVC -7 HINGES 4" X 4" X .088 WT. (STANLEY) C.R. STEEL B /8 x 1-1/2" PFH WS - .9 MAGNETIC WEATHERSTRIP (HOLMES) 9B COMPRESSION WEATHERSTRIP SCHLEGAL QDS 650 VINYL FOAM 10 COMPRESSION WEATHERSTRIP HOLMES 9B COMPRESSION WEATHERSTRIP SCHLEGAL QDS 650 VINYL FOAM 11 COMPRESSION WEATHERSTRIP, THRESHOLD FOAM 12 HEAD JAMB FlNGERJOINT PINE -13 HINGE JAMB FlNGERJOINT PINE 14 LATCH JAMB FlNGERJOINT PINE 15 POLYURETHANE FOAM CORE (BASF) TYPE A. INFINITY: RESIN (P14120R) ISOCYANATY (P1001), CYCLOPENTANE. TYPE B. RETRO: RESIN (P12430R), ISOCYANATY (Pl036). �16 18 x 2 1/2" PFH WS - 17 18.75"X3.0"X1.67" LOCK BLOCK WOOD (PINE) 18 LITE FRAME (ODL SPARTECH DC-164-3-05) SEE DETAIL "A" 1" GLASS SHEET 4 OF 4 or SEE DETAIL "B" 1/2" GLASS SHEET 4 OF 4 PbLYPROPYL.ENE 19 LFFE FRAME ANGLE SUPPORT - 20 GLASS - 1/2" or 1" INSULATED SEE DETAIL "A" 1" GLASS SHEET 4 OF 4 or SEE DETAIL "B" 1/2" GLASS SHEET 4 OF 4 0.125" TEMPERED 21 KWIKSET 660 DEADBOLT - 22 KWIKSET SERIES 200 DL PASSAGE 23 /8 x 1 1/4" PFH WOOD SCREW 25 18 x 1 1/4" PFH WOOD SCREW - 26 #9 x .625 F.H. WD SCREWS - 27 #9 x 1.00 F.H. WD SCREWS 28 #10 x 2" PFH WD SCREWS 29 BUMP THRESHOLD (WORLD WIDE) ALUMINUM / WOOD 30 3/16" TAPCON (ITW) OR 3/16" (ELCO) STEEL 31 N/A r32 If 8-1 1/4" TEK SCREW SECTION APPROVED AS COMPLYING WITH THE SOUTHFLLORIDA BUILDING CODE , OATE�4,�Ia, Z,. -2 O O 0 BY L su.,1. • e-L— . PRODUCT CONTROL DIVIS•ON BUILDING CODE pCOMPUA.NCE OFFICE ACCEPTANCE NO. J_t_7 L� " ' LJ (U yAGo N^ N C3 o�M u cy) 00Z fU Axw ¢F-.. >_ w IF- � i _j N 0 ty M r- U (L Z o� w W� J Na LJ sa o J y 0 x m of U F- Z } 0 I¢ y J J U N ~ 0 U ~ j Ga 0 > as 9 Rw CONSULTING (813) 684-3831 DATE: 10-14-99 sc&E: N.T.S. mG. BY: RWBC F K.BY: — AWING NO.: S99-63 SHEET 2 OF INTERIOR e3lHORIZONTAL PLACEMENT ❑PTIONAL GLAZED DOOR MODELS (SHUTTERS REQUIRED) DETAIL 'A' 1' GLASS INSERT STEEL SPACER BLOCK INTERIOR SIDE A N C3 GLAZING SCREW � u m #8 x 1,250 z N 12' O.C. MAX, .4138 OPTIONAL INTERNAL GRILL A W w M 19 1' THK, OR DECORATIVE LITE w GLASS ,125' GLASS (TEMPERED) J J � • '°' ¢ o ¢ v ° 0,75' AIR v~i m � m 1,75' ' ' 0 0 o SPACE ,. a •° a o 0 ,125' GLASS (TEMPERED) QSO-16 GLAZING----' / �QSO-16 GLAZING SEALANT w 0 SEALANT L N J LITE FRAME POLYPROPYLENE (ODL) SPARTECH DC-164-3-05 A a � R ! ¢ w >- U A • L7 Ct�' rZ- m w C3 J z " � O= Q DETAIL 'B' 1/2' GLASS INSERT N = U STEEL SPACER BLOCK a O z ¢ INTERIOR SIDE o GLAZING SCREW x 1,2�,4138 12 12 MAX. D.C, MOPTIONAL INTERNAL GRILL a a ? r QSO-16 GLAZING SEALANT 1/2' THK, GLASS -0,125' GLASS (TEMPERED) �— .25' AIR SPACE ,125' GLASS (TEMPERED) QSO-16 GLAZING SEALANT LITE FRAME POLYPROPYLENE (ODL) SPARTECH DC-164-3-05 Ru( CONSULTING (813) 684-3831 APPROVED AS COMPLYING WITH THE OATS: 10-14-99 SOUTH FLORIDA BUILDING CODE SCAL-EN.T.S. DATE 2L1.� Z 4 44" Dwc. BY: RWB C BY z-"vJ— CHK. BY: — PRODUCT CONTROL DIV!S:ON DRAWING NO.: BUILDING CODE cC�OMPLIANCE�OFFICEE ACCEPTANCE NO. J y 7169 .0IC/ S99-63 SHEET 4 of 4