Loading...
HomeMy WebLinkAboutLog of Approved Inspections; TrussRAUL R. VALELLA ARCHITECT 00010459 138 S.E. Naranja Ave Pt St. Lucie, Florida 34983 (661) 871-2457 (661) 873-1365-fax ST. LUCIE COUNTY LOG OF APPROVED INSPECTIONS TO COMPLY WITH FBC2001 PERMIT # ADDRESS: 1505 NORTH 43ro ST A/E: RAUL R. VALELLA, ARCHITECT CONTRACTOR: LERY BENNET JR TYPE OF INSPECTION: TRUSS STRAPS COMMENTS CORRECTIONS WERE MADE AS PER ARCHITECTS ADDENDUM LETTER OF 10 - 30 - 02 AND AS PER NEW DRAWING (WINDOW FRAMING...) nrr-rcVytU t3Y' RAUL R. VALELLA TYPE OF INSPECTION• COMMENTS: APPROVED BY: DATE: TYPE OF INSPECTION: COMMENTS: APPROVED BY: DATE: TYPE OF INSPECTION• COMMENTS: APPROVED BY: DATE: RAUL R. VALELLA ' ARCHITECT #0010469 FEB 138 S.E. Naranja Ave post[# Pt. St. Lucie, Florida 34983561 8T1-2457 �tt4�� ' t ) �gticd (581) 8T3 1385 Feb. 11,.2003 SAINT LUCIE COUNTY BUILDING DEPARTMENT FORT PIERCE, FLORIDA RE: APOSTLE FAITH CHURCH OF DELIVERANCE INC. 1505 NORTH 43r S" treet Fort Pierce, Fla. Permit #Z161045,3 Contractor. LEROY BENNET, JR. CONSTRUCTION COMPANY 2101 VALENCIA AVE FT. PIERCE, FL 34946 Dear Mr. (Building Official); I, (Raul R. Valella, Architect), having performed and approved the required inspection, as indicated in the attached approved inspection log, hereby attest that to the best of my knowledge, believe and professional judgment, that the STRAPPING FOR THE TRUSSES HAS BEEN SATISFACTORILY COMPLETED and is in compliance with the Florida Building Code 2001, approved plans -and other approved permit documents. I also attest to the best of my knowledge, belief and -professional judgement, the approved permit plans represent the as -built condition of the said project. Should you have any questions or need any additional information, please do not hesitate to contact me. Sin rely, Raul R. Valella Architect #0010459 RAUL & VALELL 1 38 S.E. Naranjo Ave ARCHOTECT Pt St. Luote, FL. 34983 AR # 0010459 Phone : (561) 671-a2457 addedum to jab at 1505 n. 43rd St. Fort Pierce Correction to as built per notice by building dept 1.) USE 2- WASHERS ON ALL ANCHOR BOLTS AS PER SLOG IP� UT NOTICE z) e. INSTALL NEW WIS1 STRAP 1 W01CORNER 6�W% d 10d O TRUSS AND 4 t/4 x� i/4•IT,swcoI-21266a0 2730 + 1200 . 3990 y 3534# e b. AT FG2 WMNG TO CORNER 2 NEWS W/10 10d - 12400 INSTALL 2 NEW TWIST STRAP 2) FRS ifM S W/ D 10d To TRUSS AND 4) 1/4- )( 2 1/4- TITEN . 2520f 2520 + 1240'- 3;00 2o 3534J 3.) ADD STRAP TO KING JACKS SIMPSON MTSt2 4.) ADD 2KHTSNt� HAS 1 META 2D W/16-10d K1 1/2 -116Y0#/ REQUIRES 32570 ADD + 2520# ! 9 70 TR44101 RUSSSS AND 4) 1/4 X 2 1/4. UTENS TO CONO BU - 120a X2 -2520# 267 5.) ALL STRAPS THAT MISSED THE TRUSS OVER 3/4` OF AN INCH ; INSTALL 1) HTSM76 W/ 0) 10d AND 4) 1/4- X 2 1/V TMN TO CONC SM 6.) FRAMING CONTRACTOR NA5 LETifJi OF INSPECTION CHECK IF SM DEFT. ACC67T3 THIS LErTEdt 7.) 00 DRAFT STOP AS REQUIRED e.) WALL OVER ENTRY NOT STRAPPED (CALLED ED FOR SF-4) IPWALL SMWN Ho W/ 5)tOd TO PLATE & 5) 10d TO STUDS //��� � 9.) DO SMOKE BARRIER AS PER -4 3 #, o Dlig . / AAO&Ae — . 5?•-e0 /�• 50+M4 Sin f 10.) SIMPSON 51RAP H-7 it If DWALLED SEE S%*N 1/A-10 11) 2- X 6- INTERIOR BEARING WALLS REQUIRES STRAPING AND INTERMIDIATE BLOCKING AS SHOWN 1/A-10 12.) TRUSS COMPANY TO ISSUE T-34 GIRDER ENGINEERING 541ET 13.) ARCHRECT KMSEO DETAIL XX/A-12 SEE REWSIONS To I/A-7 AND 1/A-e 14.) WHERE GIRDER T-34 REST' ON 2 X 6 BEARING WALL IIO WAIL AS PER 3/A-12 Vlj7' Qp f 15.) T-4 INSTALLED BACKWARDS ASK TRUSS COMPANY FOR I INTER OF APPROVAL 16.) INSTALL TRUSS BRACING AS REQUIRED ON T32. Tte, T341 17.) FM AND F02 TRUE= INSTALLED UPSIDEDOWN ASK TRUSS COMPANY FOR LETTER OF APPROVAL 18.) kNEE WALLS F03 AND-I2 NOT STRAPED TO TRUSSES A$ PER DETAIL 1/A--8 SP-4 INSTALL WISIS AT EACH SM TO TRUSS W/ 14-10d AT; BASE AND TOP PLATES 19.) MW NOT NAILEXISTING STRAP TO ATRUSSW/CORNER 10d NPLUS DO $OMMENT 02 ABOVE 20.) BOLTS LOOSE AT FRAME WALL OVER ENTRY INSTALL. 2- WASHERS AND TIETEN / '_2 �- TO 39Vd HZ)NnHO HlIVJ 31ll5OdV VOIL179PT99 ET:91 E00Z/90/Z0 BEYOND AS BU,-ILT CONDITION SCALE: 3/4" =1'-0" REINFORCIN DO NOT DETACH OR REMOVE ANYTHING STRUCTURAL EXISTING INSTEAD ADD VERTICAL STUDS AND STRAPS AS SHOWN HATCHED SIMPSON MSTA15 W/ ALL HOLES FILLED TO EXISTING SCALE: 3/4" =1'-0" FT JAR # 0010459 PLANNING do DESIGN 138 S.E. Naranjo Ave Pt St. Lucie, FL. 34983 Phone : (561) 811-2457 i