HomeMy WebLinkAboutUNDERLAYMENTS TRI BUILT SHINGLE4/9/2020
Florida Building Code Online
litMM
.
a r
6CI5 Home Lop In User Registration Mot Topics Submit Surcharge Stats B Facts Publications Contact Us BCIS Site Map Links Search
db4Prodluct Approval- ! USER: Public user
Product Approval Menu � Product or Aoprication Search a Application List > Applicatlon Detail
FLUil
#
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Ernall
Category
Subcategory
Compliance Method
FL16048-R6
Revision
2017
Approved
Tri-Built Materials Group, LLC
PC) Box 70
Rutherford, N] 07070
(800)516-1485
david.ru iz@tribu i Itmg. cam
David Ruiz
davi d , ru ix @try b u i Itmg . co m
David Ruiz
250 Route 17 North
East Rutherford, NJ 07073
(201) 642-2449
david.ruiz@tribuiltmateriaisgroup.com
Roaring
Undertayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity lA LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich, PE
Vaiidation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
F 16048 R6 COT 2017 01 COI Nieminen. df
$-7ndard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 f 04-12)
LJL 1897
Year
2015
2075
2011
2012
2012
https-.IAvww.florsdabuilding.orglpripr app dtl.aspx?param--vGEVJCC�MD tFPmdYiNDWrwipmtAnRgjv9FiYHTk4FLCxcgVfRhfvMwok3d%3d 112
4/9/2020
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option ❑
Pate Submitted
09/25/2017
Date Validated
10/01/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/2017
Summary of Products
FL
Model, dumber or Name
oesciription
16048.1
TRI-BUILT hoof Underlayments
Self -adhering, modiC-ied bitumen roof undeflayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 II 2017 09 FINAL ER TR -
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENTa `L16048-R6.pdf
1 Impact Resistant: N/A
Design Pressure: +NIAI-150
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
? Other: 1.) The design pressure noted herein pertains to use of
Evaluation Reports
foam -on tile systems overtop the self adhering underlayment
FLI.5048 Rb AE 2017 09 FINALR TRI-
for one particular application. See ER Section 5.6.4 for details.
UILT UNDEPLAYMENTS F 4 -P df
2.) Refer to ER Section 5 for other Limits of Use.
Created by Independent Third Party: Yes
Cunt= LIS :: 26131 elair Stone Road,TiRa ha55ee FL 32399 One: 850-487- ISZ4
The State of Florida is an AA/EEO employer. CopX�ght 2007-2013 State of Fbdda.:; Priv .s"la„tement :: Accesahilitv-5=nleM :: P.e nd 5
Under Florida law, email addresses are public ramrds. If you do not warn your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office try phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.s_ must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record_ If you do not wish to supply a personal address, please
provide the Department with an email address which can be. made avaiiable to the public. To determine if you are a Licensee under Chapter 455, F.S., please [rick here .
product Approval Accepts;
Credit Cart}
Safe
https:l/www.floridabuliding.orglpripr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWrwipmtAnRgjv9F-iYHTk4FLCxogVtRhfvMw%3d%3d 2/2
TRINITYERD
EVALUATION REPORT
TRI-BUILT Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800)516-1485
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report A42960.10.12-116
FL16048-R6
Date of issuance:10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTiow TRI-BUILT Roof Underlayments
LABELING: Labeling Shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature- If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, I.E.
Florida Registration No. 59166, Florida DCA ANE1983
M.
.Lg'� 3• s�-1�� :fir �`rw
The facsimile sea la earin was authvrixed6 Roheri Nieminen,
.J1rne.iy�e, �ti PP g Y
P.E. on 09/25/2a17. This does not serve a5 an electmnirally signed
document.
CEFrnF(CA-rlON OF INDEPENDMCE:
I. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically far that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION.
I. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSACTRI April 2012 (04-12)
2012
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
540540.11.13
11/19/2013
ERD (T5T6049)
Physical Properties
S40540.03.14
03/26/2014
ERD (T5T6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
544870A4.14-4
04/10/2014
ERD (TST6049)
Physical Properties
543530.02.14-1-RI
05/14/2014
ERD (TST6049)
Physical Properties
S43530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERE] (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD(TST6D49)
Accelerated Weathering
SC8520.04.15
05/27/2015
ERD (TST6049)
Wind Resistance
SC14045.05.17-111
06/07/2017
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT ❑ESCRIP11ON:
4.1 Tri-Built Sand -Ft SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVH7jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Repo rt A42960. Ia. 12-R6
CertijkGteOfAuthorization #9w3 6" EDITION (2017) FBC NON-HVH2 EVALUATION FL161048-RG
TRI-BUILT Roof Underlayments; (300) 516-1485 Revision 6: 09/25/2017
Page 2 of 6
TRINITY ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC
approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphlt
Y
Shingles
Wood Shakes Slate
Nail -On Tile Foam -fin Tile Metal
j
& Shingles
Tri-Built Sand-R SA shingle
Underlayment
Yes
I
No
No
No
Yes
Yes
Tri-Built 51A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
Tri-Built Smooth HT S/A
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5A "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayrnent combinations.
TABLE 1A: ALLOWABLE UE ADHESIVE' UNDERLAYMENT COMBINATION51
Adhesive Florida Product Approval Underlayments
ICP Adhesives Polyset"I AH-160 FL6332 Fri -Built S/A HT TU Underlayment
Dow TileBondT" FL22525 Tri-Built 5/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment Or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
0S13 prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
r Dens Deck Prime; SECUROCK Gypsum -Fiber Hoof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-built 5/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underiayment
system fn accordance with FM 4474, Appendix DarTAS 114, Appendix J.
Refer to Tile Manufacturer's or Adhesive Monufncturer's Florida Product Approval for Overturning Moment Resistance Performance.
brterior Research and Designs, LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization #95a3 6' EDITION (2017) FBC NON-HVH2 EVALUATION FL16048-R6
TRI-BUILT hoof Underlayments; (900) 516-148S Revision 6: 09/25/2017
Page 3 of 6
TRINITY ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
)' ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on the systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underla ment S stems in Foam -On Tile Applications FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure = -450 nsf:
Dock: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5 sf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built SIA HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure = -150.0 nsf:
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer:
(Optional) RES15TO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure _-60.0 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction,
Base Sheet:
Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate ofAuthorizution #95a3 6'Y EDITION (2017) FEC NON•HVHZ EVALUATION FL16048-R6
M-RUILT Roof Underlayments; (800) 516-1485 Revision 6.09/25/2017
Page 4 of 6
TRIM-ry ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria,
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 190-days after installation_
5.8 Tile Slippage Limitations (TAS 103 per FRSA TRI April 2012 04-12 :
When loading roof tiles on the underlayrnent in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE UMITATIONS FOR DIRECT-DECKTILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum
Slope
Fiat Max. 10-tile stack 6:12
Lugged Max. 10-tile stack 5:12
Max. 10-tile stack (bottom 2-tile stack
s h a I f be Inverted, followed by 8 tiles high 6:12
on slope, as shown below) l
Tri-Built S/A HTTlI
Underlayment
Lugged
Exterior Research and Resign, LLC. Eva Iuat!Dn Report A42960.1U.12-R6
Certificate of Authorization #9503 EDITION (2017) F B C NON-HVHZ EVALUATION F1.16048-116
TRI-BUILT Roof Ur►derlayments; (SM) 516-3MS Revision 6. 09/25/2017
Page 5 of 6
TRINITY EIR
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shinizle Underla men# Tri-Built 5 A HT TU Underla meet or Tri-Built Smooth HT 5 A
Underlaylnent:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Ikon -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film,
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications Tri-Built 5 A HTTU Underla ment onl :
Reference is made to FRSA/TRI April 2012 (04-121 Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSAjTRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation Of
this product.
8. MANUFACTURING PLAINTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC -QUA9625; (314) 578-3406; k.chanceltor@us.uLcom
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate Of Authmization #9503 6T" EDITIOAi (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Dnderlayments; (80D) 516-1485 Revision 6: 09f25f2017
Page 6 of 6