HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: W NNE TIJE WIN R IMPACT
BuilderName: WYNNE. DEVELOPMENT
Street: �\
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. WallTypes.(1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior,
R=4.1 1224.00 ft2
b. Frame -Wood, Adjacent
R=11.0 208,00 ft2
3. Numberofunits, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ftz
5. Is this a worst case? Yes
10. Ceiling Types (1783.0 sqft.)
Insulation Area.
a. U rider -Attic (Vented)
R=30.0 1753.06 ft2
6. Conditioned floorarea above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floorareabelowgrade(ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7.. Windows(151 A sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 111.36 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
. 34.8 . SEER:15:00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0..285
14. Hotwatersystems
8. Floor Types (1753.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 175100ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15..Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.17
PASS
Total Baseline Loads: 53.92
'hereby certify that the plans and specifications covered by
Review of the plans and•'
this calculation are in compliance with the Florida Energy
specifications covered by thisr
a
Code.
calculation indicates compliances„'
with the Florida -Energy Code..
PREPAR�p ICY: -
Before construction is completed
_ -
DATE:
this building will be inspected for
compliance with Section 553.908
'
_
.hereby certify that this -building, as designed, is in compliance,
Florida Statutes.
with the Florida Energy Co e.
A�
OWNE
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified _factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
4/21 /202010:04 AM EnergyGauge® USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition' (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT. SUMMARY "CHECKLIST REPORT
`
PROJECT
"
Title: WYNNE THE WINDSOR IMP
Bedrooms: 3
Address Type:
StreetAddress
Building Type: User
ConditionedArea: 1753
L'ot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT
RotateAngle: 0
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction::
'Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
FamilyType:Single-family.
FL,
New/Existing: New (From Plans)
Comment:
'CLIMATE
/
Design Temp
Int Design Temp
Heating
Design DailyTemp
V DesignLocation TMYSite
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL; FortPierce FL VERO BEACH_MUNI . 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1753
14024
SPACES
Number . Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
'No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M.BATH 61
488 No
0
1
Yes
Yes
Yes
5. LAUDRY 36
288 No
0"
1
No.
Yes
Yes
6 BEDROOM 2 180
1440 No
0,
1
1
Yes
Yes
Yes
7 DINING/GREAT.RO 588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209
1672 Yes
0
1
Yes
Yes
Yes
9 BATH 50
400 No
0
1
Yes..
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3„ 169
1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# FloorType Space
Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edgelnsulation .MASTER
BEDRO 37 ft 0
224 ft2
____
0 1
0
2Slab-On-Grade Edge Insulation WIC 1 ft 0
63ft2
____
0 1
0
3 Slab -On -Grade Edge Insulation MASTER BATH 8 ft 0
56 ft2
___
0 1
p
4Slab-On-Grade Edge lnsulation M. BATH 7ft 0
61 ft2
____
0 1
0
5Slab-On-Grade Edge Insulation LAUDRY 1 ft 0
36ft2
____
0 1
0
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORMR405-2017 ANPUT SUMMARY CHECKLIST REPORT
'
FLOORS
# FloorType
Space Perimeter PerimeterR-Vaiue
Area
JoistR-Value
Tile Wood Carpet
6 Slab -On -Grade Edge Insulation.
BEDROOM 2 12 ft
0
180 ft2
____
0 .1.
0
7Slab-On-Grade Edge Insulation
DINING/GREAT 50ft
0
588ft2
____
0 1
0
8Slab-On-Grade Edge Insulation
KITCHEN lift
• 0
209ft2
____
0 1
0
9Slab-On-Grade Edge insulation
BATH 5ft
0
50ft2
____
0 1
0
10SIab-On-Grade Edge Insulation
HALL 1 ft
0
25ft2
____
0 1
0.
11SIab-On-Grade Edge Insulation
FOYER 9ft
0
92ft2
____
0 1
0
12SIab-On-Grade Edge Insulation
BEDROOM 14ft
0
169ft2
____
0 1
0
ROOF.
/
Roof
Gable'
Roof
Rad
Solar
SA Emilt
Emitt: Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1847 ft2'
0 ft2
Light
N
0.4
No 0.9
No 0
18.4
ATTIC.
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC.
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# CeilingType
. Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 UnderAttic (Vented)
MASTER BEDRO
30
Blown
224ft2.
0.1
Wood
2 UnderAttic(Vented)
WIC
30
Blown
631`12
0.1
Wood
3 UnderAttic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 UnderAttic(Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 UnderAttic (Vented)
LAUDRY
30
Blown
36f12
0.1
Wood
6 Under Attic
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 UnderAttic(Vented)
DINING/GREAT
30
Blown
588ft2
0.1
Wood
8 UnderAttic(Vented)
KITCHEN
30
Blown
209ft2
0.1
Wood
9 UnderAttic (Vented)
BATH
30
Blown
50ft2
0.1
Wood
10 UnderAttic (Vented)
HALL
30
Blown
25ft2
0.1
Wood
11 UnderAttic (Vented)
FOYER
30
Blown
92ft2
0.1
Wood .
12 UnderAttic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS-
Adjacent
Cavity Width
Space
Height
Sheathing Framing Solar
Below.
1 E Exterior Concrete Block-
Int InsuMASTER BE '
4.1 16
0 8
0
'128:0 ft2
0
0 0.3
0
2 W Exterior Concrete Block-
Int InsuMASTER BE
4.1 .7 '
0 8
0
56.0 ft2
0
0 0.3
0
_ 3 S Exterior Concrete Block
- Int InsuMASTER BE
4.1'. 14
0 8
0
112.0 ft2
0
0 0.3
0
4/21 /202010:04 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY, CHECKLIST REP.C)RT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar Below
4
E
Exterior
Concrete Block- Int InsuMASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block - Int Insul - M. BATH
4.1 7 .
0
8 0
56.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
7
S
Exterior
Concrete Block= Int InsuDINING/GRE
4.1' 30
0
8 0
240.0 ft2
0
0
0.3
0
8
W
Exterior
Concrete Block- Int InsuDINING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.3
0
9
W
Exterior
Concrete Block- Int Insul KITCHEN
4.1 11
0
8 0
88.0 ftz
0
0
0.3-
0
10
E
Exterior
Concrete Block - Int Insul BATH
4.1 5
0
8 0
40'.0 ft2
0
0
0.3
0
_ 11
N
Exterior
Concrete Block- Int Insul FOYER
4.1 •8,
0
8 � 0
64.0 ft2
0
0
0.3
0
12
N
Exterior
Concrete Block- Intinsul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13
W
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
_ 14
N
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_15
N
Garage
Frame -Wood. BEDROOM3
11 26
8
208.0ft2
0.23
0.3
0
DOORS
#
Omt
DoorType. Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32 '
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/
Wall
Overhang
V/
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation'
IntShade
Screening
1
'S 3
Metal Low-ESingle Yes
1.04 0.29
N
32.4 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exteriors
2
E 5
Metal Low-ESingle Yes
1.04 0.29
N
6.9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-ESingle Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low-ESingle Yes .
1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Prop6sedACH(50) .000254 1168:7 64.16
120.66
.0881
5
4/21 /2020 10:04 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 15
34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
#. System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.97 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName -
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
--- Supply----
---- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6 175 ft2
Attic
55 ft2 DefaultLeakage
Attic
.(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb Mar
HeatinJan f X)j Feb . Mar
A r
f Apr
Ma Jun Jul
f May Jun Jul
Auge
Au[
Sep
Oct . Nov
f Oct x Nov
Dec
Dec
VentingJan [ ]Feb Mar
Apr
[ May Jun Jul
Aug
[ Se
Oct X Nov
Dec.
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType 1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM 78
78. 78
78. 78 78
78
78
80 80 80
80
PM 80
80 78
78 78 78
78
78
78 78 78
78
Cooling(WEH) AM 78
78 78
78 78 78
78
78
78 78 78
78
PM 78
78 78
78 78 78
78
78
78 78 78
78
Heating (WD) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 66
66
Heating(WEH) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68. 68
68 68 68
68
68-
68 68 66.
.66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(81bs/sq.ft.
0 ft2-
Oft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BATH_
Default(81bs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2 '
Default(8lbs/60.ft.
ft2
ft
0.3
DINING/GREAT RO.
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY: CHECKLIST REPORT
MASS
Mass Type
Area Thickness. Furniture Fraction
Space.
Default(8lbs/sq.ft.
ft2 ft 0.3
BATH
Default(8lbs/sq.ft.
ft2 ft 0.3
HALL
Default(8lbs/sq.ft.
ft2 ft 0.3
FOYER .
Default 81bs/s .ft.
W ft 0.3
BEDROOM.3
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402A.1.1
AIR BARRIER AND INSULATION: INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE'COUNTY
City, State, Zip: FT.. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
i
Design Location: FL, Fort Pierce
y
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous. air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any. dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
y Pp g /soffit
the insulation and any gaps in the air barrier shall be sealed.
shall'be aligned with the air barrier.
Access openings, drop down stairs.or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls'
The junction of the top plate'and'the top of exterior walls shall be
shall. be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope.insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall' be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation..
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in: contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the -top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the. building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation. that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls ;adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on.exterior wall
tubs shall separate them from the showers,and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical. or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in,a manner that is recommended by the manufacturer.
Caulking or other adhesive' sealants shall not be.used to fill voidsover plates and -molls or cellin-s.
between fire sprinkler c .
a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400,
4/21/2020 10:05 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition'(2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy.
Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
_
a) Supply ducts R
6.0
2. Single-family or multiple -family
2: Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
34.8
a) Split system. SEER
15.0
5. Is this a worst. case? (yes/no)
5. Yes
b) Single package . SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 1.058
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.285
14. Heating system: Capacity
34.8.
c) Area
7c. 151.4
a) Split system heat pump . HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0'97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood _frame (Insulation R-value)
10A1.
e) Dedicated heat pump with.tank EF
2. Masonry -(Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 11.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and'insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b:
c) Whole house fan
No
c) Knee walls/skylight walls
11c. 19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'`Label required by Section R303.1.3 of the Florida Building Code,, Energy Conservation, if not DEFAULT
certify that this'home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address:of New Home: `'z- yCity/FL Zip: _ FT. PIERCE. FL
41211202010:05:25 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1