Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTrussa
„
i
Y MORE TRUSSES ARE BUILT FOR TEAT' MODEL
A=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
TRUSSES FOR TIE FIRST MODEL HOULD DE SHIPPED AND SUCCESSFULLY SET DE -FORE AN
® ARRANJE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24' IN LENGTH
A Do not F-tand on trusses until they are braced per BCSI & properly nailed to straps ot hangers 1
----
� 15,_3» C L
15'-3”
5QHVINU NOTE
ALL TRUSSES ARE TO BE SET
- AT 2 -O; ON CENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
IF MULTIPLE PLY.
A
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Spanlor less A 30' to 60' Span
60 degrees Spreader Bar
or less
ApProx 2/3 to
1 /2 _� I. Lcg 4-._ _—�
Tog Line span approx.e 1/2 of Span
REFER To BCSI REFER TO BCSI
Truss must be set this way if crane used Truss must be set this way if crone used
T•uss is On exomple your trans may not match This is onexample, truss may not match.
Insist crone operator sets truss this way. Insist crane operator sets truss this way.
�I
SEAT PLATES BY CHAMBERS
77
.I i`GN9IEP lxu.lnu A501MEN510NFD ON 1pYWT
"ANre,
zvac'NC I.
L an"ENJA�12
� ,. - r 4.00 F--
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
M
1,
upset=1/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
12
4.00
— 2.00-
12
Ile
lk
GRA
1
W,
■1011�®�/.I.�I�I�I�®Ivl�l�l�l®I�
I I
%1 1
� se
AT INVERTED "V" WEBS AT CENTER
o W/9' B.C. PANNEL. LOAD W/ (2)
.- qn * Dn,kIT I nAnQ DGD TDI ISSi Fr1D Ar4Nl I
■1111EI
1'r..,
,I�,�I✓/li„i
I�
t�//i/iI/�,li,��.l�
i%I�
upset=1/4" heel=3 15/16" INDICATES LOAD BEARING
PLUMB CUT END REQUIRED BY TRUSSES
SUPPLIED BY BUILDER P
® C
H
2 x 4 Top Chord AT A HEIGHT pF 8' 0" RIGHT
•
1 .I
1
t
1
� 1
�111
I
I
I
1 I
1
1
1
1
1
1
I
ll`
1 1
I I
1
I I
\
WWI
INS
Ills
P'lop-Impons
111111
+j��dompod
® E
PAN
\
SM','� .I ®"ill
,1 .■
INN M.
INS
®
l�
INVERTED -V- WEBS AT CENTER
PER TRUSS FOR A/H
INN
'A\\i
\�`I`\�\I"\\i\\\`i
\\\`I)`\\\\♦i`i\♦C�\`i\``\I\\"\I\`\\\
\`\\I
\\�I\\�\\�♦
i' CLO*� ED AREAS ARE OF
SPECIAL CONCERN & MUST BE t
CHECKED CAREFULLY & MAY
t INDICATE DEVIATION FROM
PLANS..
a
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT Is SIGNED & RETURNED
The legal description of the property where the trusses will be Installed Is:
,The undersigned acknowledge& and agrees:
1: Trusses will be made in strict accordance with this truss placement diagram layout,
which Is the sole authority for dalenniningsuccessful fabdcatlon of the trusses.
dimensions In this layout
e out have be v 2.All d an edfi Y ed b the undersigned,
Y
leas written nohce b rovlded b co .3. Unless nlned mall D to Chambers Truss
Y N within
ten (10)
days of delivery the undersigned agrees that no backchargas will be allowad.ln the event
such written no0co la fumishad Chambers Trueas a ve three (3) bu pass days In which
airs required, or to substitute
to begin rep q other Wsses, et Chambers op0on.L
4, Tha undersigned acknowledges receipt of "BCSI 1-03" summary sheet by'rPI & WTCA.
5, Delivery Is to Job site. It Is the buyer's'responsibillty to make the Job site suitable for
delivery. Chambers Truss has the sole authodty to detertnlne the sultablllly of the Job site or a
f e job alte for delivery, Chambers
frier o th ere Truss will be responsible for portion I ry p dump delivery only.
The boyar Is responsible for additional delivery expenses if Chambers Truss has to redeliver
because job she Is riot prepared for delivery or buyer Is not prepared for delivery of trusses,
9uyer fs responsible to Chambers Truss for towing casts due to she conditions,
S. Pike as shown Iq paragraph 7 below Is subject to change If any changes ere, made 14
this. iayou4 A $50 per hour fee for revisions may be charged by Chambers Truss,
.7. This IS a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If nei
agreement a reasonable price. Invoice will be made on delivery and paid within terms of not
on delivery. Invoice may, be made at scheduled date of delivery 9 buyer cannot accept
delivery of fabricated trusses. The undersigned agrees to pay Chambera.Truss reasonable
ahomail fee for collections In event of payment not timely made. 1-1/2 % per month servjce
charge will be added for all sums not paid within terms.
a. Signature or Initials anywhere on this sheet constitutes agreement to all terns herein.
San consideration of Chambers Truss extending credit for this matedal the undersigned
unconditionally guarantees payment when due of any and all Indebtedness owed to
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Inclu=4ng ahomeys fees. If default In payment for material be made by the
recipient. 1.
10. in the event of any gggation concerning this agreement, the Items furnished hereunder
or payments referred to herein, the, parties agree that the sole venue for any such action will
be Saint EOcle County, Florida.
11. Design responslb111Ues are per "National Standard And Recommended Guidelines On
Rasponslbl'l For ConsWedon Using Metal Plate Connected Wood Trusses
ANSI/TPVWTCA 4-2002"'.
DATED .^;•�.
SIGNED
F,ORTITLE •. - _
Aspteader barmay be ret LOW per "BCSI 1.W` to prevent injury & damage•
Multiple ply trusses must be fastened togethar per engineering
before they are sot failure to do so can result In roof collapse.
Temporary and permanent bracing are required and can save life
and property and Is the responsibility of the truss erector.
Study the contents of the Information packet Included on delivery
before setting trusses.
Trusses must be setand braced per design to prevent INUry &I damage.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any
other concentrated loads on trusses, this can cause collapse.
DO,NOT SET TRUSSES USING THIS LAYOUT `
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES I
CHAMBERS TRUSS 11AICS
3105 Oleander Avenue
Fort Plercej Florida 34982-6423
800-551-5932
Fort Pierce 772-465-2012 Fax 772-465-8711 '
Vero Beach fi72-5694022s Stuart 772-286-3302 '
or. Architect's represen
rover
shop drawing appis M tative's
en
"double check" of the contracto 1
The Of
shalt remain responab�e
for checking .field measurements a d
other cunseructi(m criteria. Architect.
iewapprof tru oval suers general roof shapei
nevi
strapping, and loadin� oM
structure from gravif !-
their re a I've dUplit loads l,a tl
*10e1,,0T,Apprved aDate
92.0/93.2 MITEK 4.2 6ratlen & Braden A.1•A• P.A.
DESIGN CRITERIA
County SAINT LUCIE
%foIip'k.l;704,,0'Z .. Building Department ST LUCIE COUNTY
C. 0 1 "� Wind Design Criteria ASCE 7-2010
Ac
Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
cg Roofing Material Shingle or Shake
0I p;lr� I Loading in PSF Roof R.D.L.
Top Chord Live 20
o Top Chord Dead 7 4.2
r, I Bottom Chord Live 10 Non-Concurme t
o c Bottom Chord Dead 10 3
to I TOTAL Load 37 7.2
Is � Duration Factor 1.25
> Wind Speed 165mph
cc
LA Top Chord C.B. Sheeting by builder"
Bottom Chord C.B. Sheeting by builder.
3 Highest Mean Height 151-00
� Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
R.D.L:=Restrainin Dead Load C.B =Continuous Brawn
Verify DESIGN CRITERIA shown above with the
4
building department and your engineer.
Design Criteria is the responsibility of the
Buildin Designer and/or Engineer of Record.
Chambers Truss Inc. Drawing Name: M11392
Scale: 1 /4 = 1'
ILU 82 total trusses, 15 different trusses.
MI 4: RLC ACAD: RLC Reviewed :
B
I� y
I FOR
Revised: 3/05
Date: Revised:03/21/1
I(� i�o2o
6'-4" L 14'-4" - _ � WYNNE BUILDING CORP.
l
PORCH LEFTDESCRIPTION:
Z> WINDSOR
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE D of
15 TRUSS DRAWINGS ARE ATTACHED TO LKY'OUT M 11392
mm
N81 0
MiTek'
RE: M11392
THE WINDSOR
Site Information:
Customer: Wynne Dev Corp
Lot/Block:
Address: unknown
City: St. Lucie County
(z� Q��\P
Project Name: M11392
Model: THE WINDSOR
Subdivision:
State: FL
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
1
T19781803
A
9/23/2020
2
T19781804
Al
9/23/2020
3
T19781805
A2
9/23/2020
4
T19781806
A3
9/23/2020
5
T19781807
A4
9/23/2020
6
T19781808
A5
9/23/2020
7
T19781809
ATA
9/23/2020
8
T19781810
B
9/23/2020
9
T19781811
BHA
9/23/2020
10
T19781812
GRA
9/23/2020
11
T19781813
J1
9/23/2020
12
T19781814
J3
9/23/2020
13
T19781815
J5
9/23/2020
14
T19781816
J7
9/23/2020
15
T19781817
KJ7
9/23/2020
This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
����� r t r �ri��
MiTek USA, Inc under my direct supervision �
S Abased on the parameters provided by Chambers Truss. ,���O�PA4e,i��i
Truss Design Engineer's Name: Albani, Thomas �`�.j`•.��c, E Ng�.:9,L����'
My license renewal date for the state of Florida is February 28, 2021.
Florida COA: 6634 No 39380
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
:1 STATE OF :•��
iO 4ll-
&S�ON A� ,�� .�`,,
Thomas A. Albani PE No.39380
Mfrek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610 September 23, 2020
1 of 1 Albani, Thomas
r
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781603
M11392
A
HIP
1
1
Job Reference (optional)
L,namoers I russ, Inc., rori rlerce, rL ^�
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-KTRK2jb7uXlhmgejemLw33G2phzq_UFBTsBBV6zXjH_
10-0 610-14 9-0-0 14-11-0 20-2-13 26-0-0 28-1-2 35-0-0
-0-0 6-10-14 2-1-2 5-11-0 5-3-13 5-9-3 2-1-2 6-10-14 -0-0
4x8 = 2x3 II
4.00 12
2x3 4 26 5
3x6 = 4x4 = 4x8 = 2x3
6 7 27 8 9
Scale = 1:60.5
17 16 15 14 13 12
3x4 = 3x4 3x6 — 6x8 = 3x4 = 3x6 — 3x4 = 3x5 —
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.57
Vert(LL)
0.42 12-23 >572 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.47
Vert(CT)
0.37 12-23 >659 180
BCLL 0.0
Rep Stress Incr
YES
WB 0.94
Horz(CT)
0.03 10 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 161 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-5-1 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0
Max Horz 2=-97(LC 10)
Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12)
Max Grav 2=467(LC 17), 15=1596(LC 1), 10=685(LC 22)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-639/108, 3-4=396/0, 4-5=-967/776, 5-7=-967/776, 7-8=-454/938, 8-9=-1009/1884,
9-10=-1265/2154
BOT CHORD 2-17=0/652,15-17=0/430,14-15=-704/454,12-14=-1586/938,10-12=-1971/1174
WEBS 3-17=372/461, 4-17=272/451, 4-15=-1087/1002, 5-15=-336/386, 7-14=-766/399,
8-14=-580/997, 8-12=-958/447, 9-12=-358/600, 7-15=-1329/2190
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to
13-11-6, Interior(1) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for
This item has been
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
electronically Signed and
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Albani, Thomas, PE
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at
Printed copies of this
P
joint 15 and 799 lb uplift at joint 10.
document are not Considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall HTbuilding design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781804
M11392
Al
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:08 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-of?iF3blfgtYOgDv7Us9cGoCh5CAjz5KiVwkOzzxjGz
8.6-0 11-0-0 14-9-0 i 19-8-14 24-0-0 27-4-7 35-0-0 $6-0-q
-0-0 8-6-0 2-6-0 3-9-0 T 1-14 4-3-2 3 4 7-7-9 -0-0
�1
6
3x6 =
4.00 12
1.1 '\
5x6 =
2x3 11
21 5
3x4 =
6 22
13 12
3x5 = 5x8 MT18HS =
2.00 12
5x8 MT18HS =
Scale=1:61.3
3x12 Zz
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (Icc)
I/defl
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.63
Vert(LL)
0.75 11-12
>563
240
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.91
Vert(CT)
-1.21 11-12
>348
180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WB 0.77
Horz(CT)
0.35 9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 155 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-117(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
Max Grav 2=1349(LC 1). 9=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3209/2102, 3-4=-3006/2024, 4-5=-3022/2080, 5-6=-3022/2080, 6-7=-4643/2994,
7-8=-5324/3364, 8-9=-5751/3700
BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478
WEBS 3-13=-425/410, 4-13=-354/571, 4-12=-362/617, 5-12=-269/279, 6-12=-1034/712,
6-11=-373/892, 7-11=-897/1523, 8-11=404/435
Structural wood sheathing directly applied or 2-7-7 cc purlins.
Rigid ceiling directly applied or 2-2-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 9.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall MiTek*
design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Ply
THE WINDSOR
T19781805
M11392
A2
SPECIAL
�Qty
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:09 2020 Page 1
ID: _kfiGCA6bx7j2Syl HDXFw7ye3KX-HsZ4SPcOQ8?P?zo5hBOOBULMuVYnSPxUx9glY?zXjGy
1-0-0 8-6-0 13-0-0 14-9-0 22-0-0 27-0-7 35-0-0 6-0-
-0-0 8-6-0 46-0 1-9-0 7-3-0 5-4-7 7-7-9 -0-0
4.00 12
3x6 =
30 =
LOADING (psf) SPACING- 2-0-0
TCLL 20.0 Plate Grip DOL 1.25
TCDL 7.0 Lumber DOL 1.25
BCLL 0.0 Rep Stress Incr YES
BCDL 10.0 Code FBC2017/TP12014
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 8=0-8-0
Max Horz 2=136(LC 11)
Max Uplift 2=-825(LC 12), 8=-825(LC 12)
Max Grav 2=1349(LC 1). 8=1349(LC 1)
5x6 = 3x4 =
4 21 5
12
5x8 =
2.00 12
5x8 =
22 6
24-6-8
Scale = 1:61.3
3x12 zz
CSI.
DEFL. in (loc) Udefl L/d
PLATES GRIP
TC 0.66
Vert(LL) 0.72 10 >585 240
MT20 244/190
BC 0.95
Vert(CT)-0.9410-19 >447 180
MT18HS 244/190
WB 0.86
Horz(CT) 0.34 8 n/a n/a
Matrix -MS
Weight: 160 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3211/2064, 3-4=-3017/1998, 4-5=-2580/1800, 5-6=-3379/2225, 6-7=-5242/3250,
7-8=-5759/3665
BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=-1990/3441,
8-10=-3410/5485
WEBS 3-13=420/418, 4-13=-427/688, 4-12=-337/551, 5-12=-777/605, 5-11=-465/925,
6-11=-391/277, 6-1 0=-1 318/2268, 7-10=-503/530
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extefior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) *This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 8 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 8.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design Into the overalls
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criterla, DSO-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oly
Ply
THE WINDSOR
T79781806
M11392
A3
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:10 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-127SgidOBS7Gd7N IFvvehhuYXvu2Bsnd9pPr4"Gx
1-0-0 8 6-0 15-0-0 20-0-0 24-6-8 27 4-7 35-0-0 6-0
-0-0 B-6-0 6-6-0 5-0-0 4-6.8 2-9-15 7-7-9 -0-0
Scale = 1:62.3
�1
0
4.00 12
14
3x5
2x3 I[
=
5x6 = 4x5 =
13
5x6 =
2.00 12
20-0-0
3x12 Zz
rn
0 - n
0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deb Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.60
Vert(LL)
0.73 11 >572 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT) -0.97 11-20 >432 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.83
Horz(CT)
0.36 9 We n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 7-12
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-155(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
Max Grav 2=1349(LC 1), 9=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2.4=-3256/2031, 4-5=-2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=-5320/3257,
8-9=-5720/3554
BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=2935/5103,
9-11=-3302/5445
WEBS 4-14=0/329,4-13=-897/636, 5-12=-316/661,6-12=-317/616, 7-12=-2727/1643,
7-11=-1072/1939,8-11=-390/391
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1 -0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 9.
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and SCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33810
Date:
March 24,2020
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781807
M11392
A4
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
4.00 12
2.3
5x6 = 4x6 =
6 7
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:112020
6-6-8 2-9-15
Scale=1:62.3
rn
2
Im
d
16 15 6x10
3x5 = 2x3 II 5x8 = 3x12 =
2.00 12
24-6-8
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017f rPI2014
CSI.
TC 0.59
BC 0.95
WB 0.98
Matrix -MS
DEFL. in
Vert(LL) 0.80
Vert(CT) -1.05
Horz(CT) 0.39
(loc) I/deft Ud
13 >528 240
13 >400 180
11 n/a - n/a
PLATES
MT20
MT18HS
Weight: 172 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-14 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 8-14
REACTIONS. (size) 2=0-8-0, 11=0-8-0
Max Horz 2=-175(LC 10)
Max Uplift 2=-825(LC 12), 11=-825(LC 12)
Max Grav 2=1349(LC 1). 11 =1 349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3253/1989, 3-5=-2435/1560, 5-6=-2399/1639, 6-7=-2217/1501, 7-8=-2380/1519,
8-1 0=-5361/3228, 10-11 =-5716/3480
BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-292015154,
11-13=-3232/5441
WEBS 3-16=01334, 3-15=-882/614,5-15=-238/254,7-14=-163/427,6-14=-309/604,
6-15=-315/409, 8-14=-3146/1901, 8-13=-1034/1946, 10-13=-343/333
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
This item has been
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
electronically signed and
4) All plates are MT20 plates unless otherwise indicated.
sealed by Albanl, Thomas, PE
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed copies of this
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
document are not considered
capacity of bearing surface.
signed and sealed and the
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signature must be verified
joint 11.
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall A�•
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 V1iTe k•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781808
M11392
A5
SPECIAL
16
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 6.z4u s mar 9 zuzu mi i eK industries, inc. I ue Mar 24 12:54:13 2020 rage 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-9dpbinfuTNVrUb6twl SLJKWOV6vFOEp3rneVhmzXjGu
1-0-0 8-6-0 14-9-0 17-6-0 24-6-8 27-4-7 35-0-0 6-0-
-0-0 8-6-0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 _0
Scale = 1:60.3
�1
6
3x5 =
4.00 12
14 13
2x3 11 5x10 =
5x8 MT18HS 11
2.00 12
3x12 zz
1
I� IT
0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defi Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.81
Vert(LL)
0.80 12-13 >526 240
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.92
Vert(CT) -1.28 12-13 >329 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WB 0.74
Horz(CT)
0.36 10 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 'Except'
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
purlins.
1-4,8-11: 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP M 30
WEBS
1 Row at midpt 6-12
WEBS 2x4 SP No.3 *Except*
6-12: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-825(LC 12), 10=-825(LC 12)
Max Grav, 2=1349(LC 1), 1 0=1 349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=-2397/1763, 6-7=-5452/3624, 7-9=-5398/3482,
9-10=-5732/3689
BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, 12-13=-1223/2137, 10-12=-3431/5459
WEBS 3-14=01303, 3-13=-861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526,
7-12=-323/388, 9-12=-321/306
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber. DOL=1.60 plate grip
DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL=10.Opsf.
6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Nil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not -
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall �Ay
building design. Bracing indicated is to prevent budding of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSl7fp/f quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T19781809
M11392
ATA
COMMON
5
1
�THEWINDSOR
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. TUB Mar 2412:54:14 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KK-dpMzW7gWEgdi6lg3UkzarX2EkWJA7jTD4RN3DCzXjGt
i1-0-0 8-4-0 12-11-0 17 6-0 , 22-1-0 26' -0 35-0-0 6
008-4-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 y-0-0
4.00 12
4x5 =
Scale = 1:59.5
I �
0
17 — 15 "" "' 14 12
3x6 — 2x3 II 4x6 = 3x8 = 2x3 II 3x6 =
3x8 = 4x6 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0 '
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017rrP12014
26-8-0
CSI.
DEFL.
in (loc)
Udefi
Ud
TC 0.59
Vert(LL)
0.33 14-15
>999
240
BC 0.68
Vert(CT)
-0.64 14-15
>652
180
WB 0.59
Horz(CT)
0.13 10
n/a
n/a
Matrix -MS
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-775(LC 12), 10=-775(LC 12)
Max Grav 2=1399(LC 1), 10=1399(LC 1)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=-2801/1739, 7-9=-2807/1637,
9-10=-3404/1963
BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188,
10-12=-1739/3188
WEBS 6-14=-560/968,9-14=-681/524, 6-15=-560/968,3-15=-681/524
PLATES GRIP
MT20 244/190
Weight: 166 lb FT = 0%
Structural wood sheathing directly applied or 3-1-15 oc purlins.
Rigid ceiling directly applied or 5-2-15 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterlor(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at
joint 10.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUrPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781810
M11392
B
COMMON
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:15 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-50wLjSh87_IZuFF2SVpOlbSRwk4sA4MJ57cmfzXjGs
�1-0-0 8-3-5 14-0-0 17-6-0 21-0-0 26-8-11 35-0-0
-0-0 8-3-5 5 8-11 3.6-0 3-6-0 5 8-11 8-3-5
Scale = 1:59.3
�1
O
4.00 12 3x6 =
3x4 = 2x3 II 3x6 = 3x4 = 3x4 = 3x6 = 2x3 II 3x4 =
8-3-5 14-0-0 21-0-0 261-111 35.0-0
8-3-5 5-8-11 7-0-0 5-B-11 8-3-5
Plate Offsets (X Y)— [2:0-2-6,Edge] [6:0-3-0,Edge], [10:0-2-6,Edge]
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.34
TCDL
7.0
Lumber DOL
1.25
BC 0.38
BCLL
0.0
Rep Stress Incr
YES
WB 0.63
BCDL
10.0
Code FBC20171TPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
I N
I�
O
DEFL.
in (loc)
Udefl
L/d
PLATES GRIP
Vert(LL)
-0.11 14-15
>766
240
MT20 244/190
Vert(CT)
-0.24 17-20
>715
180
Horz(CT)
0.03 10
n/a
n/a
Weight: 149 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied.or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-179(LC 10)
Max Uplift All uplift 100 lb or less atjoint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC
12)
Max Grav All reactions 250 lb or less atjoint(s) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC
1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-945/572, 5-6=-181/256, 6-7=-181/258, 9-10=-945/574
BOT CHORD 2-17=-407/878, 15-17=407/878, 12-14=-393/858, 10-12=-393/858
WEBS 3-17=-5/301, 3-15=-819/591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592,
9-12=-5/301
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interlor(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at
joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10.
®WARNING - Verily, design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781811
M11392
BHA
BOSTON HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MjTek Industries, Inc. Tue Mar 2412:54:17 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
15-6-0 21-64)
1-0-0 7-0-0 13-01-0-CO 719-236-0 256-0 28-0-0 3-001-0620-0-0 -0091-0 O17-M 2 2-02-0 -0
-0-0
Scale =1:62A
TOP CHORD MUST BE BRACED BY END JACKS,
ROOF DIAPHRAGM, OR PROPERLY CONNECTS 4.00 12 4x4 =
PURLINS AS SPECIFIED.
57 15 58 17
56 12 59
3x6 55 9
548
5x12 =53 4 6 x6
3 11
52 11 14
35 42 43 34 44 � 45
3x6 = 6x8 =
3x4 =
20
60 22 3x6
3x4 2,01 26 5x12
16 19 1 23 627
46 47 48 - 49 31 50 51
6x8 = 3x6 =
21-0-0
30
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Well
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.51
Vert(LL)
0.13 35-38
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.54
Vert(CT)
-0.16 35-38
>999
180
BCLL 0.0
Rep Stress Incr
NO
WB 0.65
Horz(CT)
0.04 28
n/a
n/a
BCDL 10.0
Cade FBC2017rrP12014
Matrix -MS
Weight: 208 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc pudins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at micipt 3-33, 27-32
JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=179(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8),
28=-434(LC 8)
Max Grav All reactions 250lb or less atjoint(s) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1),
28=626(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1692/1103,3-4=-105/259,27-28=-1129/710,3-5=-441/520,5-7=-436/514,
7-10=436/514, 10-11=-436/514, 11-13=-436/514, 13-16=-436/514, 16-18=-436/514,
18-19=436/514,19-21=-382/412,21-23=-382/412,23-25=-382/412,25-27=-387/418
BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039
WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=-810/782, 19-32=772/745,
27-32=-1484/1044, 9-10=463/453, 20-21=-462/454
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at
joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28.
8) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at
7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb
down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206
lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at
25-11-4, and 158 lb down and 206 lb up at 27-11-4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69
lb down at 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at
19-11-4, 69 Ib down at 21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 69 lb down at 27-11-4 on bottom chord.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
-- The desi nlselection of such connection devices is the yes onsibili - of others. -- --`- -- --- _
®G'Q 2trYtt#eVr#11 sfgA)6e8llad�,imBGtSrapp11e71i920faCeMbbeIM3S&WBMalEdF& frMt7R)Q&bR QMBEFORE USE.
DGMt?AWdrgpp 6v2h MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a trp y�t@wJ� s4��gtyng designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
buifd�d'es�h:911. iirdEi 'aiLttfl3''to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781811
M11392
BHA
BOSTON HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2U20 MITeK InaustneS, Inc. I ue Mar 24 12:b4:1 f 2U2U rage 2
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
Vert: 36-39=-20, 1-3=-54, 3-15=-54, 15-27=-54, 27-29=-54
Concentrated Loads (lb)
Vert: 35=-373(F) 30=-23(F) 42=-23(F)43=-23(F) 44=-23(F) 45=-23(F) 46=-23(F)47=-23(F) 48=-23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F)
54=-118(F) 55=-118(F) 56=-118(F) 57=-118(F) 58=-118(F) 59=-118(F)60=-118(F) 61=-118(F) 62=-118(F) 63=118(F)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall q�
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Mel(
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PI1 quality CNterla, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781812
M11392
GRA
HIP
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1
ID: _kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvQzxjGo
1-0-0 7-0-0 14-11-0 21-5-2 26.0.0 35-M 6-0
-0-0 7-11-0 6-6-2 6-6-14 7-0.0 -0-0
Scale = 1:60.3
5x12 MT18HS =
4.00 12 3x5 II 3x6 = 4x8 = 4x8 =
3 22 23 24 25 4 26 27 5 28 629 30 31 32 7
2 8 9
15 33 34 14 35 13 36 37 38 1239 11 40 41 10
3x4 = 2x3 II 3x6 = Sx14 = 3x4 = 4x6 = 2x3 II 3x5 =
7-0-0 14-11-0
21-5-2
i 28-0-0 35-M
i
7-0-0 7-11-0
6-6-2
6-6-14 7-0-0
Plate Offsets (X,Y)—
[3:0-9-0,0-2-8],[6:0-3-8,0-2-0] [7:0-5-4,0-2-4] [13:0-4-0,0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defi Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.94
Vert(LL)
0.30 10-21 >792 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.67
Vert(CT) -0.30 10-12 >812 180
MT18HS
2441190
BCLL 0.0
Rep Stress Incr NO
WB 1.00
Horz(CT)
0.09 8 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 153lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-9-5 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-6-8 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at micipt 6-13
4-13: 2x6 SP No.2
2 Rows at 1/3 pts 3-13
REACTIONS. (size) 2=0-8-0, 13=0-8-0, 8=0-8-0
Max Horz 2=-78(LC 6)
Max Uplift 2=-448(LC 8), 13=-2442(LC 8), 8=-1159(LC 8)
Max Gram 2=755(LC 17), 13=3223(LC 1), 8=1225(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1534/729, 3-4=-105211347, 4-6=-105211347, 6-7=-1946/1834, 7-8=-2978/2565
BOT CHORD 2-15=-586/1423, 13-15=-596/1464, 12-13=-1710/1946, 10-12=-2359/2830,
8-10=-2329/2789
WEBS 3-15=-159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=-3504/3050, 6-12=-430/666,
7-12=-940/731, 7-10=489/690
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at
joint 13 and 1159 lb uplift at joint 8.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at
7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down
and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-11-4, 90 lb down and 155 lb up at
19-11-4, 90 lb down and 155 lb up at 21-114, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-114, and
203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb
down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at
17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-11-4, 63 lb down and 3 lb up at 21-11-4, 63 lb down and
3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
®k QAMG'ASFn(S+ksI$taundalt&rs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5119/2020 BEFORE USE.
De19rI6A ardIgaWeNiJh MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Bet re Use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Chiteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
0904 Parke East Blvd. Tampa FL 33810
Date:
March 24,2020
let
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781812
M11392
GRA
HIP
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
ts.Z4D S mar u ZUZU mi I eK Incusmes, Inc. I ue mar Z4 iz:Y#:-i a AvAu rage z
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvQzXjGo
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-7=-54, 7-9=-54, 16-19=-20
Concentrated Loads (lb)
Vert: 3=-147(B) 7=-147(B) 15=-452(B) 13=-40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=-90(B) 28=-90(B) 30=-90(B) 31=-90(B)
32=-90(B) 33=-40(B) 34=-40(B) 35=-40(B) 36=-40(B) 37=-40(B) 38=-40(B) 39=-10(B) 40=40(B) 41=-40(B)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and properly, damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
MiTek°
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T19781813
M11392
J1
MONO TRUSS
8
1
�THEWINDSOR
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2UZU Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYblBwXAho7vyEj5gvQ2XjGo
-1-0.0 1-0-0 i
1-0-0 1-0-0
3x4 =
Scale = 1:6.1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) -0.00
5 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=48(LC 12)
Max Uplift 3=-4(LC 9), 2=-140(LC 12)
Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. ��
Design valid for use only with Mrrek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall MiTek*
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iTe k•
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the iUl
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPN Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T19781814
M11392
J3
MONO TRUSS
8
1
�THEWINDSOR
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:20 2020 Page 1
I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-SzkEmAIHgWOrgg8Dq?4_5olMZxUHXa95SNgNRszXjGn
3-0-0 i
1 A-0 3-0-0
Scale = 1:9.4
3x4 =
r
3-0-0
3-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. In
(loc) I/defl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) 0.01
4-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.19
Vert(CT) -0.01
4-7 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 11 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=85(LC 12)
Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12)
Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33810
Data:
March 24,2020
®WARNING - Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall MOW
t
building design, Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing " OW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty,
Ply
THE WINDSOR
T79781815
M11392
J5
MONO TRUSS
8
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
-1-0-0
3x4 =
5.24U s Mar 9 2020 MI I eK Inoustnes, inc. I ue Mar 24 i2:54:2i 2020 rage 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrOoKiYG1 PFhlawzlzXjGm
5.0-0
5-0-0
Scale = 1:12.7
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefi L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.73
Vert(LL) 0.07
4-7 >863 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.70
Vert(CT) -0.06
4-7 >964 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MP
Weight: 17 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc puffins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=123(LC 12)
Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12)
Max Gram 3=115(LC 1), 2=243(LC 1), 4=87(LC
3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd, Tampa FL 33610
Data:
March 24,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing
MiTek'
isalways required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781816
M11392
J7
MONO TRUSS
24
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
-1-0-0
3x4 =
8.240 s Mar 9 2020 MiTek Industries, Inc. TUB Mar 24 12:54:212020 Page 1
ID:_kflGCA6bx7j2Sy1HDXFw7ye3KX-wAHc WlvbgWiRpjPOibDeOrSnKmPG1PFh1awzlzXjGm
7-0-0
7-0-0
7-0-0
Scale: 3/4-=1'
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Udefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.47
Vert(LL)
0.17
4-7
>494
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.39
Vert(CT)
-0.19
4-7
>447
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=161(LC 12)
Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC 12)
Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interjor(1) 2-6-0 to 6-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at
joint 2 and 12 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Alban!, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
March 24,2020
®WARNING - Verifydesign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119t202O BEFORE USE. R
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not q -
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MIT®k*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIf7PH quality Criteria, DSB•89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781817
M11392
KJ7
MONO TRUSS
4
1
Jab Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:22 2020 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-OMr BsmXM7eZ3zIbyQ7SADNhnk9g7RvOwhJUWIZXjGI
-1-5-0 6-8-12 9-10-1
11� 6-8-12 3-1-5
3x4 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TP12014
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanicai, 2=0-11-5, 5=Mechanical
Max Horz 2=192(LC 8)
Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=238(1_C 8)
Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1)
Scale = 1:20.6
5
3x4 =
CSI.
DEFL. In (loc) Udefi Lid
PLATES GRIP
TC 0.20
Vert(LL) -0.04 7-10 >999 240
MT20 244/190
BC 0.26
Vert(CT) -0.08 7-10 >999 180
WB 0.24
Horz(CT) 0.01 5 n/a n/a
Matrix -MS
Weight: 38 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD . Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-838/366
BOT CHORD 2-7=-487/798, 6-7=-487/798
WEBS 3-7=0/307, 3-6=-920/561
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at
joint 2 and 238 lb uplift at joint 5.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-4=-133(F=-39, B=-39), 8=0(F=10, B=10)-to-5=49(F=-15, B=-15)
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd, Tampa FL 33610
Date:
March 24,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall my
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Symbols Numbering System ® General Safety Notes
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
0-' i r
For 4 x 2 orientation, locate
plates 0- 'lid' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI(rPl1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
lY
O
2
U
a.
O
F-
6-4-8 dimensions shown in ft-in-sixteenths
11 (Drawings not to scale)
2 3
TOP CHORDS
8 7 6 5
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek@ All Rights Reserved
Bill 0
MiTek 0
MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or pudins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSUTPI 1 Quality Criteria.
21.The design does not take into account any dynamic
or other loads other than those expressly stated.