HomeMy WebLinkAboutEnergy Code''FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CARLTON IMPACT
Builder Name: WYNNE BUILDING COPR.
Street: -b-TA �, �}Q CS�
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location:. FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9.. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.60 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 sqft. )
insulation • Area
a. Under Attic (Vented)
R=30.0 1446.00'ft2
6. Conditioned floor area above grade (ft2) 1446
'b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
12= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a.'Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor:Sol, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/h.r Efficiency
SHGC: SHGC=0.27
a. Central Unit
34A SEER:15.00
c. U-Factor; N/A ft2
SHGC:
.13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft:
Area Weighted Average SHGC:. 0.284
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap: 50 galloons
a. Slab -On -Grade Edge Insulation k=0.0 1445:50 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 47.47
Glass/Floor Area: 0.098
c
PASS
ASS
Total Baseline Loads: 48.09
I hereby certify that the plans•and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
'
calculation indicates complianceirf'
'�►
with the Florida Energy Code.
PREPARED BY; -
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
- t
I.herebycertify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code..
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: "
DATE:
- compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies -as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an. Air Barrier. and Insulation Inspection Checklist in accordance with R40.2.4.1.1 and -this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/21/202010:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORMR405=2017 .INPl1T.S11MMAI*Y nwp:rK1'I-QT RFPnRT
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User .
Conditioned Area: 1446
Lot # -
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst.Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:.
St. Lucie .
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family.
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter /Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1446 11568
SPACES,
Number Name
Area Volume Kitchen Occupants
Bedrooms.
InfilID Finished Cooled
Heated
1 BEDROOM
301 2408 No
0
1
1 Yes
Yes
Yes
2 WIC
63 504 No
0
1 No
Yes
Yes'
3 M:BATH
56 448 No
0
1 Yes
Yes
Yes-
4 KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY.
55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space. Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
___ .
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
___
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
____
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
____
0 1
0
5 Slab-OrnGrade Edge Insulatio
BATH 5 ft 0
45 ft2
____
0 1
0.
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
__
.0 1
.0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
____
0 1
0
4/21/202010:27 AM EnergyGauge®.USA 6.0.02 (Rev. 1) - FlaRes2017. FBC 6th Edition (2017) Compliant Software . Page 2 of 5
FORM R465-2017 INPUT SUMMARY'CHECKLIST RFPART
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile ' Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0
42 ft2
____
0
1 ,
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
.0
1
0
ROOF
/ Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood'
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee.Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Cavity Width
a ()rnt To Wall Type SpaceEt
Height
n Ft n-
Area
Sheathing Framing Solar Below
o
1 NE=>SW Exterior Concrete Block - Int InsuBEDR00M
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM
4.1 14
0 8
0
112.0 ft2
0.
0
0.4
0
4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2 .
0
0
0.4
0
5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW Exterior Concrete Block - Int InsBIEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
_ 7 SE=>NW Exterior Concrete Block - Int InsBEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block - Int InsBIEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Int InsMEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Int Insul ENTRY'
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
_ 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft2..
0
0
0.4
0
13 NE=>SW Exterior Concrete Block - Int Insi0.REAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Int InsiG6REAT/DINI
4.1 20
0 8
0
166.0 ft2
0
0
0.4
0
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes201T FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY I('_141=CKI IST IRIFPnPT
WALLS
Adjacent
it C)rnf To Wall
Type
Cavity Width Height
Space
Sheathing Framing Solar Below
_ 15 N=>S Garage Frame - Wood
KITCHEN 11 24 8 192.0 ftz'
0.23 0.4
0
DOORS
# Omt
Door Type
Space Storms U-Value
Ft
Width Height
In Ft In
Area
1 SE=>NW ,
Insulated
ENTRY None .39 3
1 6 8
20.6 ft?
WINDOWS
Orientation shown.is the entered orientation. => chan ed to Worst Case..
/ Wall
# Ornt ID Frame
Panes
Overhang
NFRC U-Factor SHGC Imp ` Area Depth Separation Int'Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE.4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 'NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes 1.04 0.29 Y 32.9 ft' 1 ft 0 in
Yes 1.04 0.29 Y 6.9 ftz 1 ft 0 in
Yes 1.04 0.29 Y 24.0 ftz 6 ft 0 in
Yes 1.04 0.29 Y 37.5 ft' 1 ft 0 in
Yes 1.1'1 0.27 Y 40.0 ftZ 8 ft 0 in
1 ft 5 in Drapes/blinds
1 ft 5 in None
1 ft 5 in None
1 ft 5 in. None
.1 ft 5 in Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1 315ft2
315ft2 24ft 8ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50) .000356
1349.6 74.09' 139.34 .1233
7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split Singl HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split Singl SEER: 15 34.8 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
#. System Type
SubType
Location EF Cap Use SetPnt
Conservation
1 Electric:
None
Garage 0.97 50 gal 60.9 gal 120 deg
None
4/21/2020 10:27 AM EnerggGauge® USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPIIT Sl lMMAI2V r-14F:(%ICII_cr Q=onQT
SOLAR -HOT WATER SYSTEM
FSEC
Collector Storage
Pert # Company Name
System Model # Collector Model
#
Area Volume
FEF
None None
ft2
DUCTS
/ -- Supply
----
--- Return --
Air
CFM 25 CFM25•
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT QN RLF
Heat Cool
1 Attic
6 175 ft2
Attic .
65 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES.
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating Jan Feb
Venting
Mar
Mar
Apr
Apr.
May.
May
Jun r Jul
Jun" I Jul
Au
AuL
Se [ �Oct r ,Nov.
Sep [ ] Oct [X]
Nov
Dec
f X� Dec
Jan . Feb
Mar
Apr
L
[
May
Jun [[[ Jul
Aug
[
Se Oct [
Nov
[ ] Dec
Thermostat'Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling-(WD) AM
PM
78
80
78
80
78
78
78
78
78 78
78
78
80 .80
80
80
78 78
78
78
78 78
78
78
Cooling (WEH) AM
PM
78
78
78
78
78
78
78
78
78 78
78
78
78 78
78
78
78 78
78
78
78 78
.78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 88
68
68
PM
68
68
68
68
68 68
68
68
68, 68
66
66
Heating (WEH) AM
PM
66
68
66
68
66
68
66
66 68
68
68
68 68
68
68
68
.68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft..
ft2
ft.
0.3
WIC
Default(8 Ibs/sq.ft.
ft?
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3 '
LAUDRY
Default(8 Ibs/sq.ft.
ft2,
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2,
ft
0.3
DINING/GREAT R
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.,
ft2
ft
0.3
FOYER
Default 8 lbs/s .ft.
ft2
ft
0:3
BEDROOM-1'
4/21/202010:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017.- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER -AND INSULATION: INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE ; FL, Permit Number:
,c
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION• INSTALLATION CRITERIA
General
A• continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
g /soffit
the insulation and any gaps in.the air, barrier. shall be sealed.
shall be alignedy air
with the, ar barrier.
Access. openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
Walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and,framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be In contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom. to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall rbe sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
S.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,' or insulation that on
installation readily conforms to available space shall
extend behind piping and worong-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope -shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids .
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400:
4/21/202010:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software ' . Page 1 of 1
' 2tl9 7 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Peliformance Index, the. more -efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if -multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system. SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single.package , SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6..
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF .
8.5.
b) Single'package Beat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f)-Other
9. Floor type, insulation level:
a) Slab-on-grade'(R-value)
9a.
0.0
b) Wood,. raised (R-value)
9b.
1.5. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry -(Insulation R-value)
10A2.
4.1
f) Heat recovery unit- HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
- 11.0
2. Masony (Insulation R-value)
16132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type. and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation,
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving.features which will be installed (or exceeded):in this home before final inspection. Otherwise, anew EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New HomeCity/FL Zip: FT. PIERCE. FL
4/21/202010:32:17 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1