Loading...
HomeMy WebLinkAboutEnergy Code''FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: -b-TA �, �}Q CS� Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location:. FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9.. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.60 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1476.0 sqft. ) insulation • Area a. Under Attic (Vented) R=30.0 1446.00'ft2 6. Conditioned floor area above grade (ft2) 1446 'b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A 12= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a.'Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor:Sol, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/h.r Efficiency SHGC: SHGC=0.27 a. Central Unit 34A SEER:15.00 c. U-Factor; N/A ft2 SHGC: .13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft: Area Weighted Average SHGC:. 0.284 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 50 galloons a. Slab -On -Grade Edge Insulation k=0.0 1445:50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 47.47 Glass/Floor Area: 0.098 c PASS ASS Total Baseline Loads: 48.09 I hereby certify that the plans•and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. ' calculation indicates complianceirf' '�► with the Florida Energy Code. PREPARED BY; - Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 - t I.herebycertify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code.. OWNER/AGENT: BUILDING OFFICIAL: DATE: " DATE: - compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies -as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an. Air Barrier. and Insulation Inspection Checklist in accordance with R40.2.4.1.1 and -this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/21/202010:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORMR405=2017 .INPl1T.S11MMAI*Y nwp:rK1'I-QT RFPnRT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User . Conditioned Area: 1446 Lot # - Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst.Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County:. St. Lucie . Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family. FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter /Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES, Number Name Area Volume Kitchen Occupants Bedrooms. InfilID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes' 3 M:BATH 56 448 No 0 1 Yes Yes Yes- 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY. 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space. Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 ___ . 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ____ 0 1 0 5 Slab-OrnGrade Edge Insulatio BATH 5 ft 0 45 ft2 ____ 0 1 0. 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 __ .0 1 .0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ____ 0 1 0 4/21/202010:27 AM EnergyGauge®.USA 6.0.02 (Rev. 1) - FlaRes2017. FBC 6th Edition (2017) Compliant Software . Page 2 of 5 FORM R465-2017 INPUT SUMMARY'CHECKLIST RFPART FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile ' Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ____ 0 1 , 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 .0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood' 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee.Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width a ()rnt To Wall Type SpaceEt Height n Ft n- Area Sheathing Framing Solar Below o 1 NE=>SW Exterior Concrete Block - Int InsuBEDR00M 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0. 0 0.4 0 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 . 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Int InsBIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 _ 7 SE=>NW Exterior Concrete Block - Int InsBEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InsBIEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Int InsMEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY' 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 _ 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2.. 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Int Insi0.REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InsiG6REAT/DINI 4.1 20 0 8 0 166.0 ft2 0 0 0.4 0 4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes201T FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY I('_141=CKI IST IRIFPnPT WALLS Adjacent it C)rnf To Wall Type Cavity Width Height Space Sheathing Framing Solar Below _ 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ftz' 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 SE=>NW , Insulated ENTRY None .39 3 1 6 8 20.6 ft? WINDOWS Orientation shown.is the entered orientation. => chan ed to Worst Case.. / Wall # Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp ` Area Depth Separation Int'Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE.4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 'NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes 1.04 0.29 Y 32.9 ft' 1 ft 0 in Yes 1.04 0.29 Y 6.9 ftz 1 ft 0 in Yes 1.04 0.29 Y 24.0 ftz 6 ft 0 in Yes 1.04 0.29 Y 37.5 ft' 1 ft 0 in Yes 1.1'1 0.27 Y 40.0 ftZ 8 ft 0 in 1 ft 5 in Drapes/blinds 1 ft 5 in None 1 ft 5 in None 1 ft 5 in. None .1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1349.6 74.09' 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM #. System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric: None Garage 0.97 50 gal 60.9 gal 120 deg None 4/21/2020 10:27 AM EnerggGauge® USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPIIT Sl lMMAI2V r-14F:(%ICII_cr Q=onQT SOLAR -HOT WATER SYSTEM FSEC Collector Storage Pert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / -- Supply ---- --- Return -- Air CFM 25 CFM25• HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic . 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES. Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Heating Jan Feb Venting Mar Mar Apr Apr. May. May Jun r Jul Jun" I Jul Au AuL Se [ �Oct r ,Nov. Sep [ ] Oct [X] Nov Dec f X� Dec Jan . Feb Mar Apr L [ May Jun [[[ Jul Aug [ Se Oct [ Nov [ ] Dec Thermostat'Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling-(WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 80 .80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 .78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 88 68 68 PM 68 68 68 68 68 68 68 68 68, 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 .68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft.. ft2 ft. 0.3 WIC Default(8 Ibs/sq.ft. ft? ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8lbs/sq.ft. ft2 ft 0.3 ' LAUDRY Default(8 Ibs/sq.ft. ft2, ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2, ft 0.3 DINING/GREAT R Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft., ft2 ft 0.3 FOYER Default 8 lbs/s .ft. ft2 ft 0:3 BEDROOM-1' 4/21/202010:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017.- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER -AND INSULATION: INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE ; FL, Permit Number: ,c Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION• INSTALLATION CRITERIA General A• continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit g /soffit the insulation and any gaps in.the air, barrier. shall be sealed. shall be alignedy air with the, ar barrier. Access. openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed Walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and,framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be In contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom. to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall rbe sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa S. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,' or insulation that on installation readily conforms to available space shall extend behind piping and worong- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope -shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids . a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400: 4/21/202010:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software ' . Page 1 of 1 ' 2tl9 7 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Peliformance Index, the. more -efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if -multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system. SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single.package , SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6.. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF . 8.5. b) Single'package Beat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f)-Other 9. Floor type, insulation level: a) Slab-on-grade'(R-value) 9a. 0.0 b) Wood,. raised (R-value) 9b. 1.5. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry -(Insulation R-value) 10A2. 4.1 f) Heat recovery unit- HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. - 11.0 2. Masony (Insulation R-value) 16132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type. and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation, No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving.features which will be installed (or exceeded):in this home before final inspection. Otherwise, anew EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New HomeCity/FL Zip: FT. PIERCE. FL 4/21/202010:32:17 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1