Loading...
HomeMy WebLinkAboutConstruction Plans' SETUP AND INSTALLATION OF SINGLE WIDE SHED SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE- PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLEf THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 A CHORI G TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 S-6" 13'-8" 280 3'-6" 240 3-0" 10'-.0" 200 3-0" B'-0" 160 3 6" 6'-0" 120 3-0" TABLE 2 SKID RUNNER SPACING* SHED WIDTH X1 X2 X3 13'-8" 1-10}" 1'-10}" 1'-1q" 11'-8" 2'-8" 6'-4" - 10'-0" V-7" 6'-10" - 8'-0" 0'-9" 6'-6" - 6'-0" 0'-10" 51" - *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" SKIDS ONLY. 13'-8' WIDE SHEDS HAVE (4) SETS OF SKIDS. RECEIVED NOV 12 7020 mitting Department St. Lucie County 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)4"x44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A PAD TYPES TYPE PAD DIMENSIONSrMAX. LOAD* MATERIAL I 2"x8"x16" 78LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX 4"x8"x16" 00LBS CO CREPE BLOCK QUALITY CEMENT AND SAND MIX 16"x16" 50LBS ABS PLASTIC PADS IV 8"x8"x16" 1900LBS CO CREPE BLOCK QUALITY CEMENT AND SAND MIX • BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-e" AND 13'-e" WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW*(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW 4.15/332 0" TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV 11'-8" SW/DW 6.00/480 0" TO 6" 6'-0" 25581-9 I, II, III, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 0" TO 6" 6'-0" 2400LB I, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 0" TO 6" 6'-0" 2029LB I, II, III, OR IV I 2133LB I, II, III, OR IV 6'-0" SW 3.00/240 0" TO 6" 6'-0" 16581-8 I, H. III, OR IV 1866LEI I, II, III, OR IV • LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD, 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING*** 13'-8" 7.00 243 0'-0" TO S-Or 10'-0" 11'-8" 6.00 208 0'-0" TO 3'-0" 10'-0" k_5 ! 174 U,-0`TOV 3 11 OjyhOi-- .- i - -1 8'-0" 4.00 138 0'-0" TO 3'-0" 10'-0" 6'-0" 3.00 104 V-0" TO 3'-0" 10'-0" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW° UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** 20'-0" 1 10.00 1 400 1 0'-0" TO 3'-0" 1 5"-0" • LOAD WIDTH OF UPLIFT ON RUNNER ::•LOCATION FROM END WALL OF AUGER ANCHOR MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER, ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. _ r '�' �'�- •----N�..sF_° Rs a7f 2"x2" GALVANIZED WASHER 2 x2' GALVANIZED WASHER^'r`O�Y,� rimj'�y'�, T}h°', - H� WITH 1/2 NUT y R7�ii'�lts°. -= "'"r .i WITH 1/2" NUT 1/2" THREADED ROD OPTIONAL FOR "HIGH SET" NOTCH OR COUNTERSINK BOLT J1%2" THREADED ROD; .,, -- z;b r� EYES BOLTED TOGETHER WITH 1/2'x2" THRU 2"x4" BOTTOM PLATE OfpTIONAL�IF,ORY"HIG4 Eai'„ '--, -.s. BOLT & NUT WITH (2)2'x2" GALVANIZED 1/2" COUPLER 2'x4' BOTTOM PLATE NAILED el-: _ - 2 COUPLER ra �i _. _ P/2 x12 r FORGEEYEBOLTe WASHERS 2.000LB SHEAR CAPACITY) ( _ MIN. 1/2"x5" (400 LB.) CONCRETE WEDGE ANCHOR INTO SLAB TO 2'x6P.T. BASE " MIN. rr'a o . 4 � " _� � .� �' -. • � n" < � < � THRU 2"x4' P.T. BOTTOM PLATE SEE G ( TABLE 1 FOR SPACING) 1°---'---�- EYES (BOLTED�jyT4gHERJJWiTH�1`/2 x2 BOLT &° NUT iWITH (2)2rx2 GALVANIZED TYPE' 1°�I' 1'� I tOR NV:PAD,'.(�1IITH BLOCKING AS REQUIRE64(SEE TABLE 3). WASHERS (2000L'B"SHEAR CAPACITY) = �:_, r3-1�,,,- a.._ , 1/2"x3" (400 LB.) CONCRETE WEDGE ANCHOR (SEE TABLE 1 FOR SPACING) SIMPSON CUP A-24 CONCRETE SLAB BY OTHERS THROUGH OR EQUAL LOCAL CODES AND JURISDICTION CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES AND JURISDICTION 30-, II�RTH�,y;Ar„UGER LANCHOR- (SEE�TABLE Z FOR SPACING) k ">�" ' SHED W1TH�.SKID+o1_ i SHED WITH SKID SHED , WITH NO FLOOR' OPTION -+L.Q�'�-- "T- PAD OR BLOCKIN ANCHORED TO CONCRETE ANCHORED TO CONCRETE TIE -DOWN DETAILS CODE VERSION FBC 2017 eth Edmon, ASCE-7 MANUFACTURER SUPERIOR SHEDS BUILDING TYPE IUF cR11RED 000011G RESN U STORAGE CONSTRUCTION TYPE V-e FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES I BASIC WIND SPEED V-1somph EXPOSURE C ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 2OPSF OR 3001be FLOOR DEAD LOAD 8PSF FLOOR LIVE LOAD STD. 75PSF - 125PSF OPT. 'R' RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LF55 THAN 720 SQFT. REVISIONS REV DESCRIPTON I DATE BY 1 2017 FBC 11/12/171 MTB �i 2 GROUND ANCHOR V AF.G MAX. ANCHOR EXRFNS N 5/26/18 WM (f) _,_ MTB Q Date: LJJ 4/26/16 = Scale: N/A odel Li ALL GENERAL NOTES 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. w 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION J 1016.22. m 3. REFER TO TIE -DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. O 0 0 2/5/20 J Matthew T. BQIdWin :E Q otida Lic---ej6461)8 z Sheet: AD- 1 OF 1 F - 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN #SS-B-180-C Side Wall Header Schedule 1180C) End Wall Header Schedule (180C) ,� Size S Fasteners w/o stra - �• -f pan NJ(b} Building Width p (d} Max. > t (each end)(c) - D4 ALUMINUM ROOF SHEATHING Size Up to 14' Wide Fasteners w/ strap 1-2"x4" 6'-0• 0 4-3' x 0.131' nails •_O•( Max. Span NJ{b} (each end) 2_2-1c4°(c) 9'-0' 0(d} 6-3• x 0.131• nails---�`------�"-`"-'� 14"x4" 5-0" 1 0 3 - 3• x 0 131 • nails a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber. rn ro M 1 0 1x4 RUNNERS 0 on END W TRUSS 2"x4' TRUSS ® 24" O.C. MAX. 4•x4• v2°xW &-O" 1 6 - 3' x 0.131" nails b. NJ - Number ofjack studs required to support each end. c. Laid flat 7 a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber. - d. No Jack studs, but a(6 studs laid flat. 1 b. NJ -Number ofjack studs required to support each end. 1 c. Window header for window openings that haw more than 50% combined stud wall above l and below, otherwise use door header schedule. 1. SEE FASTENER SpODUIE FOR ARE IItdJE1T5, d. See header details for alternate layouts, i.e. 2-2"x4" or 4"x4" P.T. 2. SEE 3. READ(:( sa(enulE COIIFFqqtt� 1yp�� ER FIVE RNED 6oX OR WALL FTWINC ABOVE e. The header can be attached to the top plate and thus have the combined strength BEAW, OTHEI aE REFER TO DOOR xFAOFRs CODE INFORMATION equivalent and use the maximum span stated. CODE VERSION F1420117 B°" 1� �-T• MANUFACTURER SUPERIOR SHEDS SALL TUDS BUILDING TYPE MoE4ru ED BtISTnRADE CONSTRUCTION TYPE V-B SINGLE Y:4' i-EXTERIOR THING HER FlRE PROTECTION NONE SHEAFIRE SUPPRESSION SYSTEM NONE (2) 21,4• WTn( 1/2' PLYWOOD i OR OSe F°1m OR 2'.r OCCUPANCY sroRAGE I 12"•12" OR te•.4" BETWEEN 4•.4' ALLOWABLE NUMBER OF STORIES 1 Toffs Tl MVENT IS RED c AS 12` MAx BASIC WIND SPIED v.-180ngh (AWUFACNRE6 HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & °(POSD(E r (OPTIONAL & DOORS DOOR 6' WIDE OR LESS 4"x4" 2"x4" ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1.15 G.F.I. �T OTESROOF DEAD LOAD IOF5F OUTLET N-OPnONAL ELECTRIC ROOF LIVE LOAD 30PSF OR 3DRb POINT LOAD -ALL WIRING SHALL BE 14 GAGE 3-WIRE MC CABLE tTor"_Z.rueenu:e.nc FLOOR DEAD LOAD fogs N T�rruc uxx.w^u as t L -ENCASE IN ALL METAL BOXES. William E. Neary, III FLOOR LIVE LOAD STD. 75PSF - 126PSF OPr. DESIGN PRESSURES SOURCE tl L SMP-SI, SfYid9, ICC SiB5040 'R' RATING N/A ROOF ROOF FRAMING PLAN WIRING DIAGRAM SD5LGotha, eorida .te Te�:e of WALLS FLOOR Roof MODULES PER BUILDING 1 +27.8 -94.7 (OPTIONAL) Gotha, Florida 34734 HURRICANE PROTECTION USAGE No ILLS/DOORS/WINDOWS +32.6/-29.2 HURRICANE SHELTER USAGE No NITE1( OR ALPINE 2'0• END WALL •p0DT1 WNDOW LOCATIONS VARY SQUARE FOOTAGE 719 SOFT. OR LESS OR EnuA. REVISIONS 2'`( oouul LIRE( a+ ALINE 2' OR Fnua DETAIL REV DESCRIPTON DATE BY i � OPTIONS SHEATHHINNGOOP i DER 12. 11Ax.SEE IAAx u STUD; I of DETAIL 1.4 RNSO ON INSmE i W Z DmWn By. MTB 2.4 D�0 0 E1♦oBL i ; / WAUS g Z 12/12/17 END WALL 0- Seale: I N/A 2.4 STUDS o 2a4 SOLE PLATE L to -1 ode : 2t ac NAx FLOOR FRWNG Z SS-B-180C 2"SOLEPLATE 2:4 sole PLATE a � 1. M PLANS ARE NOT PART OF THIS PLAN SET AND ARE FLOOR FRAYNC Ll LJ_I GDVFRNED Br L1xN. JURISDICTION. STUDS SECURED ro SOLE PLATE (y f -J 2 TNIS BULLING R F1�T FROM 7HE FBC ENERGY CONSERVATION CODE PER sE111 1016.2P. = x = AND FLOOR FRAMING WOH 0.03°• (1'n"'h12' STRAP W/6-10d wets STANDARD WALL DETAIL NotE tWA11 FR"G 1�40ERS ARE CONTINUOUS FROM 3 REFER ro 71E- DETAILS FORPROPER NSuuAnaN RFauG(E4ENTs ro caDE. LJ LJ LJ LJ oR EQUAL WITH DOOR & WINDOW OPTIONS *ROOF H DERE W Mt]1�56 A CONTINUOUS LOAD TO O 4. AS N� RAFTERS, TRUSSES, Err. ARE 2.4 }2 �F, EXCEPT VARIES 6'-0' TO 1S-e' AiaES 6'-0• TO 13'-e" FLOOR' PI.AV U Nor CONnNWUs, SHELT fJ TAL Ps, IDS, OR CUPS BE WED GALVANIZEDSTEEL � NOT LESS U 6. STRUCTURES GYM 400 SQ FT. WILL HAVE AN BO• UINOIUW ELEVATION CROSS-SECTION END ELEVATION 4'.4• PT. ATrAo® WTH - 3/4' P.T. PLYWOOD - 3/4• TAG �0, NOU & W DOOR 6. ,.unETs ro BE UISTAUID ON -SITE 9Y oiRE(s 7t6tU LOCAL TYPICAL ARCH FRAME WITH DOOR H24 OR EWNAI}M. SEE TARE 2 FOR (xuNmY AND SPACING. - 3/4• P.T. T&G '-0' (L'I 7 CODES. BOWS AND BOOTS TO MEET THE IJ(wMUM SPECIn DNS IAA1L v AS PER FLORIDA BUILDING CODE '. & FIAT ILETAL STRAPS CAN RE BENT AROUND STRUCTURAL ZBERS OF, WALL STUDS. TRUSSES, CHORDS, ETC. ro HELP SECURE THESE rj��V2' 0 4A7C (2� Yd' tAm FIAT rr rOI SHED WIDTH 13'-6• 8 --0• TABLE 2 >Q x3 Z 0 (L i1719EFS; PROYIOED 7FUT TI£ ADDED BEND DOES NOL INTEifERE ANY EO$n! C BRAIDS E DS 1! T1ff STRAP. T L � ' \ : � • • • �,C E NSF ••••••'•� /i ,•-l-, Cj• 1'-10j• 17-10]' d'_°• O•-8' - ,1 1 -m- ae FRd1 no a-+oer TO Odom a, co 4W SoN ONLY. lr�r "I sms Iwc (q Mai 0, (i WALES 1 v I �,iiGG•7'.��-� .4 B 2I.DO Q 1 Q = 27.6" LAa FIAT j b i 2.6 P.T. 2,C O.C. TVP. STATE ZZ �� TTYP.P.oW" 3/4 Ta'G PLYYL� I i�••• OF ••'• F 24 SOLE PIAIE 4'.4• P.T. AT "ED Wmt H24 OR EOUNALEW. SEE �i • L 0 R I / •. /-�� FLOOR FHAIING SPACING. FOR QUANTITY AND �i •••••....... ... •••^\V `� LJ LxJ LJ E J j < Ma Matthew T. Baldwin P.E. AIRS B'-D' Tof3'$ AfaFS 6'-0• Tot3-e• __-- x t- _-- ---- __-- __-- __-- -- _-- ---- ---- ---- ---- -- ---- ---- ---- ---- ---- --- END ELEVATION END ELEVATION Z Florida license #64608 Sheet SSB-1 OF 1 WITHOUT DOOR WITH GARAGE DOOR FlDDR JOIST. SEE SCHEDULE FOR SIM (MY ONE(DWAw FLOOR FRAMING PLAN m