Loading...
HomeMy WebLinkAboutDesign Certification for Wind Load ComplianceST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT 2300 VIRGINIA AVENUE FT. PIERCE, FL. 34982-5652 561-462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permit involving the construction of new residence (single or multi -family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. PROJECT NAME 5-A-V11-77,) OFFICE USE ONLY STREET ADDRESS �j US �/ / PR NUMBER Q�P Ie- PERMIT NUMBER OCCP. TYPE CST.TYPE CERTIFICATION STATEMENT: VILE UOPY CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. DESIGN PARAMETERS AND ASSUMPTIONS USED: (please check or complete the approprite box) 1. STANDARD BUILDING CODE 1997 EDITION cl 7 ASCE 7-95 OTHER (SPECIFY) 2. BUILDING DESIGN IS (CHECK ONE) LENCLOSED PARTIALLY ENCLOSED OPEN BUILDING 3. BUILDING HEIGHT: FT 4. WIND SPEED USED IN BUILDING DESIGN: A // D MPH 5. WIND EXPOSURE CLASSIFICATION (REFER TO EXPOSURE TABLES IN BUILDING CODE IDENTIFIED IN LINE 91): GU,457)4 (r 6. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: ZS PSF 7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: S PSF a. IMPORTANCE/USE FACTOR (OBTAIN FROM BUILDING CODE): I , () 9. LOADS: FLOOR PSF ' ROOFIDEAD: a % A PSF ROOF/LIVE: 30 PSF 10. WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (CHECK ONE) YES NO _ If NO, why? (attach explaination) 11. IS A CONTINUOUS LOAD PATH PROVIDED (CHECK ONE) YES NO _ If NO, why? (attach explaination) 12. ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK ONE) YES _ NO_ If NO, why?. (attach._ explaination) 13. MINIMUM SOIL BEARING PRESSURE: PSF AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION INCLUDED WITI- ITHIS CE TIFICATION IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF.' iec ��t- `' : n /J C G ► NAME: i�C n%f� /�i9'�%�r�i/¢ CERTIFICATION NO: 46 3J a�/L is [SEAL HERE] DESIGN FIRM: DATE: �t.LCCDV FORM NO: 62o-m