HomeMy WebLinkAbout5380-Stacked8_v2019.01 - Sheet - CA2 - ARCHITECTURAL CANOPY PLAN, ELEVATIONS, AND DETAILSCA227 1 A B 2 3 4 C D 18 CA2 PRE-ENGINEERED METAL PANEL DECKING COLOR TO MATCH BUILDING METAL ROOF TRENCH DRAIN TO 4" PVC DOWNSPOUTS CONCEALED WITHIN COLUMNS BELOW, GC TO COORDINATE CONNECTION TO STORM DRAINAGE SYSTEM WAWA SIDE STREET SIDE CA1 23 CA1 17 CA227 1 A B 2 3 4 C D 18 CA2 WAWA SIDE SURFACE MOUNTED LIGHT FIXTURE, RE: ELECTRICAL EXPOSED STEEL CANOPY STRUCTURE COLOR: FACTORY PAINTED WHITE EXPOSED METAL DECK, RE: STRUCTURE COLOR: WHITE DOWNSPOUT IN COLUMN (BY CANOPY MFR., TYP. EACH COLUMN @ LOW SIDE OF ROOF) STREET SIDE CA1 17 CA1 23 B.O. TRUSS 14' -0" D PRE-ENGINEERED METAL PANEL DECKING BY CANOPY MFR.2" LAM PANEL BY CANOPY MFR. MATCH DECK MATERIAL FLUSH WITH RAFTER BEAM DRAIN RING W/ GUTTER STRAINER BY CANOPY MFR PVC TRANSITION BY CANOPY MFR. 4" PVC TUBING BY CANOPY MFR. COLUMN WITH INTERIOR PVC DOWNSPOUT BY CANOPY MFR. 20GA EMBOSSED TRIM ATTACH TO LOWER GUTTER TRIM, COLOR TO MATCH TOP OF ROOF PANELS 2 PIECE ALUMINUM GUTTER BY CANOPY MFR. 3" OVERLAP AND SEAL WATER TIGHT 4" DIA. SCH. 40 PIPE WELDED INTO RAFTER BEAM BY CANOPY MFR. 1/4" / 12" B.O. CANOPY 14' -9 3/4" GRADE 0' -0" A B B.O. TRUSS 14' -0" C D BOLLARD (TYP.) SEMI-RECESSED FIRE EXTINGUISHER CABINET MOUNTED AT BRACKET LOCATIONS PROVIDED BY CANOPY MANUFACTURER. TYP. 1 PER MPD. TOP OF CABINET 48" A.F.F. MPD ISLANDMPD ISLAND 12' - 0"18' - 0"12' - 0" EMBOSSED TRIM. COLOR: TO MATCH BUILDING METAL ROOF FACTORY ASSEMBLED STEEL TRUSS COLOR: FACTORY PAINTED WHITE STEEL COLUMN COLOR: FACTORY PAINTED WHITE WAWA SIDE DOWNSPOUT IN COLUMN (BY CANOPY MFR. TYP. EACH COLUMN AT LOW SIDE OF ROOF) BLADE PUMP NUMBER SIGN BY SIGNAGE MFR. BLADE PUMP NUMBER SIGN BY SIGNAGE MFR. BLADE PUMP NUMBER SIGN BY SIGNAGE MFR.5' - 6"RE: CIVILVARIESFIRE EXTINGUISHER SIGN SIGN PANEL BY OWNER ON EACH END ELEVATION (TYP. OF 2) TRASH W/ WINDOW WASH STATION & RECYCLE UNITS. LEVEL RECEPTACLES AND ATTACH W/ (2) 3/8" X 3 3/4" WEDGE ANCHORS SPILL KIT VALET BOLTED AND CAULKED TO CONCRETE BY PETROLUM CONTRACTOR. ALLOW FOR LID REMOVAL. REFER TO CANOPY FLOOR PLAN FOR LOCATIONS T.O. CANOPY 25' -2" B.O. CANOPY 14' -9 3/4" NOTE: SIGNAGE IS SHOWN FOR REFERENCE ONLY SEPARATE PERMIT REQUIRED 12 CA1 SIM.2' - 9"CA2 11 9" AUGER BORE 1' - 6" 1/8" PLASTIC COVER BY IDEAL SHIELD 6" SCH. 80 STEEL PIPE NEOPRENE TAPE 10" SCHEDULE 40 PVC SLEEVE CUT 1" BELOW FINISHED SIDEWALK ELEVATION CONCRETE & SUB BASE VARYING THICKNESS SUBGRADE PEA GRAVEL CONCRETE ENCASEMENT 6" COMPACTED PEA GRAVEL BED ADJACENT SURACE FACE OF SIDEWALK CENTER OF BOLLARD 9" MIN. FROM EDGE OF POUR NOTE: REFER TO CIVIL DRAWING FOR ADDITIONAL BOLLARD INFORMATION COVER EMBEDDED 1/2" INTO SEALANT 1" SIKAFLEX 1C SL SEALANT 3" NON-SHRINK GROUT PEA GRAVEL 6" SCH. 80 STEEL PIPE PVC SLEEVE CUT 1" BELOW FINISHED ELEVATION CONCRETE ENCASEMENT 10" SCH. 40 PVC SLEEVE SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 11:44:28 AMCA2218071904-17-2020S.G.A.D.M.ARCHITECTURAL CANOPY PLAN, ELEVATIONS, AND DETAILSORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA STACKED 8 GAS CANOPY 2019.01 STORE #5380-ORN04/17/2020 1/8" = 1'-0"CA2 16 CANOPY ROOF PLAN 1/8" = 1'-0"CA2 4 CANOPY REFLECTED CEILING PLAN 3/4" = 1'-0"CA2 18 SECTION @ TRENCH DRAIN CA2 30 PERSPECTIVE (FOR REFERENCE ONLY) 1/4" = 1'-0"CA2 27 CANOPY ELEVATION 1/2" = 1'-0"CA2 5 BOLLARD DETAIL 1" = 1'-0"CA2 11 ENLARGED BOLLARD DETAIL Revision ScheduleNo.DescriptionDatePERMIT SET04/17/2020