Loading...
HomeMy WebLinkAboutpontorno architect Ft. Pierce Building Department Ft. Pierce, Florida Re: John Ponturno Residence Hutchinson Island, FL November 19, 2020 To Whom It May Concern, The door and window opening design loads for the above referenced address are as follows: Code Used ASCE 7-10 Design Wind Speed 170 mph (Nominal 131.7mph) Building Category II Hurricane Exposure D Height Above Ground 40' Mean Roof Height 200' Infernal Pressure Enclosed Building Length W% Building Width 60' Roof Slope 0 End Zone 12.0' Window/Door Numbers Zone Ht. Width Length Pressure 1 Kitchen 4 4 26" 38" +53.4 psf -57.9 psf 2 Bath 4 4 25" 26" +53.4 psf -57.9 psf 3 Bedroom Egress 4 4 37" 5W +52.6 psf -57.0 psf 4 Bedroom Egress 4 4 37" 50" +52.6 psf -57.0 psf 5' Hall 4 4 71.5" 33" +51.7 psf -56.2 psf Signed and Sealed, Stephan A. Yecles Florida egistered Architect AR0007444 Stephen A.Yeckes,Architect 772 U.S. Highway One. North Palm Beach. Florida 33408 561•626.0402