HomeMy WebLinkAboutmendiguren acrhitect Hutchinson Island Building Department Re: Pedro Mendiguren Residence Hutchinson Island, FL November 19, 2020 To Whom It May Concern, The door and window opening design loads for the above referenced address are as follows: Code Used ASCE 7-10 Design Wind Speed 170 mph (Nominal 131.7mph) Building Category II Hurricane Exposure D Height Above Ground 40' Mean Roof Height 200' Internal Pressure Enclosed Building Length 400' Building Width 60' Roof Slope 0 End Zone 12.0' Window/Door Numbers Zone Ht. Width Length Pressure 1 Mstr. Bedroom 4 4 141.8" 9V +42.8 psf -55.1 psf 2 Living 4 4 141.8 96" +44.8 psf -55.1 psf 3 Guest 4 4 141.8 96" +44.8 psf -55.1 psf Signed and Sealed, Stephan A. Yeckes FlbrFida.QqUWtered Architect AR0007444 Stephen A.Yeckes,Architect 772 U.S. Highway One, North Palm Beach. Florida 33408 961•626.0402