HomeMy WebLinkAboutBuilding PlanGround Fault Circuit Breaker (For Pump) — Water Proof 11 Ground Fault Circuit Breaker (located 6' - 20' from water) Motor / Light (Separate Circuit) Pump Motor Time Clock Integral with pump Transformer Niche less Single Pole PAL Color TREO light Single Throw (No Junction Box Required) Toggle Switch or Wireless Remote \ Pool Light NOTES: -Ground all metal boxes. -LED Niche -less light requires no ground. -Light fixture does not require GFCI or junction box Electric Diagram Not To Scale Pump Screwed down with 1.5" Long 1/8 or larger approved concrete anchors I Filter Screwed down with 1.5" Long 1/8 or larger approved concrete anchors Pump & Filter Tie Top view / Not To Scale 0 Surface Water Level '18" min-24" max from inside wall of pool �I Bonded Ground Wire #8 Solid bare at 4 Points of Pool. cooper bond 1 at water bond fitting, wire w/ approved and at each electrical component Clamps =One an each at equipment pad. side of the pool (1) #8 Bare copper wire TOTAL: 4 bonded to pool steel Equipotential Bonding Detail Per Florida Building Code Adaptation of N.E.C.2008 sec680.26 Not To Scale OLEANDER AVENUE 121.611 y`s Driveway Covered N I I N N #415 __ j One Story Residence ® k C) 18' -I O11 dip FCP O PR P' DEC - CONC. r� N 61 PROPOSED 5Ol do POOL 91-11, ��I,1011 O I � V Slte NOTES: 1. PLANS AND ENGINEERING ACCORDANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL 2017, ANSI/NSPI 3, ANSI/NSPI 4, ANSIMSPA 5, ANSI/NSPI 6, and ANSI/APSP 7. 2. ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING CODE RESIDENTIAL 2017, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSIINSPI 6, and ANSI/APSP 7, 3. ALL PIPING SHALL BE SCH 40 OR SCH 80 PVC, AND INSTALLATIONS SHALL BE COMPLY WITH FBC PLUMBING 2017, 4. ALL POOL AND SPA SHALL BE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF MINIMUM, 5. ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH #8 GROUND WIRE PER NEC 680, 6. POOL AND SPA SHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLOSURE, HOUSE SAFETY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FBCR 4502,17.1 7. ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2017 (SEPARATE CONTRACTOR). 8. ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE CODE IN EFFECT AT THE CONSTRUCTION SITE. 9. POOL AND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD. 10. AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT LICENSED POOL CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED. 11. HEATING EQUIPMENT SHALL COMPLY WITH FBC R 201T 12. POOL BY VIKING POOLS, James A Marx Jr Florida Professional Engineer Lic # 45024 Concrete Min 2,500 Psi 1211 CV 1-#5 Rebar Cobtinuous 36" Lap Splice Concrete Screen Footer Detail -Floating Footer for Pavers Not to Scale Min Concrete Concrete Min 2,500 Psi s 1-#5 Reber CobHnuous 36" Lap Splice Concrete Screen Footer Detail -Monolithic Slab. Not to Scale LEGEND: SK Skimmer PR Pool Return KK Suction Cleaner Line TO EQUIPMENT PAD ELECTRIC BOND, SAFETY FENCE, REBAR DETAIL SAFETY FENCE 48", 3600 PERIMETER, EQUIPOTENTIAL BOND 3` CENTERS, 2' FROM WATER LINE #8 BARE COPPER GROUND WIRE I - TO ELECTRICAL COMPONENTS AT EQUIPMENT PAD ° , o o DIRECT BURIAL GROUND CLAMPS 4 AT CORNERS #3 J-SHAPED REBAR, 3' LENGTH @ 2' CENTERS, 360° PERIMETER OF POOL Plan Scale: 1 "=10' Specifications: Skimmer Vent Through Lid #8 Bare Copper Pool Model: I-,�blmenslons^ I �s"x I I -fin Water Level Deck Surface to Bond Grid /J Surface Area: Light: 1-- perimeter; h� foal Watts, t-- Pump Discharge Filter) 9 2� ' OI I Pool Returns: Capacity ( gals) ; 4-- � /(To VAC Stubout: Approved VAC Lock Fitting furrr\ler rate ( minutes) ; Interior Finish: FIBERGLASS WITH GEL COAT Pump #1: Pump #2 t-il"l- � o , Filter: filter- Sgua e �Aage; 2" PVC Pipe Pump In. pipe pool Main brain connecting pipe Schedule 40 O Suction A- in, pipe 5pa Main iirain connecting pipe In, pipe 5pa T�lerapy 5uction EQUIPMENT PAD PB2008 Waterbond 1" watertight, underground PVC pipe 5uction Cleaner Line OWNER: Fitting,Installed PoolDeck conduit back to 120V AC112V AC in, e Pool 5kimnler Line Pipe Sideways Horizontally Water Level transformer locatian, no junction box. All fittings should be """"" pipe fool heturn Line C yl/ f�. TERRI LUNSFORD attached toe ui otentlal copper and Wire q P pP h 1 glued and watertight ', J •. C' , n, pipe pa pcturn Line f' , POOL CONTRACTOR: Per 20NEC Section 680.2E (C) U Listed 40YZ \ QP.��GENS ;'S �� n pipe. I�eol filer No 2g94g , * p p spy i'cAurn Line= GEOFFROY (GEOFF) P HILAIRE -; - * : - in. pipe 5pa 11nerapy peturn Line= All America Pools Inc Pump/Skimmer Detail - - :. - ssotE of ° 5506 Melville Rd Not To Seale ; A., `�'o,� • F(ORt�P'U��.,`` Fort Pierce FL 34982 PAUL WELCH INC.T *Minimum of 3 1/2" of straight, 1 1/2" PVC �SS�ONA�F�`°� >> Phone: (772) DIG -POOL (344-7665) MECHANICAL * ELECTRICAL * CIVIL ENGINEERING pipe behind wall fitting required prior to PAUL WELCH P. . FL. REG. No. 29945 Florida Certified Pool Contractor CPC-057355 S`T. 1 1 CIA " CM 6,00© al. a rox. i984S.W. BILTMOREST. SUITE#1 14 LVLr /'1 �.r1Y1 V �,! g pp conduit reducer or bend. Parcel # 3419,510-0209-000-6 PORT SAINT LUCIE, FL 34984 SCALE:1 "=5`-0` No -Niche LED LEGAL DESCRIPTION: 415 NE OLEANDER AVE Light Detail RIVER PARK -UNIT 2- BILK 17 LOT 20(MAP 34122N) PHONE EMAIL (772) 785 - 9888 PWELCHINC@AOL.COM Not To Scale PORT SAINT LUCIE, FL 34952