HomeMy WebLinkAboutEEMAX SPEX3512T BLOOM BEAUTYInformation and product specifications contained in this document are subject to change without notice. REV 2020-01
Specifications
Tankless Electric Water Heater
FlowCo™
Non-Thermostatic Heater Ideal for Handwashing And Other Fixed-Flow Applications
Note: For optimum performance, mounting location should be within 2 feet of fixture.
Applications
•Handwashing
•Kitchen, bar, utility sink
•Point-of-use & fixed-flow fixture
•One (1) lavatory faucet, sensor faucet or metering faucet
Performance Features
• Self-diagnostics with intelligent controls actively protect heater in
installed environment
• InfoCue™ visible LED indicator communicates system status
and heater operation feedback
• SafeStart™ technology engages upon start-up to help avoid
dry-fire occurrence
• Low activation flow starting at 0.25 GPM turn on
(model dependent)
• Mounts in any orientation for a flexible installation
• Compact size fits almost anywhere; suitable for ADA compliant
facilities
•Only one cold water line needed for an easy installation
• No T&P relief valve needed (check local codes); Ready to go,
right out-of-the-box
•Save water and time by installing unit at the point-of-use
• Integral 3/8" compression fittings; no soldering or sweat
connections required
•Control system activates heater only on demand
•High temperature limit switch enables safe operation
•5-year limited warranty on leaks, 1-year on parts
Product Specifications
Dimensions:10.75" H x 5.25" W x 3" D
Product Weight: (model dependent) 2.75 lb/3 lb
Cover:ABS-UL 94 5VA
Color: White
Min. Dynamic Operating Pressure: 30 PSI
Max. Dynamic Operating Pressure: 150 PSI
Element: Replaceable nichrome cartridge insert
Fittings: 3/8" compression fittings
UL listed file number: E86887
U.S. Patent Pending Technology
Special Design Service
Inquiries for units for unique applications are welcome. Call our
Technical Service department at 1-800-543-6163.
Suggested Specification
Tankless water heater shall be an Eemax model number
SPEX________.
Unit shall have ABS-UL 94 5VA rated cover. Unit shall allow
mounting in any orientation. Element shall be replaceable cartridge
insert. Element shall be iron-free, nickel-chrome material. Unit
shall have replaceable filter in the inlet connector. Unit shall include
an integrated flow meter to ensure accurate turn-on / turn-off
flow rate. Heater shall be fitted with 3/8" compression fittings to
eliminate the need for soldering. Maximum operating pressure of
150 PSI. Diagnostic features to include LED error/fault indicator.
Heater shall employ technology that engages upon start-up to
avoid dry-fire occurrence. Hot water storage tanks prohibited. Unit
shall be Eemax or approved equal.
NOTE: Refer to rating chart for product information.
Specification options to be included with SPEX models:
_____ N4 NEMA 4 steel cabinet with powder coat finish
_____ N4X NEMA 4 stainless steel, corrosion-resistant cabinet
Tested and certified by the
Water Quality Association
against NSF/ANSI 372 for
lead free compliance.
Information and product specifications contained in this document are subject to change without notice. REV 2020-01
Specifications
Tankless Electric Water Heater
FlowCo
Non-Thermostatic Heater Ideal for Handwashing And Other Fixed-Flow Applications
TEMPERATURE RISE °F
MODEL NUMBER kW AMPS
RECOMMENDED
WIRE SIZE
(75° C/CU)
TURN ON
(GPM)
0.3
GPM
0.5
GPM
0.75
GPM
1.0
GPM
1.5
GPM
2.0
GPM
VOLTS 120
SPEX1812 1.8 15 14 AWG 0.2 41°25°16°12°8°6°
C SPEX1812CA (Canadian model)1.8 15 14 AWG 0.2 41°25°16°12°8°6°
SPEX2412 2.4 20 14 AWG 0.25 55°33°22°16°11°8°
C SPEX2412CA (Canadian model)2.4 20 14 AWG 0.25 55°33°22°16°11°8°
SPEX3012 3.0 25 12 AWG 0.25 68°41°27°20°14°10°
C SPEX3012CA (Canadian model)3.0 25 12 AWG 0.25 68°41°27°20°14°10°
SPEX3512 3.5 29 10 AWG 0.3 80°48°32°24°16°12°
C SPEX3512CA (Canadian model)3.5 29 10 AWG 0.3 80°48°32°24°16°12°
VOLTS 208 Single Phase
SPEX3208 3.0 15 14 AWG 0.25 68°41°27°20°14°10°
C SPEX3208CA (Canadian model)3.0 15 14 AWG 0.25 68°41°27°20°14°10°
SPEX4208 4.1 20 14 AWG 0.4 –56°37°28°19°14°
C SPEX4208CA (Canadian model)4.1 20 14 AWG 0.4 –56°37°28°19°14°
SPEX8208 8.3 40 8 AWG 0.7 ––76°57°38°28°
C SPEX8208CA (Canadian model)8.3 40 8 AWG 0.7 ––76°57°38°28°
VOLTS 240*
SPEX35 3.5 15 14 AWG 0.3 80°48°32°24°16°12°
SPEX35 (derated 208V performance)2.6 13 14 AWG 0.3 59°36°24°18°12°9°
C SPEX35CA (Canadian model)3.5 15 14 AWG 0.3 80°48°32°24°16°12°
SPEX48 4.8 20 14 AWG 0.4 –66°44°33°22°16°
SPEX48 (derated 208V performance)3.6 17 14 AWG 0.4 –49°33°25°16°12°
C SPEX48CA (Canadian model)4.8 20 14 AWG 0.4 –66°44°33°22°16°
SPEX55 5.5 23 12 AWG 0.5 –75°50°38°25°19°
SPEX55 (derated 208V performance)4.1 20 12 AWG 0.5 –56°37°28°19°14°
C SPEX55CA (Canadian model)5.5 23 12 AWG 0.5 –75°50°38°25°19°
SPEX65 6.5 27 10 AWG 0.7 ––59°44°30°22°
SPEX65 (derated 208V performance)4.8 23 10 AWG 0.7 ––44°33°22°16°
C SPEX65CA (Canadian model)6.5 27 10 AWG 0.7 ––59°44°30°22°
SPEX75 7.5 32 10 AWG 0.7 ––68°51°34°26°
SPEX75 (derated 208V performance)5.6 27 10 AWG 0.7 ––51°38°25°19°
C SPEX75CA (Canadian model)7.5 32 10 AWG 0.7 ––68°51°34°26°
SPEX95 9.5 40 8 AWG 0.8 –––65°43°32°
SPEX95 (derated 208V performance)5.6 34 8 AWG 0.8 –––38°25°19°
C SPEX95CA (Canadian model)9.5 40 8 AWG 0.8 –––65°43°32°
VOLTS 277 Single Phase
SPEX3277 3.0 11 14 AWG 0.25 68°41°27°20°14°10°
C SPEX3277CA (Canadian model)3.0 11 14 AWG 0.25 68°41°27°20°14°10°
SPEX4277 4.1 15 14 AWG 0.4 –56°37°28°19°14°
C SPEX4277CA (Canadian model)4.1 15 14 AWG 0.4 –56°37°28°19°14°
SPEX60 6.0 22 12 AWG 0.7 ––55°41°27°20°
C SPEX60CA (Canadian model)6.0 22 12 AWG 0.7 ––55°41°27°20°
SPEX80 8.0 29 10 AWG 0.7 ––73°55°36°27°
C SPEX80CA (Canadian model)8.0 29 10 AWG 0.7 ––73°55°36°27°
SPEX90 9.0 33 10 AWG 0.7 ––82°61°41°31°
C SPEX90CA (Canadian model)9.0 33 10 AWG 0.7 ––82°61°41°31°
SPEX100 10.0 36 8 AWG 0.8 –––68°46°34°
C SPEX100CA (Canadian model)10.0 36 8 AWG 0.8 –––68°46°34°
* 240V units can be used on 208V single phase with
25% reduced temperature output. Please note per UL
standards the rating plate and installation instructions
will all be according to a 240V applied voltage. Check
with local officials prior to derating the electrical
infrastructure.
"C "indicates evaluation and compliance to either
Underwriters Laboratories (UL) or Intertek (ETL) under
CAN/CSA-C22.2 No. 64/No. 88.
3.00
.81
9.73
1.12 1.50
INLETOUTLET
5.25
11.81
9.84 7.30
11.08
1.07 4.17 1.50
5.91
NEMA 4/4X
INLETOUTLET
4X Ø.25MOUNTING HOLES