Loading...
HomeMy WebLinkAboutEEMAX SPEX3512T BLOOM BEAUTYInformation and product specifications contained in this document are subject to change without notice. REV 2020-01 Specifications Tankless Electric Water Heater FlowCo™ Non-Thermostatic Heater Ideal for Handwashing And Other Fixed-Flow Applications Note: For optimum performance, mounting location should be within 2 feet of fixture. Applications •Handwashing •Kitchen, bar, utility sink •Point-of-use & fixed-flow fixture •One (1) lavatory faucet, sensor faucet or metering faucet Performance Features • Self-diagnostics with intelligent controls actively protect heater in installed environment • InfoCue™ visible LED indicator communicates system status and heater operation feedback • SafeStart™ technology engages upon start-up to help avoid dry-fire occurrence • Low activation flow starting at 0.25 GPM turn on (model dependent) • Mounts in any orientation for a flexible installation • Compact size fits almost anywhere; suitable for ADA compliant facilities •Only one cold water line needed for an easy installation • No T&P relief valve needed (check local codes); Ready to go, right out-of-the-box •Save water and time by installing unit at the point-of-use • Integral 3/8" compression fittings; no soldering or sweat connections required •Control system activates heater only on demand •High temperature limit switch enables safe operation •5-year limited warranty on leaks, 1-year on parts Product Specifications Dimensions:10.75" H x 5.25" W x 3" D Product Weight: (model dependent) 2.75 lb/3 lb Cover:ABS-UL 94 5VA Color: White Min. Dynamic Operating Pressure: 30 PSI Max. Dynamic Operating Pressure: 150 PSI Element: Replaceable nichrome cartridge insert Fittings: 3/8" compression fittings UL listed file number: E86887 U.S. Patent Pending Technology Special Design Service Inquiries for units for unique applications are welcome. Call our Technical Service department at 1-800-543-6163. Suggested Specification Tankless water heater shall be an Eemax model number SPEX________. Unit shall have ABS-UL 94 5VA rated cover. Unit shall allow mounting in any orientation. Element shall be replaceable cartridge insert. Element shall be iron-free, nickel-chrome material. Unit shall have replaceable filter in the inlet connector. Unit shall include an integrated flow meter to ensure accurate turn-on / turn-off flow rate. Heater shall be fitted with 3/8" compression fittings to eliminate the need for soldering. Maximum operating pressure of 150 PSI. Diagnostic features to include LED error/fault indicator. Heater shall employ technology that engages upon start-up to avoid dry-fire occurrence. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal. NOTE: Refer to rating chart for product information. Specification options to be included with SPEX models: _____ N4 NEMA 4 steel cabinet with powder coat finish _____ N4X NEMA 4 stainless steel, corrosion-resistant cabinet Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance. Information and product specifications contained in this document are subject to change without notice. REV 2020-01 Specifications Tankless Electric Water Heater FlowCo Non-Thermostatic Heater Ideal for Handwashing And Other Fixed-Flow Applications TEMPERATURE RISE °F MODEL NUMBER kW AMPS RECOMMENDED WIRE SIZE (75° C/CU) TURN ON (GPM) 0.3 GPM 0.5 GPM 0.75 GPM 1.0 GPM 1.5 GPM 2.0 GPM VOLTS 120 SPEX1812 1.8 15 14 AWG 0.2 41°25°16°12°8°6° C SPEX1812CA (Canadian model)1.8 15 14 AWG 0.2 41°25°16°12°8°6° SPEX2412 2.4 20 14 AWG 0.25 55°33°22°16°11°8° C SPEX2412CA (Canadian model)2.4 20 14 AWG 0.25 55°33°22°16°11°8° SPEX3012 3.0 25 12 AWG 0.25 68°41°27°20°14°10° C SPEX3012CA (Canadian model)3.0 25 12 AWG 0.25 68°41°27°20°14°10° SPEX3512 3.5 29 10 AWG 0.3 80°48°32°24°16°12° C SPEX3512CA (Canadian model)3.5 29 10 AWG 0.3 80°48°32°24°16°12° VOLTS 208 Single Phase SPEX3208 3.0 15 14 AWG 0.25 68°41°27°20°14°10° C SPEX3208CA (Canadian model)3.0 15 14 AWG 0.25 68°41°27°20°14°10° SPEX4208 4.1 20 14 AWG 0.4 –56°37°28°19°14° C SPEX4208CA (Canadian model)4.1 20 14 AWG 0.4 –56°37°28°19°14° SPEX8208 8.3 40 8 AWG 0.7 ––76°57°38°28° C SPEX8208CA (Canadian model)8.3 40 8 AWG 0.7 ––76°57°38°28° VOLTS 240* SPEX35 3.5 15 14 AWG 0.3 80°48°32°24°16°12° SPEX35 (derated 208V performance)2.6 13 14 AWG 0.3 59°36°24°18°12°9° C SPEX35CA (Canadian model)3.5 15 14 AWG 0.3 80°48°32°24°16°12° SPEX48 4.8 20 14 AWG 0.4 –66°44°33°22°16° SPEX48 (derated 208V performance)3.6 17 14 AWG 0.4 –49°33°25°16°12° C SPEX48CA (Canadian model)4.8 20 14 AWG 0.4 –66°44°33°22°16° SPEX55 5.5 23 12 AWG 0.5 –75°50°38°25°19° SPEX55 (derated 208V performance)4.1 20 12 AWG 0.5 –56°37°28°19°14° C SPEX55CA (Canadian model)5.5 23 12 AWG 0.5 –75°50°38°25°19° SPEX65 6.5 27 10 AWG 0.7 ––59°44°30°22° SPEX65 (derated 208V performance)4.8 23 10 AWG 0.7 ––44°33°22°16° C SPEX65CA (Canadian model)6.5 27 10 AWG 0.7 ––59°44°30°22° SPEX75 7.5 32 10 AWG 0.7 ––68°51°34°26° SPEX75 (derated 208V performance)5.6 27 10 AWG 0.7 ––51°38°25°19° C SPEX75CA (Canadian model)7.5 32 10 AWG 0.7 ––68°51°34°26° SPEX95 9.5 40 8 AWG 0.8 –––65°43°32° SPEX95 (derated 208V performance)5.6 34 8 AWG 0.8 –––38°25°19° C SPEX95CA (Canadian model)9.5 40 8 AWG 0.8 –––65°43°32° VOLTS 277 Single Phase SPEX3277 3.0 11 14 AWG 0.25 68°41°27°20°14°10° C SPEX3277CA (Canadian model)3.0 11 14 AWG 0.25 68°41°27°20°14°10° SPEX4277 4.1 15 14 AWG 0.4 –56°37°28°19°14° C SPEX4277CA (Canadian model)4.1 15 14 AWG 0.4 –56°37°28°19°14° SPEX60 6.0 22 12 AWG 0.7 ––55°41°27°20° C SPEX60CA (Canadian model)6.0 22 12 AWG 0.7 ––55°41°27°20° SPEX80 8.0 29 10 AWG 0.7 ––73°55°36°27° C SPEX80CA (Canadian model)8.0 29 10 AWG 0.7 ––73°55°36°27° SPEX90 9.0 33 10 AWG 0.7 ––82°61°41°31° C SPEX90CA (Canadian model)9.0 33 10 AWG 0.7 ––82°61°41°31° SPEX100 10.0 36 8 AWG 0.8 –––68°46°34° C SPEX100CA (Canadian model)10.0 36 8 AWG 0.8 –––68°46°34° * 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure. "C "indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88. 3.00 .81 9.73 1.12 1.50 INLETOUTLET 5.25 11.81 9.84 7.30 11.08 1.07 4.17 1.50 5.91 NEMA 4/4X INLETOUTLET 4X Ø.25MOUNTING HOLES