HomeMy WebLinkAboutEnergy Conservation ChecklistFlorida Building Code,. -Fifth Edition (2014) - Energy Conservation EnergyGauge Summit@ Fla/Com-2015, Effective -Date: June 30, 2015 ASHRAE.90J, -2010 -!,Energy Cost Budget Option Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: ❑ This Checklist ❑ An Input report generated from the software just after completing compliance calculations without any further changes ❑ The full compliance report generated by the software that contains the project summary, complaince summary, certifications and detailed component compliance reports ❑ Boxes appropriately checked in the Miscellanous report generated by the software at the end of the compliance report ,( 4 EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 1 of 16 PROJECT SUMMARY Short Desc: 16019 TCERDA Description: 16019 TCERDA Owner: Sunshine Kitchen Addressl: 2199 South Rock Rd City: Fort Pierce Address2: State: FL Zip: 34945 Type: Dining: Family Class: Renovation to existing Jurisdiction: FORT PIERCE, ST LUCIE COUNTY, FL (661100) Conditioned Area: 4018 SF Conditioned & UnConditioned Area: 4018 SF No of Stories: 1 Area entered from Plans 4000 SF Permit No: 0 Max Tonnage 8.3 If different, write in: Compliance Summa Component Gross Energy Cost (in $) LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM + PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design 2_ Criteria Result 2,534.0 PASSED PASSES PASSES PASSES No Entry Not Checked Not Checked Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design buildings must be submitted along with this Compliance Report EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 2 of 16 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Rc 4E Ss tug Prepared By: Kyle J. Cartier I G Building Official: Date: Date: I certify that this building is in compliance with the Florida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (") that the system design is in compliance with the Florida Energy Efficiency Code Architect: Edlund Dritenbas Binkley Arc Electrical Designer: Samuel R. Alexander Lighting Designer: Samuel R. Alexander Mechanical Designer: Kyle J. Cartier Reg No: AR -AA C000886 Reg No: 55422 Reg No: 55422 Reg No: 53269 Plumbing Designer: Kyle J. Cartier Reg No: 53269 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 3/27/2017 EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 Page 3 of 16 Project: 16019 TCERDA Title: 16019 TCERDA Type: Dining: Family (WEA File: DAYTONABEACH.TMY) Building End Uses " 1) Proposed 2) Baseline Total 141.20 162.60 $2,211 $2,534 ELECTRICITY(MBtulkWhl$) 141.20 162.60 41400 47627 $2,211 $2,534, AREA LIGHTS 25.60 38.00 7488 11132 $400 $592 MISC EQUIPMT 41.30 41.30 12108 12108 $647 $644 PUMPS & MISC 0.50 0.50 158 156 $8 $8 SPACE COOL 45.30 29.00 13284 8483 $709 $451 SPACE HEAT 9.60 8.50 2814 2483 $150 $132 VENT FANS 18.90 45.30 5548 13265 $296 $706 Credits Applied: None I PASSES Passing Criteria = 2534 Design (including any credits) = 2211 Passing requires Proposed Building cost to be at most 100% of Baseline cost. This Proposed Building is at 87.3% EnergyGauge Summit® FlalCom-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 4 of 16 Project: 16019 TCERDA Title: 16019 TCERDA Type: Dining: Family (WEA File: DAYTONABEACH.TMY) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Uncovered Parking Areas -- Yes 0.15 30,000.0 4,500 1,400 Parking lots and Drives Tradable Surfaces: 1400 (W) Allowance for Tradable: 3750 (W) PASSES All External Lighting: 1400 (W) Complicance check includes a excess/Base allowance of 750.00(W) EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 5 of 16 Project: 16019 TCERDA Title: 16019 TCERDA Type: Dining: Family (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance Office 1 17 Office - Enclosed 90 1 1 PASSES Office 2 17 Office - Enclosed 90 1 1 PASSES Office 3 17 Office - Enclosed 90 1 1 PASSES Office 4 17 Office - Enclosed 90 1 1 PASSES Office 5 17 Office - Enclosed 90 1 1 PASSES Office 6 17 Office - Enclosed 90 1 1 PASSES Office 7 17 Office - Enclosed 64 1 1 PASSES Office 8 17 Office - Enclosed 100 1 1 PASSES Office 9 17 Office - Enclosed 100 1 1 PASSES W RR 6 Toilet and Washroom 60 1 1 PASSES M RR 6 Toilet and Washroom 60 1 1 PASSES CORRIDOR 5 Corridor 100 1 1 PASSES CORRIDOR 5 Corridor 100 1 1 PASSES LOBBY 12 Lobby (General) - Reception and 400 1 1 PASSES Waiting KITCHEN 7 Food Service - Kitchen 400 2 1 PASSES OFFICE 10 17 Office - Enclosed 64 1 1 PASSES CAGED DRY ST( 3 Storage & Warehouse - Bulky 200 1 1 PASSES Active Storage CORRIDOR 5 Corridor 50 1 1 PASSES KITCHEN 7 Food Service - Kitchen 400 2 1 PASSES JANITOR 1 Electrical Mechanical Equipment 64 1 1 PASSES Room - General VESTIBULE 5 Corridor 176 2 1 PASSES PrOZo3Sp4 1 Electrical Mechanical Equipment 100 1 1 PASSES Room - General KITCHEN 7 Food Service - Kitchen 400 2 1 PASSES KITCHEN 7 Food Service - Kitchen 400 2 1 PASSES DRY STORAGE 3 Storage & Warehouse - Bulky 240 1 1 PASSES Active Storage PASSES EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 6 of 16 Project: 16019 TCERDA Title: 16019 TCERDA Type: Dining: Family MEA File: DAYTONABEACH.TMY) System Report Compliance AHU-2 System 3 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 57700 13.00 13.00 13.00 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 36860 1.00 1.00 PASSES. Air Handling Air Handler (Supply) - 2000 0.37 0.82 PASSES System -Supply Constant Volume Air Distribution Not in Check list - 6.00 6.00 N/A System (Sup) Compliance Ignored Air Distribution Not in Check list - 6.00 6.00 N/A System (Ret) Compliance Ignored Ji TMAU-1 System 4 Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 100000 12.40 11.20 13.00 11.40 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Electric Furnace 69666 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1800 0.82 0.82 PASSES System -Supply Constant Volume Air Distribution Not in Check list - 6.00 6.00 N/A System (Sup) Compliance Ignored TMAU-2 System 4 Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled f 00000 12.40 11.20 13.00 11.40 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Electric Furnace 69666 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1800 0.82 0.82 PASSES System -Supply Constant Volume Air Distribution Not in Check list - 6.00 6.00 N/A System (Sup) Compliance Ignored EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 7 of 16 AHU-1 System 8 Variable Air Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 80000 12.50 11.20 13.00 11.40 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Electric Furnace 61400 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 2750 0.83 1.12 PASSES System -Supply Variable Volume Air Distribution Not in Check list - 6.00 6.00 N/A System (Sup) Compliance Ignored Air Distribution Not in Check list - 6.00 6.00 N/A System (Ret) Compliance Ignored Energy Recovery Compliance Not Applicable PASSES Unit AHU-3 System 8 Variable Air Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 76000 12.50 11.20 13.00 11.40 PASSES 65000 to 135000 Btu/h Cooling Capacity Heating System Electric Furnace 61400 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 2475 0.90 1.12 PASSES System -Supply Variable Volume Air Distribution Not in Check list - 6.00 6.00 N/A System (Sup) Compliance Ignored Air Distribution Not in Check list - 6.00 6.00 N/A System (Ret) Compliance Ignored AHU-4 System 13 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 12650 21.50 13.00 16.00 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 17000 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 375 0.23 0.82 PASSES System -Supply Constant Volume EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 8 of 16 PASSES Plant Compliance Description, Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 16019 TCERDA Title: 16019 TCERDA Type: Dining: Family (WEA File: DAYTONABEACH.TMY) Water Heater Compliance Description Type Category Design Min Eff Eff Design Max Comp Loss Loss liance Water Heater 1 Gas Instantaneous Unknown 0.95 Not Checked water heater Not Checked Project: 16019 TCERDA Title: 16019 TCERDA Type: Dining: Family (WEA File: DAYTONABEACH.TMY) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] Cooling Systems (Chilled Water, Brine 0.25 True 35.00 0.28 0.50 0.50 PASSES and Refrigerant) Domestic and Service Hot Water 1.25 False 140.00 0.28 1.00 1.50 Not Checker Systems Not Checked EnergyGauge Summit@) Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 9 of 16 Mandatory Requirements (as applicable) Mandatory requirements compiled by US Department of iEnergy and Pacific Northwest National Laboratory. Adopted with permission Topic Section Component Description Yes NIA Ex 1. To be checked by Designer, or'Engineer T Fenestration 5.8.2.3,5.5.3.E Envelope U-factor of opaque doors associated with the Br building thermal envelope meets requirements. Insulation 6.4.4.1.5 Envelope Bottom surface of floor structures incorporating ar radiant heating insulated to >=R-3.5. Insulation 5.5.3.1.1 Envelope High-albedo roofs satisfy one of the following: Solar reflectance >= 0.55 and thermal emittance — 0.75, Solar reflectance index >= 64.0, or increased insulation (assembly <= U-0.03 or >_ Rinsulation).g Wattage 9.4.3 Exterior Lighting Exterior lighting grounds lighting over 100 W provides >60 ❑ ❑ Im/W unless on motion sensor or fixture is exempt from scope of code or from external LPD. Wattage 9.4.2 Interior Lighting Exit signs do not exceed 5 watts per face. ❑ ❑ Controls 10.4.3 Mechanical Elevators are designed with the proper lighting, ventilation power, and standby mode. HVAC 6.5.6.1 Mechanical Exhaust air energy recovery on systems meeting Table 6.5.6.1. SYSTEM —SPECIFIC 6.5.1.4 Mechanical Economizer operation will not increase heating energy use during normal operation. SYSTEM —SPECIFIC 6.5.2.2.1 Mechanical Three -pipe hydronic systems using a common return for hot and chilled water are not used. SYSTEM —SPECIFIC 6.5.2.2.3 Mechanical Hydronic heat pump systems connected to a common water loop meet heat rejection and heat addition requirements. SYSTEM —SPECIFIC 6.5.2.4 Mechanical Water economizer specified on hydronic cooling ❑ ❑ and humidification systems designed to maintain inside humidity at >35 OF dewpoint if an economizer is required. SYSTEM —SPECIFIC 6.5.3.1.1 Mechanical HVAC fan systems at design conditions do not ❑ ❑ exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM —SPECIFIC 6.5.3.1.2 Mechanical HVAC fan motors not larger than allowable limits. ❑ ❑ SYSTEM —SPECIFIC 7.4.2 Mechanical Service water heating equipment meets efficiency requirements. SYSTEM —SPECIFIC 7.5.2 Mechanical Service water heating equipment used for space 13 e heating complies with the service water heating equipment requirements. ^A� I To be checked by Plan Reviewer Air Leakage 5.4.3.4 Envelope Vestibules are installed where building entrances separate conditioned space from the exterior, and meet exterior envelope requirements. Doors have self -closing devices, and are >=7 ft apart. Insulation 5.8.1.7.3 Envelope Insulation in contact with the ground has <=0.3% 13 ❑ water absorption rate per ASTM C272. Plan Review 4.2.2,5.4.3.1.1,5.7 Envelope Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 10 of 16 Plan Review 9.7 Exterior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Wattage 9.4.3 Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Plan Review 4.2.2,9.4.4,9.7 Interior Lighting Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. HVAC 6.4.3.4.4 Mechanical Ventilation fans >0.75 hp have automatic controls to shut off fan when not required. HVAC 6.4.3.9 Mechanical Demand control ventilation provided for spaces >500 ft2 and >40 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. HVAC 6.4.4.1.4 Mechanical Thermally ineffective panel surfaces of sensible ❑ 0 heating panels have insulation — R-3.5. HVAC 6.5.2.3 Mechanical Dehumidification controls provided to prevent reheating, recooling, mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. HVAC 6.5.4.1 Mechanical HVAC pumping systems >10 hp designed for variable fluid flow. HVAC 6.5.7.1.1 Mechanical Kitchen hoods >5,000 cfm have make up air > 50% of exhaust air volume. HVAC 6.5.7.2 Mechanical Fume hoods exhaust systems > 15,000 cfm have VAV hood exhaust and supply systems, direct make-up air or heat recovery. HVAC 6.5.8.1 Mechanical Unenclosed spaces that are heated use only radiant heat. HVAC 6.4.3.3.2 Mechanical Setback controls allow automatic restart and temporary operation as required for maintenance. Other Equipment 10.4.1 Mechanical Electric motors meet requirements where applicable. Plan Review 4.2.2,6.4.4.2.1,6.7.2 Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Plan Review 4.2.2,7.7.1,10.4.2 Mechanical Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Plan Review 6.7.2.4 Mechanical Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects > 50,000 U. SYSTEM —SPECIFIC 6.4.3.10 Mechanical Single zone HVAC systems with fan motors > 5 hp have variable airflow controls. Air conditioning equipment with a cooling capacity > 110,000 Btu/h has variable airflow controls. EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 11 of 16 SYSTEM —SPECIFIC 6.5.1,6.5.1.1,6.5.1.3 Mechanical Air economizers provided where required, meet ❑ the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. SYSTEM —SPECIFIC 6.5.1,6.5.1.2,6.5.1.3 Mechanical Water economizers provided where required, 0011 meet the requirements for design capacity, maximum pressure drop and integrated economizer control. SYSTEM —SPECIFIC 6.5.3.2.1 Mechanical VAV fan motors > 10 hp to be driven by variable speed drive, have'a vane -axial fan with variable pitch blades, or have controls to limit fan motor demand. SYSTEM —SPECIFIC 6.5.3.2.3 Mechanical Reset static pressure setpoint for DDC controlled VAV boxes reporting to central controller based on the zones requiring the most pressure. SYSTEM —SPECIFIC 6.5.3.3 Mechanical Multiple zone VAV systems with DDC of individual ❑ 11 zone boxes have static pressure setpoint reset controls. SYSTEM —SPECIFIC 6.5.3.4 Mechanical Multiple zone HVAC systems have supply air ❑ temperature reset controls. SYSTEM —SPECIFIC 6.5.4.2 Mechanical Reduce flow in pumping systems >10 hp. to multiple chillers or boilers when others are shut down. SYSTEM —SPECIFIC 6.5.4.3 Mechanical Temperature reset by representative building loads in pumping systems >10 hp for chiller and boiler systems >300,000 Btu/h. SYSTEM —SPECIFIC 6.5.4.4.1 Mechanical Two -position automatic valve interlocked to shut 11 off water flow when hydronic heat pump with pumping system >10 hp is off. SYSTEM —SPECIFIC 6.5.4.4.2 Mechanical Hydronic heat pumps and water-cooled unitary air ❑ ❑ ❑ conditioners with pump systems >5 hp have controls or devices to reduce pump motor demand. SYSTEM —SPECIFIC 6.5.5.2 Mechanical Fan systems with motors —7.5 hp associated ❑ 0 ❑ with heat rejection equipment to have capability to operate at 2/3 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM —SPECIFIC 6.5.6.2 Mechanical Condenser heat recovery system that can heat ❑ ❑ water to 85 OF or provide 60% of peak heat rejection is installed for preheating of service hot water in 24/7 facility, water cooled systems reject >6 MMBtu, SHW load > 1 MMBtu. SYSTEM —SPECIFIC 6.5.7.1.2 Mechanical Conditioned supply air to space with a kitchen ❑ 0 ❑ hood shall not exceed the greater of a) supply flow required to meet space heating or cooling, or b) hood exhaust flow minus the available air transfer from available spaces. SYSTEM —SPECIFIC 6.5.7.1.3 Mechanical Kitchen hoods with a total exhaust airflow rate >5000 cfm meet, replacement air, ventilation system, or energy recovery requirements shown in Table 6.5.7.1.3. SYSTEM —SPECIFIC 6.5.7.1.4 Mechanical Kitchen hoods with a total exhaust airflow rate >5000 cfm meet, replacement air, ventilation system, or energy recovery requirements. SYSTEM —SPECIFIC 6.5.9 Mechanical Hot gas bypass limited to: ❑ El 11 < 240 kBtu/h — 50% >240 kBtu/h — 25% SYSTEM 7.5.1 Mechanical Combined space and water heating system not —SPECIFIC allowed unless standby loss less than calculated maximum. AHJ has approved or combined connected load <150 kBtu/h. SYSTEM —SPECIFIC 6.4.3.1.1 Mechanical Heating and cooling to each zone is controlled by ❑ ❑ a thermostat control. SYSTEM —SPECIFIC 6.4.3.3.3 Mechanical Systems with air capacity >10,000 cfm include optimum start controls. SYSTEM —SPECIFIC 6.4.3.5 Mechanical Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 12 of 16 J SYSTEM —SPECIFIC 7.4.4.3 Mechanical Public lavatory faucet water temperature < 110°F. ❑ 0 ❑ Controls 8.4.2 Project At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Plan Review 4.2.2,8.4.1.1,8.4.1.2 Project Plans, specifications, and/or calculations provide 0 ❑ ❑ all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Air Leakage 5.4.3.1 Envelope Continuous air barrier is wrapped, sealed, caulked, gasketed, and/or taped in an approved manner, except in semiheated spaces and in climate zones 1-6. Air Leakage 5.4.3.2 Envelope Factory -built fenestration and doors are labeled as ❑ ❑ ❑ meeting air leakage requirements. Air Leakage 5.4.3.1 Envelope All sources of air leakage in the building thermal ❑ ❑ ❑ envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor -permeable wrapping material to minimize air leakage. Fenestration 5.8.2.1 Envelope Fenestration products rated in accordance with ❑ ❑ El NFRC. Fenestration 5.8.2.2 Envelope Fenestration products are certified as to performance labels or certificates provided. Insulation 5.8.1.2 Envelope Below -grade wall insulation installed per 11❑ ❑ manufacturer's instructions. Insulation 5.8.1.2 Envelope Slab edge insulation installed per manufacturers instructions. Insulation 5.5.3.1 Envelope Roof R-value. For some ceiling systems, ❑ 0 Verification may need to occur during Framing Inspection. Insulation 5.8.1.2,5.8.1.3 Envelope Roof insulation installed per manufacturer's instructions. Blown or poured loose -fill insulation is installed only where the roof slope is < 3 in 12. Insulation &5.3.1 Envelope Skylight curbs are insulated to the level of roofs ❑ ❑ ❑ with insulation above deck or R-5. Insulation 5.8.1.2 Envelope Above -grade wall insulation installed per ❑ ❑ ❑ manufacturer's instructions. Insulation 5.8.1.2 Envelope Floor insulation installed per manufacturer's instructions. Insulation 5.8.1.1 Envelope Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Insulation 5.8.1:4 Envelope Eaves are baffled to deflect air to above the ❑ ❑ ❑ insulation. Insulation 5.8.1.5 Envelope Insulation is installed in substantial contact with ❑ 13 ❑ the inside surface separating conditioned space from unconditional space. Insulation 5.8.1.6 Envelope Recessed equipment installed in building ❑ ❑ ❑ envelope assemblies does not compress the adjacent insulation. Insulation 5.8.1.7 Envelope Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Insulation 5.8.1.7.1 Envelope Attics and mechanical rooms have insulation protected where adjacent to attic or equipment access. Insulation 5.8.1.7.2 Envelope Foundation vents do not interfere with insulation. ❑ 0 ❑ EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 13 of 16 Insulation 5.8.1.8 Envelope Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Controls 9.4.1.7 Exterior Lighting Automatic lighting controls for exterior lighting installed. Controls 9.4.1.1 Interior Lighting Automatic controls to shut off all building lighting installed in buildings >5,000 U. Controls 9.4.1.2 Interior Lighting Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Controls 9.4.1.3 Interior Lighting Parking garage lighting is equipped with required lighting controls and daylight transition zone lighting. Controls 9.4.1.4 Interior Lighting Primary sidelighted areas —250 ft2 are equipped with required lighting controls. Controls 9.4.1.5 Interior Lighting Enclosed spaces with daylight area under skylights and rooftop monitors >900 ft2 are equipped with required lighting controls. Controls 9.4.1.6 Interior Lighting Separate lighting control devices for specific uses installed per approved lighting plans. Wattage 9.6.2 Interior Lighting Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Wattage 9.6.3 Interior Lighting Where space LPD requirements are adjusted based on room cavity ratios, dimensions are consistent with approved plans. Wattage 9.2.2.3 Interior Lighting Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed wafts. HVAC 6.4.3.8 Mechanical Freeze protection and snow/ice melting system sensors for future connection to controls. HVAC 6.4.1.4,6.4.1.5 Mechanical HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. HVAC 6.4.3.4.1 Mechanical Stair and elevator shaft vents have motorized dampers that automatically close. HVAC 6.4.3.4.2,6.4.3.4.3 Mechanical Outdoor air and exhaust systems have motorized 0 dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. HVAC 6.4.3.4.5 Mechanical Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. HVAC 6.4.4.1.1 Mechanical Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. HVAC 6.4.4.1.2 Mechanical HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC 6.4.4.1.3 Mechanical HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC 6.4.4.2.1 Mechanical Ducts and plenums sealed based on,static pressure and location. HVAC 6.5.7.1.5 Mechanical Approved field test used to evaluate design air flow rates and demonstrate proper capture and containment of kitchen exhaust systems. HVAC 6.4.3.1.2 Mechanical Thermostatic controls have a 5 °F deadband. HVAC 6.4.3.2 Mechanical Temperature controls have setpoint overlap restrictions. HVAC 6.4.3.3.1 Mechanical HVAC systems equipped with at least one automatic shutdown control. EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 14 of 16 HVAC 6.4.3.7 Mechanical When humidification and dehumidification are provided to a zone, simultaneous operation is prohibited. SYSTEM —SPECIFIC 7.4.4.1 Mechanical Temperature controls installed on service water 11110 heating systems (< 120°F to maximum temperature for intended use). SYSTEM —SPECIFIC 7.4.4.2 Mechanical Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. SYSTEM —SPECIFIC 7.4.6 Mechanical Heat traps installed on non -circulating storage 11011 water tanks. SYSTEM —SPECIFIC 6.4.1.5.2 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. labeled for replacement only. SYSTEM —SPECIFIC 6.4.4.2.2 Mechanical Ductwork operating >3 in. water column requires ❑ air leakage testing. SYSTEM —SPECIFIC 6.5.2.1 Mechanical Zone controls can limit simultaneous heating and cooling and sequence heating and cooling to each zone. SYSTEM —SPECIFIC 6.5.2.2.2 Mechanical Two -pipe hydronic systems using a common distribution system have controls to allow a deadband > 15 OF, allow operation in one mode for at least 4 hrs before changeover, and have rest controls to limit heating and cooling supply temperature to ­30 OF. SYSTEM —SPECIFIC 6.5.3.2.2 Mechanical VAV fans have static pressure sensors positioned so setpoint —1/3 total design pressure. SYSTEM —SPECIFIC 7.4.4.4 Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. SYSTEM —SPECIFIC 7.4.5.1 Mechanical Pool heaters are equipped with on/off switch and no continuously burning pilot light. SYSTEM —SPECIFIC 7.4.5.2 Mechanical Pool covers are provided for heated pools and pools heated to >90°F have a cover > R-12. SYSTEM —SPECIFIC 7.4.5.3 Mechanical Time switches are installed on all pool heaters and pumps. SYSTEM —SPECIFIC 7.4.3 Mechanical All piping in circulating system insulated SYSTEM —SPECIFIC 7.4.3 Mechanical First 8 ft of outlet piping is insulated SYSTEM —SPECIFIC 7.4.3 Mechanical All heat traced or externally heated piping insulated cost uonstructlon U. i.1 Interior I-ignting I-urmsneo as -Dunn orawmgs Tor electric power U U U systems within 30 days of system acceptance. Post Construction 8.7.2 Interior Lighting Furnished O&M instructions for systems and equipment to the building owner or designated representative. HVAC 6.7.2.4 Mechanical HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Post Construction 6.7.2.1 Mechanical Furnished HVAC as -built drawings submitted ❑ ❑ 01 within 90 days of system acceptance. Post Construction 6.7.2.2 Mechanical Furnished O&M manuals for HVAC systems within 0❑ ❑ 90 days of system acceptance. Post Construction 6.7.2.3 Mechanical An air and/or hydronic system balancing report is ❑ provided for HVAC systems serving zones >5,000 ft2 of conditioned area. EnergyGauge Summit@ Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 15 of 16 EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 3/27/2017 Page 16 of 16 EnergyGauge Summit® v5.20 INPUT DATA REPORT Pro_i ect Information Project Name: 16019 TCERDA Orientation: North Project Title: 16019 TCERDA Building Type: Dining: Family Address: 2199 South Rock Rd Building Classification: Renovation to existing building State: Fl, No.of Stories: 1 Zip: 34945 GrossArea: 4018 SF Owner: Sunshine Kitchen Zones No Acronym Description Type Area Multiplier Total Area [sfJ [sfl 1 AHU-2 Zone 1 CONDITIONED 1524.0 1 1524.0 ❑ 2 AHU-3 Zone 2 CONDITIONED 714.0 1 714.0 ❑ 3 AHU-1 Zone 3 CONDITIONED 740.0 1 740.0 ❑ 4 TMAU-1 Zone 4 CONDITIONED 400.0 1 400.0 ❑ 5 TMAU-2 Zone 5 CONDITIONED 400.0 1 400.0 ❑ 6 AHU-4 Zone 6 CONDITIONED 240.0 1 240.0 ❑ 3/27/2017 EnergyGauge Summit® v5.20 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] [ft] plier [sf] [cf] In Zone: AHU-2 1 Office 1 Zo0Sp1 Office - Enclosed 9.00 10.00 10.00 1 90.0 900.0 ❑ 2 Office 2 Zo0Sp1 Office - Enclosed 9.00 10.00 10.00 1 90.0 900.0 ❑ 3 Office 3 Zo0Sp1 Office - Enclosed 9.00 10.00 10.00 1 90.0 900.0 11 4 Office 4 Zo0Sp1 Office - Enclosed 9.00 10.00 10.00 1 90.0 900.0 ❑ 5 Office 5 Zo0Sp1 Office - Enclosed 9.00 10.00 10.00 1 90.0 900.0 ❑ 6 Office 6 Zo0Sp1 Office - Enclosed 9.00 10.00 10.00 1 90.0 900.0 ❑ 7 Office 7 Zo0Sp1 Office - Enclosed 8.00 8.00 10.00 1 64.0 640.0 El 8 Office 8 Zo0Sp1 Office - Enclosed 10.00 10.00 10.00 1 100.0 1000.0 ❑ 9 Office 9 Zo0Sp1 Office - Enclosed 10.00 10.00 10.00 1 100.0 1000.0 ❑ 10 W RR Zo0Sp10 Toilet and Washroom 10.00 6.00 10.00 1 60.0 600.0 ❑ 11 M RR Zo0Sp10 Toilet and Washroom 10.00 6.00 10.00 1 60.0 600.0 ❑ 12 CORRIDOR Zo0Spl2 Corridor 5.00 20.00 10.00 1 100.0 1000.0 13 CORRIDOR Zo0Sp12 Corridor 5.00 20.00 10.00 1 100.0 1000.0 14 LOBBY Zo0Sp14 Lobby (General) - Reception 8.00 50.00 10.00 1 400.0 4000.0 and Waiting In Zone: AHU-3 1 KITCHEN Zo0Sp1 Food Service - Kitchen 20.00 20.00 10.00 1 400.0 4000.0 2 OFFICE 10 Zo0Sp2 Office - Enclosed 8.00 8.00 10.00 1 64.0 640.0 ❑ 3 CAGED DRY Zo0Sp3 Storage & Warehouse - 8.00 25.00 10.00 1 200.0 2000.0 Bulky Active Storage 4 CORRIDOR Zo0Sp4 Corridor 10.00 5.00 10.00 1 50.0 500.0 In Zone: AHU-1 1 KITCHEN Zo0Sp1 Food Service - Kitchen 20.00 20.00 10.00 1 400.0 4000.0 2 JANITOR Zo0Sp2 Electrical Mechanical 8.00 8.00 10.00 1 64.0 640.0 Equipment Room - General 3/27/2017 EnergyGauge Summit® v5.20 2 r 3 VESTIBULE ZoOSp3 Corridor 8.00 22.00 10.00 1 176.0 1760.0 4 PrOZo3SP4 ZoOSp4 Electrical Mechanical 10.00 10.00 10.00 1 100.0 1000.0 Equipment Room - General In Zone: TMAU-1 1 KITCHEN Zo0Sp1 Food Service - Kitchen 20.00 20.00 10.00 1 400.0 4000.0 In Zone: TMAU-2 1 KITCHEN ZoOSp1 Food Service - Kitchen 20.00 20.00 10.00 1 400.0 4000.0 In Zone: AHU-4 1 DRY STORACZo0Sp1 Storage & Warehouse - 10.00 24.00 10.00 1 240.0 2400.0 Bulky Active Storage Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: AHU-2 In Space: Office 1 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 ❑ Daylighting In Space: Office 2 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 ❑ Daylighting In Space: Office 3 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 ❑ Daylighting In Space: Office 4 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 ❑ Daylighting In Space: Office 5 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 ❑ Daylighting In Space: Office 6 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 El _ Daylighting In Space: Office 7 1 Compact Fluorescent General Lighting 1 41 41 Occupancy sensor without 1 Daylighting In Space: Office 8 3/27/2017 EnergyGauge Summit® v5.20 I Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 Daylighting In Space: Office 9 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 Daylighting In Space: W RR 1 Compact Fluorescent General Lighting 1 68 68 Occupancy sensor without 1 Daylighting In Space: M RR 1 Compact Fluorescent General Lighting 1 68 68 Occupancy sensor without 1 Daylighting In Space: CORRIDOR 1 Compact Fluorescent General Lighting 2 41 82 Manual On/Off 1 In Space: CORRIDOR 1 Compact Fluorescent General Lighting 2 41 82 Manual On/Off 1 In Space: LOBBY 1 Compact Fluorescent General Lighting 4 41 164 Occupancy sensor without 1 Daylighting In Zone: AHU-3 In Space: KITCHEN 1 Compact Fluorescent General Lighting 4 41 164 Occupancy sensor without 2 Daylighting In Space: OFFICE 10 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 Daylighting In Space:- CAGED DRY STORAGE 1 Compact Fluorescent General Lighting 3 41 123 Occupancy sensor without 1 El Daylighting In Space: CORRIDOR 1 Compact Fluorescent General Lighting 1 41 41 Occupancy sensor without 1 Daylighting In Zone: AHU-1 In Space: KITCHEN 1 Compact Fluorescent General Lighting 4 41 164 Occupancy sensor without 2 El Daylighting In Space: JANITOR 1 Compact Fluorescent General Lighting 1 41 41 Occupancy sensor without 1 Daylighting In Space: VESTIBULE 1 Compact Fluorescent General Lighting 3 41 123 Occupancy sensor without 2 El Daylighting 3/27/2017 EnergyGauge Summit® v5.20 4 In Space: PrOZo3Sp4 1 Compact Fluorescent General Lighting 2 68 136 Occupancy sensor without 1 Daylighting In Zone: TMAU-1 In Space: KITCHEN 1 Compact Fluorescent General Lighting 4 41 164 Occupancy sensor without 2 Daylighting In Zone: TMAU-2 In Space: KITCHEN 1 Compact Fluorescent General Lighting 4 41 164 Occupancy sensor without 2 El Daylighting In Zone: AHU-4 In Space: DRY STORAGE 1 Compact Fluorescent General Lighting 2 41 82 Occupancy sensor without 1 El Daylighting Walls No Description Type Width H (Effec) Multi Area Orientation Conductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [b.sf.FBtu] [Btu/sf.F] In Zone: AHU-2 1 PrOZo1Wal Metal 10.00 15.00 1 150.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt15/8"Gyp 2 PrOZo1Wa1 Metal 10.00 15.00 1 150.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 3 PrOZo1Wa1 Metal 10.00 15.00 1 150.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 4 PrOZo1Wa1 Metal 10.00 15.00 1 150.0 North 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1 Batt/5/8"Gyp 5 PrOZo1Wa1 Metal 10.00 15.00 1 150.0 North 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 6 PrOZo1Wa1 Metal 10.00 15.00 1 150.0 North 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 3/27/2017 EnergyGauge Summit® v5.20 5 7 PrOZo1Wal Metal 10.00 15.00 1 150.0 North 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 8 PrOZo 1 Wa9 Metal 10.00 15.00 1 150.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp In Zone: AHU-3 1 PrOZo2Wal Metal 20.00 15.00 1 300.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 2 Pr0Zo2Wa2 Metal 8.00 15.00 1 120.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp In Zone: AHU-1 1 Pr0Zo3Wa1 Metal 20.00 15.00 1 300.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 2 PrOZo3Wa2 Metal 8.00 15.00 1 120.0 West 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 3 PrOZo3Wa2 Metal 8.00 15.00 1 120.0 South 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 4 Pr0Zo3Wa4 Metal 22.00 15.00 1 330.0 South 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp 5 PrOZo3Wa5 Metal - -- 10.00 15.00 1 150.0 South 0.0920 1.072 19.38 10.9 ❑ siding/2x4@24"+Rl 1Batt/5/8"Gyp Windows No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: AHU-1 In Wall: Pr0Zo3Wa1 1 PrOZ0%l Wil West No 0.4500 0.52 0.57 15.00 8.00 1 120.0 3/27/2017 EnergyGauge Summit® v5.20 In Zone: AHU-2 In Wall: PrOZo1Wa1 1 PrOZolWalWil West No 0.4500 0.52 0.57 4.00 4.00 1 16.0 ❑ 1 PrOZolWalWil West No 0.4500 0.52 0.57 4.00 4.00 1 16.0 ❑ 1 PrOZolWalWil West No 0.4500 0.52 0.57 4.00 4.00 1 16.0 ❑ 1 PrOZol Wal Wil North No 0.4500 0.52 0.57 8.00 8.00 1 64.0 ❑ 1 PrOZolWalWil _North No 0.4500 0.52 0.57 8.00 8.00 1 64.0 ❑ 1 PrOZol Wal Wil North No 0.4500 0.52 0.57 8.00 8.00 1 64.0 ❑ 1 PrOZolWalWil North No 0.4500 0.52 0.57 8.00 8.00 1 64.0 ❑ In Wall: PrOZo1Wa9 1 PrUo1Wa9Wi1 West No 0.4500 0.52 0.57 5.50 6.00 1 33.0 ❑ In Zone: AHU-3 In Wall: PrOZo2Wa1 1 PrUo2WalWil West No 0.4500 0.52 0.57 15.00 8.00 1 120.0 ❑ Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. A. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. SE F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: AHU-2 1 PrOZolRfl Mtl Bldg Roof/R-19 1524.00 1.00 1 1524.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: AHU-3 1 PrOZo2Rfl Mtl Bldg Roof/R-19 1114.00 1.00 1 1114.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: AHU-1 1 PrOZo3Rfl Mtl Bldg Roof/R-19 1140.00 1.00 1 1140.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt 3/27/2017 EnergyGauge Summit® v5.20 In Zone: TMAU-1 1 PrOZo4Rfl Mtl Bldg Roof/R-19 20.00 20.00 1 400.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: TMAU-2 1 PrOZo5Rfl Mtl Bldg Roof/R-19 20.00 20.00 1 400.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: AHU-4 1 PrOZo6Rfl Mtl Bldg Roof/R-19 24.00 10.00 1 240.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sf] [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: AHU-2 1 PrOZolFll 1 ft. soil, concrete 1524.00 1.00 1 1524.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad In Zone: AHU-3 1 PrOZo2Fl1 1 ft. soil, concrete 1114.00 1.00 1 1114.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad In Zone: AHU-1 1 PrOZo3F11 1 ft. soil, concrete 1140.00 1.00 1 1140.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad In Zone: TMAU-1 3/27/2017 EnergyGauge Summit® v5.20 I Pr0Zo4F11 1 ft. soil, concrete 20.00 20.00 1 400.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad In Zone: TMAU-2 1 Pr0Zo5F11 1 ft. soil, concrete 20.00 20.00 1 400.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad In Zone: AHU-4 1 PrMo6F11 1 ft. soil, concrete 24.00 10.00 1 240.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad Systems AHU-2 System 3 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 57700.00 13.00 13.00 ❑ 2 Heating System 36860.00 1.00 ❑ 3 Air Handling System -Supply 2000.00 0.37 ❑ 4 Air Distribution System (Sup) 6.00 ❑ 5 Air Distribution System (Ret) 6.00 ❑ TMAU-1 System 4 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 100000.00 12.40 13.00 ❑ 2 Heating System 69666.00 1.00 ❑ 3 Air Handling System -Supply 1800.00 0.82 ❑ 4 Air Distribution System (Sup) 6.00 ❑ 3/27/2017 EnergyGauge Summit® v5.20 E TMAU-2 System 4 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 100000.00 12.40 13.00 El 2 Heating System 69666.00 1.00 3 Air Handling System -Supply 1800.00 0.82 4 Air Distribution System (Sup) 6.00 AHU-1 System 8 Variable Air Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 80000.00 12.50 13.00 ID 2 Heating System 61400.00 1.00 ID 3 Air Handling System -Supply 2750.00 0.83 4 Air Distribution System (Sup) 6.00 ID 5 Air Distribution System (Ret) 6.00 ID 6 Energy Recovery Unit ID AHU-3 System 8 Variable Air Volume Packaged System No. Of Units 1 Component Category Capacity. Efficiency IPLV 1 Cooling System 76000.00 12.50 13.00 - ID 2 Heating System 61400.00 1.00 ID 3 Air Handling System -Supply 2475.00 0.90 ID 4 Air Distribution System (Sup) 6.00 ID 5 Air Distribution System (Ret) 6.00 ID AHU-4 System 13 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 12650.00 21.50 16.00 ID 2 Heating System 17000.00 1.00 ID 3 Air Handling System -Supply 375.00 0.23 3/27/2017 EnergyGauge Summit® v5.20 10 Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit3Cap.Unit UP Rt. Efficiency Loss 1 Gas Instantaneous water heater [Gal] 199000 [Btu/h] 0.9500 [Ef/Et] [Btu/h] ❑ Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] El j Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in] 1 Domestic and Service Hot Water Systems 140.00 0.28 1.25 1.00 No ❑ 2 Cooling Systems (Chilled Water, Brine and 35.00 0.28 0.25 0.50 No ❑ Refrigerant) Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] 3/27/2017 EnergyGauge Summit® v5.20 11 ASHULTp1C1rW User Defined 3 0.4500 0.5200 0.5700 ❑ d-Vy-Fg fm Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.FBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/1b.F] 187 Mat1187 UYF OR PLAS No BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + RI 1 Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N Constructs Used No ' Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1055 Metal siding/2x4@24"+R11Batt/5/8"Gyp No No 0.09 1.07 19.38 10.9 ❑ Layer Material Material Thickness Framing No. IN Factor 1 4 Steel siding 0.0050 0.000 ❑ 2 271 2x4@24" oc + RI 1 Batt 0.2917 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 3/27/2017 EnergyGauge Summit® v5.20 12 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber No No 0.27 34.00 113.33 3.7 ❑ pad Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 3/27/2017 EnergyGauge Summit® v5.20 13 TCERDA YPK TI Location Fort Pierce Florida Building owner TCERDA Program user KJC Company SWC Comments R13 Wall R20 Roof Window U 0 point 4 Window SC 0 point 4 By Sims Wilkerson Cartier Engineering, Inc. Dataset name K:11610191DesignIMechITrane TraceX16019.trc Calculation time TRACE® 700 version Location Latitude Longitude Time Zone Elevation Barometric pressure Air density Air specific heat Density -specific heat product Latent heat factor Enthalpy factor Summer design dry bulb Summer design wet bulb Winter design dry bulb Summer clearness number Winter clearness number Summer ground reflectance Winter ground reflectance Carbon Dioxide Level Design simulation period Cooling load methodology Heating load methodology ir`LUNOT 06:08 PM on 04/14/2016 6.3.1 West Palm Beach, Florida 26.7 deg 80.2 deg 5 15 ft 29.9 in. Hg 0.0760 0.2444 1.1147 4,906.9 4.5604 95.0 78.0 35.0 0.90 0.95 0.20 0.20 Ib/cu ft Btu/lb-°F Btu/h-cfm-°F Btu-min/h-cu ft lb-min/hr-cu ft OF OF OF 400 ppm January - December TETD-TA1 UATD 7 tomvoyrcMmNe EulNfiO, anayeie mn.aro tnm bane System Checksums By Sims Wilkerson Cartier Engineering, Inc. AHU-1 Single Zone Variable Air Volume COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 17 Outside Air: OADBMIB/HR: 94 / 77 / 113 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 3,891 3,891 5 CLG SPACE PEAK Mo/Hr: 6 / 18 OAD_ B: 90 Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 35 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) 0 0 0.00 0 0 0.00 0 -1,552 6.89 TEMPERATURES Cooling Heating SADB 57.0 74.9 Ra Plenum 75.5 68.5 Return 75.5 68.5 Ret/OA 78.8 49.6 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 Glass Solar 6,097 0 6,097 8 8,761 18 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 1,054 0 1,054 1 868 2 Glass/Door Cond -1,900 -1,900 8.44 Cooling Heating Wall Cond 1,294 192 1,486 2 1,326 3 Wall Cond -1,976 -2,276 10.11 Diffuser 2,657 797 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 2,657 797 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0 Main Fan 2,657 797 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 8,446 4,083 12,528 16 10,955 22 Sub Total =_> -3,876 -5,728 25.44 Nom Vent 450 450 AHU Vent 450 450 Internal Loads Internal Loads Infil 0 0 Lights 2,703 676 3,379 4 2,703 5 Lights 0 0 0.00 MinStop/Rh 797 797 People 3,000 0 3,000 4 1,500 3 People 0 0 0.00 Return 2,657 797 Misc 34,130 0 34,130 44 34,130 69 Misc 0 0 0.00 Exhaust 450 450 Sub Total =_> 39,833 676 40,509 52 38,333 77 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 482 -482 0 0 421 1 Ceiling Load -483 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 25,807 33 0 0 Ventilation Load 0 -17,564 77.99 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/UndrSizing 0 0 0 0 0 Exhaust Heat 773 -3.43 ENGINEERING CKS Exhaust Heat -772 -772 -1 OA Preheat Diff. 0 0.00 Sup. Fan Heat 0 0 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 16.9 56.5 Duct Heat Pkup 0 0 0 cfm/ftz 2.68 0.81 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 408.46 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft=/ton 152.17 Btu/hr-ft2 78.86 -22.75 Grand Total =_> 48,761 3,504 78,073 100.00 49,710 100.00 Grand Total ==> -4,360 -22,519 100.00 No. People 6 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 6.5 78.1 60.6 2,513 78.8 65.1 70.8 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 6.5 78.1 Leave DBIWB/HR °F °F gr/Ib 57.0 54.9 61.2 0.0 0.0 0.0 0.0 0.0 0.0 AREAS Gross Total Glass ft2 (%) Floor 990 Part 0 Int Door 0 ExFlr 0 Roof 990 0 0 Wall 952 135 14 Ext Door 0 0 0 HEATING COIL SELECTION CapacityCoil Airflow Ent Lvg MBh cfm °F °F Main Htg -22.5 797 49.6 74.9 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -22.5 Project Name: TCERDA YPK TI TRACE® 700 v6.3.1 calculated at 06:08 PM on 04/14/2016 Dataset Name: 16019.trc Alternative - 1 System Checksums Report Page 1 of 4,, AHU-2 COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 17 Outside Air: OADB/WB/HR: 94 / 77 / 113 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 6,146 6,146 13 Glass Solar 8,818 0 8,818 18 Glass/Door Cond 2,239 0 2,239 5 Wall Cond 2,171 325 2,496 5 Partition/Door 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0 Infiltration 0 0 0 Sub Total =_> 13,228 6,471 19,699 41 Internal Loads Lights 4,314 1,079 5,393 1' People 4,500 0 4,500 ! Misc 10,597 0 10,597 2, Sub Total =_> 19,411 1,079 20,490 4: Ceiling Load 1,587 -1,587 0 I Ventilation Load 0 0 7,994 1 Adj Air Trans Heat 0 0 1 Dehumid. Ov Sizing 0 1 Ov/Undr Sizing 0 0 I Exhaust Heat -494 -494 - Sup. Fan Heat 0 1 Ret. Fan Heat 0 0 1 Duct Heat Pkup 0 0 I Underfir Sup Ht Pkup 0 I Supply Air Leakage 0 0 I Grand Total ==> 34,226 5,469 47,689 100.01 System Checksums By Sims Wilkerson Cartier Engineering, Inc. CLG SPACE PEAK Mo/Hr: 7 / 18 OADB: 91 Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 0 0 9,638 29 2,030 6 2,500 8 0 0 0 0 0 0 0 0 14,167 43 4,314 13 2,250 7 10,597 32 17,161 52 1,454 4 0 0 0 0 0 0 32,783 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 4.0 47.7 40.5 1,910 78.4 63.9 66.0 Aux Clg 0.0 0.0 '0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 4.0 47.7 envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> nternat Loads Single Zone Variable Air Volume HEATING COIL PEAK Mo/Hr: Heating Design OADB: 35 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) 0 0 0.00 0 0 0.00 0 -2,405 16.09 0 0 0.00 -4,082 -4,082 27.31 -2,929 -3,393 22.70 0 0 0.00 0 0 0.00 0 0 0 0 0 0.00 -7,011 -9,880 66.11 Lights People Misc Sub Total =_> veiling Load lentilation Load \dj Air Trans Heat )v/Undr Sizing exhaust Heat )A Preheat Diff. ZA Preheat Diff. ►dditional Reheat Jnderfir Sup Ht Pkup Wpply Air Leakage 3rand Total ==> Leave DBMB/HR °F °F gr/lb 57.0 55.7 64.3 0.0 0.0 0.0 0.0 0.0 0.0 0 0 0 0 -1,251 0 0 0 -8,262 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -5,454 36.50 0 0 0 0.00 389 -2.61 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -14,945 100.00 AREAS Gross Total Glass ft2 (%) Floor 1,580 Part 0 Int Door 0 ExFlr 0 Roof 1,580 0 0 Wall 1,513 290 19 Ext Door 0 0 0 TEMPERATURES Cooling Heating SADB 57.0 82.8 Ra Plenum 77.2 67.5 Return 77.2 67.5 Ret/OA 78.4 59.7 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 AIRFLOWS Cooling Heating Diffuser 1,936 581 Terminal 1,936 581 Main Fan 1,936 581 Sec Fan - 0 0 Nom Vent 140 140 AHU Vent 140 140 Infil 0 0 MinStop/Rh 581 581 Return 1,936 581 Exhaust 140 140 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 7.2 ,. 24.1 cfm/ft2 1.23 0.37 cfm/ton 487.17 ft2/ton 397.58 Btulhr-ft2 30.18 -9.46 No. People _ 9 HEATING COIL SELECTION CapacityCoil Airflow Ent MBh cfm °F Main Htg -15.0 581 59.7 Aux Htg 0.0 0 0.0 Preheat 0.0 0 0.0 Humidif 0.0 0 0.0 Opt Vent 0.0 0 0.0 Total -15.0 Project Name: TCERDA YPK TI TRACE® 700 v6.3.1 calculated at 06:08 PM on 04/14/2016 Dataset Name: 16019.trc Alternative - 1 System Checksums Report Page 2 of 4 AHU-3 COOLING COIL PEAK Peaked at Time: Mo/Hr: 7 / 18 Outside Air: OADB/WB/HR: 91 / 76 / 110 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 3,712 3,712 5 Glass Solar 8,234 0 8,234 11 Glass/DoorCond 1,059 0 1,059 1 Wall Cond 1,177 186 1,363 2 Partition/Door 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0 Infiltration 0 0 0 Sub Total =_> 10,470 3,899 14,369 20 Internal Loads Lights 2,793 698 3,492 ; People 3,500 0 3,500 Misc 28,328 0 28,328 31 Sub Total =_> 34,621 698 35,319 41 Ceiling Load 513 -513 0 1 Ventilation Load 0 0 23,558 3: Adj Air Trans Heat 0 0 I Dehumid. Ov Sizing 0 1 Ov/Undr Sizing 0 0 1 Exhaust Heat -794 -794 - Sup. Fan Heat 0 I Ret. Fan Heat 0 0 I Duct Heat Pkup 0 0 I UnderfIr Sup Ht Pkup 0 I Supply Air Leakage 0 0 I Grand Total ==> 45,605 3,290 72,453 100.01 System Checksums By Sims Wilkerson Cartier Engineering, Inc. CLG SPACE PEAK Mo/Hr: 6 / 18 OADB: 90 Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 0 0 8,766 20 985 2 1,126 3 0 0 0 0 0 0 0 0 10,877 25 2,793 6 1,750 4 28,328 64 32,871 74 503 1 0 0 0 0 0 0 44,251 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/lb Main Clg 6.0 72.5 55.7 2,115 78.9 65.5 73.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 6.0 72.5 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads Single Zone Variable Air Volume HEATING COIL PEAK Mo/Hr: Heating Design OADB: 35 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) 0 0 0.00 0 0 0.00 0 -1,597 7.20 0 0 0.00 -2,126 -2,126 9.59 -1,595 -1,851 8.35 0 0 0.00 0 0 0.00 0 0 0 0 0 0.00 -3,720 -5,574 25.13 Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat Ov/Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat Underflr Sup Ht Pkup Supply Air Leakage Grand Total ==> Leave DBMB/HR °F °F gr/lb 57.0 54.4 59.1 0.0 0.0 0.0 0.0 0.0 0.0 0 0 0 0 -543 0 0 0 -4,263 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -17,436 78.63 0 0 0 0.00 834 -3.76 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -22,175 100.00 AREAS Gross Total Glass ft' (%) Floor 1,023 Part 0 Int Door 0 ExFlr 0 Roof 1,023 0 0 Wall 816 151 19 Ext Door 0 0 0 TEMPERATURES Cooling Heating SADB 57.0 75.5 Ra Plenum 75.6 68.3 Return 75.6 68.3 Ret/OA 78.9 47.1 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 AIRFLOWS Cooling Heating Diffuser 2,339 702 Terminal 2,339 702 Main Fan 2,339 702 Sec Fan 0 0 Nom Vent 450 447 AHU Vent 450 447 Infil 0 0 MinStop/Rh 702 702 Return 2,339 702 Exhaust 450 447 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 19.2 63.7 cfm/ft' 2.29 0.69 cfm/ton 387.35 ft'/ton 169.43 Btu/hr-ft' 70.82 -21.68 No. People 7 HEATING COIL SELECTION CapacityCoil Airflow Ent MBh cfm °F Main Htg -22.2 702 47.1 Aux Htg 0.0 0 0.0 Preheat 0.0 0 0.0 Humidif 0.0 0 0.0 Opt Vent 0.0 0 0.0 Total -22.2 Project Name: TCERDA YPK TI TRACE® 700 v6.3.1 calcula$ed at 06:08 PM on 04/14/2016 Dataset Name: 16019.trc Alternative - 1 System Checksums Report Page 3 of a. AHU-4 COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 15 Outside Air: OADB/WB/HR: 95 / 78 / 118 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 1,009 1,009 29 Glass Solar 0 0 0 0 Glass/Door Cond 0 0 0 0 Wall Cond 0 0 0 0 Partition/Door 0 0 0 Floor 0 0 0 Adjacent Floor 0 0 0 0 Infiltration 0 0 0 Sub Total =_> 0 1,009 1,009 29 Internal Loads Lights 683 171 853 25 People 0 0 0 0 Misc 0 0 0 0 Sub Total==> 683 171 853 25 Ceiling Load 603 -603 0 0 Ventilation Load 0 0 1,816 53 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0 Exhaust Heat -254 -254 -7 Sup. Fan Heat 0 0 Ret. Fan Heat 0 0 0 Duct Heat Pkup 0 0 0 Underflr Sup Ht Pkup 0 0 Supply Air Leakage 0 0 0 Grand Total ==> 1,285 322 3,424 100.00 System Checksums By Sims Wilkerson Cartier Engineering, Inc. CLG SPACE PEAK Mo/Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 683 53 0 0 0 0 683 53 606 47 0 0 0 0 0 0 1,288 100.00 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBIWBIHR ton MBh MBh cfm °F °F ` gr/lb Main Clg 0.3 3.4 2.3 68 87.5 71.1 88.1 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.3 3.4 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> Internal Loads HEATING COIL PEAK Mo/Hr: Heating Design OADB: 35 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) 0 0 0.00 0 0 0.00 0 -381 13.82 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0.00 0 0 0 0 0 0.00 0 -381 13.82 Lights People Misc Sub Total =_> Ceiling Load Ventilation Load Adj Air Trans Heat Ov/Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat Underflr Sup Ht Pkup Supply Air Leakage Grand Total ==> Leave DB/WB/HR °F °F gr/lb 57.0 56.0 65.3 0.0 0.0 0.0 0A 0.0 0.0 0 0 0 0 -195 0 0 0 -195 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -1,170 42.44 0 0 0 0.00 82 -2.98 0 0.00 0 0.00 -1,288 46.72 0 0.00 0 0.00 -2,758 100.00 AREAS Gross Total Glass ft2 (%) Floor 250 Part 0 Int Door 0 ExFlr 0 Roof 250 0 0 Wall 0 0 0 Ext Door 0 0 0 Computer Room Unit TEMPERATURES Cooling Heating SADB 57.0 74.0 Ra Plenum 81.6 67.5 Return 81.6 67.5 Ret/OA 87.5 53.2 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 AIRFLOWS Cooling Heating Diffuser 68 68 Terminal 68 68 Main Fan 68 68 Sec Fan 0 0 Nom Vent 30 30 AHU Vent 30 30 Infil 0 0 MinStop/Rh 68 68 Return 68 68 Exhaust 30 30 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 44.1 - 44.1 cfm/ft2 0.27 0.27 cfm/ton 238.31 ft=/ton 876.27 Btulhr•ft' 13.69 -6.31 No. People .0 HEATING COIL SELECTION CapacityCoil Airflow Ent Lvg MBh cfm °F °F Main Htg -1.3 68 57.0 74.0 Aux Htg 0.0 0 0.0 0.0 Preheat -0.3 68 53.2 57.0 Reheat -1.3 68 57.0 74.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -1.6 Project Name: TCERDA YPK TI TRACE® 700 v6.3.1 calculated at 06:08 PM on 04/14/2016 Dataset Name: 16019.trc Alternative - 1 System Checksums Report Page 4 of 4 AHU-1 AHU-1 Zone Room ** 01 - Janitor 02 - Service Corridor 03 - Kitchen 104 08 - Lobby 09 - Office 1 10 - Office 2 11 - Office 3 12 - Office 111 13 - Office 112 14 - Office 113 15 -'Office 7 16 - Restrooms 17 - Office 115 18 - Office 19 - Circulation AHU-2 AHU-2 04 - Office 107 05 - Hallway - 07 - Kitchen 1,05 AHU-3 AHU-3 06 - Caged Dry Storage AHU-4 AHU-4 Load / Airflow Summary By Sims Wilkerson Cartier Engineering, Inc. Coil Coil Space VAV Floor Cooling Cooling Design Air Minimum Area People Sensible Total Max SA Changes SA ft2 # Btu/h Btulh cfm ach/hr cfm Main Coil Heating VAV Heating Fan Minimum Sensible Max SA % Btu/h cfm Rm Peak` 56 w 0.0 995 1,116 40 2.87 12 30 Rm Peak 154 0.0 9,934 10,293 495- 12.87 149 30 Rm Peak 780 6.0 49,867 66,835 2,122 10.88 637 30 Sys Peak 990 6.0 60,884 78,333 2,657 Sys Block 990 6.0 60,696 78,073 2,657 Rm Peak 440 0.0 17;098 18,120 799 7.26 240 30 Rm Peak 90 1.0 2,696 3,290 120 5.34 36 30 Rm Peak 90 1.0 2,651 3,235 117 5.22 35 30 Rm Peak 90 1.0 3,781 4,400 173 7.69 52 30 Rm Peak 100 1.0 3,452 4,027 165 6.60 50 30 Rm Peak 100 1.0 3,469 4,044. . 166 6.64 50 30 Rm Peak 90 1.0 3,384 3,941 163 7.26 49 30 Rm Peak 72 1.0 1,460 2,021 53 2.94 16 30 Rm Peak 108 0.0 962 1,198 22 0.81 7 30 Rm Peak 100 1.0 1,707 2,329 59 2.34 18 30 Rm Peak 100 1.0 1,707 2,329 59 2.34 18 30 Rm Peak 200 0.0 1,763 2,218 40 0.81 12 30 Sys Peak 1,580 . 9.0 44,427 51,457 1,936 Sys Block 1,580 9.0 40,498 47,689 1,936 Rrn Peak 81 1.0 ' 2,565 3,131 112 5.55 34 30 Rm Peak 45 0.0 462 657 8 0.71 2 30 Rm Peak 897 6.0 50,833 68,910 2,218 9.89 666 30 Sys Peak 1,023 7.0 50,057 68,895 2,339 Sys Block 1,023 7.0 55,716 72,453 2,339 Rm Peak 250 0.0 2,309 3,424 68 1.09 68 100 Sys Peak 250 0.0 2,309 3,424 68 Sys Block 250 0.0 2,309 3,424 68 * This report does not display heating only systems. Percent OA -11600 0 1.9 6.2 -20,157 0 20.6 68.7 -22,519 0 16.9 56.5 -22,519 0 16.9 56.5 -4,141 0 3.3 11.0 -1,107 0 8.7 28.9 -1,147 0 8.9 29.5 -1,933 0 6.0 20.0 -1,397 0 .6.7 22.2 -1,398 0 6.6 22.1 -1,366 0 6.4 21.2 -439 0 17.6 58.7 -339 0 29:8 99.2 -527 0 18.8 62.6 -527 0 18.8 62.6 -627 0 29.8 99.2 -14,945 0 7.2 24.1 -14,945 0 7.2 24.1 -1,031 0 8.8 29.3 -229 0 67.8 100.0 L21,027-- 0- -19:6-65.3--- -22,287 0 19.2 63.7 -22,287 0 19.2 63.7 -1,288 0 44.1 44.1 -1,298 0 44.1 44.1 -1,288 0 44.1 44.1 Project Name: TCERDA YPK TI Dataset Name: 16019.trc TRACE® 700 v6.3.1 oalculated at 06:08 PM on 04/14/2016 Load/Airflow Summary Report Paged of 1