HomeMy WebLinkAboutAPPROVED DBPR product approval 5V 24 gauge 17022.2�n li ltt
Professional Regulation
r�mr�ll
BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
F�Ofldd
Product Approval
�: P
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL17022-R7
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
08/18/2017v. date reapply 08/21/17
Archived
❑
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
fivalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
0 Validation Checklist - Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.Ddf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
2012
2006
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
FL # Model, Number or Name Description
17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2 12 - "5V Crimp" (R6)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions.Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 13 - "1.5" Mechanical Seam" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.4 14 - "1.5" Mechanical Seam" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.5 15 - "1 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with
Installation Instructions
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.Ddf
Created by Independent Third Party: Yes
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Installation Instructions
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.oc,
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
ALUM ssrDdf
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Installation Instructions
FL17022 R7 II FL17022.3 1.5 MECHANICAL
seam 24ga ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL17022.3 1.5 MECHANICAL
seam 24ga ssr.Ddf
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.Ddf
Created by Independent Third Party: Yes
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.Ddf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.Ddf
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.6
6 "1 in. Nail Strip" (R5)
1" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.Ddf
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
17022.7
7 - "1.5 in. Nail Strip" (R5)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.Ddf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.8
8 - "EMAX Rib" (R5)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 177022.8 EMAX Rib ssr.Ddf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.Ddf
limitations of use. Install the assembly in compliance with
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.9
9 - " PER MAX" (R5)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.9 PBR RIB ssr.Ddf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf
limitations of use. Install the assembly in compliance with
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
® ® ez--=
Credit Gard
Safe