Loading...
HomeMy WebLinkAboutBuilding PlansM 8229 U.S. HIGHWAY 1 ST. LUCIE, FLORIDA �O SUMMARY DRAWING SYMBOLS GENERAL NOTES 1.0 APPLICABLE CODES: Room fl) PROJECT DESCRIPTION: 1.1 STANDARD BUILDING CODE E ROOM NAME & NUMBER THE SCOPE OF THIS PROJECT INCLUDES AN APPROXIMATE 2,300 SF INTERIOR SHELL FINISH OUT FOR APPLIANCE SERVICES. THE PROJECT IS LOCATED AT 8229 U.S. HIGHWAY 1. ST. LUCIE COUNTY, FL. MAJOR AREAS OF CONSTRUCTION INCLUDE DEMOLITION OF ALL EXISTING 1997 EDITION DOOR NUMBER MATERIALS, INTERIOR DRYWALL CONSTRUCTION, INTERIOR FINISHES, PLUMBING, HVAC, AND ELECTRICAL EQUIPMENT AND SYSTEMS. 1.2 NFPA 101 1.3 LOCAL FIRE CODE, PLUMBING CODE, MECHANICAL CODE, & ELECTRICAL WINDOW NUMBER CODE - LATEST EDITIONS GENE R AL NOTES: EQUIPMENT NUMBER I THESE DRAWINGS INDICATE THE BASIC DESIGN AND INTENT OF THE DESCRIBED PROJECT. CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH 2.0 BUILDING CODE: LOCAL CODES AND ORDINANCES. ITEMS DEFINED WITHIN THESE CONSTRUCTION DOCUMENTS ARE CONSIDERED TO BE THE BASIC MINIMAL 2.1 OCCUPANCY GROUP: 1 ELEVATION REQUIREMENTS. EQUAL AND APPROVED PRODUCTS ARE ACCEPTABLE. A. MERCANTILE: GROUP M a.iAPPLICABLE INDUSTRY STANDARDS SHALL HAVE SAME FORCE AND AFFECT ON PERFORMANCE OF THE WORK AS IF COPIED DIRECTLY INTO 2.2 TYPE OF CONSTRUCTION (CHAPTER 6): THESE DOCUMENTS. INSTALLATION OF NEW ITEMS SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS UNLESS NEW CONSTRUCTION - TYPE V UNPROTECTED A(� WALL SECTION SECTION DETAIL OTHERWISE NOTED IN THESE DOCUMENTS. RECEIVE,ISTORE, AND HANDLE PRODUCTS, MATERIALS AND EQUIPMENT IN A MANNER WHICH WILL PREVENT LOSS, DETERIORATION, AND/OR 2.3 FIRE RESISTIVE REQUIREMENTS: 0.0.0 ETAIL DETAIL DAMAGE. > EXTERIOR FRAME - 0 HOUR PLAN INTERIOR FRAME - 0 HOUR ANY CUTI ING AND PATCHING SHALL BE DONE IN A MANNER TO MINIMIZE DAMAGE TO EXISTING CONDITIONS. PATCH DAMAGED AREAS TO FLOORS - 0 HOUR PARTITION TYPE MATCH CONDITIONS : OF SURROUNDING SURFACES. ROOF DECK & SUPPORTING MEMBERS - 0 HOUR REFER TO SHEET 8.1 ALL DEMOLITION AND CONSTRUCTION DEBRIS SHALL BE REMOVED OFF OF JOB SITE AND PROPERLY DISPOSED, UNLESS OTHERWISE NOTED. ROOF COVERING - 0 HOUR TOILET ACCESSORY THE EXISjTING ADJOINING AREAS AND/OR SITES SHALL REMAIN IN OPERATION DURING CONSTRUCTION. COORDINATE WORK WITH EXISTING WALLS EXTERIOR REFER TO SHEET 3.6 OPERATIONS AND/OR SURROUNDING SITE CONDITIONS. NOISE AND DUST SHALL BE MINIMIZED. PROTECT THE PUBLIC AND ADJACENT AREAS BEARING - 0 HOUR FROM CCNSTRUCTION HAZARDS AND DUST AND DEBRIS. PROTECT EXISTING SURFACES TO REMAIN FROM DAMAGE DUE TO CONSTRUCTION. NONBEARING - 0 HOUR DATUM ELEVATION DAMAGE[ SURFACES SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE' OWNER. WALLS 1NTERIOft BEARING - 0 HOUR ALL DIMENSIONS ARE TO FACE OF FINISH MATERIALS UNLESS OTHERWISE NOTED. ALL DIMENSIONS SHALL BE VERIFIED PRIOR TO INSTALLATION PARTITIONS - 0 HOUR O COLUMN LINE OF WORK. DO NOT SCALE THE DRAWINGS. REFER QUESTIONS AND DISCREPANCIES TO THE ARCHITECT. ALL NEW CONSTRUCTION SHALL MEET REQUIREMENTS OF THE FLORIDA ACCESSIBILITY CODE AND THE AMERICAN DISABILITY ACT (ADA). NEW WALL CONSTRUCTION ALL INTERIOR FINISHES INCLUDING COLORS AND MATERIALS (EXCEPT AS OTHERWISE NOTED) SHALL BE SELECTED BY THE ARCHITECT OR INTERIOR DESIGNER OF RECORD IF NOT ALREADY IDENTIFIED IN THESE DOCUMENTS, COORDINATE ALL FINISHES WITH ARCHITECT OR INTERIOR NEW WALL CONSTRUCTION DESIGNER OF RECORD. 'INSULATION INSULATION EXISTING 1 HOUR DEMISION WALL NEW BLOCK WALL CONSTRUCTION TABLE OF CONTENTS d 1.1 COVER SHEET ❑ N 2.1 DEMOLITION PLAN ❑ Id 3.1 FLOOR PLAN AND DETAILS ❑ 0 3.2 ELECTRICAL FLOOR PLAN ❑ 0 9.1 REFLECTED CEILING PLAN El 0 10.1 FINISH & DOOR SCHEDULES & ELEVATIONS DETAILS El 0 El ED El 11 1:1 171 11 El D ❑ El F1 El El El ❑ El 171 El 13 El 13 El 13 El ❑ El ST. LIUCIE COUNTY BULDING DIVISION ❑ 0 REVIEWED FOA& Vl�'IANC El 11 REVIEWED BY El 11 DATE :;�A Qj 0% 1 El 11 PLANS AND PERNUT MUST BE KEPT ON JOB El OR NO INSPECTION WILL BE MADE. ❑ El ❑ 1:1 ID ❑ El DATE OF ISSUE REVISIONS IN DRAWINGS THIS ISSUE F­1 DRAWINGS NOT ISSUED ST. LUCIE COUNTY FIRE DISTRICT REVIEWED FOR COMPLIANCE AND SU13JUCT TO FINAL FIELD INSPECTION B ATE: ;4-01 SEE ATTACHED REVISION SHEET 2400 Rhode Island Ave. Tfi,'I: (551) 462-2312 Ft. Pierce, FL 349-13 1:uj;:(,,-61)462-2323 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, ST. LUCIE COUNTY *UILDING DIVISION REVIEWED j FOR C-M MCVIEW �ffy DATE PLANS AND PERMIT MUST ME KEPT ON JOS OR NO INSPECT1,3N WILL SE MADE SHERMAN T. ALLENSON, ARCHITECT 2740 SW Martin Downs Blvd. SUITE #236 Palm City, FL. 34990 (561) 221-9988 221-8535 - fax E-Mail: allonson@bellsouth.net FL # AR-0015819 -Z" 0. LLI < U r-) > 0 LL W a (1) 0 z 0 LL, D 0 1 1 (/� 1 U 0 Z LJ ry < ::D _j u� 0 COVER SHEET Revision / Revision Date: JANUARY 10 2001 REVISE PLAN A Issue Date: 01/31101 Project Number: 0053 Sheet Number: JANUARY 31, 2001 GENERAL DEMOLITION NOTES: RETAIN EX15TING 4' THIG CONCRETE SLAB AND W DEMOLITION NOTES: ALL DEMOLITION WORK SHALL BE COORDINATED WITH ALL AUTHORITIES, UTILITY COMPANIES, AND THE OWNER. VERIFY EXISTING CONDITIONS AND LOCATIONS OF ALL UTILITIES PRIOR TO COMMENCEMENT OF DEMOLITION OPERATIONS. COORDINATE UTILITY SHUT DOWNS WITH THE APPROPRIATE COMPANY. ANY CUTTING AND PATCHING SHALL BE DONE IN A MANNER TO MINIMIZE DAMAGE TO EXISTING CONDITIONS DESIGNATED TO REMAIN. PARCH DAMAGED AREAS TO MATCH CONDITIONS OF SURROUNDING SURFACES TO A POINT FREE OF VISIBLE DEFECTS AFTER COMPLETION OF THE WORK. PROTECT THE PUBLIC AND ADJOINING AREAS FROM CONSTRUCTION HAZARDS AND DEBRIS. SECURE THE CONSTRUCTION AREA AT THE END OF EACH DAY'S WORK, DEMOLISH WALLS, FIXTURES, FINISHES, AND EQUIPMENT WHERE INDICATED ON THE DRAWINGS. DEMOLITION OF WALLS SHALL INCLUDE REMOVAL OF DOORS, WINDOWS, ELECTRICAL, AND/OR MECHANICAL ITEMS EXISTING ON OR WITHIN THE WALLS. REMOVE ALL DEBRIS FROM THE SITE AND DISPOSE AT APPROVED DISPOSAL SITE. ALL DEMOLISHED MATERIAL SHALL BECOME THE PROPERTY AND RESPONSIBILITY OF THE CONTRACTOR, BY ACCEPTANCE OF THIS WORK, IT IS UNDERSTOOD ILLEGAL DISPOSAL OF MATERIAL SHALL BE THE COMPLETE RESPONSIBILITY OF THE CONTRACTOR, NOT THE OWNER, ARCHITECT OR ENGINEER. ELECTRICAL OUTLETS, SWITCHES AND CONTROLS IN EXISTING WALLS TO BE REMOVED SHALL BE ABANDONED AT THE PANEL BOX AND TERMINATED, REMOVE ALL HVAC EQUIPMENT, INCLUDING DUCT WORK, INTERIOR FAN UNITS, AND ROOF TOP UNITS. REMOVE ALL ASSOCIATED ELECTRICAL WIRING TO PANEL BOX. CONDUIT RUN SHALL REMAIN FOR REUSE. REMOVE ALL PLUMBING FIXTURES, WATER SUPPLY LINES AND DRAINS WHERE NOT INDICATED TO REMAIN FOR REUSE. REMOVAL SHALL INCLUDE PROPER CAPPING OF WATER SUPPLY LINES, DRAINS, ROOF VENTS, ETC. PATCH ROOF AT LOCATIONS OF ABANDONED PLUMBING VENT LINES. ROOF PATCHING SHALL MATCH EXISTING ROOF CONDITIONS. 74'-B' REMOVE AND DISPOSE OF ALL EXISTING FLOORING INCLUDING TILE AND CARPETING INCLUDING ALL ASSOCIATED GLUES AND MASTIC. REMOVE AND DISPOSED OF ALL CEILING WORK INCLUDING LIGHTS, HVAC SUPPLY AND RETURN AIR GRILLES, ETC. REMOVE AND DISPOSE ALL EXISTING KITCHEN EQUIPMENT INCLUDING EXHAUST HOOD AND EQUIPMENT, HOOD FIRE SUPPRESSION SYSTEM, AND OTHER EQUIPMENT AS MAY BE EXISTING INSIDE SPACE. REMOVE AND DISPOSE OF ALL EXISTING INTERIOR WALLS AND WALL FINISHES, INCLUDING GYPSUM BOARD DRYWALL ON EXTERIOR BLOCK WALLS. KEEP EXISTING 1x WOOD FURRING STRIPS ON EXISTING BLOCK WALLS FOR REUSE: REMOVE ALL ELECTRICAL WORK INCLUDING MAIN PANEL, WIRING AND CONDUIT TO ABANDONED LOCATIONS, AND WIRING WHERE NOT SCHEDULED FOR REUSE. MAINTAIN ALL CONDUIT RUNS TO PANEL WHERE' CIRCUIT CAN BE REUSED. REMOVE ALL ABANDONED ROOF EQUIPMENT INCLUDING HVAC COMPRESSOR UNITS, PLUMBING VENTS, ELECTRICAL, ETC. PATCH ROOF TO MATCH CONDITIONS OF EXISTING ROOF. G G iA 0 THESEP. ARE S 441r�'SAN ALLPROPQ UJECT T ' QED i RFQUIREDDYFIEI.D ORRECTIOs\ AfftRENEC r� ECTO S COMPLY �1t�°A AI�ORDE10 Ar CABILE C®DES, ST. LUCIE COUNTY BL7LDLVG DI<�STnv REIVIEN1,ED FO REVIEIYEDO LLANNCE' DATE .J1 Nr . vc .rn IlMUSTBEj{EPTONdfv OR \'O LNSPECTIOV IML BE MADE. NOTE. HATCHED AREA INDICATES AREA OF WORK. REMOVE ALL ITEMS INCLUDING FLOORING. CEILINGS. WALLS, MECHANICAL AND ELECTRICAL FIXTURES. REFER TO DEMOLITION NOTES. 1 "W SHERMAN T. ALLENSON, ARCHITECT 2740 SW Martin Downs Blvd. SUITE #236 Palm City, FL. 34990 (561)221-9988 221-8535-fax E-Mail: allenson@bellsouth.net FL # AR-0015819 r 'A' DEMOLITION FLOOR PLAN 1l4"=1'-0" Revision I Revision Date: ,n Issue Date: 12/20/00 Project Number: 0053 Sheet Number: Eli PAPER TOWEL 01'I AND WA5TE RE6. GFGI -Irz E MIRROR PAPER TOWEL 0I5P. OAP DIyP. LDISPENSER INSTALL PADDNG AT EXP05ED PIPES BELOW 51Nx5 LET & URINAL ELEVATIONS Z� HANDICAP ACCESSIBLE DETAILS �NT5 ENAMEL PAINTED WALL TYPICAL O iT 0 N 4 W w BASE AS SCHEDULED TOILET ELEVATION 3/8" = V-0" FLUSH VALVE HANC FACE LAVATORY IN H.C. STALL FLOOR PLAN 1 1/4 = V-0" ENAMEL PAINTED WALL TYPICAL IRROR G 3'-0' DD El I I, 1 "O I, BASE d �`'%1` SC:HEDULULE TOILET ELEVATION 3/8" = 1'-0' ELECTRICAL NOTE: ALL ASPECTS OF THIS PROJECT i SHALL COMPLY WITH THE REQUIREMENTS OF THI5 SHEET. THE STANDARD 13UILDINC CODE. FLORIDA ACCESSIBLE REQUIREMEN AND THE ADA. ENAMEL PAINTED / WALL TYPICAL BASE AS' SCHEDULED A TOILET ELEVATION 3/8" = 1'-0" a/2\ 2 TOILET PLANS 3/8" = 1'-0" TOILET ACCESSORY SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL # COMMENTS GSURFACE -MOUNTED TOILET BOBRICK #B-667 ONE AT EACH TOILET TISSUE DISPENSER 8� SURFACE MOUNTED PAPER BOBRICK #6-262 TOWEL DISPENSER �C WALL -MOUNTED SOAP BOBRICK #B-4112 ONE AT EACH SINK DISPENSER S.S. FRAMED MIRROR BOBRICK #B-293/1830 TILTING AT EACH N.C. ACCESSIBLE SINK SINK GGRAB BARS BOBRICK #B-68137 36" AND 42" LONG AT EACH N.C. TOILET WALL SECTION NOTES: 1. REFER TO FLOOR PLANS FOR LOCATION OF PARTITION TYPES AND TO SCHEDULES & DETAILS FOR WALL FINISHES. 2. ALL GYPSUM WALLBOARD SHALL BE 5/8" THICKNESS. FIRE RATED WALLS SHALL HAVE 5/8" FIRE CODE RATED GYPSUM BOARD. — — -- 3. ALL GYPSUM WALLBOARD SHALL BE MOISTURE RESISTANT AT THE ROOM SIDE OF ALL WALLS FOR ALL TOILET ROOMS, PLUMBING WET WALLS AND WALLS ADJACENT TO PLUMBING WET WALLS, AND ALL WALLS WITH CERAMIC TILE FINISH, INCLUDING DRYWALL CEILINGS SCHEDULED FOR THESE AREAS. 4. SOUND ATTENUATION BLANKETS SHALL EXTEND FULL HEIGHT AND WIDTH OF PARTITIONS. O 5. ALL RATED WALLS SHALL BE CONSTRUCTED FIRST. SECONDARY WALLS SHALL ABUT, NOT PENETRATE, RATED WALLS. 6. SUBMITTAL INFORMATION SHALL BE PROVIDED TO SUBSTANTIATE THAT THE MATERIALS AND ASSEMBLY USED BY THE CONTRACTOR HAVE BEEN TESTED BY A RECOGNIZED TESTING — ` AGENCY TO MEET THE FIRE RESISTANCE RATING SCHEDULED ON THESE PARTITION TYPES. \ 7. FIRE STOPPING SHALL BE PROVIDED AT PENETRATIONS THROUGH RATED PARTITIONS. \ 8. REVIEW PLANS AND PROVIDE GRACING IN PARTITIONS AS REQUIRED FOR CASEWORK, EQUIPMENT, ETC. IF WOOD BLOCKING IS REQUIRED PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING. I 9. SPACING OF WOOD STUDS SHALL NOT EXCEED 16" ON CENTER UNLESS SPECIFICALLY / NOTED OTHERWISE. PAINTED 1xG GAP 2x4 TOP PLATE 1 LAYER 5/8' GYP BD EA. SIDE 2x4 WOOD STUDS 4 3/4' AT 1G' O.G. SILL PLATE A5E'AS SCHEDULED t51UN NOTE .L INTERIt7R PARTITIONS SHALL BE `SIGNET) TO RESIST A LATERAL )AD OF 5 155. PER SQUARE FOOT. TYPICAL FURRING AT EXISTING BLOCK WALLS CEILING FINISH AND HEIGHT AS SCHEDULED FACE OF BLOCK WAL, I LAYER 5/5' GYP BG 3/4' WOOD FURRINGD ON O.G. REUSE EXISTING AT IG' AVAILABLE. a WHERE 3/4' WOOD FURRING bN BLOCK WALL. REUSE EX15TING WHERE AVAILABLE. BASE AS SCHEDULED GONT. TOP RUNNER CEILING FINISH AND HEIGHT A$ SCHEDULED HEAD 1 LAYER 5/5' GYP BD EA. SIDE 2x4 WOOD 5TUD5 AT 1G' O.G. CU5E 2xG WOOD 5TUD5 WHERE 7' WALL 15 INDICATED) -14 ,%r ltp, -..,Vz f4/fY)I 2x4 GONT. SILL PLATE ST. LITCIE r BASE AS NON -RATED NON RATED NON RATED FA INSULATED LOW PARTITION C' ❑ NON -RATED B INTERIO WALL SECTIONS NOT INSULATED V. = 1'-0" r FI OR NISRIOR WALLS HALL BE GLEANED. UCCO AS R QUIRED THEN PROVIDE SKIM GOAT COVER BUIDING. UILDING. Go 70 BE SELECTED. DIMEN51ON NOTE: INTERIOR WALLS ARE GIVENA NOMINAL DIMEN51ON OF 5' FOR STANDARD WALLS AND 7' FOR CHASE WALLS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE FRACTIONAL ADJUSTMENTS. GENERAL PROJECT NOTES: ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. INTERIOR WALL DIMENSIONS ARE 5" NOMINAL (4 3/4" ACTUAL) UNLESS OTHERWISE NOTED. VERIFY ALL EXISTING DIMENSIONS PRIOR TO CONSTRUCTION OF NEW WALLS. WHERE DIMENSIONS ARE NOTED WITH "(VERIFY)", DIMENSIONS MAY VARY UP TO 2" AS BASED ON EXISTING CONDITIONS. IF DIMENSIONS VARIES MORE THAN 2" DUE TO EXISTING CONDITIONS, IMMEDIATELY NOTIFY ARCHITECT OR OWNER OF DISCREPANCIES. COORDINATE AND INSTALL MINIMUM 2x6 WOOD BLOCKING ATTACHED TO ALL STUDS REQUIRED FOR CABINETRY (BOTH UPPER AND LOWER CABINETS), PLUMBING FIXTURES INCLUDING WALL HUNG SINKS, TOILET ACCESSORIES INCLUDING GRAB BARS, AND ALL OTHER MECHANICAL AND ELECTRICAL DEVICES AS NEEDED. ALL EXISTING DAMAGE AND ANY DAMAGED CAUSED BY CONSTRUCTION TO ALL EXISTING RATED WALLS, CHASES, OR OTHER EXISTING FINISHES, SHALL BE REPAIRED BY THE CONTRACTOR AS A PART OF THIS WORK. CONTRACTOR SHALL SURVEY EXISTING CONDITIONS FOR REPAIRS PRIOR TO SUBMISSION OF BIDS AND START OF WORK. VERIFY FINAL INTERIOR FINISHES WITH OWNER, COORDINATE ALL OWNER SUPPLIED EQUIPMENT AND MATERIALS DIRECTLY WITH OWNER. FOLLOWING COMPLETION OF DEMOLITION AND PRIOR TO START OF WALL CONSTRUCTION, LEVEL AND SMOOTH OUT EXISTING CONCRETE SLAB USING GYPSUM BASED FLOOR LEVELING COMPOUND SUITABLE FOR INSTALLATION OF CARPET OVER MATERIAL. LEVEL FLOOR TO 1/4" IN 10' TOLERANCE. SHERMAN T. ALLENSON, ARCHITECT 2740 SW Martin Downs Blvd. SUITE #236 Palm City, FL. 34990 (561)221.9988 221-8535-fax E-Mail: allenson@bellsouth.net FL # AR-0015819 (10 < ry o z LL_ > o O 0 z 0 W U -I LLl ry Q U _ U _J �D W®R� FLOOR PLAN ' BUILDLNG DMS10- �IAn� E W� 1 [ ST O, JOB 'M LBEIN1DE, Revision / Revision Date: REVISERPLA 2O01 ©JANUARY 31, 2001 CODE REVISIONS A Issue Date: 12/20/00 Project Number: 0053 Sheet Number: Y, LOAD GENTE'R SOHEDULE "L' 120/240 VOLTS 1 PHASE 3 W1R 225 AMP BU5 30 BRANCH POLES X FULL NEUTRAL FLUSH MOUNTING 225 AMP MAIN LUG SHORT GIRGUIT 1= 10,000 AMP-5YM-RM5 COND. + WIRE AMPS LOAD BKR G K T B U 5 G K T BKR LOAD AMPS GOND. + WIRE A B P A P A A' 8 1/2' #12 8 LIGHTING 1 20 1 1 2 1 20 RECEPTACLES G 1/2' #12 11 3 4 8 12 5 G 8 5 7 8 8 3 - VIA TIME CLOCK 9 10 G 8 APPLIANCE 11 12 q 8 REFRIGERATOR 13 14 8 G I TELEPHONE 15 1G q G I EQUIPMENT 17 18 G 1' #G 47 RTU #1 2 GO 19 1 1 20 1 SPARE 47 1 1 1 21 1 22 J l 47 1 RTU #2 2 GO 23 1 24 SPACE 47 1 l l 25 2G SPACE 27 28 1 2q 30 TOTAL AMPS BUS A= 133 BUS B= 128 CONNECTED KVA,= ELECTRICAL NOTES: 1.ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL NEW ELECTRICAL WORK INDICATED. CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND APPLICABLE SPEOIFICATIONS.IF A PROBLEM IS ENCOUNTERED 1N COMPLYING WITH THIS REQUIREMENT, CONTRACTOR SHALL NOTIFY THE OWNER OR HIS REPRESENTATIVE AS SOON AS POSSIBLE AFTER DISCOVERY OF THE PROBLEM AND SHALL NOT PROCEED WITH THAT PORTION OF THE WORK UNTIL OWNER HAS DIRECTED CORRECTIVE ACTION TO BE TAKEN. 2.ELECTRICAL CONTRACTOR SHALL VISIT JOB SITE AND FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING ELECTRICAL AND TELEPHONE INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF. 3.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE THE NATIONAL ELECTRIC CODE, THE STANDARD BUILDING CODE AS MODIFIED BY THE PALM BEACH COUNTY AMMENDMENTS. 4.D0`NOT SCALE THE ELECTRICAL`bRAWINCS.REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT. CONFIRM WITH OWNERS REPRESENTATIVE. 5.MINIMUM WIRE SIZE SHALL BE #12 A.W.C. EXCLUDING CONTROL WIRING. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER WITH THHN INSULATION, 6.OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR°DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 7:CONTRACTOR'sOALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FROM A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE. &CORRECTION OF DIY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALI- INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THERE BY. 9.ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 10.CONTRACTOR SHALL PAY FOR ALL PERMITS. FEES, INSPECTIONS AND TESTING. CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. 11.THE ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF POWER AND TELEPHONE COMPANIES. 12.CONTRACTOR SHALL COORDINATE WITH MECHANICAL DRAWINGS AND PROVIDE ALL NECESSARY CONTROL WIRING. 13.ALL CIRCUIT BREAKERS FEEDING MECHANICAL EQUIPMENT SHALL BE HACR TYPE CIRCUIT BREAKERS OR FUSED SWITCHES AS INDICATED. 14.PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, BOXES, COVER PLATES, DEVICES FOR ALL OUTLETS AS INDICATED. 15.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED OF HIS WORK. 16.ELECTRICAL CONTRACTOR SHALL LABEL EXTERIOR OF ALL PANELS AND A PROVIDE COMPLETE TYPEWRITTEN DIRECTORIES. 17.ALL ELECTRICAL AND TELEPHONE/DATA OUTLETS TO BE AT 16" AFF o,.. .UNLESS NOTED OTHERWISE, VERTICALLY MOUNTED. m 18.ALL LIGHT SWITCHES TO BE AT 42" AFF. 191AY IN LIGHT FIXTURES TO BE SUPPORTED AT ALL FOUR CORNERS AND - SECURED TO STRUCTURE ABOVE. 20.ALL ELECTRICAL WIRING SHALL BE THE RESPONSIBILITY OF THE v ELECTRICAL CONTRACTOR. ALL ELECTRICAL WIRING FOR HVAC SYSTEM 3- INCLUDING CONTROLS, THERMOSTATS, POWER, ETC. SHALL BE THE + RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. o 3 R 21.PANELBOARDS: ALL CURRENT CARRYING BUSES SHALL BE COPPER. ALL GROUND BUS BARS SHALL BE COPPER. PANELBOARD ENCLOSURES SHALL BE FURNISHED WITHOUT PRE —PUNCHED CONCENTRIC HOLES.AIC RATINGS SHALL n BE AS INDICATED ON PANELBOARD SCHEDULES 0 0 22.DISCONNECT SWITCHES SHALL BE H.P. RATED,HEAVY DUTY, ENCLOSURES 3 AS REQUIRED BY EXPOSURE. a 0 e? 23.CONTRACTOR SHALL CONFIRM WITH FPL ANY AND ALL REQUIREMENTS SUCH AS: LUG SIZE RESTRICTIONS, CONDUIT ENTRY, TRANSFORMER SIZE, o SCHEDULED DOWN TIME FOR .OWNERS CONFIRMATION, ETC. ANY CONFLICTS C SHALL BE BROUGHT TO ATTENTION OF THE ENGINEER BEFORE PROCEEDING o WITH ANY WORK. 24.ALL SERVICE CONDUIT AND ALL EXPOSED EXTERIOR CONDUITS SHALL BE RIGID. INTERIOR LIGHTING AND RECEPTACLE CONDUIT MAY BE EMT. w EXTEND 1 1/4'C W/PULLWIRE TO TEL. SERVICE ENTRY LOCATION. TERMINATE 3/4'C W/PULLWIRE 6' ABOVE CEILING. 2'X4' TEL. BR TYP. DATA OUTLET. SEE PLAN FOR EXACT NUMBER REQUIRED, TERMINATE 3/4'C W/PULLWIRE 6' ABOVE CEILING. TYR TEL. OUTLET. SEE PLAN FOR EXACT NUMBER REQUIRED. TELEPHONE/DATA RISER DIAGRAM STALE -NTS - -- RTU #2 ROOFTOP REC. GFI 64 A- A-17 260 1 'C-2 #6 W/#10 GND. A-23,25 EXISTING WIREWAY, NEW METER +_ MAIN G.B. PANEL 2P 'A' 225A 1 "C-2 #6 W/#10 GND. A-19,21 NEW 2'C-3 #4/0 THHN CU W/#4 THHN CU. GND. ELECTRICAL RISER DIAGRAM St„iLENTS LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NO. LAMPS A DAYBRITE 2TG-432-RS-01-1/4EB-120 (4)F32 T8 B DAYBRITE 2TG-232-RS-01-1/2EB-120 (2)F32 T8 C CAPRI SL523a-120 (1)60W A19 X FUTURA VA3R-SA INCLUDED Y FUTURA ARC2-4-SE INCLUDED LIGHT FIXTURE SCHEDULE NOTES: 1. ANY SUBSTITUTE LIGHT FIXTURES SHALL BE EQUAL TO SPECIFIED FIXTURES. ELECTRICAL LEGEND: RECESSED 2'X4' FLUORESCENT, RECESSED DOWNLiGHT. EXIT LIGHT. (} SURFACE LIGHT LIGHT FIXTURE ,TYPE DESIGNATION. DUPLEX RECEPTACLE. QUAD—PLEX RECEPTACLE. ® SPECIAL PURPOSE OUTLET AS REQUIRED, 0 JUNCTION DOX. 4" SQUARE UNLESS NOTED. ® DATA/PHONE DUPLEX OUTLET. ® TELEPHONE OUT'_EL WP WEATHERPROOF GFI GROUND FAULT INTERRUPTER. $ TOGGLE TYPE WALL SWITCH. $3 TOGGLE TYPE 3 WAY WALL SWITCH, E LE l; TR I U AL PLAIN ______ 11HY REMARKS 2X4 RECESSED TROFFER. 2X4 RECESSED TROFFER. UTILITY LIGHT. LED EXIT W/BATTERY, EMERGENCY W/BATTERY, SHERMAN T. ALLENSON, ARCHITECT 2740 SW Martin Downs Blvd. SUITE #236 Palm City, FL. 34990 (561)221-9988 221-8535-fax E-Mail: allenson@bellsouth.net FL # AR-0015819 0 z_ i 0 0 z 0 W U L1I ry Q U _J i a 1 /4"=1'-0" Revision / Revision Date: 2001 REVISEPL RAI\I A n�n C� Issue Date: 01/10/01 Project Number: 0053 Sheet Number: CEILING NOTES CALL AREAS AS N®TED BELOW) 24'x48' SQUARE -EDGE LAY -IN CEILING TILES AT 9'-O- A.K.P,` AS BASED ON TOP OF EX15TING 5TORE�RONT FRAMES. 2'x4' 4 TUBE FLUQkE5CENT LIGHT FIXTURES WITH ST4hDARD ACRYLIC LENS. INSTALL 3- R-11 KRATFT FACED GATT INSULATION ON TOP OF WALL CEILING TILE5 �A 'A' A-1 I I Ii I I IO BREA14 R001 a i l 1 5 I I I I � I I r. c 1►. II A-7 / --- ----- II A- o; O HC / A-7 CORRIDOR R 109 GHT LIGHT r ILL_ Y A O A YTLICI PEN OFFICES108NIT — ---- --- -- / -n — ---- --- -- L:A_ II it n 0 TELEPHONE II I i IFY _ __ -- _. O A I }— OFFICESmo 110 _ A-7 Q ❑0 0 110 0 Cl ►YI Cn I- - - - -- ----------- - -... - r- _-- — -- - — ---- - 4 m— _— EXISTING n -- - -- — -- --------1 / 1ILL- Li 21'-4' 17'-4' 3G'-O' ` S o 74'-8 R v1EtVED °C1 rY o ' VERIFY E�E1V FOR B, o04 li EcrtON w'z1Q,ST �Ere,V �, i L Vq Q 0 REFLECTED CEILING PLAN SHERMAN T. ALLENSON, ARCHITECT 2740 SW Martin Downs Blvd. SUITE #236 Palm City, FL, 34990 (561)221-9988 221-8535-fax E-Mail: allenson@bellsouth.net FL #AR-0015819 .. U _j z �= o �- o 0 z Q w U w ry Q U U CL U) REFLECTED CEILING PLAN 1/4"=1'-0" Revision / Revision Date: JANUARY 10 2001 REVISE PLAN JANUARY 31, 2001 CODE REVISIONS Fsrl��s Q �i CEILING NOTE: CALL AREAS AS NOTED BELOW) 24'x4B' SQUARE EDGE LAY -IN CEILING TILES AT 9'-O' A.F.F. AS BASED ON TOP OF EXISTING STOREFRONT FRAMES. 2'x4' 4 TUBE FLUORESCENT LIGHT FIXTURE5 WITH STANDARD ACRYLIC LENS. INSTALL 3' R-11 KRATFT FACED GATT INSULATION ON TOP OF WALL CEILING TILES Issue Date: 12/20/00 Project Number: 0053 Sheet Number: i 4 s PROJECT FINISH MATERIALS AND NOTES: GENERAL FINISHES NOTES: PRIOR TO START OF WORK, CONTRACTOR SHALL VERIFY ALL INTERIOR FINISHES WITH OWNER. SUBMIT SAMPLES FOR APPROVAL OF ALL INTERIOR FINISHES TO OWNER FOR APPROVAL PRIOR TO START OF INTERIOR FINISH WORK. PRIOR TO INSTALLATION OF ALL FINISHES, PREPARE SURFACES (INCLUDING CONCRETE SLAB AND DRYWALL SURFACES) PER REQUIREMENTS OF FINISH MANUFACTURER. MARK MANUFACTURER PRODUCT COLOR COMMENTS FLOOR FINISHES: CARPET CPT-1 TO BE SELECTED BY OWNER VINYL COMPOSITION TILE VCT-1 ARMSTRONG EXCELON (OR EQUAL) TO BE SELECTED BY OWNER BASES VINYL BASE VB-1 MERCER (OR EQUAL) 4" RUBBER COVE TO BE SELECTED BY OWNER WALL FINISHES PAINT PNT-1 BENJAMIN MOORE EGGSHELL FINISH TO BE SELECTED BY OWNER OR EQUAL PNT-2 BENJAMIN MOORE LATEX ENAMEL TO BE SELECTED BY OWNER OR EQUAL CEILING FINISHES ACOUSTICAL CEILINGS ACC-1 ARMSTRONG 24' x 48" SQUARE EDGE ALL AREAS UNLESS NOTED OTHERWISE s� u' nay Y 34 00 Y , T. { F =r oLO o M Q,. a• m 0 I O m Jn o FINISH SCHEDULE z4 ARE O !n m WALLS z :10 v z REMARKS N E S W 101 SHOWROOM CPT-1 VB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACC-1 q'-O' 102 OFFICE CPT-1 VB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACC-1 q'-O' 103 MEN'5 MG TOILET VCT-1 VB-1 PNT-2 PNT-2 _ PNT-2 PNT-2 ACC-1 8'-0' 104 WOMEN'S HG TOILE VCT-1 VB-1 PNT-2 PNT-2 PNT-2 PNT-2 ACC-1 8'-0' 105 BREAK ROOM VCT-1 VB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACC-1 9'-0' 1OG CORRIDOR VCT-1 VB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACC-1 ACC-1 q'-O' q'-0' 107 TELEPHONE VCT-1 VB-1 PNT-1 PN1-1 PNT-1 PNT-1 108 OPEN OFFICES CPT-1 VS-1 PNT-1 PNT-1 PNT-1 PNT-1 ACC-1 q'--O' 1Oq CORRIDOR CPT-1 VB-1 PNT-1 PNT-1 PNT-1 PNT-1 ACC-1 ACC-1 q'-O' q'-O' 110 OPEN OFFICES CPT -1 VB-1 PNT-1 PNT-1 PNT-1 PNT-1 DOOR SCHEDULE Al a SIZE a < :2 z o _J W DESCRIPTION IL p = REMARKS W _ = ~ 101A EXISTING DOOR - NO WORK 1015 EXISTING DOOR - NO WORK 101G EXISTING DOOR - NO WORK 103 1 3'-0 G'-B' 1 3/8' WD ® PREHUNG WOOD HOLLOW GORE WD 104 1 3'-O' G'-8' 1 3/8' WD © PRE -HUNG WOOD HOLLOW GORE WD TOGA 1 3'- G'-8' 1 3/8' WO © PREHUNG WOOD HOLLOW GORE WE) 10GB 1 3'-O 7'-0' 1 3/4' HM © HOLLOW METAL - INSULATED HM NEW DOOR IN EXISTING OPENING VERIFY 51ZE 110 1 3'-0' G'-8' 1 3/5' WD © PRE•,HUNG WOOD HOLLOW GORE WO DOOR SCHEDULE NOTES: ALL DOORS TO BE UNDERCUT TO 5/8" ABOVE FINISH FLOOR AND/OR FINISHED THRESHOLD. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE BIRCH AS SCHEDULED. ALL WOOD DO IRS TO BE HOLLOW CORE WOOD. ALL EXTERIOR HOLLOW METAL DOORS TO BE 18 GA. DOORS AND 16 GA FRAMES, PAINTED. DOOR HARDWARE: FINISH: AS SELECTED BY OWNER MANUFACTURER: 'SCHLAGE OR EQUAL - LEVERED HANDLES MEETING ACCESSIBILITY CODES. LOCKSET LATCHSET: ST. LVCIE COUNTY BUILDING DIVISION REVIEWED FOR LIANCF EXTERIOR DOORS - KEYED ALIKE - VERIFY WITH OWNER REVIEWED B W f r PRIVACY LATCH SETS AT BOTH TOILET ROOM DOORS DATE o LOCKSET AT ALL OTHER DOORS PLANS ANDIPEMT MUST BE KEPT ON JO CLOSER: IN TALL�D ON INSIDE OF EXTERIOR DOORS OR NO ]015PECTION WII L BE AiADE. N OTE= VERIFY ALL OPENING SIZES 6' 2'-0' G' TEMPERED GLA55 FOR DOORS. o o QL'6 �D r°TTO'Af oQ'�� d" fi?AYQS z I, Srp R el FA'f''"FLOOF iL HOLLOW METAL - INSULATED PREHUNG PAINTED WOOD HOLLOW {HETAL - INSULATED PAINTED DOOR + FRAME DOOR + FRAME PAINTEC) DOOR + FRAME DOOR ELEVATIONS 6 65 SHERMAN T. ALLENSON, ARCHITECT 2740 SW Martin Downs Blvd. SUITE #236 Palm Clty, FL. 34990 (561)221-9988 221-8535-fax E-Mail: allenson@bellsouth.net FL # AR-0015819 In <C �r o z CC U I— CD O W U W ry Q U __1 FINISH SCHEDULE DOOR SCHEDULE DETAILS Revision / Revision Date. 10 2001 1�JANUARY REVISE PLA OEAREIS OtC VIS62001 0 L� Issue Date: 12/20/00 Project Number: 0053 Sheet Number: w RHEEM RLMA AO@ 12.0 SEER PACKA( ON ROOF. B01701 UNIT BOLTED TO' EXIST. CURB W/ F1 AR HOOD SET AT NOTE: TYP. EXISTING PANEL PROVIDES ENOUGH ROOM FOR ADDITIONAL ELECTRICAL CIRCUITS BREAKERS FOR FIRE WARNING SYSTEM. AII2 CONE) IT ION IN_r—:s-SCHEDUL� . UNIT # A/C TONAGE HEATSTRIP KVA AIR HAND CFM NAME MFG. CAT. # VOLT PHASE VA WATTS 5 1 2000 RHEEM '208 I_ 8400 C. 5 1 200Q RHEEM 1208 1 8400 PROVIDE WP (GFI) — OUTLET FOR SERVICE NEMA 3R WP FLI5ED D15CONNECT FUSE AT MAXIMUM 512E ALLOWED 8Y EQUIPMENT MANUFACTURER A/C UNIT 1" C. TO ELECTRIC PANEL " 16 IN 1/2" CONTROL WIRING TENANT PANEL THERMOSTAT MOUNTED IN TENANI SPACE TENANT A/C WIRING DI,AGRA�*1 &FLIT 5Y5TEM NT5 FIRE EQUIPMENT LEGEND M L QESCCRIPTION Q SMOKE DETECTOR D FIRE PULL STATION E® ILLUMINATED EXIT L'G';T EMERGENCY LIGHT FIRE EXTINGUISHER :Jc STROB LIGHT ® FIRE STAT DEVICE / RETURN AIR ONLY FRESH AIR SUPPLY W/ DAMPER AND BIRD WIRE PROVIDED IN CONTAINED EXTERIOR UNIT, (SEE UNIT MFG. F PECS.) A/C 'UNIT BOLTED TO w` WITHSTAND HURRICANE FORCE WINDS SPRING VIBRATION ISOLATORS (TYP,) LAIR CONDITIONING --- EXIST, FLANG UNIT (ON ROOF) 6' ,i PITCH PAN ROOF — EXIST. FLANG ANCORED TO ROOF UNIT M'j0NT .T.S. ff�. 4 duct round strap maximum no. of diameter hangers hangers spacing hangers 4a 18" S gaga w1re 1' X 16 gash 10'-0" 1 19" fhru 36' 6 gaga wire 1' x 12 gala 10'-0' 37' Qhru 50' 6 gaga wire 2" x 16 gaaa 10'-0' _S - 51' Ihrsa 34' 6 gala care 2" x 16 gau 10'-0" ALL HANGEF MUST BE SECURELY ATTACHED TO A STRUCTURAL MEMBER ANO NOT TO THE ROOF DECK. * - BATTERY BACKUP 11 II � AIR CONDITIONING PLAN 1/4" - 1'-0" rI 'i t .I4AWxERZ FOR ROUND DUCT SCALE:1 112"-1'-0" E_TAI L AC-34 hanger strap 3/6" 6oiUnat 2' wade band same size as hanger strap on flex duct TEXIi1NQ o a a SH WR00 1 1 16'x15' i i j ITYP. 1 FE o E RHE OI� EXIT AIR M RLM ER. B , CURB A060 >OIGvI W/ FRESH AT 245 L000 bF rT CF 2 2 'X24' E B CF 6) UPPLY n AIR 23 • c, II { EXISTING ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR LIANCg REVIE"T BY fiU , J, DATE z I o S PLAN.KN S AN P IT MUST BE KEPT ON JO f OR NO INSPECTION WILL BE Ni.A nr. �s. ` _ A. J. to DATE I 1 20- 01 SCALE AS NOTED JOB, NO, 21187 SHEET AC-1