HomeMy WebLinkAboutEnergy CodeWho'.e' gilding Performance Method for Commercial Buildings Form 40OA-97
ENERGY EFFICIENCY CODE FOR BUILDING•CONSTRUCTION
Florida Department of Community .Affairs,
FLA/COM-97 Version -2 2
PROJECT NAME APPLIANCE SERVICE PERMITTING OFFICE:
ADDRESS: _FT. PIERCE
_FLORIDA
OWNER:" APPLIANCE SERVICE
AGENT:
_Fort Pierce
CLIMATE.ZONE: _6
PEHRMIT NO: .- ' _FT—PIERCE
ES
BUILDING TYPE: _Business (Office) ARE SUBJECT TOMYCORRECTIU S
CONSTRUCTION CONDITION: Existing Building g;
DESIGN COMPLETION: Renovation REQUIRED BY F+L�p SPECTORS THAT
CONDITIONED FLOOR AREA: _2304 �� )A°lY�r' � ��1TO
MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5 W.!TH ALL APPU 9CAB E CODES,
COMPLIANCE CALCULATION:
METHOD A DESIGN CRITERIA RESULT
----------------- -------------- ------
A. WHOLE BUILDING 65.75 100.00 PASSES
PRESCRIPTIVE REQUIREMENTS:
LIGHTING
LIGHTING CONTROL REQUIREMENTS
PASSES
HVAC EQUIPMENT
COOLING EQUIPMENT
1. SEER
10.00
9.70
PASSES
HEATING EQUIPMENT
1. Et
10.00
N/A
AIR DISTRIBUTION'SYSTEM INSULATION
REQUIREMENTS
1. Unconditioned Space
6.-00
4.20
PASSES
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
STATER HEATING EQUIPMENT
1. COP
0.92
0.00
N/A
PIPING INSULATION REQUIREMENTS
-1. -Circulating
----------------------------------------------------------------------------
1..0.0
.1_.-0.0
-PASSES
-COMPLIANCE CERTIFICATION:
4 hereby certify that t e plans
spe-ci-fications cover -by -his
lation are in co m 'anc it
Florida Energy cie 'y e.
PREPARED BY: -
DATE:
I hereby certify that't.has , building is
in compliance with- the- Florida `gin -
Efficiency Code . +'/
DWNER/AGENT :1Z;/
DATE • l = a ��- 01
Review of the plans and specifica-
tions covered by -this .cal-culation
indicates compliance with the
Florida Energy Efficiency Code.
Before construction is completed,
this building will be inspected
for compliance in accordance with
NYLIAACE
lorida Statutes.
BUILN3L ILD1\G DIVISIO\
DATE:
DATE
PLANS Ak\'D ERNI T JiL ST BE �JEPT ON JO►
OR NO INSPECTION WILL BE JLADE.
I hereby certify(*) that the system design is in compliance with the Florida
ErtergyEf f iciency Code.
SYSTEM DESIGNER REGISTRATION/STATE
ARCHITECT
MECHANICAL•
PLUMBING
ELECTRICAL•
LIGHTING
(*) Signature is required where Florida law requires design to be performed
by -registered design professionals. Typed names and registration numbers may
be used where all'relevant information is contained on signed/sealed plans.
BUILDING ENVELOPE SYSTEMS
COMPLIANCE
1•
CHECK
401.------GLAZING--ZONE 1------------------------------------------------ v-
Elevation Type U SC VLT Shading
--------------- ---- ---- ---- --------------
Area(Sgft)
----------
---------
East Residential 1.16 1 1 None
158
North Residential 1.16 1 1 None
138
North. Residential 1.16 1 1 None
52
South Residential 1.16 1 1 None
52
South Residential 1.16 1 1 None
125
South- Residential 1.16 1 1 None
7
Total Glass Area in Zone 1 =
532
Total Glass Area =
532
492.--- --- WALLS --ZONE 1------------------------------------------------
---
Elevation Type U Insul R
------------
Gross(Sgft)
-----------
-----------------------------------------
Easst 5/8"8tco/8"CMU/3/4"ISO BTWN24moc 0.149 4
277
West 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4
277
North 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4
673
South 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4
673
Total Wall Area in Zone 1 =
1901
Total -Gross -Wall Area =
1901-
4G3------- DOORS --ZONE 1------------------------------------------------
---
Elevation Type U
-----
Area(Sgft)
----------
---------------------------------------------------
North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60
20
West 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60
20
Total Door Area in Zone 1 =
41
Total Door Area =
41
404------- ROOFS --ZONE 1------------------------------------------------
---
Type Color U Insul R
------ ----- -------
Area(Sgft)
----------
--=---------------------------------
Built-up Gravel/2" ISO/Mtl Deck Medium .065 19
2304
Total Roof Area in Zone 1 =
2304
Total Roof Area =
2304
405------- FLOORS -ZONE 1------------------------------------------------
---
Type Insul R
-------
Area(Sgft)
----------
------------------------------------------------
Slab on Grade/Uninsulated 0
2304
Total Floor Area in Zone 1 =
2304
Total Floor Area =
2304
406------- INFILTRATION --------------------------------------------------
---
-I
CHECK
Infiltration Criteria in 406.1.ABCD have been met.
MECHANICAL SYSTEMS
CHECK
-.='---------------------------------------------------------------
HVAC load sizing has been performed. (407.1.ABCD)
----
---
407.------COOLING SYSTEMS-----------------------------------------------
---
Type No Efficiency IPLV
4
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --------------
Tons
- - - - - - - - - -
1. Single Package 2 10 .83
5.00
408------- HEATING SYSTEMS-----------------------------------------------
---
Type No Efficiency
BTU/hr
1. Electric Resistance 2 10
34000
409.------VEN'1'11,Pit'lUN--------------------------------------------- - -
ICHECK
"Ii Vektilation Criteria in 409.1.ABCD have been met. 1
410.-----AIR DISTRIBUTION SYSTEM -------------- --------------------------
CHECK
------------------------------------------------------------ ----
Duct sizing and design have been performed. (410.1.ABCD)
AHU Type Duct Location R-value
----------------------------- - - - - ------------------ - - - - ---------
1. Air Conditioners Unconditioned Space 6
CHECK
------------------------------------------------------ ----
Testing and balancing will be performed. (410.1.ABCD)
411------ PUMPS AND PIPING -ZONE -------- 7--------------------------------
Basic prescriptive requirements in 411.1.ABCD have been met.
PLUMBING SYSTEMS
411------ PUMPS AND PIPING -ZONE 1 ---------------------------------------
Type R-value/in Diameter Thickness
---------------------------------------------------
1. Circulating 4 .75 1
412------ WATER HEATING SYSTEMS -ZONE I ----------------------------------
Type Efficiency StandbyLoss InputRate Gallons
----------------------------------------------------------------
1. Other (Heat Recovery,Sol .92 1 42000 40000
ELECTRICAL SYSTEMS
CHECK
413.-----ELECTRICAL POWER
DISTRIBUTION----------------------------
-----
Metering criteria in
413.1.ABCD have been met.
414.-----MOTORS ---------------------------------------------------
-----
- Motor efficiencies in
414.1.ABCD have been met.
415.-----LIGHTING SYSTEMS
-ZONE 1------------------------ -
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)
----------------- --- ------ ----------
---------- ------=-----------
Reception 1 On/Off
3 1047
1047
Reading, T' 1 On/Off
2 291
162
Reading, T 1 On/Off
2 581
323
Reading, T 1 On/Off
2 477
265
Leisure Di 1 On/Off
2 330
132
Toilet and 1 On/Off
2 84
84
Toilet and 1 On/Off
2 53
53
Corridor 1 On/Off
2 178
176
Corridor 1 On/Off
2 15
50
Total Watts for Zone 1 =
3116
Total Area for Zone 1 =
2293
Total Watts =
3�16
"
Total -Area =
2293
CHECK
Lighting criteria in
415.1.ABCD have been met.
16. Operation/maintenance
-------------------------------------------------------------------------
manual will be provided to owner.(102.1)