Loading...
HomeMy WebLinkAbout07) sections details - Esigned5/0" cdx plywood, nailed and glued within 4' of gable rake overhang. Nails to be IOd ring shanks at 4" o.c, at edges and 6" c,c, in field. 2x4 ladder blocking at 2'0" o.c, and panel edges nailed to truss top 8 bat. chords /F w/ (2) 16d nails -over entire span IOd nails a 4" c,c, Simpson H4 clips at ladder to truss See rake Watling below top chords - typ, 12" rake match exist, Gable end sheathed with 1/2" cdx plywood, nailed at 4" o.c, at all edges and 12" o.c, in field. 2x2 blocking - anchor to beam w/ 1/4"x3" lag screws a 12" o.c, bat, chord to blk'g, w/ 16d ring shanks a 8" o.c. Simpson LSTAI2 flat straps 9 16" o.c, w/ 10-I0d into gable end truss a beam. ❑0 SG155j,7n trU55,G� - 2 x 4 blocking at 4' o.c, and panel edges, nailed to truss bottom chords w/ (2) 16d nails. '2x4 cross bracing at peak of gable end to bottom of second truss, and at 6' c,c, each side of peak. Nail to each chord w/ (2) 16d nails. (3) 2x12 porch beam - see framing plan frame out to col, width, wrap w/ 1/2" cdx plywd, and finish per plan Interior wall See typical wall section for roof, fascia and soffit details and notes. Exter i or,,,, 5/8" stucco on p,b, metal lath on Tyveck vapor -barrier on 1/2" cdx plywd, sheathing on 2 x (o studs at Igo" c,c„ R-n batt insulation, smooth finish 1/2" drywall and wood base, (MATCH EXIST,) ANCHOR UPPE TO LOWER WAL SIMPSON LSTA MT616 STRAPS O..C. - VERIFY ON THE JOB Exist, roof trusses Al� 8'2" B.H,— CLG, - EXIST, Exist, concrete slab to be cut-out 8 removed 4 new 18" x IS" conc, mono ftg, u (3) *5 bars coat, 0'0" F.F. GARAGE 1'10" B.F,F, -- -— �2' 4" B.F,I j- ---- 314 9goo C.T A I=I I I=I I 12 3,5 (MATCH EXIST.) -------------------------------- I„I f—a I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I New 2x�p" 2-story W/ 2x(q'$ w 16" o,c„ w/ R-19: batt insulation 4 fini_4h,,w/ 1/2" drywall on bot sides, lOd a 4" O,G, 2" X 4" LADDERS a 24" O,G, 5/0CDX PLYWOOD ATTACH LADDER TO TRUSS TOP CHORD W/ 2-16d NAILS a 24" 2" X 4" BLOCKING CENTERED BENEATH PLYWOOD JOINT, ATTACH BLOCKING W/ 3- 16d TOENAILED OR 2- 16d ENDNAILED EACH END — — — — — — ; — — — — — — — — — — — — — — — — — ; — — — — — — — — — — — — I„I I„I F-3 I I I I I I I I I I I I I I I I I I I I I I I I F-i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I M1-7 I I I I I I I I I I I I I I I 1 I I I I M1-1 -------"'---------------- ------------ ELEVATOR C,T A i=)I I ICI I 2"x4" - CON'T, 10cl NAILS e 4" O,G, FLASHING 2x4 BLOCKING BE LADDERS NAIL W/ 2-16d NAILS 2-16dNAILS � EACH LADDER ACH SIDE TWEE FASCIA Gable end finissd w/ Nardi -plank siding on 150 felt paper or Tyvsk, on 1/2" CDX plywood,nailed at 6" o,c, at all edges and 12" O,c, in field, 12" RAKE (MATCH EXIST) (VERIFY) 99 99 o 099 V2 REMOVE EXIST. ROOF TRUSSES, GUT -BACK EXIST, FLOOR, 8 GIRGER TRUSSES. ADD NEW MIGROLAM BM. (SEE ROOF 8 FL. FRAMING PLAN) F—f—� I I I I I I I I I I I I I I I I I I I I I I I I I — — T I I I I I I I I I I„I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I CHOR UPPED IWALL TO BM, SIMPSON LSt,416 a EA, VERT. 1D, ANCHOR ! BEAM TO 6x5 KN'G (BELOU4);W/ (3)6IMP6ON rAl6 -w 32" 0. (BOTH SIDES) ----------------------------- 21'5" B,H, -1 I2 21'O" SPRING � ------------ HT. AT EXT, WA'CL " Drywall ceiling NEW MAC-r= 3/4" T4G plywood sheathing on 2x4 wd, studs a 16" o.c, on exist, 18"h, floor trusses, HANG EXIST. FLOOR TRUSSES ON NEW MICROLAM BM, W/ 5IMP50N HU525, SEE FL. FRAMING PLAN 12'0" 2ND. F,F,fi 10'2" B.N. /(--Ir ROOFING.., Concrete roof tiles over hot mopped 90* granular roofing, over 30# felt paper tin tagged to 5/8" cdx roof sheathing on engineered wood roof trusses at 24"o,c, The first course of roof sheathing at save should bs nailed and glued, and should be a full 4' width, i 21'8" B,H, - O,H, EAVE.., Galy, metal drip edge on Ix2 trim on 2x6 r,s, cedar fascia w/ stucco soffit on high rib mtl, lath w/ 2" cont, screen vent (MATCH EXIST,) 5/5" stucco on p,b, metal lath on Tyveck vapor -barrier on cdx plywd, sheathing on 2 x ( studs at 16 " o,c„ R-19 batt insulation, smooth finish 1/2" drywall and wood base. (MATCH EXIST. Attach upper wall to girder w/ SIMPSON MTS16 Q 32" o,c, S'2" 5,H, / CLG. EXIST, Digitally signed by Mark W Mark A. Corson Corson Date: En 2020.11.30 11:46:08-05'00' 12 3,5 (MATCH EXIST.) 12 ceiling 12 -= _ - W8a l on Simpson 5P6 c I ps at each stud to dbl, top plate and Simpson strap at sa, truss see framing plan NEW MASTER SITTING 1/2" gyp bd, on 2x6 studs at Ito" o.c, w/ 5 1/2" batt insul, (R-le) 3/4" T4G plywd sheath, screwed 8 glued on 2x wd, blk'g, w 16" o,c, on exist, 18" fl, trusses Exist. 15" deep fl, trusses over exist, wall 5/0" drywall on ceiling °0 4 Exist, bm, (vsrify) a ,. w v , o Vol •D Q' Exist, S" conc, blk, exterior garage wall, I) LL W El 12'0" 2ND. F,F, NEW - MATCH JEXIST, I1'5" TERRACE (EXIST, 10'2" B.N, / CLG, TYPo WALL Sj"CT1r1nU`N 31400e¶>�ea ll 2-STORM' SECTION 'S EXIST. TERRACE z — W °o> z � z — y m — ooD1�U'o 0 cp (K N Q) 3 N 13 Oe W ,e 0 L0 _Q �� o- os�To� an �7Nz N� �o �..s o (Y T �0 �� O U O� p�� o = U L O '3U U O 4 J 4 a Q -C 4 a U F_.4 6 0 3 3 m • U z z V ON M v JIM O CIO a N Q V) 0 N .. ti � N 0 v � O CrA 0 O a O U • DATE 10/23/20 DRAWN BY: pie me CHECKED Mc REVISIONS A 11/30/20 PER B.D