HomeMy WebLinkAboutRevised A-4Ceramic Tile Shall be installed in accordance with ANSI A108.1, A108.4, A108.5 A108.6, A108.11, A118.1, A118.3, A136.1, & All37.1. Fiber mat reinforced backer shall be used behind wall applied ceramic tiles in the tub and shower areas and conform to ASTM C1325. Per Durock, cement board exceeds ASTM C1325. Gypsum Note Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047 C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential code. Per USG, Wallboard conforms to C1396. Gypsum Board & Gypsum Panel Products Gypsum board and gypsum panel products shall be applied at right angles or parallel to framing members. All edges and ends of gypsum board and gypsum panel products shall occur on framing members, except those edges and ends that are perpendicular to the framing members. Interior gypsum board shall not be installed where it is directly exposed to weather or to water. Wall and ceiling gypsum board shall be fastened with screws spaced at 12"o,c. Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C 1002 andshall penetrate thewood not less than 5/8" inch (15.9mm) Gypsum board and Gypsum panel products shall be attached to cold formed steel framing less than 0.033 (1 mm) thick shall be Type S in accordance with ASTM C1002 or bugle head style in accordance with ASTM C1513 and shall penetrate the steel not less than 3/8"" to 0.112" (1 mm to 3mm) thick shall be in accordance with ASTM C954 or bugle head style in accordance with ASTM 1513. Screws for attaching gypsum board or gypsum panel products to structural insulated panles shall penetrate the wood structural panle facing not less than 7/16"o.c. (11.1 mm). Gypsum board used as the base orbacker for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396, C1178, C1278. Use of water resistant gypsum backing board shall be permitted on ceilings. Water resistant gypsum board shall not be installed over a Class 1 or Class 2 vapor retarder in a shower or tub compartment. Cut or exposed edges, including those at wall intersections, shall be sealed as recommended by the manufactuer. Water resistant gypsum backing board shall not be used where there will be direct exposure to water, or areas subject to continuous high humidity. Cold Formed Steel Note Cold formed steel framing supporting gypsum board and gypsum panel products shall be not less than 1 1 /4"" (32mm) wide in the least dimension. Non Load bearing cold formed steel framing shall comply with AISI S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AISI S200 and ASTM C955, Section 8. Wood Framing Note Wood framing supporting gypsum board and gypsum panel products shall be not less than 2"" (51 mm) nominal thickness in th least dimension except that wood furring strips not less than 1 " by 2"" (25mm x 51 mm) nominal dimension shall be permitted to be used over solid backing or framing spaced not more than 24"o.c. (610mm) 2 x 4 blocking at 4'-0""o.c. starting from ridge between both top and bottom cords for two truss spaces from gable end See truss shop - - drawings 2 x 4 diagonal "X"" bracing at 8'-0"o.c. starting from ridge with (3) 12d each end Galv. drip edge min. 4„ lap 2- dia. Galv Pipe <tsreues \-1 x3p.t.over2x6 Paint Grade Fascia Set ballard 124 from appliance (2) 12d o.c. Galv. Collar Gable end truss by truss mfgr. 19/32" c.d.x. plywood with 8d nails 4"o.c. Cover with House Wrap Continuous 2 x 4 Lateral bracing at 1 /3 points of span. Nail with (2) 16d each truss btm. cord Continuous 2 x 4 bracing fastened to beam with _/ 5/8" x 6"" wedge bolts with 1 /8"" x 2" washer 24""o.c. i w , do Alum. window frame 3/8" continuous bead of caulk (back bedding) behind shim to prevent liquid passage 1 /4" struct. shi set flange in continuous bead of caulk across the entire face of buck perimeter caulk stucco finish--, Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction precast J conc. sill corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval window sill 2x "" L"" web stiffener (4) 1 /4- x 2 1/4"- as required by the Tapcons trus-� mfgr. ""Simpson"" HETA16 truss to bond beam with 0 4) 10d x 1 1/2- located at each truss vertical Concrete Bond Beam Typical Precast Conc. Sill Detail 8" x 16" C.M.U. WITH CELLS FILLED WITH GROUT & (1) #5 VERT. �, .. DOWEL _J P.T. 2 x 6 AT (3) SIDES OF Q OPENING, FASTEN TO BLOCK �- AS NOTED. 3/8" continuous bead of w caulk (back bedding) behind DOOR SIDES buck to prevent liquid passage 1/2" x 6-REDHEADS WITH MIN. 2- x 1/8-WASHER 12" FROM ENDS AND 24" o.c. MAX. set flange in continuous bead of caulk across the DOOR HEAD entire face of buck Z i i o_ � 1 /4" x 2 3/4�" TAPCONS STAGGERED CBS O I I 24-o.c. o I• o OR 5/8" x 6- Redheads with Min. 2- x 1 /8" washer 12- from Min. 1 1 /4"" embedment ends and 28"o.c. max. OR " a au a . at windows and min. 1 /4 x 1 1 /4�" min. embedment T 4- "C a 1 1 /2"" embedment at spaced at 7 1 /2""o.c. with 1- O.D. °o -ov d) a ' d 4' a 'd sl. gl. doors washers spaced bottom anchor c Oo at 3 1 /2"" from bottom of 2 x 6 5 and top anchor at least as high ° ° a as the door opening. o 0-0 y a W 1 N.�� .° 1/2"" drywall Garage Door Buck Detail � r> JUwm p 2 x 4 bottom cord bracine 10'-0" Bottom Cord Lateral Bracing stucco finish perimeter caulk Attach p.t. bucks with 8d coil nails at 12""o.c. Typ. Alum. window . jamb or sliding glass door jamb 1/4- max. struct. shim caulk attach as per manufacturers product approvals NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured concrete sill. greater for proper joint expansion and contraction Coat Bucks with LWM200 Waterproofing after they have been installed and Chaulked Window & Door Flashing Detail at CBS Wall Includes Buck Attachment Method Galv. Cap GENERAL ROOFING NOTES Typical Conc. Foundation Bollard Detail SHEATHING NAILING NOTES Roofing to be composed of and attached to pre manufactured wood trusses as follows: Felt underlayment (min. ASTM 0 226 Type II) with 4" min. side and end laps, fasten with coorosion resistant annular ring shank nails at 6"o.c. in laps and in staggered rows spaced 12""o.c. in field. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12 or greater, install (1) layer 30# felt. 19/32"" plywd. sheathing or equal installed with staggered joints & GI clips, nailed to trusses with 8d corrosion resistant annular ring shank nails spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends. All roof trusses are to be pre -manufactured assemblies provided by a licensed wood truss fabricator with seperate drawings and data prepared for actual project conditions by a Florida registered professional engineer certified for truss design. Any deviation from the proposed plans as shown regarding placement or bearing shall be brought to the attention of the truss engineer prior to fabrication of the trusses. The truss manufacturer's certified layout shall govern after fabrication. The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. drawings and data. All engineered headers and truss hangers to be provided by the truss manufacturer. Splitting or cracking of structural components due to installation of hardware is not permitted. Unless otherwise noted, the installation of specified hardware shall conform to the truss manufacturers installation instructions and standard practice. BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 1 /4- DIA. TAPCONS WITH 1 1 /4" EMBEDMENT INTO C.B.S. SET A 6"" FROM CORNERS AND AT 12""o.c. MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR ""T" NAILS" 4" FROM ENDS AND 12"o.c. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION THRESHOLD NOTE At egress door (see floor plan) the max. hgth. of the threshold shall be 1/2- Nailing Pattern Nailing Schedule Zone 1: 8d at 6-o.c. field & 4"o.c. edges ROOF & FLOOR DIAGRAM Zone 2: 8d at 4"o.c. edges & field Use sheathing with #8 gun nails at 6-o.c. Zone 3: 8d at 4-o.c. edges & field at supported panel edges and #8 gun nails at 6"o.c. at intermediate supports. Pneumatic Nails � ROOF SHEATHING TO GABLE END FRAME Pneumatic or mechanicaly driven nails will Use #8 gun nails at 4"o.c. be accepted under the following conditions. Min. nails size 8d or larger ring shank with EXTERIOR SHEATHING Min. shank diameter:.113 Min. Length: 2" Use #8 gun nails at 4-o.c. at panel edges Min. Head Diameter:.280 Full Round and #8 gun nails at 4-o.c. at panel top and Min. Ring Diameter .012 over shank dia. bottom and 6""o.c. in field Min. 16 to 20 Rings per Inch Note Gun nails shall be permitted as an acceptable fastener from any manufacturer Wood screws meeting the same size requirement may be used in lieu of nails without comment corner bars at beam (outside only) (2) corner bars at footing (min.) vert. dowel lapped with II wall reinforcing, all II all corner bars to be the laps 30" (min.) in grout II same size, number, and filled cell II spacing as horizontial bars in footing, beams, and walls Y II o II 0 s I 41 I�_-------- 1 11 30" lap min. Corner Reinforcing Detail PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures Head: 12' max. from corners & 30"o.c. max. Jambs: SH-5500 12" max. from corners & 17.7" max. 5" each side of FL: 239.7 S.H. Windows Singlehung PGT Industries Impact meeting rail. Use 3/16" Tapcon with 1 1 /4" embedment +33.5 -44.8 +/- 50.0 into concrete Head: 2" max, from corners & (1) at center. Jambs: FL# 17499.9 S.H. Windows 185 SH MI Windows Impact 2"max. from corners & (2) equal spaced at each side of meeting rail. Use 3/16"" Tapcon with 1 1/4"embedment +33.5 -44.8 +/- 55.0 into concrete Glazed 6" from corners and 3'& Teach side of center at head & FL#: 17184.2 Swing Doors Fiberglass Plastpro Impact sill and 6"from corners & 14 1/4"max. o.c. at jambs. +33.5 -36.3 +/- 50.0 Door 1 /4" tapcon screws with 1 1 /4- embed. into conc. Fiberglass Plastpro Impact 6" from corners & 14"�o.c. at jambs, head, sill. 1 /4" tapcon +33.5 -36.3 + 65.0 -70.0 (Inswing) FL#: 17184.5 Swing Doors Door screws with 1 1 /4- embed. into conc. +/- 65.0 (Outswing) FL#: 5678.28 Overhead Door Grand Harbour Clopay y Impact Flag Bracket Angle (3) total 5/16"" x 1 5/8- lag screws. (7) total Bracket T-0" height (1) 5/16" x 1 5/8- lag screws per bracket. +27 9 -31 2 +37.0 -41.0 Series Approval product Model Number Manufacturer Attachment Method Building Rated Design Pressures Product Rated Design Pressures Number FL: 17443.1 Roofing 5V Crimp p JA Taylor Roofing #9-15 x 1 "" coorosion resistant screw with sealing washer at each rib 12"o.c. in field and 6""o.c. along perimeter. -45.0 -69.25 FL:9777.7 Roofing Underlayment Wel Speciapecialtyty Owens Corning Direct attachment to plywood deck -45.0 -142.5 Fasteners shall be ET&F block nail .30 Head dia..14 Shank dia. & FL#: 13192.2 Siding Lap Siding James Hardie 1 1 /4" long. 21 "o.c. max. spacing (AT C.B.S.) Use 11 ga. x 1 1 /4- -45.0 -76.7 Long roofing nail 24"o.c. at each gable truss vertical STRUCTURAL NOTES: All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30"" in beams and in slabs. Lap bottom steel over supports and top steel at midspan. Hook discontinuous ends of all top bars. Reinforcing steel shall have a minimum of 1 "" concrete cover, or as follows: BOTTOM TOP SIDES Beams: 1 1 /2" 1 1 /2" 1 1 /2" Slab on Grade: 1 1 /2' 1" _ Structural Poured: 3/4"" 3/4" _ Poured Walls: - _ 3/4"" Slabs exposed to the weather 3/4" 1 Reinforcing steel shall be detailed and fabricated in accordance with the "Manual of Standard Practice of Detailing Reinforcing Concrete Structures"" and the current ""ACI Building Code 318"" All structural steel shall conform to current ASTM Specification A-36 All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. No slump over 5"" shall be permitted for any structural concrete without the Architect or Engineer approval. All Design and Construction shall be inaccordance with the current American Concrete Institute (ACI). and the American Institute of Steel Construction (AISC), The Florida Building Code and all applicable local codes. Structural Concrete shall attain a minimum ultimate compressive strength (Fc') in 28 days as follows: Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof: see column schedule. All other concrete: 3000 p.s.i. Footing sizes and reinforcing are based on allowable soil bearing capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before proceeding with the work. Timber (Heavy Timber Construction) (a) Truss manufacturer shall submit a signed and sealed shop drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. (c) Roof members should be secured to the beams or other structural components with hurricane anchors for wind uplift. All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1 /360 max. deflection. All bolted connections shall be 1 /2"" Cadmium plated or better. Lag bolts to be used only in shear connections with minimum 4"" threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. EXTERIOR CEILING & SOFFIT NOTE 7/8"" Stucco finish over 3/8"" high ribbed galy. wire lath fastened to framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" dia. head 6""o.c. max. edges to be tied and nailed at 9"o.c. Provide one layer of 15# felt to framing prior to installing wire lath. INTERIOR WALL FRAMING NOTE Interior non bearing walls to be 2 x 4 studs 24"o.c. Spruce, Pine, Fir (SPF) #2 Grade lumber or better or metal studs (25 Ga.) Crimper may be used in lieu of screws. V C o 0 CV M L. 0 W z M C_ C - LL tr'> c0 rn W a a. to 00 r- ®.14 J l�L r- . _. Q ai Z 0- w > p U) Lo W CD rn 4-J 0 cu I- > W Q r- /" ~ � .� Up N �� � �oz 00 ry Q UJ f� N r, ~ cu 00 T L� CJ W U Z W Q a U ■--� CU 72 LLI _O LL >-- � c � J 0 _ W <( v :3 LL W J L Z W date revision 1 11 /24/20 Plan Review Comments Dated 11/24/2020 , drawn S.I. checked s.l. date 10/28/2020 scale as noted job number 20052 sheet A-4