HomeMy WebLinkAboutRevised A-1s C #5nrebar at too :V 1 quanity of #5 rebar e-- at bottom of lintel Ca 'i yity r F= filled grout '— Lo i width e� C.M. .E 8F16-1 B/1 T T einfo... d aataeta T qe anity bf #$ J j�$ bar sat bottom omi al bar at top vity heigth 8" Nominal Lintel Type Designation Safe Load Table Notes 1. All values based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 20% if bearing length is less than 6 1 /2". 2. N.R. = Not Rated 3. Safe loads are superimposed allowable loads. 4. One #7 rebar may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per tinier foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. Floor Plan Scale: 3/16- = 1'-0- Composite U Lintel Materials 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S Installation Notes 1. Installation of U lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1/2"" long notch at both ends to accomodate vertical cell reinforcing and grout. =nr n" Cast Crete Lintel Schedule All RPhar +n ho ±tR (`_Y..de nn —:— MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 4'-6" 6113 865 2724 172 8F161B/1T L-2 4'-2" 6113 1019 2724 218 8F161B/1T L-3 3'-10" 6113 515 3079 109 8F16 WIT L-4 4'-8" 4567 515 1960 109 8RF141B/1T L-5 4'-8" 6389 212 2618 59 8RF181B/1T L-6 1 T-4" 1326 103 520 44 8F20 WIT T L-7 T-8"" 6113 152 3079 43 8F16 1 B/1 T L-8 T-8"" 1568 543 937 125 8RF141B/1T Min. Beam depths shown, beams may be increased without comment At Lintels over 24 deep provide (1) #4 vertical rebar tied to Horiz, steel at 24"o.c. along length of lintel Cast in place sill or Tie Beam Option In the event that precast products are damaged in the field cast in place sills and tie beams may be used (not to exceed 5'-10") Typical cast in place tie beam to be a min. 8" x 12- with (2) #5 top and (2) #5 bottom Connector Schedule Truss Bearing Point Truss Uplift Connector ID Qnty. Connector Fasteners Uplift All trusses Each to CBS Brng. <1000 HETA20 1 1810 (9) 10d x 1 1 /2" Supporting Valley Framing (4) 10d Trusses <250 VTCR 1 370 Valley Truss (3) 10d x 1 1/2" Connector Notes: Project Data Project Name: Trefelner Residence Street Address: XXXX Roland Ct. City: Lakewood Park County: St. Lucie State: Florida Scope of Work New One level CBS Single Family residence Design Loads Roof Live Load: 20.0 p.s.f. Wind Speed: 160 MPH Wind Importance Factor: 1.0 Building Category: II Wind Exposure: B Internal Pressure Coefficent:.18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Area Tabulation Building Code Living: 1425 2017 Florida Building Code: Residential Garage: 426Entry: 100 2014 National Electrical Code: NFPA 70 Total: 1951 Building Data Occupancy Type: Group R Total Cubic Volume: 13395 c.f. Construction Type: V Number of Stories: One Project Area: 1951 s.f. Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 5V CRIMP METAL ROOFING ON PEEL & STICK UNDERLAYMENT OVER 5/8" C.D.X. PLYWOOD -� SEE CONNECTOR SCHEDULE --- \ PRE ENG. WD. TRUSSES 24""c.c. ALUM. DRIP EDGE ON 1 x2P.T.ON2x6 CEDAR FASCIA -,\ STUCCO SOFFIT WITH 8°" x 16"" SCREEN VENTS - 8'-0""o.c. ALONG GARAGE & ENTRY LEVEL RETURNS BY TRUSS MFG. 12 5 R20 SPRAY FOAM INSUL. 5/8"" D.W. 1 x 2 P.T. FIRESTOP (2) COURSE BOND BEAM WITH (1) #5 REBAR FILLED WITH 1 -6 GROUT EACH COURSE PROVIDE "CASTCRETE" PRECAST LINTELS ABOVE ALL OPENINGS TWO COAT STUCCO FINISH OVER CBS (SIDES & REAR) HARDIE SIDING ON FRONT ELEVATION Do not substitute connectors Attach valleytrusses and i GRADE piggy back trusses, if present, A.T.R. =All Treaded Rod to main trusses per truss manufacturer drawing. Drill and Epoxy Set all A.T.R. Truss to truss connection by truss company, installed per manufacturers spec's. Do not sheath trusses before all straps are in place Lateral forces perpendicular and parallel to wall has been Other specs, if different from above, have priority. considered (less than 300 p.l.f.) Use either "Hilti"" C-100 or Simpson Epoxy Tie Epoxy Contractor to approve temporary bracing to prevent Provide equal number of studs under girders equal to toppling of trusses, see HIB-9. the number of plys. 8 x 16 x 8 C.M.U. WITH #5 VERT. DOWEL IN GROUT FILLED CELLS 1 x 2 P.T. FURRING 24""o.c. I R4.2 INSUL. ON FURRING 24"o.c. 1 /2" GYP. D.W. 1 x 2 P.T. FIRESTOP _ X14"" 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER / ON CLEAN, COMPACTED, --------- TERMITE TREATED FILL Typical Wall Section U Q I w N O 00 i w z � M LLU-) Cn '14- U Q0 _ • U) N ® 1v LO b=00 J .4 LL I` • — _Q ICU w v p o > --I W w Lo co a� 1 Er d- W +J cu CU UJLO Q . � N ■ •� vo alt ) T Z � N .� LU co T-- u.1 CJ z w U) W J Q LL LL1 J z M U � -� 0 r c 0 Lee. 0 U 4— +; (1) w L le — date revision 11 /24/20 Plan Review Comments 1 . Dated 11/24/2020 drawn s.l. checked s.l. date 10/26/2020 scale as noted job number 20052 sheet A-1 0 ti