Loading...
HomeMy WebLinkAboutDesign Certification for Wind Load Compliance'FIL _ ' STi LUCIE COUNTY PPARTMENT OF COMMUNITY DEVELOPMENT r \' 23W VIRGINIA AVENUE FT. PIERCE, FL., 34982-be62 _ W 482-1653 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE This Certification Is to be Completed by the project design architect or, 9601nier.. This Coral on must be s�mitted with all applications for budding permit, Involving the ro ident ial of new rssldwxe (Single oriWA-iarrrtly), realdentlal adcRon, any acemory structure requiring e building permit, and arty nonraaWoMlal sttucture. This Certlfioatlon shall riot apply to Interior renovations (provided that no structural wads, colurrm or other Sirrrlar component Is behtp effected) and oertntn ether minor building.p0rmlts. For tiuther assistance, please confect the Building InopeoWn OFiCe at 4M-11553 or 462-2172. PROJECT NAME R S t CAN S'o B 1 2 7 (i STREET ADDRCOt! Cj OR11 bA '% F'/ 16F , O/U PAR'C EL, PR NUMBER #J--OOoJ�UDO PERMIT NUMBER /o UAN T v A /N `/p 6- �15 wep, TYPE CST, TYPE I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OF THE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY -THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS, DESIGN PARAMETERS AND ASSUMPTIONS U$ED' rfllass check or omyja a the aRgron. 1. STANDARD BUILDING CODE 1097 EDITION ASCE 7-95 OTHER (SPECIFY), 2. BUILDING DESIGN 18 (a-EOK ow ENCLOSED PARTIALLY ENCLOSED OPEN BUILDING /11 3. BUILDING WOW; FT 4, WIND SPEED USED IN BUILDING DESIGN: /� � MPH 6• WIND EXPOSURE CLASSIFICATION (REFER TO IMPOSURE TABLES IN ISMAINO MM IpUWVFje0 IN CM! tit): C- 6, AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: - PSF 7. PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURA- PSF 4. IMPORTANCFJUSE FACTOR (OBUUtFROM BULDWO COM): /1 0 0. LOADS' FLOOR VPar mxFIDEAD; PSF ROOFJLIVE; PSF 10, WERE SHEAR WALLS CONSIDERED FOR STRUCTURE ((NECK ONE) YES ✓ NO _ 11 NO, why? (atOtcth axplrmnawn) 11. IS A CONTINUOUS LOAD PATH PROVIDED (CHzcKONC) YES ✓ NO _ ifNO, *V (mtwh vatplalnaibn) 12. ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK ONE) YES ► O — If NO, why? (attach oxplalnptlon) 13 MINIMUM SOIL SWING PRESSURE: ),0 lPSFI `k • AS WITNESSED BY MY SEAL, I HERE8Y CERTIFY THAT THE INFORMATION INCLUDED 1MTH THIS CERTIFICATION IS TRUE AND COR CT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, NAME: CERTIFICATION NO; DESIGN FIRM; DATE: [SEAL HERE] GR C GLOM FORM NO: on-M ENGINEERING 5544 W. 147th Street Oak Forest: 11. 60452