HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY -EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYN`Nq THE GRAND CARLTON IMPACT
Builder Name: WYNNE BUILDING COPR.
Street: \\ < C�U'Z,
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction.or existing New (From Plans)
9. Wall Types (1442.0 soft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 . 1250.00 ft2
3. Number of units, if multiple.family 1
b. Frame - Wood, Adjacent
c. N/A
R=11.0 192.00-ft2
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 soft.)
Insulation, Area
a. Under. Attic (Vented)
R=30.0 11446.0012
6. Conditioned floor area above grade (ft2) 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2)2
0
N/A_
R
11. ucts
R ft2
7. Windows(141.3 soft:) Description Area
a. Sup: Attic, Ret: Attic; AH: Attic
6 175
a. U-Factor:' Sgl, U=1..04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0:27
a. Central Unit
.34.8 SEER:15.00
c. U-Factor: ' N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. lJ-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832. ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. FIooY Types (1445.5 soft.) Insulation Area
a. Electric
Cap: 50 gallonsEF:
a. Slab -On -Grade Edge Insulation R=0.0 1445,50 ft2
b. Conservation features
0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 47.47
Glass/Floor Area: 0.098
A
PASS
Total Baseline Loads: 48.09
I •hereby certify that the plans and specifications covered by
Review of the plans and
0 'fp's
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance]„fir.►
with the Florida Energy Code.
. ///r,1 �i;
PREPAREp I3Y;'
Before construction is completed
_ ;.
DATE:
this building will be inspected for
compliance with Section 553.908
Lhereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Co e.
OWNER/AG€N
BUILDING OFFICIAL:
DATE: \��
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies -as
certified factory -sealed in accordance with R403.3.ill.
- Compliance requires an Air -Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and -this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - NaRes2017 FBC 6th Edition (2017) Compliant Software : Pagel of 5
'FORM R405-2017 INPUTSUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2,
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst.Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:
Permit Office.: ST.. LUCIE COUNTY Cross Ventilation: No
County:.
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT, PIERCE ,
Family Type: Single-family.
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design•Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
/Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms' InfilID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes.
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M.BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5. BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes -
Yes
Yes
7 ENTRY. 55 440 No 0
1 Yes
Yes.
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space. Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
301 ftz
___
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ftz
_
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ftz
M_
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ftz
____
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ftz
___
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ftz
___
.0 1
0
7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0
55 ftz
0 1
0
4/21/202010:27 AM EnergyGauge® USA 6.0:02 (Rev. 1) - FIdRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
- FORM R405-2017 INPUT SUMMARY C1417r- ' IST RFP.ART
FLOORS'
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
8 Slab -On -Grade Edgelnsulatio LAUNDRY 6 ft 0
42 ft2
_e_
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
____
0
1
0
ROOF
/ Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee.Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
.WALLS
Adjacent Cavity Width
nmf To IAJAII Type Space
Height
Sheathing Framing Solar Below
1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
_ 3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4 SW.=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2.
0
0
0.4
0
5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW Exterior Concrete Block - Int InsE1EDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior Concrete Block - Int Ins8EDR0OM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block - Int InsBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Int Ins61EDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft2.
0
0
0.4
0
_13 NE=>SW Exterior Concrete Block- Int InstOREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Int InstOREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software • Page 3 of 5
- FORM R405-2017 INPUT SUMMARY r:HF(_KI, ICT l2gtPng2T
-- - - -- - --- - - - -
WALLS
Adjacent
Cavity Width Height Sheathing Framing Solar Below
Space
15 N=>S Garage Frame - Wood KITCHEN 11 24, 8 192.0 ft2
0.23 0.4
0
DOORS .
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown -is the entered orientation. => changed to Worst Case..
j Wall
# Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation InfShade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E.Single Yes
1.04 0.29 Y ' 32.9 ft2 1 It 0 in 1 ft 5 in
1.04 0.29 Y 6.9 ft2 1 It 0 in 1 ft 5 in
1.04 0.29 Y 24.0 ft' 6 ft 0 in 1 ft 5 in
1.04 0.29 Y 37.5 ft2 1 It 0 in 1 ft 5 in
1.11 0.27 Y 40.0 ft2 8 ft 0 in .1 ft 5 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall'Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .1233
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singi SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType Location
EF `Cap Use SetPnt
Conservation
1 Electric"
None Garage
0.97 50 gal 60.9 gal 120 deg
None
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 ANPUT SUMMARY GHFCKI IRT RFPnRT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
#
Area Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ---
Air
CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT QN RLF
Heat Cool
1 Attic
6 175 ft2
Attic
65 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Co fin Jan Feb
Heatinf X� Jan Feb
Jan Feb
Mar
Mar
Mar
A r
f Apr
f
Ma
May
Jun Jul
4 Jun 4 Jul
Au
4 Au4
Se Oct N:Nov
Sep f Oct
Nov
Dec
f X� Dec
Venting[ ] .
[X] Apr
[
May
[ Jun [ Jul
[ Aug
[
Se [X] Oct
Nov
[ l Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling-(WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78-
78
Cooling (WEH) AM
78
78
78
78
78 78'
78
78
78 78-
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
.
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 lbs/sq.ft..
ft2
ft
0.3
FOYER
Default(8 Ibs/s .ft.
ft2
ft
0.3
BEDROOM-8
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER'AND'INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in.any dropped ceiling/soffit shall .be aligned with
The insulation in an ceiling/soffit
dro ceilin g
the insulation and any gaps in the air.banier.shall be sealed.
shall be alignedy aied
with the ' air barrier.
Access. openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
Walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space -shall be sealed.
'Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that.on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
9s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior -walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or -drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plat s and walls or cemnas. -
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/21/2020 10:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC-6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE, LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =. 99
The lower the -Energy Performance Index, the. more efficient the home:
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2.. Single-family or multiple -family 2: Single-family b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if. multiple -family) 3. 1
4: Number of bedrooms 4. 2
5. Is this a worst case? (yes/no) 5. Yes
6. Conditioned floor area (sq. ft.) 6.. 1446
7. Windows, type and area
a) U-factor.(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient(SHGC)
7b.
0.284
c) Area
7c.
141.3
8. Skylights
a) U-factor:(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood,. raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame. (Insulation R-value)
2. Masonry:(lnsulation R-value)
B. Adjacent:
1. Wood frame (Insulation R=value)
2. Masonry (Insulation R-value)
11. Ceiling type. and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
•9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
1081. 11.0
1062.
11a. 30.0
11 b.
11c. 19.0
11d. No
13. Cooling system: Capacity 34.8
a) Split system. SEER. .15.0
b) Single package . SEER
c) Ground/water source SEERICOP .
d) Room unit/PTAC EER
e) Other
14. Heating system: . Capacity 34.8
a) Split system heat pump HSPF . 8.5.
".b) Single package heat_pump' HSPF
c) Electric resistance COP
d) Gas furnace, natural gas . AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF '0.97
b) Gas fired, natural gas EF
c),Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%6
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house.fan No
d) Multizone cooling credit
e) Multizone heating credit
0 Programmable.thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if hot DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above, 'energy
saving features 'which will be installed (or exceeded):in this home before final inspection. Otherwise, a newfPL
display card will .be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home\ v� ��- City/FL Zip: FT. PIERCE FL
P
4/21/202010:32:17 AM EnergyGauge® USA 6.0.04 (Rev:1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1