Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Design Pressures
Florida Window & Door Co. 1 125 N. Dixie Hwy LakeWorth, FL 33460 Tel. (561) 848-4900 Floridawindowanddoor.com Property Information Building Information Owner: Barry Striker Wind Zone: 160 MPH. Address: 7906 Belmont Avenue Exposure Category: C Fort Pierce, FL 34951 Minimum Building Dimension: 35 ft. Mean Roof Height: 10 ft. Risk Category: II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psfj Max Negative Pressure (psf) 1 End 74 50 7 31.4 -40.7 2 End 19 26 7 33.5 -44.8 3 End 74 38 7 32.0 -41.9 4 End 37 38 7 33.5 -44.8 5 End 37 38 7 33.5 -44.8 6 End 37 38 7 33.5 -44.8 7 End 74 50 7 31.4 -40.7 8 End 111 50 7 30.5 -39.0 9 End 37 38 7 33.5 -44.8 10 End 37 38 7 33.5 -44.8 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1